Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet.

Similar documents
Operating Instructions (Translation)

Segurança. Segurança. PSB Heating System Heat shrink technology. Compulsório. Compulsório. Operation Manual/Installation Instructions

Segurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions

Segurança. Segurança. MSB/HSB Heating System. Compulsório. Compulsório. Operation Manual/Installation Instructions. Cold applied connection technology

TIDALFLUX 2300 F Quick Start

Installation manual portable distributors

Installation manual wall-mounted distributor

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

Data sheet chainflex CF8821

Ex m Solenoid Operator Type 0519

Guide for installers. METTLER TOLEDO MultiRange Explosionsproof weighing system with the ID3sTx weighing terminal.

Operating and Installation Manual Shut-off damper Type AK-Ex with control components T0* and P50

EMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions

IS1 I/O-Modules. BusRail Series General Information. Symbols. Conformity to Standards. Safety instructions. Function/Characteristics

Data sheet chainflex CF140.UL

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Data sheet chainflex CF10

Data sheet chainflex CF210.UL

Data sheet chainflex CF6

Explosion protected terminal boxes type, GHG 72.

Data sheet chainflex CF240

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

ET-PWR-END-KIT Installation Instructions (part #JSR00)

Operating Instructions

Data sheet chainflex CF886

Operating Instructions Installation Information. METTLER TOLEDO MultiRange Weighing Platforms PFA574 / PFA575(x) / PFA579(x)

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

Operating Instructions CYR52

INSTALLATION INSTRUCTIONS: Viewline 52 mm

Technical Documentation

INSTALLATION INSTRUCTIONS: Viewline 52 mm

INSTALLATION INSTRUCTIONS: Viewline 85 mm

Data sheet chainflex CF270.UL.D

Installation and Operating Instructions Electric Vibrators HV/VFL Series

Accessories for bus connection DeviceNet, CANopen and Modbus-RTU

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Swing Piston Compressors and Vacuum Pumps

General characteristics and technical data Series MCS

Operating Instructions Flexdip CYA112

INSTALLATION INSTRUCTIONS: Viewline 110 mm

Data sheet chainflex CF886

Instruction Manual. for Heating Cables and Cold Leads Type and Catalogue no and Hemstedt GmbH.

HVS S 15kV Class

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

INSTALLATION OPERATION AND MAINTENANCE MANUAL SMITSVONK HIGH ENERGY IGNITION UNIT TYPE: E-LIGHT

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

Type MZ15. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Wilo-Control SC-Fire Jockey

INSTALLATION INSTRUCTIONS: Viewline 85 mm

PSS 5000 Standard & Compact (For systems with CPB50x)

Operating Instructions

Tina 4A Connection block

Operating Instructions

Operating Instructions Mechanical Temperature Switches ML1H,MT1H,L2H,T2H,L1X/L1X-EX,T1X/T1X-EX,T2X/T2X-EX

Data sheet chainflex CF881

Type 6213 EV, 6281 EV

Linear Luminaire for Fluorescent Lamps

Solenoid Operator 0516 / 1216

SJOF-BS604A Fiber Optic Splice Closure User Manual Rev.0

Data sheet chainflex CF130.UL

CONNECTORS - SINGLE POLE

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Operating instructions

FLENDER ZAPEX couplings. Type ZWT. Operating instructions BA 3505 EN 10/2011. FLENDER couplings

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc.

E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices.

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables

Installation and Operating Instructions Magnetic Vibrator MR 1

INSTALLATION INSTRUCTIONS: Viewline 85 mm

Position Cat6 Shielded. Modular Plug Connectors. Application Specification

System Monitoring SCHOOLMETERBOX AU

Data sheet chainflex CF9

Operating Instructions

Linear Luminaire with LED

FBP PROFIBUS DP Accessories

Operating Instructions Installation Information. METTLER TOLEDO MultiRange Weighing Platforms PUA574 / PUA579(x)

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

13.1. Range of Enclosures. KRONECTION Box A 2 for up to 2 pairs. Expert Knowledge. Short survey of the KRONECTION Box A 2 for up to 2 pairs

AIR FILTER MODEL NO: AF1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO:

zelsius Installation and operating manual All that counts EnergyMetering

Type Operating Instructions. Bedienungsanleitung Manuel utilisateur

FOSC-100 B/H FOSC-100 B2/H

Switching DC Power Supply

Power Connection Kit installation instructions

Operating instructions Spray nozzle SDU

DEVI EasyConnect Heating Cable Connection System

Tubing & Hose Metric. Nylon, Polyurethane, Polyester Reinforced PVC, Metal Braided Rubber, Copper, Double Wall Brazed Steel

Data sheet chainflex CF5

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks

Data sheet chainflex CFSOFT1

Instruction Manual EDS-75-S EDS-100-S/F EDS-160-S/F EDS-200-S/F EDS-220-Z EDS-250-S/F

FL 10 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS. Before operating the pump, please read the Installation Instructions and safety precautions.

Catalyser Introduction. 3. Hazard Information. 2. Area of Application. 3.1 Symbology

Operating instructions. METTLER TOLEDO MultiRange Floor scales/pit scales

User Manual. Solar Charge Controller 3KW

Cold Shrink - Silicone Rubber QTII(X)4S-32H Series Cable Termination Instructions

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Transcription:

Description Marking The ANTARES ExtSet makes it possible to distribute the Remote I/O ANTARES modules of an explosion-protected Remote I/O system ANTARES among a maximum of 4 metal mounting rails. For this purpose, a 2 m / 0 m / 20 m ANTARES ExtSet is used for each mounting rail transition whereby each ExtSet consists of: two extension modules one rail end module and one rail beginning module for each two separately certified rail-mounted earth conductor terminals an, and for each (2 m / 0 m / 20 m in each case), incl. shortening set for adaptation to the requirement a strain-relief set (6 end clamps, 2 cable ties) These modules and conductors and their associated components must be installed between the last Remote I/O module ANTARES of one mounting rail and the first Remote I/O module ANTARES of the other. The following are positioned and connected together in a fixed installation on the mounting rails: Remote I/O Module ANTARES, extension module and rail end module (on one mounting rail) and rail beginning module, extension module and Remote I/O Module ANTARES (on the other mounting rail), to form an enclosure unit conforming to protection class IP30. Danger, warning and note symbols Caution! Attention! Technical data ANTARES ExtSet Non-observance leads to death or serious physical injury. The necessary safety precautions must be taken. Warning of damage to property and financial and penal disadvantages (e.g. loss of guarantee rights, liability claims etc.). Important instructions and information on preventing disadvantageous behaviour. Important instructions and information on effective, economic and environmentally compatible handling. More approvals and data are available at Storage and transport temperature -25 C to +70 C End clamp Protection class (EN 60529, IEC 60529) IP30 (plug connector IP20) Metal TH35-5 mounting rail, DIN EN 6075 Operating position Base latch below (see figure 7) Dimensions (W x H x D) 22.5 x 0 x 4.5 mm Electrical connection Enclosure bottom section 0+2-pole connectors Enclosure top section Spring clamp Degree of contamination 2 Ambient temperature range -20 C to +60 C Relative air humidity 5 to 95 % non-condensing Figures and 2: Components in an ANTARES ExtSet approximately 00 mm (total width of 3 x end clamps, x earthing terminal, x rail beginning module and x extension module) The 2 m / 0 m / 20 m ANTARES ExtSet can be used only in conjunction with the Remote I/O systems ANTARES. Maximum quantity of mounting rail transitions and maximum length of the and the Ext power cables. The total length of the Ext. bus cable and of the Ext. power cables must not exceed a maximum of 20 m! Do not use more than 3 mounting rail transitions! When using more than one mounting rail transition, add the individual lead lengths together. Figures 3: Dimensions /5

/ Product labelling Protection class (EN 60529, IEC 60529) Operating position Dimensions (W x H x D) Electrical connection IP30 (plug connector IP20) Metal TH35-5 mounting rail, DIN EN 6075 Connector on the right Connector on the left 25 x 79 x 57 mm 0-pole connector Ambient temperature range -20 C to +60 C Relative air humidity 5 to 95 % non-condensing Figure 5: Figure 6: Rail module Figures 4: Dimensions and rail end module Earthing terminal with separate certification Rated connection capacity 4 mm² Metal TH35-5 mounting rail, DIN EN 6075 Cable type ÖLFLEX Classic 00 8 x.5 mm²; pre-assembled Minimum bending radius Operating temperature range 2 m / 0 m / 20 m 68 mm - 30 C to +80 C (fixed installation) Cable type ÖLFLEX Classic 00 4 x.5 mm²; pre-assembled 2 m / 0 m / 20 m Minimum bending radius 68 mm Operating temperature range - 30 C to +80 C (fixed installation) Cable type Minimum bending radius Operating temperature range UNITRONIC BUS CAN 2 x 2 x 0.34 mm²; pre-assembled 2 m / 0 m / 20 m 68 mm - 30 C to +80 C (fixed installation) Installation Warnings Do not open the extension module! Do not connect or disconnect any live conductors in a potentially explosive atmosphere! When working on electrical systems, the relevant installation and operating regulations must be complied with, such as e.g. Directive 999/92/EC, Directive 94/9/EC, German Industrial Health and Safety Ordinance (BetrSichV), EN 60079-4, the DIN VDE 000 series or other applicable national standards and ordinances. The operator of an electrical system in a hazardous environment must keep the system in good condition, operate and monitor it properly and do maintenance and repairs. It must be ensured that the IP30 protection class is satisfied by the enclosure unit for the Remote I/O Module ANTARES, extension module and rail end module or rail beginning module! Modules and conductors in the ANTARES ExtSet must not be integrated into a Remote I/O System ANTARES or removed from it if it is connected to voltage and if the atmosphere could be explosive! The Ext power cables and the must be laid as fixed wiring, protected against light and installed together in a bundle! 2/5

An equipotential bonding conductor must be connected to Caution! each mounting rail! Follow steps -3 for each further mounting rail transition. Metal base latch Figure 7: Latching the extension module onto a mounting rail. Place the extension module on the mounting rail with a side spacing of approximately 0 mm from the neighbouring module as shown in Fig. 7 (position the top retaining groove and latch onto the mounting rail with the aid of the metal base latch). Then align side-by-side and almost seamlessly in a row with the neighbouring Remote I/O module(s). 2. Check that it is positioned securely on the mounting rail. 3. Put on the rail end module, align in a row and fasten by tightening the screw. 4. Set up the earth conductor terminal on the mounting rail after the rail end module (to support the Ext. bus cable shielding). 5. After the earth conductor terminal put 3 end clamps from the strain-relief sets, each at a spacing of at least 5 mm, onto the mounting rail and screw in place securely. Run a cable tie for each through the two boreholes on the end clamps (6 cable ties in total), see figure and 2. 6. On the second mounting rail begin with the three remaining end clamps and 6 other cable ties in the strain-relief sets. 7. Mount the earth conductor terminal at a spacing of at least 5 mm from the end clamps and screw tightly. 8. Position the rail beginning module flush with the earth conductor terminal. 9. Clip the extension module on, align in a row at the rail beginning module and screw the rail beginning module securely in place. 0. Fasten the Ext. power cable, Ext. power cable 2 and Ext. bus cable to the end clamps with the aid of the cable ties. In doing so, pay attention to the correct order of the cables (see figures and 2)! Tighten the cable ties with Weidmüller pliers RT in catch position 2 or with a comparable pliers tool and setting. Shortening the cables It is possible to shorten the cables to the required length with the aid of the shortening set (art. no. 05-009-064). The following components are contained in the shortening set: Part designation Pieces Wire-end ferrule DIN 46228 E0.34-8 6 Wire-end ferrule DIN 46228 E.5-8 5 Heat shrinkable tubing 2/4, 40 mm, black, internally adhesive, shrinking 5 temperature 0 C Shrinkable tubing 3.2/.6; 60 mm, 2 yellow, shrinking temperature. 90 C Single wire.5 mm²; GNYE; 00 mm The cable has a banderole (cable marking) at one end. It is important that only the side without banding may be shortened. The following steps must be followed:. Shorten the cable (item ) on the side without banderole to the required length. 2. Strip 70 mm of cable sheath off the shortened end, cut off the core fillers. 3. Push the heat shrinkable tubing (item 4) over the green-yellow (GNYE) wire as far as it will go (end of cable sheath) and shrink. The shrinking temperature for the shrink-fit hose (item 4) is 90 C. Do not overheat the cable! To prevent overheating, proceed as follows: - Heat gun type Bosch GHG 660 LCD - Set to 250 C - A distance of at least 2-5 cm must be maintained between the heat gun and the component! - Blow hot air onto the heat shrinkable tubing all around until it has shrunk completely with the cable. - End the shrinking process. Do not blow any more hot air onto the cable! 4. Position the heat shrinkable tubing (item 3) as illustrated and shrink. The shrinking temperature for the heat-shrinkable sleeve (item 3) is 0 C. Do not overheat the cable (see 3.)! 5. Strip 0-mm insulation off the wires 8x, crimp the wire-end sleeves (item 2) 8x. Figure 8: Weidmüller RT pliers. Connect the cables in conformance to the terminal assignment (figure 9). 2. Connect both ends of the shielding on the Ext. bus cable (single wire GNYE) to the earth conductor terminal. 3. Connect the equipotential bonding conductor to the additional mounting rail. The second connection on the earth conductor terminal can be used for that purpose. ÖLFLEX Classic 00 conductor; 8 x.5 mm 2 2 Wire-end ferrule DIN 46228 E.5-8 8 3 Heat shrinkable tubing 2/4, 40 mm, black, internally adhesive, shrinking temperature. 0 C 4 Heat shrinkable tubing 3.2/.6; 60 mm, yellow, shrinking temperature. 90 C 3/5

Ext Power cable 2. Shorten the cable (item ) on the side without banderole to the required length 2. Strip 60 mm of sheath off the shortened end. 3. Position the heat shrinkable tubing (item 3) as illustrated and shrink. The shrinking temperature for the heat-shrinkable sleeve (item 3) is 0 C. Do not overheat the cable (see Ext. power cable, 3.)! 4. Strip 0 mm of insulation off the cores 4x, crimp wire-end ferrules (item 2) 4x. Wiring Attention! Only the, the and the may be used to connect the extension modules! The cores in the and the Ext power cables must be connected to the terminal points in the two extension modules in accordance with the terminal assignment (see figure 9). Before commissioning, check that the terminal points are secure and that the wiring is correct. X4 X3 Cable ÖLFLEX Classic 00; 4 x.5 mm 2 2 Wire-end ferrule DIN 46228 E.5-8 4 3 Heat shrinkable tubing 2/4, 40 mm, black, internally adhesive, shrinking temperature. 0 C X2 X Ext Bus cable. Shorten cable (item ) on the side without banderole to the required length. 2. Strip 50 mm of sheath off the shortened end, cut off the foil and filler. 3. Bundle the braided sheaths and shorten to 0 mm (from the sheath end). Strip 0 mm of insulation off both ends of the GNYE single wire (item 4). Crimp one end of wire-end ferrule (item 5). Solder the other end with a braided shield bundle. Care must be taken to prevent any soldering tin getting into the lead => risk of an open circuit! 4. Position the heat shrinkable tubing (item 3) as illustrated and shrink. The shrinking temperature for the heat-shrinkable sleeve (item 3) amounts to 0 C. The cable must not be overheated (see, 3.)! 5. Strip wires (4x) 0 mm, crimp wire-end ferrules (item 2) 4x. Terminal X4 X3 X2 X Terminal point Colour of the wire 3 red 4 grey 5 purple 6 yellow 9 black 0 white brown 2 blue 5 blue 6 brown 7 grey 8 black green 2 yellow 3 white 4 brown Figure 9: Terminal assignment Leave the twisted pairs of cores in the bus cable twisted up to just before the terminal. Item 4 soldered with braided sheath of item. Item 3 is then heat-shrunk over it. UNTRONIC BUS CAN cable 2x2x0.34 mm 2 2 Single wire.5 mm², GNYE 5 Wire-end ferrule DIN 46228 E.5-8 3 Wire-end ferrule DIN 46228 E0.34-8 4 Heat shrinkable tubing 2/4, 40 mm, black, internally adhesive, shrinking temperature. 0 C Maintenance If operated correctly in accordance with the installation instructions and environmental conditions, there is no need for regular servicing. Repairs Pursuant to EN 60079-7 only personnel with the relevant qualifications and extensive knowledge in handling explosion-protected equipment may do any of the installation, commissioning, maintenance, repair and conversion work. Only original spare parts may be used. Please consult BARTEC GmbH if you have any questions. 4/5

Waste Disposal Service address The device contains metal, plastic parts and electronic components. Order No. The statutory requirements for the disposal of electronic scrap (e.g. disposal by an approved disposal company must be observed. BARTEC GmbH Max-Eyth-Straße 6 Phone +49 793 597-0 Fax +49 793 597-9 E-mail: Internet: ANTARES ExtSet 2 m (with 2 m cable) Art. no. 05-0090-005 ANTARES ExtSet 0 m (with 0 m cable) Art. no. 05-0090-004 ANTARES ExtSet 20 m (with 20 m cable) Art. no. 05-0090-006 Spare parts: Art. no. 05-0078-023 2 m Art. no. 05-006-0460 0 m Art. no. 05-006-046 20 m Art. no. 05-006-0462 2 m Art. no. 05-006-0463 0 m Art. no. 05-006-0464 20 m Art. no. 05-006-0465 2 m Art. no. 05-006-0466 0 m Art. no. 05-006-0467 20 m Art. no. 05-006-0468 Art. no. 05-004-039 Art. no. 05-004-0320 Shortening set Art. no. 05-009-064 Strain relief set Art. no. 05-0005-0067 Art. no. 03-72-007 5/5