TM ll SS Industrial Dial Thermometer Gas Filled system Special Features approved electrical contacts. Inert gas filled expansion system. Stainless steel case & stem With or without thermowell Silicon oil filled (optional) Standard followed EN 90. pplication ll stainless steel inert gas filled thermometers are suitable for corrosive media / environments in process industry chemical Food Pharmaceutical Pulp Paper Refinery Cement & many more. CE Specifications Standard Version,mm 00 mm, mm, 00 mm & mm ccuracy mbient temperature Operating pressure Over range limit Stem diameter Process connection Class as per EN 90 -oc to oc kg/cm ( without thermowell ) 0% of Full Scale 8 mm ½ SP (M) djustable Case & bezel Stem & connection Joints ISI 04 SS (ayonet Type) ISI SS Tig rgon arc welding Protection Dial Pointer Gasket & Filling Plug IP 8 luminium, black graduation on white background luminium, black Coloured Micrometer Zero adjustable Toughened Glass Neoprene Standard version Electrical contacts ccuracy mbient Temperature Dampening Liquids Other Features Class as per EN 90 Maximum C Polycarbonate Dome Dielectric Oil (Optional) Refer Specification of Standard Version Standard version Silicon oil filled ccuracy mbient Temperature Dampening Liquids Gasket & Filling Plug Other Features Class as per EN 90 Maximum C Plexi Glass Silicon Oil (Option Q) Viton Refer Specification of Standard Version Nominal range, measuring ranges & limits of error as per EN 90 Nominal ( C) Measuring ( C) Limits of Error (± C) -0 to +40-0 to +0-0 to +0-0 to + -0 to +0-0 to +0-0 to +0-0 to +0-0 to + -0 to +40-0 to +0-0 to +0-40 to +40-0 to +0-40 to +0-0 to + -00 to +0-80 to +40 0 to 0 0 to 0 to 80 0 to 0 0 to 00 0 to 90 0 to 0 0 to 0 0 to 0 0 to 40 0 to 00 0 to 80 0 to 0 to 0. 0 to 00 0 to 0 0 to 400 to 0 to 0 to 0 0 to 00 00 to 0 0 Gasket & Filling plug of Viton. Note The addition of mechanical electric contacts affects the accuracy of instruments such that % becomes.%,.% becomes.4% etc. (dd the % of accuracy; If the contact is of the magnetically assisted type, this value can t be added within the ±% of setting point.) Issue. 0/0/0 Design and specifications are subject to change without prior notice Page /
ll SS Industrial Dial Thermometer Ensuring ccuracy and Performance Dimensions - Standard Version S TYPE TYPE ØU ØN M S M ØU ØN pprox. Wt.# pprox. Wt.# 00 00. 4 00 8 4 49 4. 8 8 8 8 49 00. 9 0 4. 8. 4 8 90 000.0.0 000.0.0 00 00. 8 8 00 49 49 00 4.0.0 0.0 000.0 ( s per customer requirement.) (# Weight in grams with box for mm stem length & meter capillary. ) TYPE ( s per customer requirement.) (# Weight in grams with box for mm stem length.) TYPE ØU ØN 0 O pprox. Wt.# S ØU ØN pprox. Wt.# 00 00. 8 8 00 49 49 00 4.0.0 0.0 000.0 00 00. 8 8 00 49 49 00. 0 4. 8 4 8 8 90 000.0.0 000.0.0 ( s per customer requirement.) (# Weight in grams with box for mm stem length.) ( s per customer requirement.) (# Weight in grams with box for mm stem length & meter capillary. ) TYPE 8 00 00. 8 8 00 49 49 00 4 pprox. Wt.#.0.0 0.0 000.0 ( s per customer requirement.) (# Weight in grams with box for mm stem length. ) Issue. 0/0/0 Design and specifications are subject to change without prior notice Page /
ll SS Industrial Dial Thermometer Ensuring ccuracy and Performance Dimensions - Standard Version TYPE 9 J K V J K V pprox. Wt.# 00 00. 8 8 00 49 49 00 4 0 80 0 08 08 0 00.0 00.0.0 400.0 ( s per customer requirement.) (# Weight in grams with box for 00 mm stem length & meter capillary. ) Notes Drawings are not to scale. ll Dimensions are in mm. = Nominal Size. Table Note We offer National / International Scales like C, F & Dual scale in C, F & scales as per the requirement can be provided on request. following are the example tables for C Standard s Positive range single scale in C 0/ 0 0/ 80 0/00 Compound range single scale in C Ranage 0/0 0/0 0/00-80 / 0-0 / 0-0 / 40 CCESSORIES ( Refer datasheet for Thermowells) Thermowell - 0 / 80 0/ 0/00 0/400-40 / 0-0 / 0/0 0/00 / - 0 / 80-0 /00 Note Compound ranges are not recommended for electrical contact option. Refer table for limits of error as per EN90 (On First Page) Ranage Issue. 0/0/0 Design and specifications are subject to change without prior notice Page /
ll SS Industrial Dial Thermometer Ensuring ccuracy and Performance Electrical Contact Wiring Information Wiring diagrams for electric contacts Single Contact NO NC Opening Closing Double contact NO + NC NC + NC Opening Closing Closing Closing NC + NO NO + NO Closing Opening Opening Opening Issue. 0/0/0 Design and specifications are subject to change without prior notice Page 4 /
ll SS Industrial Dial Thermometer Ensuring ccuracy and Performance How To Order asic Model Code Nominal Size 40 0 Type of Mounting(without Capillary option) Process Connection M NM TM Wall/surface/projection mounting With bottom entry Direct bottom entry Direct lower back entry /8" SP (M) 4M /8 NPT (M)# 4NM /8 SPT (M)# 4TM Suitable for stem diameter to 0 mm Process Connection Type Stem Diameter Please specify in mm 8 9 ½ SP (M) (Standard) M ½ NPT (M)# 4MM ½ SPT (M)# 00 mm mm mm Lower back entry with front flange Every angle back entry Lower back entry with mounting bracket (# Not recommended for Revolving/ Swivel connections.) ¾ SP (M) M0 x. (M) D djustable (Standard) FX Fixed SL Revolving / Swivel Stem Length (elow thread Max. 00 mm) Refer range table Type ST With rigid stem CP With capillary Capillary length (Max up to Mtrs.) Capillary S4 ISI 04 SS 80 00 mm Minimum stem Length (elow Thread) 0 mm 00 mm 00 mm 80 mm Stem OD mm 8 mm 0 mm mm In meters (e.g.. =. meters.0 = meters) S ISI SS Capillary covered with armour (pplicable with S4 or S if selected) S4 ISI 04 SS S ISI SS Electric Contacts (FOR 00 mm & mm Only) ( mm SD04 4 mm SD0 mm (Standard) SD08 8 mm SD0 0 mm SD mm PV pproved) (With IP protection up to IP & window polycarbonate dome type) PVC (mbient Temp. Max. 0 C) 00 mm Example or X X X 00 mm 0/00 C Mtr. ) Single insulated magnetic snap action type (0 V C, mp.) (48 V DC, 0. mp.) (vailable for kg/cm² & above) M M M M4 M M Single; normally closed ( NC) Double; normally closed + normally open ( NC + NO) Single; normally open ( NO) Double; normally open + normally closed ( NO + NC) Double; normally closed (both NC) Double; normally open (both NO) ) Inductive type (0 V C, 0.4 mp.) (vailable for 000 mm WC & above ) D D D D4 D D Single; normally open ( NO) Single; normally closed ( NC) Double; normally closed + normally open ( NC + NO) Double; normally open (both NO) Double; normally closed (both NC) Double; normally open + normally closed ( NO + NC) Optional Extras CS ISI SS case & bezel LGF Dampening liquid glycerin filled ( ambient temp. Max. C) LSI Dampening liquid silicon oil ( ambient temp. bove C) MRP Maximum reading pointer with plexi glass (for dry version) MTC Material test certificates# CDD STG TND STP DOF Custom designed dial Shatterproof/safety glass Tag No. marking on Dial SS tag plate Dielectric oil filled X Dry version & except electrical contacts. vailable for 00 mm to mm. Consult factory for minimum order quantity & delivery. Gasket & Filling plug of Viton. # Material test certificates will be provided for wetted parts only with chemical composition testing. For others, please consult factory. Five Point Calibration Certificate Provided With Each Gauge For Measuring Only. 0 Ordering Example - or X - X - X - - - 00 mm - 0/00 C - - Mtr - - - - X For other optional items, please contact factory for delivery and minimum quantity of order. Note Specifications and dimensions given in this product catalogue represents the state of engineering at the time of printing. Modifications may take place and materials specified may be replaced by others without prior notice. Issue. 0/0/0 Design and specifications are subject to change without prior notice Page /