X-MULTI THE NEW CHOICE FOR INTELLIGENT LIFE

Similar documents
BRIVIS DUCTED INVERTER SERVICE MANUAL DRCi

Fault Codes. J control

KMIR. Multi outdoor units. troubleshooting Multi zone CONDENSING UNITS MKMIR218-H221, KMIR327-H217, KMIR436-H217, KMIR545-H219.

QUARTZ INVERTER TROUBLESHOOTING GUIDE

troubleshooting Outdoor Unit: KSIE009-H221-O, KSIE012-H220-O, KSIE018-H220-O KSIE024-H220-O, KSIR036-H218, KSIR048-H218

KSID MINI Split DC Inverter QUICK CONNECT Air Conditioner TROUBLESHOOTING KSID016-H215Q. Model Numbers:

Service Manual. 9. Maintenance. 9.1 Precautions before Maintenance. discharge resistance or plug of soldering iron. Installation and Maintenance

PART7. Trouble Shooting

LG Air Conditioning Universal & Multi Split Fault Codes Sheet. Universal and Multi Split Units

LUV INVERTER SERIES. Self-diagnostics and Trouble-shooting. Part 2 of 2 42/38LUV028H 42/38LUV035H 42/38LUV052H 42/38LUV065H 42/38LUV070H 42/38LUV080H

LIGHT COMMERCIAL. Troublesooting

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU18RLXFW AOU24RLXFW ASU18RLF ASU24RLF R410A

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

9. Maintenance. 9.1 Error Code List. Service Manual. Installation and Maintenance

Application Engineering Europe

SF6 PREKIDAČI za kv SF6 CIRCUIT-BREAKERS for kv. tel: , fax:

Driftsinstruks. Utopia kontroller feilkoder PCP-2HTE og PC-ART. Vi håper de får stor glede av et Novema kulde produkt!

6. Troubleshooting. 6-1 Basic items for trouble shooting. Samsung Electronics 17

Product Specifications

WL250 TOWER DRAWING AND PARTS LIST

Trouble Shooting. Symptom Possible Cause Solution Power switch ON but switch Light is Off. Main power to unit Off. Switch light defective.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

EVA KREVETIĆ SA 2 LADICE 60X120 EVA BABY ROOM 60X120 ROCKİNG CRADLE

CX-SERIES ADVANCED BATTERY CHARGER

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Italy

No Operation of air conditioner Explanation

KONSTANTNOG PROTOKA ZA SERVOUPRAVLJANJE

OUTDOOR UNIT CONTROLLER (OUC)

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Compact Wall Mounted Wall Mounted / Floor Compact Cassette / Slim Duct INVERTER MULTI

Superior Performance in Extreme Temperature Submittal Data: SAP09HP230V1A

Troubleshooting Guide

3. SERVICE TOOLS Inverter checker RSUK09-17 CLIMATE COMFORT. All Seasons. Heating. Air Conditioning. Applied Systems.

SPLIT TYPE ROOM AIR CONDITIONER FLOOR TYPE

Service Facts. WARNING: HAZARdOuS VOLTAGe - disconnect POWeR and discharge 4TTX6048-SF-1K. ComfortLink II System Cooling 4TTX6048C1000A.

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTZ0036B-SF-1B. ComfortLink II System Cooling 4TTZ0036B1000A CAUTION

YN012GMFI16RUD Decription: Model Number: Product Code: Power Supply:

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

LG Air conditioning CAC and Multi Split unit Fault code sheet Universal and Multi Split Units

12. Troubleshooting Items to be checked first. Samsung Electronics

<Slim Duct Type> MMD-AP0071SPH, AP0091SPH, AP0121SPH, AP0151SPH, AP0181SPH

CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS

VRF Indoor Unit 50Hz. Type: Wall Mounted M Series Wall Mounted S Series

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Service Facts. WARNING: HAZARdOuS VOLTAGe - disconnect POWeR and discharge 4TWX6024-SF-1K. ComfortLink II System Heat Pump 4TWX6024C1000A.

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

2. LS-Q096AAG, LS-Q096AAL, LS-Q096ACG LS-Q096ADL, LS-Q096ADG, LS-Q096BAG LS-Q096BAG, LS-Q096BDG, LS-Q096BDL LS-Q082BAM CN-TH TRIAC MOTOR CN-U/D STEP

Digital Room Thermostats with Touch Screen LCD

SERVICE MANUAL Room Air Conditioner DC Inverter Multi Split Outdoor units

35 35A 50 50A 1 Single phase. Solid state power controller

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

Bosch Climate 5000 Ductless Minisplit System

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Application Engineering

WL250 TOWER DRAWING AND PARTS LIST

Application Engineering

Gate & Door Controller with LCD and Intelligent Technology

Catalog JR(H/V)54(B/B+)

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

Technical Data Sheet. Model: AJB2433ZXD (AJB2433Z) Product Description. Product Specifications 3/15/2019. Reciprocating. Performance.

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE

WL250 COUNTER TOP DRAWING AND PARTS LIST

P445 Series Electronic Lube Oil Control

Technical Data Sheet. Model: AJB2444ZXD (AJB2444Z) Product Description. Product Specifications 11/19/2018. Reciprocating. Performance.

R820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017

Technical Data Sheet. Model: AVA2490ZXN. Product Description. Product Specifications 6/7/2018. Reciprocating

4.Failure phenomenon. Mirage comes out from indoor. When the cold air from AC cools the indoor air. unit

Pocket Quick. Reference Guide. On the TOSHIBA. R410A - VRF Range of equipment. Addressing / Commissioning

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

Emergency lighting units EM powerled

PRODUCT CODE MODEL NAME RASC-10HNPE. No. DESCRIPTION DWG No. PART No. Qty Qty Qty Qty Qty REMARKS

Trouble Shooting a Jouan C/CR4.22 Centrifuge

YN018GMFI16M2D-V V~ 60Hz 1Phase Serials: PRE

SVE VRHUNSKE KLIME. samo čekaju da vam ih dostavimo i postavimo. maloprodajni cjenik klima uređaja 2017/2018. Powered by OVLAŠTENI PARTNER:

Magnetek DSD 412 Drive

WL350 TOWER LAYOUT DRAWING AND PARTS LIST

CWP. Cooling Only Version (CO) Condenserless Version (RC) Heat Pump Version (HP) Models 02 to 35. Engineering Data Manual. Water Cooled Water Chillers

Waterlogic infiniti PARTS DRAWING AND PARTS LIST. Wetted Parts

Idle Free Systems, Inc. Reference Guide System Component Information

Part 2 Functional Description

9. Maintenance. 9.1 Precautions before Maintenance. Service Manual. electrolytic capacitor after power off. maintenance safely.

c-go 24V/6A 24V/8A 24V/12A

CURTIS TOLEDO. AF Series Compressors VS models with VFD WARNING

AIR-CONDITIONER SERVICE MANUAL. RBM-Y1034F-PE (3-way) 3-PIPE SUPER MULTI, HEAT PUMP WITH SIMULTANEOUS HEATING AND COOLING. RBM-Y1044F-PE (4-way)

Accessories. Series REC

Installation and Operation Manual Back-UPS BX1100CI-CN

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

14 EXPLODED DIAGRAM/PARTS LIST. SMMS-i OUTDOOR UNIT MMY-MAP0804HT8P, MMY-MAP1004HT8P, MMY-MAP1204HT8P

A/C-HEATER SYSTEM - AUTOMATIC

STONESTAR AUSTRALIA PTY LTD

SERVICE MANUAL MIDEA AIRCONDITIONER EUROPE MARKET SUPER DC INVERTER MULTI TYPE

3.5 Air Conditioning (A/C) Contents

RWBa. ROOM CONTROL EQUIPMENT Electronic control of cooling and heating. RWBa

Ru~ne pumpe Hand pumps KLIPNE, VISOKOG PRITISKA, ZA OP[TE I POSEBNE NAMENE PISTON PUMP, HIGH PRESSURE, FOR GENERAL AND SPECIAL PURPOSE

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S

Transcription:

X-MULTI

5. Kratki uvod u instalaciju: Postavljanje X-MULTI --Instala Instalacijska procedura (za detaljnije upute vidi instalacijski priručnik): Odreñivanje mjesta instalacije Educiranje kupca o pravilnom načinu korištenja klima ureñaja. Polaganje instalacija i ožičenje Provjera rada ureñaja u hlañenju i grijanju Instalacija unutarnjih i vanjske jedinice Adresiranje unutarnjih jedinica Spajanje instalacija na pravi način Provjera napona: : 230V±10% Provjera cijele instalacije prije vakuumiranja Refrigerant system and electric system Vakuumiranje i eventualna nadopuna sustava

--Va Važne napomene kod instalacije: Postavljanje X-MULTI 1) za meñuvezu obavezno koristiti oklopljeni kabel; 2) instalater mora vakuumirati sustav kako bi se provjerilo eventualno curenje; 3) prije spajanja napojnih kablova i pokretanja ureñaja aja, potrebno je provjeriti je li napon u granicama 230V±10%; 4) sustav se uvijek dopunjava s R410A u tekućem em stanju; 5) prije pokretanja sustava potrebno se uvjeriti da su unutarnje jedinice pravilno adresirane Refrigerant system and electric system

Postavljanje X-MULTI Adresiranje unutarnjih jedinica Indoor address setting

Postavljanje X-MULTI Dva su načina adresiranja: Indoor address setting

Postavljanje X-MULTI Pomoću daljinskog upravljača (default) A. Korištenje daljinskog upravljača B. Korištenje dip switch-eva na PCB-ima unutarnjih jedinica. 2. Procedura adresiranja korištenjem daljinskog upravljača. A. Adresiranje se obavlja tek po uspješnoj instalaciji i ožičenju, te otvaranju svih ventila B. Uvjerite se da unutarnje i vanjska jedinica istog sustava koriste isti izvor napajanja; C. Postavljanje svih jedinica u standby mode; D. Adrese podesiti kako slijedi: Unutarnja jedinica na ventilu A, mora imati adresu 1; Unutarnja jedinica na ventilu B, mora imati adresu 2; Unutarnja jedinica na ventilu C, mora imati adresu 3; Unutarnja jedinica na ventilu D, mora imati adresu 4; Indoor address setting

E. Primjer: podesite jedinicu A na adresu 1.Pritisnite i držite emergency switch u trajanju oko 15 sekundi, oglasit će se 4 puta (PI PI PI PI) i tada pustite prekidač. Unutarnja jedinica počela je s procedurom adresiranja. F. Koristeći daljinski upravljač uključite un. jedinicu. Status se mijenja iz OFF u ON i TIMER LED jednom zatreptičime se potvrñuje početak procedure adresiranja. G. Pritisnite "SLEEP " na daljinskom upravljaču, broj pritisaka odreñuje adresu koju želite podesiti, i to kako slijedi: Pritisnite " SLEEP " jednom, adresa je "1 ", i TIMER LED zatrepti jednom; Pritisnite " SLEEP " dva puta, adresa je 2 ", i TIMER LED zatrepti dva puta Pritisnite " SLEEP " tri puta, adresa je 3 ", i TIMER LED zatrepti tri puta Pritisnite " SLEEP " četiri puta, adresa je 4 ", i TIMER LED zatreptičetiri puta H. Daljinskim upravljačem ugasite ureñaj. Status se mijenja iz ON u OFF. I izlazi se iz procedure adresiranja, adrese ostaju memorirane. LED board će pokazivati adresu unutarnje jedinice dok se sustav ne ugasi. I. Za promjenu adrese ponovite korake od E do G. J. Nakon adresiranja isključite i ponovno uključite sustav čime se isti aktivira. K. Po uspješnom adresiranju izbjegavajte naknadne promjene kako bi se izbjegli potencijalni problemi. Indoor address setting Postavljanje X-MULTI

Postavljanje X-MULTI Drugi način adresiranja AB TIPOVI: Procedura adresiranja korištenjem DIP switch SW01 and SW03. SW01-7 ON: Adresiranje un. jedinica preko DIP switch-eva; OFF: Adresiranje preko daljinskog upravljača Indoor address setting

Postavljanje X-MULTI Indoor address setting

Postavljanje X-MULTI Indoor address setting

Postavljanje X-MULTI Indoor address setting

Postavljanje X-MULTI Važno: Unutarnje jedinice moraju biti adresirane kao 1,2,3, odozdo prema dolje, u suprotnom sustav neće raditi kako treba. 4. Kako provjeriti adrese? Po završetku postupka adresiranja, isključite i ponovno uključite struju ali ostavite sve unutarnje jedinice u stand-by modusystem but set all the indoor units in STANDBY. Zatim pritisnite emergency switch dok ne čujete zvono 5 puta (Pi Pi Pi Pi), a na TIMER LED displayu tada možete očitati adresu unutarnje jedinice. Pritiskom na bilo koju tipku daljinskog upravljača, izlazite iz procedure provjere adresa unutarnjih jedinica. Indoor address setting

2. Dijagram rashladnog kruga: Postavljanje X-MULTI --di dijagram (AU182XFERA / AU222XFERA): TOCI B A Refrigerant system and electric system

Postavljanje X-MULTI --di dijagram (AU282XHERA / AU362XHERA): TOCI B A Refrigerant system and electric system

Postavljanje X-MULTI 3. Strujna shema i objašnjenje pojedinih električnih dijelova: --Strujna shema vanjske jedinice (AU182XFERA / AU222XFERA): TOCI TC TS TA TD TE CAPACITOR-1 CN1 CN23 TO SPDU CN22 CN21 CN2 N CN3 CONTROL CIRCUIT BOARD AC FAN MOTOR M L M H Y/G CRANKCASE HEATER CN4 SV2 4WV CN6 CN7 CN5 FUSE1 250VAC T3.15A start/up stop/down SW1 SW2 SW3 SW4 ON 4-WAY VALVE LED2 LED1 1234 5678 SW5 CN8 N CN9 L CN10 BUS CN11 PTC CN12 LED CN26 LED1 LED2 DIAGNOSE PCB LED3 ON LED4 1 2 3 4 SW5 LED5 REACTOR CAPACITOR-2 - + BL OR RO P(+) ACN N(-) SPDU RI ACL U U R V W W B V W CN20CN19 HP LP CN18 PMV_A CN17 PMV_B CN16 PMV_C CN15 PMV_D CN14 DEBUG_LED CN13 COMPRESSOR M M M R R CN7 RL1 CN8 CN2 FUSE T25A 250VAC 220VAC-L CN1 CN5 CN4 CN3 220VAC-N POWER CIRCUIT BOARD TOCI PIPING TEMPERATURE SENSOR TC CONDENSING TEMPERATURE SENSOR TS: COMPRESSOR INHALE SENSOR TA AMBIENT TEMPERATURE SENSOR TD: COMPRESSOR VENT SENSOR TE DEFROSTING TEMPERATURE SENSOR OR : ORANGE B : BLACK BL : BLUE Y/G : YELLOW/GREEN R : RED W : WHITE Refrigerant system and electric system W B Y/G B W N L C1C2 L N Y/G To Indoor Units To Power Supply

W4 ON 1 2 3 4 567 8 SW5 Postavljanje X-MULTI Dip 1: odabir motora ventilatora Dip 2: odabir vrijednosti defrosta Dip 5~6: odabir modela Dip 8: odabir tihog načina rada CN26 LED1 LED2 DIAGNOSE PCB LED3 ON LED4 1 2 3 4 SW5 LED5 Dip 1 ON: prisilno grijanje Dip 2 ON: prisilno hlañenje Dip 3 ON: grijanje Dip 4 ON: hlañenje Normal status (ne radi): sve isključeno Refrigerant system and electric system

4. Uvod u glavne funkcije: --Pokretanje kompresora. Postavljanje X-MULTI Postoje dvije vrste pokretanja kompresora ovisno o stanju sustava To su HOT START i SOFT START.Kako bi se sigurnije pokrenuo kompresor nakon dužeg mirovanja, koristit će e se SOFT START, glavni razlog je izbjegavanje povrata tekućine kod starta. U protivnom koristit će e se HOT START. SOFT START procedura: : max. 6 minuta Refrigerant system and electric system

Postavljanje X-MULTI HOT START procedura: traje oko 3 minute od 0HZ do ciljanog broja HZ. Refrigerant system and electric system

--Frekvencijska kontrola kompresora: Kako sustav odabire radnu frekvenciju: Postavljanje X-MULTI Raspon frekvencija u ovisnosti o TAO Kontrola frekvencije kod pokretanja ureñaja Zahtjevi unutarnjih jedinica odreñuju početnu vrijednost frekvencije Tao<33 hlañenje Tao>5 grijanje Ciljana temperatura isparavanja ili kondenzacije Maksimalna snaga Granične frekvencije Kod promjene temperaturne razlike na un. jedinicama Sljedeći podaci koriste se za odabir radne frekvencije: --hlañenje: Tao, Tc2AVE, T=Tai-Toutlet Tao odreñuje frekvencijski raspon u kojem kompresor može raditi; Ako je TinAVE > ciljana vrijednost A, kompresor povećava frekvenciju; Ako je TinAVE < ciljana vrijednost A, kompresor smanjuje frekvenciju; T odreñuje početnu vrijednost frekvencije --grijanje: Tao, TmAVE, T=Toutlet-Tai Tao odreñuje frekvencijski raspon u kojem kompresor može raditi; Ako jetmave > ciljana vrijednost B, kompresor povećava frekvenciju; Ako jetmave < ciljana vrijednost B, kompresor smanjuje frekvenciju; T odreñuje početnu frekvenciju; Refrigerant system and electric system

Postavljanje X-MULTI --kontrola brzine rada ventilatora vanjske jedinice: Kako sustav odreñuje brzinu rada ventilatora vanjske jedinice : Kontrola rada ventilatora kod pokretanja ureñaja Brzinu ventilatora odreñuje Tao(vanjska temperatura) Brzinu ventilatora odreñuje vanjska jedinica hlañenje grijanje Brzinu rada ventilatora odreñuje TC Brzinu ventilatora odreñuje temp. razlika SH SH=Toci - Te HLAðENJE GRIJANJE Refrigerant system and electric system

--Kontrola defrosta vanjske jedinice: 1Ulazni uvjeti (sljedeća tri uvjeta moraju biti zadovoljena): -start up kompresora najmanje 10 minuta; -ukupno vrijeme rada kompresora je najmanje 45 minuta; -senzor Te vrijednost < ciljana vrijednost C (C=a-x, x=8 or 10, ovisno o postavkama) 2Defrost procedura: vidi sljedeću stranu --Kontrola grijača a kućišta ta: u svrhu zaštite kompresora 1Kada jetao A i kompresor ne radi, grijač je uključen (ON). 2) Kada je Tao A+5, ili kompresor radi, grijač je isključen (OFF). * A=27 Postavljanje X-MULTI Refrigerant system and electric system

Postavljanje X-MULTI Defrost procedura Refrigerant system and electric system

--PMV PMV s kontrole: Postavljanje X-MULTI 1U hlañenju, PMV-i rade prema stvarnom SH(=Tc1 Tc2) i ciljanoj SH vrijednosti. 2) U grijanju, PMV-i rade prema stvarnom SC(=Tm Tc2) i ciljanoj SC vrijednosti. Tc2 Isparivač - unutarnja jedinica Tc1 Tm Tai 3Kada je SH < ciljane vrijednosti SH, ventil se zatvara; Kada je SH > ciljane vrijednosti SH, ventil se otvara; 2) Kada je SC < ciljane vrijednosti SC, ventil se otvara; Kada je SC > ciljane vrijednosti SC, ventil se zatvara; SH Protok SC Refrigerant system and electric system 0 250 500 Pulse

5. Kratki uvod u instalaciju: Postavljanje X-MULTI --Instala Instalacijska procedura (za detaljnije upute vidi instalacijski priručnik): Odreñivanje mjesta instalacije Educiranje kupca o pravilnom načinu korištenja klima ureñaja. Polaganje instalacija i ožičenje Provjera rada ureñaja u hlañenju i grijanju Instalacija unutarnjih i vanjske jedinice Adresiranje unutarnjih jedinica Spajanje instalacija na pravi način Provjera napona: : 230V±10% Provjera cijele instalacije prije vakuumiranja Refrigerant system and electric system Vakuumiranje i eventualna nadopuna sustava

--Va Važne napomene kod instalacije: Postavljanje X-MULTI 1) za meñuvezu obavezno koristiti oklopljeni kabel; 2) instalater mora vakuumirati sustav kako bi se provjerilo eventualno curenje; 3) prije spajanja napojnih kablova i pokretanja ureñaja aja, potrebno je provjeriti je li napon u granicama 230V±10%; 4) sustav se uvijek dopunjava s R410A u tekućem em stanju; 5) prije pokretanja sustava potrebno se uvjeriti da su unutarnje jedinice pravilno adresirane Refrigerant system and electric system

Održavanje X-MULTI Moguće e pogreške i njihovo otklanjanje Trouble shooting

Održavanje X-MULTI --Problem Problemi i s temperaturnim senzorima zorima: : Te, Tao, Ts, Td, Tc, Toci,, Tc1, Tc2, Tm, Tai KAKO RIJEŠITI ITI PROBLEM SA SENZORIMA? Check the sensors according to the wiring diagram to see whether the sensor is properly inserted into the PCB no Re-insert it and check again yes Check the sensor whether it is broken or bad connection with the PCB no Check the resistance value to see whether it is normal no Bad sensor, change it and check again yes yes Change the sensor and check again Bad PCB, change it and check again Trouble shooting

Održavanje X-MULTI fault1.lcd has no display START check the LCD whether or not fit to the unit NO change the LCD then check again YES whether the LED red and LED green on the PCB of indoor unit is alternation flashing NO check whether the power terminal block has 220V input NO check the terminal block and power supply facility the PCB broken,change it NO check whether the LCD has 12V power supply check whether the power wire open circuit check whether the fuse burn the PCB broken,change it YES the LCD circuit broken,change it change the power wire then check again change the fuse then check again Trouble shooting

Održavanje X-MULTI fault2.the LCD display sensor fault start Brojčana oznaka pogreške refer to the circuit diagram,check whether the sensor instert right on the PCB no insert the sensor again 1 2 3 yes check whether the sensor open circuit or the PCB has broken faucet yes change the sensor,check again no check whether the sensor value correct yes the PCB broken,change it then check again no change sensor,check again 4 Trouble shooting

Održavanje X-MULTI fault3.the LCD display faulty of indoor unit start Kodovi kvara prikazani na ekranu unutarnje jedinice refer to the circuit diagram,check whether the communication terminal block wire is correct whether the communication wire between indoor and outdoor unit is open circuit reconnection the wire,check again whether the power wire and the communication wire too close up lead to communication data incorrect THE pcb broken,change it then check again 6 change the communication wire,check again make the wires proper space,check again Otklanjanje gresaka

Održavanje X-MULTI fault 4.indoor unit EEPROM data incorrect fault Kodovi kvara prikazani na ekranu unutarnje jedinice 1.the first time power on display this fault check the EEPROM pin or the eeprom broken 2. when the unit is running displsy this fault.the eeprom broken,change it 5 Trouble shooting

Održavanje X-MULTI fault5.indoor unit address repeated Kodovi kvara prikazani na ekranu unutarnje jedinice 1.do the address lookup firstly: Ł şturn off the indoorunit Ł press the buzzer continuous about 15 secł after the buzzer 5 times ring then loose.the LCD display the num is the address of this indoor unit,the address can be check by this way,if there is address repeated then follow this way to change the indoor unit address. 9 correspond to the address 1,the outdoor unit pipe B correspond to the address 2,the outdoor unit pipe C correspond to the address 3, Trouble shooting

Održavanje X-MULTI fault6.fan fault.ac has no 50HZ exceed zero verify Kodovi kvara prikazani na ekranu unutarnje jedinice start check thether the fan input block instert correct or open circuit ( PCB CN3) yes no CHECK whether the fan feedback wire instert correct or open circuit ( PCB CN23) yes no PCB broken,change it change the fan inpout block,turnoff the power,then turn on again and check change the fan feedback wire,turnoff the power,then turn on again an d check 11 Trouble shooting

Održavanje X-MULTI fault7.outdoor unit fault check the outdoor unit PCB (5 leds) display faulty code (binary system) Trouble shooting

Održavanje X-MULTI fault8.outdoor unit display sensor fault start Led 5.4.3.2.1 refer to the circuit diagram,check whether the sensor instert right on the PCB no insert the sensor again,check again yes check whether the sensor open circuit or the PCB has broken faucet check whether the sensor value correct change sensor,check again change the sensor,check again the PCB broken,change it then check again Trouble shooting

Održavanje X-MULTI fault 9.AC current exceed protect or current sensor broken.compressor jam rotate.compressor shake higher.compressor start abnormal.position check loop broken.compressor broken Led 5.4.3.2.1 the fanlt can be auto resume the first and twice.if the outdoor unit PCB display this fault all the time and can't clear,indicate that : 1.the SPDU broken,change it then refer to the circuit diagram connect the wire.(70ł ĄŁ 2.the POWER CIRCUIT BOARD short circuit make the SPDU broken. 3.comprosser broken make the SPDU display this fault Ł 10Ł ĄŁ 4.control circuit board data incorrect,change itł 5Ł ĄŁ Trouble shooting

Održavanje X-MULTI fault10.hp switch fault Led 5.4.3.2.1 reason 1.system pressure higher,unit stop to protection,so the fault can resume 2.the pressure switch wire insert incorrect or open circuit Trouble shooting

Održavanje X-MULTI start check whether the pressure switch wire and the faucet on the PCB is broken or open circuit (PCB CN20) no CHECK whether the two pin of the pressure is broken no whether the outdoor unit fan start normal when cooling no Ł change the control circuit board), check again yes yes change the pressure swicth wire,power off then power on and check again change the pressure swicth wire,power off then power on and check again check whether the outdoor unit fan has power input no change the outdoor fan motor,check again Trouble shooting

Održavanje X-MULTI fault 11.lp switch fault Led 5.4.3.2.1 reason 1.system pressure lower,unit stop to protection,so the fault can resume 2.the pressure switch wire insert incorrect or open circuit Trouble shooting

Održavanje X-MULTI start check whether the pressure switch wire and the faucet on the PCB is broken or open circuit (PCB CN19) no CHECK whether the two pin of the pressure is broken no whether the outdoor unit fan start normal when cooling no Ł change the control circuit board), check again yes yes yes change the pressure swicth wire,power off then power on and check again change the pressure swicth wire,power off then power on and check again check whether the outdoor unit fan has power input no change the outdoor fan motor,check again Trouble shooting