HEAT TRANSFER ENHANCEMENT BY V-NOZZLE TURBULATORS

Similar documents
HEAT TRANSFER ENHANCEMENT BY USING TWISTED TAPE INSERTS WITH CIRCULAR HOLES IN FORCED CONVECTION

Visualization of Flow and Heat Transfer in Tube with Twisted Tape Consisting of Alternate Axis

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

Experimental Study of Heat Transfer Augmentation in Concentric Tube Heat Exchanger with Different Twist Ratio of Perforated Twisted Tape Inserts

Experimental Investigation of Heat Transfer characteristics Enhancement through Grooved Tube

NOVATEUR PUBLICATIONS INTERNATIONAL JOURNAL OF INNOVATIONS IN ENGINEERING RESEARCH AND TECHNOLOGY [IJIERT] VOLUME 1, ISSUE 1 NOV-2014

Heat Transfer Enhancement for Double Pipe Heat Exchanger Using Twisted Wire Brush Inserts

EXPERIMENTAL INVESTIGATIONS OF DOUBLE PIPE HEAT EXCHANGER WITH TRIANGULAR BAFFLES

Heat Transfer Enhancement In Pipe With Passive Enhancement Technique

An Approach for Enhancement of Heat Transfer Using Conical Convergent Ring Inserts In Tube

Comparison of Heat transfer Enhancement in Tube in Tube heat exchanger using Different Turbulent Generator.

International Journal of Scientific & Engineering Research, Volume 6, Issue 10, October ISSN

Department of Mechanical Engineering, D Y Patil College of Engineering, Akurdi, Pune , Savitribai Phule Pune University, India

Enhance the Performance of Heat Exchanger with Twisted Tape Insert: A Review

Experimental Investigation on Turbulent Flow Heat Transfer in a Horizontal Circular Pipe using Coil and Twisted Tape Inserts

International Journal of Advance Engineering and Research Development

Experimental Study of Heat Transfer Enhancement in a Heated tube Caused by Wire-Coil and Rings

Simulation Studies on the Effect of Porous Twisted Plate Inserts on the Performance of Fire Tube Steam Packaged Boiler

EFFECT OF EXTERNAL THREADED INSIDE TUBE ON HEAT TRANSFER RATE IN A CONCENTRIC TUBE HEAT EXCHANGER: A CRITICAL REVIEW

Numerical Investigation of Convective Heat Transfer and Pressure Loss in a Round tube Fitted with Circular-Ring Turbulators

HEAT TRANSFER ENHANCEMENT IN A CIRCULAR TUBE FOR TURBULENT FLOW OF WATER USING PERFORATED RECTANGULAR STRIPE INSERT

CFD Analysis of Double Pipe Heat Exchanger with Twisted Tape Insert in Inner Pipe

An Experimental Study of Thermo-Hydraulic Performance of Modified Double Pipe Heat Exchanger Using Mesh Inserts

Experimental Analysis of Heat Transfer and Friction Factor Characteristics in Turbulent Flow through a Tube Fitted with Screw Tape

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

ENHANCEMENT OF HEAT TRANSFER IN SHELL AND TUBE HEAT EXCHANGER WITH TABULATOR AND NANOFLUID

Heat transfer enhancement of a single row of tube

Enhanced Heat Transfer Surface Development for Exterior Tube Surfaces

SINGLE-PHASE CONVECTIVE HEAT TRANSFER AND PRESSURE DROP COEFFICIENTS IN CONCENTRIC ANNULI

FLOW AND HEAT TRANSFER ENHANCEMENT AROUND STAGGERED TUBES USING RECTANGULAR VORTEX GENERATORS

Experimental Analysis and Performance Characteristic Of Heat Transfer In Shell and Twisted Tube Heat Exchanger.

Design, Fabrication and Testing of helical tube in tube coil heat exachanger

Heat Transfer Augmentation Technique Using Twisted Tape Insert

AUGMENTATION OF TURBULENT FLOW HEAT TRANSFER IN A HORIZONTAL TUBE WITH VARYING WIDTH TWISTED TAPE INSERTS

PERFORMANCE ANALYSIS ON DOUBLE PIPE HEAT EXCHANGER USING WIRE COILED AND PIN WIRE COILED TURBULATOR INSERTS

ABSTRACT I. INTRODUCTION III. GEOMETRIC MODELING II. LITERATURE REVIW

ENHANCEMENT OF HEAT TRANSFER COEFFICIENT THROUGH HELICAL COIL

THERMAL ANALYSIS OF HELICALLY GROOVED COIL IN A CONCENTRIC TUBE HEAT EXCHANGER

EXPERIMENTAL ANALYSIS AND PERFORMANCE CHARACTERISTIC OF HEAT TRANSFER IN SHELL AND TWISTED TUBE HEAT EXCHANGER

Flow Characteristics of Air in Square Channel Using Perforated Ribs

Analysis to Determine Heat Transfer Using Twisted Tape Inserts In a Horizontal Tube

Single-phase Coolant Flow and Heat Transfer

Abstract In this study the heat transfer characteristics inside a rectangular duct with circular, rectangular, drop

CFD Analysis and Comparison of Fluid Flow Through A Single Hole And Multi Hole Orifice Plate

ADVANCES in NATURAL and APPLIED SCIENCES

TEMPERATURE APPROACH OPTIMIZATION IN THE DOUBLE PIPE HEAT EXCHANGER WITH GROOVE

Design and experimental analysis of pipe in pipe heat exchanger

CONJUGATE HEAT TRANSFER ANALYSIS OF HELICAL COIL HEAT EXCHANGE USING CFD

Heat Exchangers (Chapter 5)

NUMERICAL INVESTIGATION OF PISTON COOLING USING SINGLE CIRCULAR OIL JET IMPINGEMENT

Forced Convection Heat Transfer Analysis through Dimpled Surfaces with Different Arrangements

CFD analysis of heat transfer enhancement in helical coil heat exchanger by varying helix angle

COMPUTATIONAL ANALYSIS TO MAXIMIZE THE HEAT TRANSFER RATE OF DOUBLE TUBE HELICAL COIL HEAT EXCHANGER

International Research Journal of Engineering and Technology (IRJET) e-issn:

Experimental investigation of shell-and-tube heat exchanger with different type of baffles

Optimisation of Double Pipe Helical Tube Heat Exchanger and its Comparison with Straight Double Tube Heat Exchanger

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March ISSN

Prediction of Thermal Deflection at Spindle Nose-tool Holder Interface in HSM

Experimental Study of Heat Transfer Enhancement in Tube in Tube Heat Exchanger using Rectangular Wing Type Vortex Generator

HEAT TRANSFER AUGMENTATION OF LAMINAR NANOFLUID FLOW IN HORIZONTAL TUBE INSERTED WITH TWISTED TAPES

Numerical and Experimental Investigations of Heat Transfer in Double Pipe Heat Exchangers with Inner and Annular Twisted Tape

Flow Behavior and Friction Factor. in Internally Grooved Pipe Wall

CFD ANALYSIS ON LOUVERED FIN

Cross Flow Heat Exchanger H352

Effect of Nanofluid on Friction Factor of Pipe and Pipe Fittings: Part I - Effect of Aluminum Oxide Nanofluid

An Experimental Investigation for the Rate of Heat Transfer in Double Pipe Heat Exchanger with Fins on Inside Surface of Internal Tube

Thermal Stress Analysis of Diesel Engine Piston

THERMAL ANALYSIS OF PISTON BLOCK USING FINITE ELEMENT ANALYSIS

A REVIEW ON INVESTIGATION OF HELICAL COIL HEAT EXCHANGER

Thermal Analysis of Shell and Tube Heat Exchanger Using Different Fin Cross Section

SWIRL MEASURING EQUIPMENT FOR DIRECT INJECTION DIESEL ENGINE

Experimental Investigation on Mixing time Analysis of Jet Mixer

Study on Flow Fields in Variable Area Nozzles for Radial Turbines

Modeling and Fluid Flow Analysis of Wavy Fin Based Automotive Radiator

Cross Flow Heat Exchanger H352

Exhaust Gas Waste Heat Recovery and Utilization System in IC Engine

Experimental Investigation on Forced Convection Heat Transfer Augmentation Using Annular Blockages

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

THERMAL TO MECHANICAL ENERGY CONVERSION: ENGINES AND REQUIREMENTS Vol. I - Thermal Protection of Power Plants - B.M.Galitseyskiy

Heat Transfer Enhancement of Perforated Square Pin-Fin Array in a Rectangular Duct

Design and Performance Analysis of Louvered Fin Automotive Radiator using CAE Tools

CRITICAL ASSESSMENT OF LITERATURE IN THE FIELD OF ENHANCED HEAT TRANSFER TECHNIQUES

Civil Engineering Hydraulics. Radial Flow Devices

Experimental Investigation on Modification of Inlet poppet valve of single cylinder Direct Ignition Four stroke Diesel Engine

Experimental Investigation on Effect of Fin Shape on the Thermal-Hydraulic Performance of Compact Fin-and-Tube Heat Exchangers

Review on Comparative Study between Straight Tube Heat Exchanger and Helical Coil Heat Exchanger

HEAT TRANSFER ENHANCEMENT USING DIFFERENT GEOMETRY OF TWIST TAPE TURBULATORS: A REVIEW

CFD Investigation of Influence of Tube Bundle Cross-Section over Pressure Drop and Heat Transfer Rate

Heat transfer and friction characteristics of rotor-assembled strand heat exchanger studied by uniform design experiment

A Review on Experimental Investigation of U-Tube Heat Exchanger using Plain Tube and Corrugated Tube

Design and Fabrication of Shell and Tube Type Heat Exchanger and Performance Analysis

INVESTIGATION OF HEAT TRANSFER CHARACTERISTICS OF CIRCULAR AND DIAMOND PILLARED VANE DISC BRAKE ROTOR USING CFD

Design and Performance Study of Shell and Tube Heat Exchanger with Single Segmental Baffle Having Perpendicular & Parallel-Cut Orientation.

GEOMETRICAL PARAMETERS BASED OPTIMIZATION OF HEAT TRANSFER RATE IN DOUBLE PIPE HEAT EXCHANGER USING TAGUCHI METHOD D.

Heat Transfer in Rectangular Duct with Inserts of Triangular Duct Plate Fin Array

Performance of Solar Flat plate by using Semi- Circular Cross Sectional Tube

Cooldown Measurements in a Standing Wave Thermoacoustic Refrigerator

FLUID FLOW. Introduction

International Journal of Engineering Research-Online A Peer Reviewed International Journal Articles available online

Effect of Helix Parameter Modification on Flow Characteristics of CIDI Diesel Engine Helical Intake Port

Transcription:

HEAT TRANSFER ENHANCEMENT BY V-NOZZLE TURBULATORS Deepali S. Bankar Lecturer, Automobile Engineering Department G. H. Raisoni Polytechnic Nagpur (Maharashtra), India bankardeepali@gmail.com Abstract The effects of V-nozzle inserts on heat transfer and friction characteristics in a uniform heat flux tube are experimentally studied. The V-nozzle with pitch ratio 5.0 used. Experimental investigations have been carried out to study the effects of the V-nozzle turbulators on heat transfer augumentation, friction and enhancement efficiency, in a circular tube. It is found that using the V-nozzle can help to increase considerably the heat transfer rate at about 140% over the plain tube. A maximum gain of 1.19 on enhancement efficiency is obtained for the pitch ratio used, PR=5.0. This indicates that the effect of the reverse/re-circulation flows can improve the heat transfer rate in the tube. In addition, correlations from the results are presented. Keywords- Heat transfer enhancement, turbulators, v-nozzle. I. INTRODUCTION Heat transfer enhancement is the process of improving the performance of a heat transfer system. It generally means increasing the heat transfer coefficient. The performance of heat exchanger depends how effectively heat is utilized. The high performance of heat exchangers are very much essential in many practical applications such as aerospace, vehicles, refrigeration and air conditioning, cooling of electric equipment and so on. Reduction of the size of the heat exchanger may be possible due to improvement in the performance of heat exchanger. On the other hand, a high performance heat exchanger of a fixed size can give a increased heat transfer rate and also there is decrease in temperature difference between the process fluids enabling efficient utilization of thermodynamic availability. The performance can be improved by using various augmentation techniques such as finned surfaces, integral roughness and insert devices. A variety of different techniques are employed for the heat transfer process. Many active and passive techniques are currently being employed in heat exchangers, with twisted tape inserts providing a cost-effective and efficient means of augmenting heat transfer. The reverse flow device or the turbulator is widely employed in heat transfer engineering applications. The reverse flow is sometimes called re-circulation flow. The effect of reverse flow and boundary layer eruption (dissipation) is to enhance the heat transfer coefficient and momentum transfers. The reverse flow with high turbulent flow can improve convection of the tube wall by increasing the effective axial Reynolds number, decreasing the cross-section flow area, and increasing the mean velocity and temperature gradient. It can help to produce the higher heat fluxes and momentum transfer due to the large effective driving potential force but also higher pressure drop. The strengths of reverse flow and the reattached position ORGANISED BY:G. H. RAISONI POLYTECHNIC, NAGPUR - IN ASSOCIATION WITH : AES Page 733

are the main interest in many heat transfer applications such as heat exchangers, combustion chambers, gas turbine blades, and electronic devices. Figure 1 Schematic representation of experimental setup II Experimental Setup The experiments were carried out in an open-loop experimental facility as shown in Fig. 1. The loop consisted of a 0.75 kw blower, orifice meter to measure the flow rate, and the heat transfer test section. The copper test tube has a length of L=1250 mm, with 44.5 mm Figure 2 V-NOZZLE Turbulator inner diameter (D), 49.5 mm outer diameter (Do), and 2.5 mm thickness (t) as depicted in Fig. 2. The tube was heated by continually winding flexible electrical wire to provide a uniform heat flux boundary condition. The electrical output power was controlled by a variance transformer to obtain a constant heat flux along the entire length of the test section and by keeping the current less than 3 A. The outer surface of the test tube was well insulated to minimize convective heat loss to surroundings, and necessary precautions were taken to ORGANISED BY:G. H. RAISONI POLYTECHNIC, NAGPUR - IN ASSOCIATION WITH : AES Page 734

prevent leakages from the system. The inner and outer temperatures of the bulk air were measured at certain points with a multichannel temperature measurement unit in conjunction with the thermocouples as can be seen in Fig. 2. Six thermocouples were tapped on the local wall of the tube and the thermocouples were laced round the tube to measure the circumferential temperature variation, which was found to be negligible. The mean local wall temperature was determined by means of calculations based on the reading of thermocouples. Fig. 2 represents the V-nozzle arrangement used in the present work. The V-nozzle was made of Mild steel 180 mm in length and its end and throat diameters were 35 mm and 24 mm, respectively. The V-nozzles were placed with pitch ratio PR=5.0 with pitch lengths, l=180 mm for experiment. Figure 3 Experimental Setup Figure 4 Fabricated V-nozzle In the apparatus setting above, the inlet bulk air at 25 C from a 0.75 kw blower was directed through the orifice meter and passed to the heat transfer test section. The air flow ORGANISED BY:G. H. RAISONI POLYTECHNIC, NAGPUR - IN ASSOCIATION WITH : AES Page 735

rate was measured by an orifice meter, built according to ASME standard. Manometric fluid was used in U-tube manometers with specific gravity (SG) of 0.981 to ensure reasonably accurate measurement of the low pressure drop encountered at low Reynolds numbers. Also, the pressure drop of the heat transfer test tube was measured with inclined U-tube manometers. The volumetric air flow rates from the blower were adjusted by varying motor speed through the inverter, situated before the inlet of test tube. During the experiments, the the inlet and outlet temperatures of the bulk air from the tube were measured by multichannel Chromel constantan thermocouples. It was necessary to measure the temperature at 8 stations altogether on the outer surface of the heat transfer test pipe for finding out the average Nusselt number. For each test run, it was necessary to record the data of temperature, volumetric flow rate and pressure drop of the bulk air at steady state conditions in which the inlet air temperature was maintained at 25 C. The Reynolds number of the bulk air was varied from 8000 to 18000. The various characteristics of the flow, the Nusselt number, and the Reynolds number were based on the average of tube wall temperatures and outlet air temperature. The local wall temperature, inlet and outlet air temperatures, the pressure drop across the test section and air flow velocity were measured for heat transfer of the heated tube with V-nozzles. The average Nusselt numbers were calculated and discussed where all fluid properties were determined at the overall bulk mean temperature. The experiments are conducted on test rig and bulk air was heated by an adjustable electrical heater wrapping along the test section. Both 3.5 calculations In the present work, the air is used as working fluid and flowed through a uniform heat flux and insulation tube. The steady state of the heat transfer rate is assumed to be equal to the heat loss from the test section which can be expressed as: Qair = Qconv in which Qair = mcpa(to Ti) The convection heat transfer from the test section can be written as: Qconv = ha(tw Tb) Where as, Tb = (To-Ti)/2 And Tw = Tw/6 where Tw is the local wall temperature and evaluated at the outer wall surface of the inner tube. The averaged wall temperatures are calculated from 6 points, lined between the inlet and the exit of the test pipe. The average heat transfer coefficient, h and the mean Nusselt number, Nu are estimated as follows: ORGANISED BY:G. H. RAISONI POLYTECHNIC, NAGPUR - IN ASSOCIATION WITH : AES Page 736

h = mcpa (To-Ti)/A(Tw-Tb) Nu = hd/k The Reynolds number is given by Re = UD/v Experimental Results The experiments were conducted on the test rig initially with the plane circular pipe and the different heat transfer characteristic were calculated and then the same is done for the v-nozzle. The air supply can be controlled by the valve and various mass flow rate are provided for which the heat transfer characteristics are calculated. The graph shows the relations between Reynolds no and nusselt no. the nusselt no increases with the increase in the Reynolds no. and the Reynolds no increases in the v-nozzle. The graph shows the relations between Reynolds no and heat transfer coefficient. The heat transfer coefficient increases with the increase in the Reynolds no. and the friction factor increases in the v-nozzle. ORGANISED BY:G. H. RAISONI POLYTECHNIC, NAGPUR - IN ASSOCIATION WITH : AES Page 737

Conclusion Experimental investigations have been carried out to study the effects of the V-nozzle turbulators on heat transfer, and enhancement efficiency, in a circular tube. We used the v-nozzle with the pitch ratio of 5.12 and we found the heat transfer argumentation. The results are 1. The heat transfer in the circular tube could be promoted by fitting with V-nozzles while it brings about the energy loss of the fluid flow. The mean heat transfer rates obtained from using the V-nozzles 147% over the plain tube. However, the increase in friction factor is much higher than the increase in Nusselt number at the same Reynolds number. 2. The enhancement efficiency decreases with increasing Reynolds number. The maximum value of enhancement efficiency obtained from using the 1.09. References 1. Experimental investigation of heat transfer and friction characteristics in a circular tube fitted with V-NOZZLE TURBULATORS. by S. Eiamsa-ard, P. Promvonge b, 2. Heat transfer and turbulent flow friction in a circular tube fitted with CONICAL- NOZZLE TURBULATORS by Pongjet Promvonge a, Smith Eiamsa-ard. 3. Heat transfer augmentation in a circular tube using V-nozzle turbulator inserts and snail entry Pongjet Promvonge a,*, Smith Eiamsa-ard b,. 4. Heat transfer enhancement in a tube with combined conical-nozzle inserts and swirl generator P. Promvonge *, S. Eiamsa-ard. 5. Heat transfer in a circular tube fitted with free-spacing snail entry and conical-nozzle turbulators P. Promvonge a,, S. Eiamsa-ard b. 6. Thermal augmentation in circular tube with twisted tape and wire coil turbulators Pongjet Promvonge * 7. Heat transfer behaviors in round tube with conical ring inserts P. Promvonge * 8. Heat transfer behaviors in a tube with combined conical-ring an twisted-tape insert P. Promvonge a,, S. Eiamsa-ard b. 9. Heat transfer augmentation by swirl generators inserted into a tube with constant heat flux İrfan Kurtbaş a,, Fevzi Gülçimen b, Abdullah Akbulut c, Dinçer Buran d. 10. Flow-induced vibration analysis of conical rings used for heat transfer enhancement in heat exchangers Kenan Yakut*, Bayram Sahin. 11. Heat transfer enhancement in a tube using circular cross sectional rings separated from wall Veysel Ozceyhan a,*, Sibel Gunes a, Orhan Buyukalaca b, Necdet Altuntop a. 12. The investigation of groove geometry effect on heat transfer for internally grooved tubes Kadir Bilen a,*, Murat Cetin b, Hasan Gul c, Tuba Balta a. 13. Heat transfer a review of 2000 literature R.J. Goldstein *, E.R.G. Eckert, W.E. Ibele, S.V. Patankar, T.W. Simon, T.H. Kuehn, P.J. Strykowski, K.K. Tamma, A. Bar-Cohen, J.V.R. Heberlein, J.H. Davidson, J. Bischof, F.A. Kulacki, U. Kortshagen, S. Garrick. ORGANISED BY:G. H. RAISONI POLYTECHNIC, NAGPUR - IN ASSOCIATION WITH : AES Page 738