YS Series Contactors YS1N- F11 ****

Similar documents
IEC Contactors. IEC Contactors. YS Series. YS Series Contactors YS1N- F11 ****

Section. IEC Contactors Selection Guide...D-3. Non-Reversing Contactors YS1N AC Controlled...D-5 YS3N DC Controlled...

AF40... AF96 3-pole contactors Technical data

RY2L Series Miniature Magnetic Latching Relays. E Release Time. 60N (0 6G); Maximum frequency 55Hz

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

Industrial Contactors CTX 3 3P 185A - 800A

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

C -5 to +55 (0.8 to 1.1Uc) Permissible o

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Locking Style mm AUTOCAD, STEP, IGES & PDF. Kits Actuator Type Interlock Kit Model * Contact(s) SI-LS42DMSG SI-LS42WMSG

Definite Purpose Contactors Types DP, DPA, and SYD Class 8910

Micro Contactor MA Series

High Performance Thermal-Magnetic Circuit Breakers 410/520/

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

Application Mini Contactors for Motors and Resistive Loads

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Essential equipment for all your requirements

Manual Motor Starters. Meta-MEC

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

Ktec Contactors and thermal overloads

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

ASL09..S 3-pole Contactors - Spring Terminals

CI-TI Contactors and motor starters Types CI 61 - CI 98

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Thermal-Magnetic Circuit Breaker 201/-WA

Door Interlock Switches

Technical Information

General technical data: CONTACTOR, AC-3, 5.5KW/400V, 1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S00 SCREW TERMINAL. product brand name

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

3 - Protection components Motor circuit-breakers

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

XMC0 Series. Definite Purpose Contactors

B Mini Contactor V Hz

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

Oiltight Switches & Pilot Devices

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

General technical data: CONTACTOR, AC-3, 11KW/400V, 1NO+1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S0 SCREW TERMINAL. product brand name

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

AF series contactors (9 2650)

Short form catalogue. Motor protection & control

4 - Miniature controls

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

XCS Safety Interlock Selection

Relays. Industrial Automation Catalog Section - U906. Selection Guides. General Purpose Relays RU Series RR Series

Star Series Motor protection & control

JOSLYN CLARK VACUUM CONTACTORS

Modular contactors and relays

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Mini contactors. Mini contactors providing various connections and Accessories. Screw clamps. Ratings. For fast-on connections

Technical Information

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Application Mini Contactors for Motors and Resistive Loads

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Relays. Industrial Automation Catalog Section - U906. Selection Guides. Solid State Relays RSS Series

Quick selection table

AF series contactors (9 2650)

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

MINIATURE CIRCUIT BREAKER

Application Description

Multi-function. Mono-function 1 NO (SPST-NO)

TAE pole Contactors

NEMA Contactors & Starters (Freedom)

General technical data: CONTACTOR, AC-3, 4KW/400V, 2NO+2NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL REMOVABLE AUX. SWITCH. product brand name

Oiltight Switches & Pilot Devices

XMC0 Series DEFINITE PURPOSE CONTACTORS

Standard voltages. Alternating current (V) /60Hz Alternating current (V)

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

CB to 1000 A. 1 to 4 single pin main poles with silver pad contacts.

JOSLYN CLARK VACUUM CONTACTOR FEATURES

FMotor Circuit Controllers

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads.

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

D509E. Manual Motor - Starters

General technical data: CONTACTOR, AC-3, 18.5KW/400V, 1NO+1NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL. product brand name

LK Position Switches TECHNICAL DATASHEET.

Mini contactors B6, BC6 with 3 pole

MS Overview. General purpose contactors. MS Overview. General purpose contactors. The main benefits: Handling of the contactors

Industrial contactors CTX-1

AE 9... AE 40 Contactors NE... Contactor Relays

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters

General information about motor protection

Safety switches for hinged doors

Series CK. Contactors. Intro. Mounting positions

Meta Solution. Contactors and Overload relays

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

Thermal overload relays Type TA Class 10

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Transcription:

YS Series YS Series Contactors Key features of the YS Series include: Compact size AC and C coil, reversing and non-reversing Weld-resistant silver alloy contacts No cadium used in contacts Highly reliable auxiliary contacts use bifurcated double bridge contact form irect panel mount with screws or 35mm IN rail (9F to 65F) Conforms to IEC standards: EN947-1, EN947-4-1, EN-947-5-1 Approval standards: UL8 (UL File No. E67770, E184169) CE Certified Ordering Information IEC CONTACTORS Specify the maximum AC3 current code for the contactor in place of. Specify the coil voltage code for the contactor in place of ****. This part number is not indicated on the label of the contactor. YS1N- F11 **** Completed Part Number of Contactors 1 Product Series YS1N: Non- reversing contactor, AC controlled YS1R: Reversing contactor, AC controlled YS3N: Non-reversing contactor, C controlled YS3R: Reversing contactor, C controlled 2 a) Approximate Maximum AC3 Current AC or C Controlled Contactors 9:9A, 12:12A, 20:20A, 25:25A, 32:32A, 38:38A, 40:40A, :A, 65:65A, 80:80A, 100:100A, 125:125A AC Contactors Only 1:1A, 180:180A, 220:220A, 300:300A b) Type of Contactor 4 Coil Voltage (Rated Voltage and Frequency) A024 : AC24V /Hz A048 : AC48V /Hz A110 : AC110V /Hz A120 : AC120V /Hz A230 : AC230V /Hz A240 : AC240V /Hz A380 : AC380V /Hz A415 : AC415V /Hz A480 : AC480V /Hz A0 : AC0V /Hz 024 : C 24V 048 : C 48V 110 : C 110V 220 : C 220V M100 : C 110V M200 : C 220V (Other Voltages Available, Contact IEC) AC Contactors (all sizes) C Contactors (sizes 9-65) C Contactors (sizes 80-125) F: AC controlled all sizes FG2: C Controlled, sizes 9-65 FG: C Controlled, sizes 80-125 3 Auxiliary Contact Configuration (Built onto conctactor) 01: with 1NC, only for contactors sizes 9F-12F 10: with 1NO, only for contactors sizes 9F-12F 11: with 1NO-1NC, only for contactors sizes 20F-65F 22: with 2NO-2NC, only for contactors sizes 80F-300F Notes: 1. Use the above ordering information only when interpreting part numbers. o not use for developing part numbers. 2. Please see tables on following pages for proper selection. 3. For specifications please see page -16 through page -34. -4 www.idec.com USA: (800) 262-IEC or (408) 747-05, Canada: (888) 317-IEC Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (6) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

YS Series YS1N Non-Reversing AC Contactors, AC Controlled AC1 I e (Amps) AC3 kw AC3 Rating EN 974-4-1 HP Rating per UL8 Auxiliary 3 Phase 1 Phase 3 Phase Contacts 220-230V 380-400V 0V 6-690V 120V 230V 200-208V 220-240V 440-480V 20 8.5 2.2 4 5.5 5.5 1/3 1 2 2 5 5 5-0V N.O. N.C. Part Number 0 1 YS1N-9F01**** 1 0 YS1N-9F10**** 20 11.5 3 5.5 7.5 7.5 3/4 2 3 3 7.5 5 0 1 YS1N-12F01**** 1 0 YS1N-12F10**** 30 15.5 4 7.5 10 10 1 3 5 5 10 13.5 1 1 YS1N-20F11**** 30 22 5.5 11 15 15 2 3 7.5 7.5 15 15 1 1 YS1N-25F11**** 30 7.5 15 18.5 18.5 2 5 7.5 10 20 20 1 1 YS1N-32F11**** 37 11 18.5 22 30 3 7.5 10 15 30 30 1 1 YS1N-38F11**** 37 11 18.5 22 30 3 7.5 10 15 30 30 1 1 YS1N-40F11**** 80 44 15 22 30 33 3 7.5 10 15 40 40 1 1 YS1N-F11**** 80 18.5 30 37 37 5 10 20 20 40 1 1 YS1N-65F11**** 135 85 22 45 55 45 7.5 15 25 25 2 2 YS1N-80F22**** 1 105 30 55 65 65 - - 30 35 75 2 2 YS1N-100F22**** 1 37 75 75 - - 40 100 100 2 2 YS1N-125F22**** 200 138 45 75 90 100 - - 40 100 125 2 2 YS1N-1F22**** 240 179 55 95 110 110 - - 125 125 2 2 YS1N-180F22**** 2 205 65 110 - - 75 1 1 2 2 YS1N-220F22**** 3 300 90 1 1 200 - - 75 100 200 200 2 2 YS1N-300F22**** Codes for Control Circuit AC Voltages / Hz Volts AC / Hz 24 48 120 220 240 380 415 480 Code to replace **** A024 A048 A120 A220 A240 A380 A415 A480 Consult an IEC representative for other coil voltages. For accessories, see page -12. For specifications, see page -16 through -34. For dimensions, see pages -35. For other application tables, see page -51. www.idec.com USA: (800) 262-IEC or (408) 747-05, Canada: (888) 317-IEC -5 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (6) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Specifications Specifications Contactor Circuit Supply: AC Characteristics Part Number YS1N 9F 12F 20F 25F 32F 38F 40F F 65F 80F 100F 125F 1F 180F 220F 300F Rated Insulation Voltage V 690 690 690 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 Conformity to Standards Approvals NFC 63-110; VE 06; BS 5424; JEM 1038; EN947-1, 947-4-1; UL8 UL, c-ul egree of Protection Finger-safe (according to VE 0106) ry Ambient Air Temp. for Storage 1/4C -40 to +80 ry Ambient Air Temp. for Operation 1/4C -10 to +55 (0.85 to 1.1 Un) Operating Altitude m 2000 Operating Position (without derating Main Power Pole Utilization Characteristics: ±301/4 compared with the normal vertical mounting plane (see table on -22) Number of Poles: 3 Part No. 9F 12F 20F 25F 32F 38F 40F F 65F 80F 100F 125F 1F 180F 220F 300F Rated Operational Current in AC3 A 9 12 18 25 30 40 40 65 80 105 125 1 180 220 300 in AC1 A 20 20 30 30 80 80 135 1 1 200 240 2 3 Rated Operational Voltage V 6 6 690 690 690 690 690 690 690 690 690 690 690 690 690 690 Maximum Thermal Current Ith ( 55 C) A 20 20 35 35 80 80 135 1 1 200 240 2 3 Making Capacity I rms A 1 1 280 300 480 480 800 800 800 10 10 10 1800 2100 20 30 Breaking Capacity 220-380- 415-440V A 120 1 2 300 380 480 0 0 700 800 1100 1300 10 1800 2100 3000 I rms 0V A 100 120 200 2 300 400 400 0 5 800 1000 1100 1200 10 1900 2200 According to EN 158-1 6-690V A 90 100 120 180 2 3 3 400 430 0 7 0 1100 1200 1400 1800 Wiring, minimum-maximum wire size: Stranded Wire (without ferrule) 1 Conductor 2 Conductors mm 2 1-4 1-4 1.5-10 1.5-10 4-16 4-16 5-25 5-25 5-25 8-8- 8-8-100 8-100 14-1 14-1 AWG 18-10 18-10 16-8 16-8 12-6 12-6 10-3 10-3 10-3 8-0 8-0 8-0 8-4/0 8-4/0 4-300mcm 4-300mcm mm 2 1-4 1-4 1.5-6 1.5-6 4-8 4-8 5-16 5-16 5-16 8-35 8-35 8-35 8-8- 14-80 14-80 AWG 18-10 18-10 16-10 16-10 12-8 12-8 10-5 10-5 10-5 8-2 8-2 8-2 8-1 8-1 4-3/0 4-3/0 Solid Wire (without ferrule) 1 Conductor 2 Conductors mm 2 1-4 1-4 1.5-6 1.5-6 4-10 4-10 5-25 5-25 5-25 AWG 18-10 18-10 16-10 16-10 12-8 12-8 10-3 10-3 10-3 mm 2 1-4 1-4 1.5-6 1.5-6 4-10 4-10 5-16 5-16 5-16 AWG 18-10 18-10 16-10 16-10 12-8 12-8 10-5 10-5 10-5 -16 www.idec.com USA: (800) 262-IEC or (408) 747-05, Canada: (888) 317-IEC Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (6) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Specifications Control Circuit Characteristics: Part Number YS1N- 9F 12F 20F 25F 32F 38F 40F F 65F 80F 100F 125F 1F 180F 220F 300F Rated AC Control Voltage ( or Hz) : Un V Un: 24 to 0 Coil Limits ( 55 C) Operating Limits Un 85% to 110% Un rop-out Voltage Un 30% to 70% Un Coil Power Consumption (20 C) in Un Inrush VA 55 55 85 85 1 1 170 170 170 276 276 276 819 819 805 805 AC Hz Cos Ø (power factor) 0.8 0.8 0.8 0.8 0.7 0.7 0.6 0.6 0.6 0.5 0.5 0.5 0.5 0.5 0.2 0.2 Sealed VA 8 8 8 8 15 15 16 16 16 40 40 40 53 53 100 100 AC Hz Coil Power Consumption Cos Ø (power factor) 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.37 0.37 Inrush VA 80 80 130 130 1 1 1 231 231 231 714 714 700 700 Cos Ø (power factor) 0.7 0.7 0.7 0.7 0.6 0.6 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.21 0.21 Sealed VA 6 6 6 6 12 12 13 13 13 29 29 29 38 38 88 88 Cos Ø (power factor) 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.37 0.37 Hz W 1.5 to 2.5 1.5 to 2.5 1.5 to 2.5 1.5 to 2.5 3.5 to 5.0 3.5 to 5.0 3.7 to 5.2 3.7 to 5.2 3.7 to 5.2 7.5 to 11 7.5 to 11 7.5 to 11 12 to 16 12 to 16 19 to 27 19 to 27 Hz W 1.0 to 2.0 1.0 to 2.0 1.0 to 2.0 1.0 to 2.0 3.0 to 4.5 3.0 to 4.5 3.0 to 4.5 3.0 to 4.5 3.0 to 4.5 6.0 to 8.5 6.0 to 8.5 6.0 to 8.5 9.0 to 13 9.0 to 13 16 to 23 16 to 23 Mechanical Life at Rated Control Voltage (Un) ( 10 6 operating cycles) 10 10 10 10 5 5 5 5 5 5 5 5 5 5 5 5 Switching Frequency Minimum-Maximum Wire Size Mechanical 9000 9000 9000 9000 9000 9000 9000 9000 9000 7200 7200 7200 7200 7200 00 00 ops/h Electrical AC3 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 Stranded Wire (without ferrule) Solid Wire (without ferrule) 1 Conductor 2 Conductors 1 Conductor 2 Conductors mm 2 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 AWG 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 mm 2 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 AWG 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 mm 2 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 AWG 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 mm 2 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 1-4 AWG 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 18-10 www.idec.com USA: (800) 262-IEC or (408) 747-05, Canada: (888) 317-IEC -17 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (6) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Specifications Coil Resistance: Coil Voltage Resistance (Ω) YS1N-9F/12F YS1N-20F/25F YS1N-32F/38F YS1N-40F/F/65F YS1N-80F/100F/125F YS1N-1F/180F YS1N-220F/300F 24V /Hz 7.90 4.8 1.68 1.7 0.39 0.298 0.107 48V /Hz 33.9 19.1 7.1 6.3 1.85 1.1 0.3 110V /Hz 174.4 101 36.6 39.1 8.67 6.46 2.630 120V /Hz 1.3 122 44.2 45.2 11.6 7.1 3.186 208V /Hz 619.5 385.4 33.3 23.2 8.310 220V /Hz 748.0 397 153 139.0 35.6 24.8 8.840 230V /Hz 776.0 486 153 162.0 37.2 30 9.340 240V /Hz 841.8 513 164 177.8 45.6 31.4 9.810 380V /Hz 2577.0 1310 458 426.0 112 22.38 415V /Hz 21.1 1480 1 562.5 133.6 28.70 480V /Hz 3166.4 20 675 757.1 1 129.2 62.71 0V /Hz 3272.7 2170 790 794.0 191 135.2 66.52 0V /Hz 5136.3 3100 1162 1046.7 275 206 100.3 Operating Time: Frame Size Contactor Hz Hz Basic Part Number Main Closing (msec) Opening (msec) Closing (msec) Opening (msec) (NO) (NC) Main (NO) (NC) Main (NO) (NC) Main (NO) (NC) 12 25 38 65 125 180 300 YS1N-9F YS1N-12F YS1N-20F YS1N-25F YS1N-32F YS1N-38F YS1N-40F YS1N-F YS1N-65F YS1N-80F YS1N-100F YS1N-125F YS1N-1F YS1N-180F YS1N-220F YS1N-300F 11 to 17 11 to 17 8 to 12 5 to 13 5 to 13 7 to 14 10 to 15 10 to 15 7 to 12 5 to 13 6 to 14 7 to 15 14 to 22 15 to 22 9 to 16 3 to 13 6 to 13 9 to 17 13 to 20 13 to 20 9 to 13 2 to 12 7 to 13 9 to 17 15 to 23 15 to 23 8 to 16 6 to 15 7 to 15 12 to 23 16 to 24 16 to 24 9 to 16 5 to 14 7 to 15 11 to 21 14 to 22 16 to 24 10 to 16 6 to 17 5 to 17 11 to 23 15 to 22 15 to 22 9 to 16 7 to 16 7 to 16 11 to 20 10 to 27 10 to 26 6 to 19 6 to 20 6 to 20 10 to 26 13 to 31 12 to 30 8 to 22 6 to 18 6 to 18 10 to 24 17 to 34 16 to 31 13 to 31 8 to 25 8 to 28 12 to 29 21 to 39 20 to 36 13 to 29 5 to 22 7 to 22 11 to 29 17 to 36 16 to 36 13 to 33 8 to 27 8 to 30 12 to 31 22 to 41 21 to 38 13 to 31 5 to 24 7 to 24 11 to 31 Notes: 1. The operating time depends on the type of contactor electromagnet and its control mode. 2. The closing time is measured from the time the coil power supply is switched on to the time the main contacts first make contact. 3. The opening time is measured from the time the coil power supply is switched off to the time the main contacts separate. 4. The duration of the arcing time depends on the type of circuit switched by the poles. 5. For normal three-phase applications the duration of the arcing time is normally less than 10 ms. 6. The load is isolated from the coil power supply after a time equal to: the sum of the opening time and the arcing time. -18 www.idec.com USA: (800) 262-IEC or (408) 747-05, Canada: (888) 317-IEC Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (6) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Specifications Electrical Life Curves Electrical Life Curves Fig.1 Utilization Category AC3 Millions of Operating Cycles 10 YS1N-9F YS1N-12F YS1N-20F YS1N-38F,-40F YS1N-F YS1N-65F YS1N-80F YS1N-100F YS1N-125F YS1N-1F YS1N-180F YS1N-220F YS1N-300F AC3 Ue < 440V 5 4 3 2 1 0.5 0.4 0.3 YS1N-25F 0.2 1 2 3 4 5 10 20 30 40 100 1 200 300 400 0 1000 9 12 18 25 65 105 125 180 209 Breaking current Ic (A) 2 0.55 0.75 1.5 2.2 4 5.5 7.5 11 15 18.5 22 30 37 45 55 65 90 140 220 280 220V 0.55 0.75 1.5 2.2 4 5.5 7.5 11 15 18.5 22 30 37 55 75 110 1 200 2 4 380V 0.55 0.75 1.5 2.2 4 5.5 7.5 11 15 18.522 30 37 55 75 90 200 280 425 440V Power rating in kw - Hz category AC3 YS1N-32F Control of three-phase squirrel cage motors switching off during running The breaking current in AC3, Ic, is equal to Ie. (le= rated operational current of the motor) Fig. 2 Utilization Category AC4 Millions of Operating Cycles 1 YS1N-9F YS1N-12F YS1N-20F YS1N-38F,-40F YS1N-F YS1N-65F YS1N-80F YS1N-100F YS1N-125F YS1N-1F YS1N-180F YS1N-220F YS1N-300F AC4 380V < Ue 440V 0.5 0.4 0.3 0.2 0.1 0.05 0.04 0.03 0.02 0.01 Breaking current Ic (A) 10 20 30 40 YS1N-25F YS1N-32F 100 200 300 400 0 1000 2000 3000 4000 00 51 69 102 180 234 3 510 702 8 1454 28 111 272 588 1020 1998 Control of three-phase squirrel cage motors switching off with locked rotor The breaking current in AC4, Ic, is equal to 6 x Ie. (Ie = rated operational current of the motor) -20 www.idec.com USA: (800) 262-IEC or (408) 747-05, Canada: (888) 317-IEC Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (6) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Specifications Fig. 3 Utilization Category AC1 Millions of Operating Cycles 10 YS1N-9F YS1N-12F YS1N-20F YS1N-38F,-40F YS1N-F YS1N-65F YS1N-80F YS1N-100F YS1N-125F YS1N-1F YS1N-180F YS1N-220F YS1N-300F AC1 Ue < 440V 5 4 3 YS1N-25F 2 1 0.5 0.4 0.3 0.2 0.1 1 2 3 4 5 10 20 30 40 100 1 200 240 300 400 0 2 3 Breaking current Ic (A) Switching a resistive circuit (cos ø 0.95) The breaking current in AC1, Ic, is equal to Ie. (le = rated operational current of the load) YS1N-32F Electrical Life in Mixed AC3/AC4 uty Applications By calculation: In a mixed AC3/AC4 application, electrical life can be calculated using the following formula: L = A3 1+ P ( A3-1 ) 100 A4 L: Electrical life in mixed AC3/AC4 application A3: Electrical life for breaking current equal to the rated current of the motor. (AC3 from Fig. 1) A4: Electrical life for a breaking current during starting or plug braking equal to Ic = Kle, where: K 6 Ie = rated motor current (AC4 from fig. 2) P/100: ratio of switching off during starting or plug braking www.idec.com USA: (800) 262-IEC or (408) 747-05, Canada: (888) 317-IEC -21 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (6) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Specifications 1. Operating Specifications Operating and Mounting Specifications for Contactors and Starters Ambient Temperature Temperature inside the control panel Relative humidity 2. Mounting -5 to +40 C -5 to +55 C 45% to 85% RH Altitude No more than 2,000m Vibration resistance Shock resistance Storage temperature 10 to Hz 19.6m/s 2 (2G) 49.0m/s 2 (5G) -40 C to +70 C irect Mounting 1. Install the product in a dry area with minimal dust and vibration. 2. Standard mounting is done on a vertical surface in the directions shown in Figure 1. However, a mounting angle up to 30 degrees is allowed in each direction as shown in Figure 2. Operational characteristics of the product, when mounted with these angles are listed on the next page. 30 30 30 30 Figure 1 Figure 2 IN Rail Mounting YS Series electromagnetic contactors/starters YS1N/YS2N-9F through -38F models can be mounted on 35mm wide IN rail, and YS1N/ YS2N -40F through -65F models can be mounted on 75 mm wide IN rails, as specified in the table below. When mounting the product on IN rails, keep in mind the following points: 1. Spacing between the products: contributes to a temperature rise and affects the product life. Maintain the minimum spacing as specified in the table below 2. IN rail mounting holes: To ensure sufficient mechanical strength, the mounting holes should be placed no further apart than those specified in the table below. Product Category IN rail width (mm) Minimum spacing between contactors (mm) istance between mounting screws (mm) Contactor Starter (G) (L) YS1N-9F YS2N-9F 35 5 300 YS1N-12F YS2N-12F 35 5 300 YS1N-20F YS2N-20F 35 5 300 YS1N-25F YS2N-25F 35 5 300 YS1N-32F YS2N-32F 35 5 300 YS1N-38F YS2N-38F 35 5 300 YS1N-40F YS2N-40F 75 5 300 YS1N-F YS2N-F 75 5 300 YS1N-65F YS2N-65F 75 5 300 Minimum Space Between Contactors (mm) G istance Between Mounting Screws L L L Mounting Screw -22 www.idec.com USA: (800) 262-IEC or (408) 747-05, Canada: (888) 317-IEC Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (6) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Specifications Mounting Angle and Operational Characteristics of the YS1N, YS2N, YS1R, YS2R Contactor /Starter Nonreversing Reversing Maximum turn-on voltage (V) Minimum turn-off voltage (V) Coil Frequency (Hz) YS1N/ YS2N YS1R/ YS2R -9F -9F -12F -12F -20F -20F -25F -25F -32F -32F -38F -38F Standard/ normal mounting 126 126 122 138 122 138 30 left 30 right 30 tilted forward 111 123 111 123 120 136 120 136 133 133 110 121 110 121 121 138 121 138 112 130 112 130 118 129 118 129 124 140 124 140 124 145 124 145 30 tilted backwards 104 120 104 120 115 115 99 99 Standard/ normal mounting 84 102 84 102 105 119 105 119 95 95 30 left 30 right 30 tilted forward 98 98 102 111 102 111 77 93 77 93 80 95 80 95 99 112 99 112 103 118 103 118 81 81 30 tilted backwards 90 90 101 117 101 117 91 91-40F -40F 133 112 130 124 145 99 95 77 93 81 91 -F -F 116 138 117 135 116 131 149 107 128 91 110 88 108 87 106 86 106 84 105-65F -65F 116 138 117 135 116 131 149 107 128 91 110 88 108 87 106 86 106 84 105-80F -80F -100F -100F -125F -125F Coils with the following rated voltage were used to obtain the above values: YS1N-9F to-65f: 200V Hz, 200-200V Hz YS1N-80F to-125f: 200-220V Hz, 200-220V Hz www.idec.com USA: (800) 262-IEC or (408) 747-05, Canada: (888) 317-IEC -23 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (6) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Specifications Specifications for Accessories AC Ratings of Auxiliary Contacts AC Ratings per EN AC Ratings (EN-947-5-1) UL / c-ul AC Ratings (UL 8) Wire Sizes for Auxiliary Contacts YS1N-9F to -300F Rated Insulation Voltage (V) 6 Rated Thermal Current (A) 10 Rated Operational Current AC-15 (A) AC 200-2240V 3 AC 380-480V 1.5 AC 0-0V 1.2 Rated Insulation Voltage (V) 0 Rated Thermal Current (A) 10 Rated Operational Current (NEMA A0) AC 120V 6 AC 240V 3 AC 480V 1.5 AC 0V 1.2 Minimum-Maximum Wire Size YS1N-9F to -300F Stranded Wire (without ferrule) Solid Wire (ferrule) 1 Conductor 2 Conductors 1 Conductor 2 Conductors mm 2 (AWG) mm 2 (AWG) mm 2 (AWG) mm 2 (AWG) 1-4 (18-10) 1-4 (18-10) 1-4 (18-10) 1-4 (18-10) Instructions for Assembling Auxiliary Contact Blocks: For each magnetic contactor/starter, up to four contacts of the auxiliary contact blocks can be mounted. Two contacts of the top-mount style and two contacts of the side mount style can be combined. YS1A-TAH2 YS1A-TAH4 YS1A-TAH2 YS1A-TAS2 YS1A-TAS2 YS1A-TAS2 YS1A-TAH2 YS1A-TAS2 YS1A-TAS2 YS1A-TAH4 YS1A-TAS2 YS1A-TAS2 Terminal Numbers and Mounting Examples of Auxiliary Contact Blocks, Side-Mount Style YS1N-9F to -65F YS1R-9F to -65F B @ A C R S T F E G U V W B @ A C R S T U V W R S F F B @ E E A G G C T U V W Note: If you would like to mount two side-mount auxiliary contact blocks (TAS style) to a YS1N non-reversing contactor, mount YS1A-TAS211F. -28 www.idec.com USA: (800) 262-IEC or (408) 747-05, Canada: (888) 317-IEC Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (6) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Mounting and Removing Auxiliary Contact Block on the Contactor Specifications Top Mount Style 1. Position the contactor and the auxiliary contact block in the same direction. 2. Insert the auxiliary contact block into the area of the top of the contactor. Slide the auxiliary contact until it bottoms (o not force.) Make sure that the locking hook is locked into position as shown Removal Procedure While lightly lifting the locking hook with your finger, slide the auxiliary contact unit out. Side-Mount Style 1. Contactor plunger 2. Inside this area, there are locking hooks (upper and lower areas) IN rail Mounting 1. Make sure that the auxiliary contact block (right or left side) and the terminal numbers on the contactor are in the same direction. 2. Push the plunger of the contactor downwards approximately 2mm. While holding the plunger in this manner, insert the white protruding portion of the auxiliary contact block into the square groove of the side of the contactor. Make sure that the locking hook is locked into position. Removal Procedure Hold the auxiliary contact block and pull it off. www.idec.com USA: (800) 262-IEC or (408) 747-05, Canada: (888) 317-IEC -29 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (6) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

imensions Non-Reversing AC Contactors All imensions in mm. Non-Reversing Contactors YS1N-9F, YS1N-12F YS1N-40F, YS1N-F, YS1N-65F 8 76 9 121.5 89 (YS9Z-TU25) 119.5 (YS9Z-TU65) 12 44 12 (YS1A-TAS) (YS1A-TAS) 110 (YS1A-TAH) 12 75 12 154 (YS1A-TAS) (YS1A-TAS) (YS1A-TAH) YS1N-20F, YS1N-25F YS1N-80F, YS1N-100F, YS1N-125F 8 91 85 97 (YS9Z-TU25) 141 12 45.5 12 (YS1A-TAS) (YS1A-TAS) 124 (YS1A-TAH) 100 30 133 YS1N-32F, YS1N-38F YS1N-1F 158 9 111 92 101.5 (YS9Z-TU65) 180 12 58 12 (YS1A-TAS) (YS1A-TAS) 143.5 (YS1A-TAH) 130 188 www.idec.com USA: (800) 262-IEC or (408) 747-05, Canada: (888) 317-IEC -35 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (6) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

imensions Non-Reversing Contactors YS1N-180F YS1N-220F, YS1N-300F 158 184 180 210 130 188 146 234 Non-Reversing Contactors C Operated Non-Reversing C Contactors YS3N-9FG2, YS3N-12FG2 YS3N-80FG, YS3N-100FG, YS3N-125FG 8 107.5 81.4 141 44 100 30 133 YS3N-20FG2, YS3N-25FG2 YS3N-32FG2, YS3N-38FG2 8 118.5 9 138 86.5 92 45.5 58 YS3N-40FG2, YS3N-FG2, YS3N-65FG2 9 1 75-36 www.idec.com USA: (800) 262-IEC or (408) 747-05, Canada: (888) 317-IEC Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (6) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Mounting/Wiring Non-Reversing AC Contactors Mounting, Screw Mounting, and Rail Mounting Non-Reversing Contactors YS1N, YS1N-12F YS1N-40F, YS1N-F, YS1N-65F 2-4.8 IA. 2-4.8 IA. 48 52 15.5 IN RAIL 35mm 2-4.8 IA. A B 2-4.8 IA. 95 100 6 IN RAIL 75mm 5 34 35 4.5 5 B 65 A 7 YS1N-20F, YS1N-25F YS1N-80F, YS1N-100F, YS1N-125F 2-4.8 IA. 70 75 5 IN RAIL 35mm 4-6 IA. MTG HOLES(M5) 110 19 5.2 35 4.5 7 80 86 YS1N-32F, YS1N-38F YS1N-1F 2-4.8 IA. 2-4.8 IA. IN RAIL 35mm 15 70 75 10.5 125 130 25 100 4-M6 MTG HOLES 4 4.5 www.idec.com USA: (800) 262-IEC or (408) 747-05, Canada: (888) 317-IEC -43 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (6) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Mounting/Wiring Mounting, Screw Mounting, and Rail Mounting, continued Non-Reversing Contactors YS1N-180F YS1N-220F, YS1N-300F 15 100 4-M6 MTG HOLES.5 45 4-M6 MTG HOLES 125 130 25 190 10 Non-Reversing Contactors, C Operated YS3N-9FG2, -12FG2 2-4.8 IA. 2-4.8 IA. 48 52 Non-Reversing C Contactors IN Rail 35mm YS3N-80FG, YS3N-100FG, YS3N-125FG 4-6 IA. MTG HOLES(M5) 110 19 34 35 4.5 7 80 86 YS3N-20FG2, YS3N-25FG2 2-4.8 IA. IN Rail 35mm YS3N-32FG2, YS3N-38FG2 2-4.8 IA. 2-4.8 IA. IN Rail 35mm 70 70 75 4.5 4.5 YS3N-40FG2, YS3N-FG2, YS3N-65FG2 2-4.8 IA. 2-4.8 IA. IN Rail 75mm 95 100 75 35 A B B A 65 7-44 www.idec.com USA: (800) 262-IEC or (408) 747-05, Canada: (888) 317-IEC Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (6) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com