Installation & Instruction Manual

Similar documents
Installation & Instruction Manual

Installation & Instruction Manual

Installation & Instruction Manual

Installation & Instruction Manual

Installation & Instruction Manual

Installation & Instruction Manual

Installation & Instruction Manual

Installation & Instruction Manual

Note: Read this manual carefully before installing the operator and place this installation manual in an accessible place near the operator.

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

Addendum PAN-F / PAN-G / PAN-J

OWNER S MANUAL MODEL NO. MEDIUM DUTY JACK SHAFT OPERATOR MDJ, MDJH, MDJB, MDJBH READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

COOKSON OWNER'S MANUAL

Technical Data Book. Door Operators. Commercial & Industrial. Edition V0

MODEL JH JACKSHAFT INDUSTRIAL DOOR OPERATOR INSTALLATION MANUAL. OPERATOR SPECIALTY COMPANY, INC. P.O. Box 128 Casnovia, MI 49318

EXTREME R MOTOR OWNER'S MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

SAFE AND SECURE EXTREME R MOTOR OWNER'S MANUAL MODEL PRO-FDG FOR TECHNICAL SUPPORT PLEASE CALL 1-(855) OPERATOR SERIAL#

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

Selection Guide. Commercial & Industrial. Door Operators

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION AND OWNER'S MANUAL Model GJ & MGJ Gear Reduced Jackshaft

Model JG Industrial Gearhead Jackshaft Door Operator Safety, Installation, and Service Manual

HAZARDOUS (NEMA 7/9) INDUSTRIAL DUTY COMMERCIAL DOOR OPERATOR 2 YEAR WARRANTY. Serial # Box. Installation Date. Wiring Type

ControlHoist Standard

INSTALLATION M ANUAL

MODEL MG Gearhead Operator

INSTALLATION AND INSTRUCTION MANUAL MODELS: PRO-T, PRO-TB

LMPLC COOKSON OWNER'S MANUAL FDO A & B SOLID STATE INDUSTRIAL DUTY FIRE DOOR OPERATOR. B2/C2 Wiring 2 YEAR WARRANTY FDO 1/2 HP FDO A & B

COOKSON OWNER S MANUAL

OWNER'S MANUAL. C2 Wiring SOLID STATE INDUSTRIAL DUTY DOOR OPERATOR 2 YEAR WARRANTY LOGIC CONTROL NOT FOR RESIDENTIAL USE

ControlHoist Standard

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Linear Actuator Swing Gate Operator Installation Manual Model # LA405-24

APOLLO Gate Operators, Inc.

GLM SERIES CONTROL Users Manual Rev:

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION AND OWNER S MANUAL MODEL T Trolley Operator

MODEL JH-D DC BATTERY BACK-UP JACKSHAFT INDUSTRIAL DOOR OPERATOR INSTALLATION MANUAL

Model 1550 Single Swing Gate Model 1650 Dual Swing Gate

INSTALLATION AND OWNER S MANUAL MODEL T Trolley Door Operator

INDUSTRIAL DUTY COMMERCIAL DOOR OPERATOR

Sliding Gate Operator User's Manual

MJ & MH M-S SERIES JACKSHAFT COMMERCIAL VEHICULAR DOOR OPERATORS with SOLID STATE CONTROLS

HYPPOETL HYPPO DUALETL 12 VOLT DC Swing Gate Operator

SKC400U SLIDING GATE OPENER OWNER S MANUAL

Sliding Gate Operator User's Manual

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Model 2300DL Installation Guide

Gate Operators, Inc. Model 7100UL Residential & Medium Duty Commercial Slide Gate Operator INSTALLATION MANUAL

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

INSTALLATION INSTRUCTIONS AND USER GUIDE. ControlHoist Optima. Model COT. Industrial Duty GEARHEAD DRIVE Trolley

PowerMaster MODEL MBG. Installation Manual U L R UL 325 AND UL 991 LISTED MEDIUM DUTY BARRIER GATE OPERATOR TABLE OF CONTENTS

OWNER'S MANUAL. MGJ (S-Series) MODEL INDUSTRIAL DUTY DOOR OPERATOR FOR USE WITH SS90 FIRE DOOR CONTROLLER 2 YEAR WARRANTY NOT FOR RESIDENTIAL USE

MEDIUM DUTY DOOR OPERATOR MODELS MJ5011U, MH5011U, MHS5011U, & MGJ5011U

MEDIUM DUTY DOOR OPERATOR MODELS MJ5011U, MH5011U, MHS5011U, & MGJ5011U

MEDIUM DUTY DOOR OPERATOR MODELS MT5011U & BMT5011U

FOR CLASS I, II, III, IV VEHICULAR GATE OPERATORS

MO-S SERIES MO-S SERIES SOLID STATE COMMERCIAL

C2 Wiring 2 YEAR WARRANTY NOT FOR RESIDENTIAL USE. Serial # Box. Installation Date. Wiring Type. See page 7 for other wiring configurations

Vertical Vinyl Curtain Door

RollSeal 1733 County Road 68 Bremen, Alabama Part No Rev Owner s Manual RS-Divider Curtain

BOLT-ON AND WELD-ON FLUSH FLOOR SLIDEOUT SYSTEMS OPERATION AND SERVICE MANUAL

OWNER'S MANUAL MODEL GH 5HP HEAVY DUTY DOOR OPERATOR 2 YEAR WARRANTY. Serial # (located on electrical box cover) Installation Date.

Model 2300JL Installation Guide

APOLLO Gate Operators, Inc.

Best Diversified Products, Inc. Product Manual. BestReach Rigid Belt. Models BRB 230 OS BRB 230 SS BRB 460 OS BRB 460 SS

Logic 5.0 Commercial Door Operator INSTALLATION MANUAL

FOR CLASS I, II, III, IV VEHICULAR GATE OPERATORS

Model H/HB Heavy-Duty Industrial Drawbar Door Operator Safety, Installation and Service Manual

INSTALLATION AND OWNER S MANUAL

AUTOMATIC CONTROL ROLLING DOOR OPENER

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION AND OWNER S MANUAL

Installation and Maintenance Manual

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

INSTALLATION AND OWNER S MANUAL M50JF & M50JH M-SERIES JACKSHAFT COMMERCIAL VEHICULAR DOOR OPERATORS

RAMSET

The Da-Lite Difference.

User s Manual. Automatic Switch-Mode Battery Charger

INSTRUCTION BOOK FOR. Tensioned Large Advantage Deluxe Electrol

ALL W INSTALLATION INSTRUCTIONS

ALL700/ALL700-CM INSTALLATION INSTRUCTIONS

LMPLC EES SERIES COMMERCIAL/INDUSTRIAL DUTY EGRESS DOOR OPERATOR. B2/C2 Wiring 2 YEAR WARRANTY LMPLC CONTROL NOT FOR RESIDENTIAL USE.

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

COOKSON OWNER'S MANUAL

GARAGE DOOR OPENER OWNER S MANUAL S3/S4

Photoelectric. Sensors Invisible Light Beam Protection Area

Lbs Kgs Ft M

R3 Roller Garage Door Opener

Instruction Manual MB4 Rolling garage door opener

Roller Door Operator

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

Transcription:

Installation & Instruction Manual Opera-H (OPH) Opera-J (OPJ) Opera-HJ (OHJ) Opera-SH (OSH) Commercial & Industrial Heavy Duty Jackshaft Operator (For sectional doors, rolling doors and grilles) Electrical Control (BOARD 070E) READ AND FOLLOW ALL INSTRUCTIONS. SAVE THESE INSTRUCTIONS. GIVE TO END-USER. Serial # Model # Wiring Diagram # Project #/Name Door #/Name For more information, please visit www.devancocanada.com or call toll free at 855-9-

TABLE OF CONTENTS Installation Instructions... General Specifications and Dimensions (OPH / OPJ / OHJ)... General Specifications and Dimensions (OSH)...5 Door & Operator Hardware...6. Delivery of Operator...6. Hardware Supplied...6 Operator Installation...7.. 5 6 7 8. Sprockets, Spreader Bar and Drive Chain Installation...8 Operator Control Box...9 Manual Hand Chain and Disconnect Chain...0 6. Installation...0 6. Operating Mode... Limit Switches & Limit Cams: Adjustment & Functionality... 7. 7. Limit Switch Adjustments: Open and Close Cam Settings... Limit Switch Functionality... 7. 7. Limit Switch Adjustment Using Manual Hand Chain (if applicable)... Limit Switch Adjustment Without Manual Hand Chain (if applicable)... Electrical Wiring...5 8. Low Voltage (Controls) and High Voltage (Power) Connections...6 8. 8. 9 Operator Mounting Options...7 Operator Mounting Holes...7 Main Power Supply Connection...6 Wall-Button Connection...7 8. Optional Accessory Connections...8 Operator Start-up... 0 Clutch Adjustment... Electronic Control Board (ECB) BOARD 070E..... General Layout... On-Board LED Monitoring Status...5. Electronic Control Board (ECB) Programming...7 User Instructions... 0 Quick Fix Instructions... Maintenance Instructions... Preventative Maintenance Schedule.... Mechanical Inspection..... Troubleshooting Guide...6 Electrical Drawings...8.. Electrical Inspection... Band Brake Maintenance... Phase Operator with BOARD 070E...8 Phase Operator with BOARD 070E...9. External Wiring with BOARD 070E...0 Mechanical Exploded Views and Replacement Components..... Opera-H... Opera-J..... Opera-HJ... Opera-SH....5.6 Opera Brake...5 Opera Control Box with BOARD 070E...6.7 Replacement Motors, Transformers, Solenoids and Resets...6 Notes... 8 Warranty... 5 For technical support, please call -800-6-60 or visit www.manaras.com for more information

Installation Instructions IMPORTANT INSTALLATION INSTRUCTIONS WARNING TO REDUCE THE RISK OF SEVERE INJURY OR DEATH TO PERSONS:. READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS.. Install only on a properly operating and balanced door. A door that is operating improperly could cause severe injury. Have qualified service personnel make repairs to cables, spring assemblies and other hardware before installing the operator.. Remove all pull ropes and remove, or make inoperative, all locks (unless mechanically and/or electrically interlocked to the power unit) that are connected to the door before installing the operator.. Installation of this door operator must be done by a qualified installer. 5. Verify that the operator is correct for type, size of door and frequency of use per the operator specifications. 6. Install the door operator at least 8 feet (, m) or more above the floor if the operator has exposed moving parts. 7. Do not connect the door operator to the source of power until instructed to do so. 8. Locate the control station: (a) within sight of the door, (b) at a minimum height of 5 feet (,5 m) so small children cannot reach it, and (c) away from all moving parts of the door. 9. Install the Entrapment Warning Placard next to the control station in a prominent location. 0. For products having a manual release, instruct the end user on the operation of the manual release.

General Specifications and Dimensions (OPH / OPJ / OHJ) SUPPLY VOLTAGE...5, 0 VAC single-phase, 08, 60, 575 VAC three-phase CONTROL VOLTAGE... VAC class transformer, amp fuse type ACG MOTOR...Continuous duty /, /, horsepower OPERATOR OUTPUT SPEED... RPM NET WEIGHT (Operator only)...86 Lbs (9 Kg) for /HP 5V Opera-H model STANDARD WIRING TYPE...C (momentary contact to open/stop and constant-pressure-to-close) APPLICATION...Heavy duty for sectional doors, rolling doors and grilles DUTY...5 cycles/hour or 00 cycles/day maximum Figure - Opera-H, Opera-J and Opera-HJ Dimensions Table - Operator Selection Guide (OPH / OPJ / OHJ) Maximum Area in Square Feet (general guideline) Rolling Doors Insulated HP Steel 6 ga Steel Sectional Doors Alu. Grilles Steel Grilles Alu. Door 0 ga ga ga Steel Steel Steel Steel 8 ga ins. Wood Steel 8 ga Steel 0 ga, Alu. Steel 0 ga & ga & ga ins. ins. Fiber Glass ½ 57 6 60 9 58 96 5 9 ¾ 06 9 58 5 55 70 9 90 59 55 58 6 57 6 9 9 90 56 6 For technical support, please call -800-6-60 or visit www.manaras.com for more information

5 General Specifications and Dimensions (OSH) SUPPLY VOLTAGE...5, 0 VCA single-phase, 08, 60, 575 VAC three-phase CONTROL VOLTAGE...V AC class transformer, amp fuse type ACG MOTOR...Continuous duty /, /, horsepower OPERATOR OUTPUT SPEED... RPM NET WEIGHT (Operator only)...96 Lbs ( Kg) STANDARD WIRING TYPE...C (momentary contact to open/stop and constant-pressure-to-close) APPLICATION...Ultra high-end heavy duty v-belt drive for sectional doors, rolling doors and grilles DUTY...5 cycles/hour or >00 cycles/day Figure - Opera-SH Dimensions Table - Operator Selection Guide (OSH) Maximum Area in Square Feet (general guideline) Rolling Doors Insulated HP Steel 6 ga Steel Sectional Doors Alu. Grilles Steel Grilles Alu. Door 0 ga ga ga Steel Steel Steel Steel 8 ga ins. Wood Steel 8 ga Steel 0 ga, Alu. Steel 0 ga & ga & ga ins. ins. Fiber Glass ½ 57 6 60 9 58 96 5 9 ¾ 06 9 58 5 55 70 9 90 59 55 58 6 57 6 9 9 90 56 6 For technical support, please call -800-6-60 or visit www.manaras.com for more information

6 Door & Operator Hardware. Delivery of Operator Upon delivery of your OPERA jackshaft operator, inspect the unit immediately for any shipping damages. Verify that you have received all the hardware parts pertaining to your operator model, as listed in Table and shown in Figure. If ordered, other items such as radio controls or other types of optional equipment may be present. If any item is missing or if there is evidence of damage, call the transport company or your direct supplier.. Hardware Supplied Table - Standard Hardware Parts Supplied No Qty Description -Push-button station (open/close/stop) Operator sprocket () Door sprocket () #/#50 Drive chain, ft () () 5 #/#50 Chain link () 6 5/6-8 x 5/6 Set screw 7 Key / x -/ 8 Pocket wheel hand chain, ft () () 9 Chain keeper for hand chain () 0 Disconnect chain, ft () (5) Chain keeper for disconnect chain Handle for disconnect chain Entrapment Warning Placard () () () () (5) Lxxxx Hxxxx Gxxxx HDHBAG (5) (5) Figure - Standard Jackshaft Hardware Dif f ers according to operator model and door characteristics 5f t f or /5/60 tooth door sprocket, 8f t f or 7 tooth door sprocket Quantity = times door shaf t height minus f t Only supplied with OMH/OPH/OHJ/OBH/OSH/OGH/MGH/GH Only supplied with OMJ/OPJ/OSH/MGH/GH Figure - Entrapment Warning Placard NOTE: Install the Entrapment Warning Placard (shown in Figure ), next to the control station, visible in the area of the door. For technical support, please call -800-6-60 or visit www.manaras.com for more information

7 Operator Installation. Operator Mounting Options The jackshaft operator line has a dual output shaft. These operators may be wall-mounted on either the left hand side or the right hand side of a sectional door. They can also be hood-mounted, using BRACKET (sold separately), or shelf-mounted on either side of the door. The standard jackshaft hoist model comes with a chain hoist located on the right of the operator. If the application requires that the chain hoist be on the left (ex: rolling doors, left operator hood mounting), it must be requested at time of order. Do not attempt to modify the chain hoist yourself. This operator is not intended to be installed on horizontal slide doors. Figure 6 - Right Side Hood Mount with BRACKET (Chain Hoist on Right) Figure 5 - Right Side Wall Mount (Chain Hoist on Right). Operator Mounting Holes CAUTION To prevent access to the pinch points, this operator must be installed a minimum of 8 feet (,m) above the floor.. Ensure that the wall or mounting surface provides adequate support for the operator. The surface must be rigid enough to prevent any play between the operator and door shaft. Manaras-Opera recommends the use of BRACKET for hood-mount application.. Locate the four mounting holes, as shown in Figure 7.. The optimum distance between the door shaft and the operator drive shaft is between " and 5".. Secure BRACKET to the end bracket of the rolling door or mount the operator to the wall with /8" thrubolts. If the wall construction prohibits the use of thrubolts, then appropriate and sufficiently sized lag bolts and anchors may be used. 5. Only tighten the bolts after having adjusted tension of the drive chain, as shown in section., p.8. 6. Ensure that the door and operator shafts are parallel. Figure 7 - Opera Mounting Holes For technical support, please call -800-6-60 or visit www.manaras.com for more information

. 8 Sprockets, Spreader Bar and Drive Chain Installation The hardware components shown in Figure 8 have been supplied with your operator.. Place the door sprocket loosely on the door shaft.. Place the operator drive sprocket on the appropriate side of the operator and align it with the drive sprocket of the operator.. Lock the operator and door sprockets in place by inserting the keys and tightening their respective set screws.. Wrap the operator drive chain around the door sprocket and the operator sprocket. Shorten the drive chain to the appropriate length. Use the chain link to attach the operator drive chain together. 5. Slide the operator to tighten the drive chain and then firmly tighten the mounting bolts. 6. Check the tension on the chain (there should be no more than a /" of slack when the chain is depressed between the sprockets). 7. Manaras-Opera recommends the use of a chain spreader (sold separately). Set Screw Door Sprocket Key Spreader Collar Door Shaft Drive Chain Chain Spreader Washer /8 Bolt /8-6 (To attach chain spreader) Nut /8-6 Lock Washer /8 7 6 5 Key Operator Shaft Operator Sprocket Spreader Collar Figure 8 - Hardware Components For technical support, please call -800-6-60 or visit www.manaras.com for more information

9 5 Operator Control Box To open the control box cover, loosen the screw at the base of the cover. If the cover cannot be fully opened, the retaining arm may be used to hold the cover in other positions, see Figure 9. After installation, allow for proper clearance upon opening the control box cover. If the cover is obstructed from opening, it is possible to remove the cover by unscrewing it from the box, see Figure 0. Always close the cover before operating the door. Screws Retaining Arm Figure 9 - Open Control Box Cover Figure 0 - Unscrewing Screws from Control Box Cover For technical support, please call -800-6-60 or visit www.manaras.com for more information

0 6 Manual Hand Chain and Disconnect Chain 6. 6.. Installation Chain Hoist (Opera-H / SH / HJ) Before pulling the hand chain through the pocket wheel, pull the limit cam's retaining bracket back. Turn the cams to the center of the limit shaft to be sure that they are not being mechanically driven through their normal limit switch end positions.. Run the hand chain through the pocket wheel and through the chain guide, see Figure.. Allow both ends of the chain to hang down toward the ground until both ends are approximately feet (0.6 m) from the floor. Cut the hand chain if necessary.. Connect both ends of the hand chain together. Figure - Hand Chain Installation 6.. Disconnect Chain (Opera-J / SH). Link the disconnect chain to the hook located at the extremity of the operator's disconnect mechanism, see Figure.. Install the handle under the chain keeper to facilitate handling of the chain.. Under the handle, make a knot in order to fasten the end of the chain. Disconnect Mechanism from Operator Disconnect Chain Chain Keeper Handle Figure - Disconnect Chain 6.. Emergency Egress (Opera-HJ) This operator is built to receive a quick disconnect in case of an emergency egress.. Pass the cable housing (from the emergency egress control) through the holes provided on the frame of the operator, see Figure.. Attach the end of the egress cable to the disconnect lever.. Secure positioning of the cable housing with two adjustment collars. Figure - Emergency Egress For technical support, please call -800-6-60 or visit www.manaras.com for more information Knot

6. 6.. Operating Mode Opera-H (Hoist-a-matic Chain Hoist System) The automatic emergency chain hoist disconnect mechanism is provided in order to operate the door manually. A floor level disconnect is not required. In one simple step and by pulling the hand chain in the desired direction, the following operations may be successfully completed, see Figure.. Manual Mode. Return to Electric Mode Pull chain on either side to operate door. Wiggle chain until it moves freely.. Storage Follow the steps shown below to attach the chain (when not in use) to the chain keeper. LE G IG W LL U P E R TO S Figure - Hoist-a-matic 6.. Opera-J This operator has a floor level disconnect to disconnect the door from the electrical motor and is ready to be manually operated, see Figure 5. Disconnect Chain Chain Keeper Pull the handle and attach the disconnect chain to the chain keeper for manual operation. Release the tension from the disconnect chain to return to electrical mode. Handle Figure 5 - Floor Level Disconnect Chain For technical support, please call -800-6-60 or visit www.manaras.com for more information

6.. Opera-HJ See section 6.. for Chain Hoist Operation or see section 6.. for Direct on-the-door Manual Operation. Activation of the quick disconnect keeps the operator disconnected mechanically and electrically for manual operation. 6.. Opera-SH This operator has a floor level hoist engagement lever to: disconnect the electrical control of the operator release the brake engage the manual hoist mechanism, see Figure 6 Disconnect Chain Chain Keeper. Engagement. Return to Electrical Mode Pull the handle and attach the disconnect chain to the chain keeper for manual operation. Release the tension from the disconnect chain to return to electrical mode. Handle. Manual Mode. Storage Pull chain on either side to operate door. Follow the steps shown below to attach the chain (when not in use) to the chain keeper. LL U P E R O T S Figure 6 - Hoist Engagement and Hoist Operation For technical support, please call -800-6-60 or visit www.manaras.com for more information

7 Limit Switches & Limit Cams: Adjustment & Functionality WARNING To reduce risk of SEVERE INJURY or DEATH to persons: Do not attempt to make limit switch adjustments unless power has been electrically disconnected. 7. Limit Switch Adjustments: Open and Close Cam Settings This operator is equipped with the ACCU-CAM feature, for precise and quick one-handed limit setting adjustments. To adjust the limit cams, see Figure 7.. Pull the cam's retaining bracket back.. Turn the cams for limit adjustment: turning cams toward the center of the limit shaft increases door travel or turning the cams toward the limit switch decreases door travel. Open Side Cam Retaining Bracket Close Side Close Cam Open Cam Decrease Door Travel Increase Door Travel Open Limit Switch Adv. Close Limit Switch Figure 7 - Limit Cam Adjustment 7. Limit Switch Functionality Open Limit Switch and Advanced Open Limit Switch When activated, the Open Limit Switch will stop the operator while the door is travelling in the upward direction. Should be adjusted accordingly to stop door in fully open position. The microprocessor has a built-in program that replaces the Advanced Open Limit Switch. Close Limit Switch and Advanced Close Limit Switch Close Limits are not present on operators with an ECB. In it's place, the microprocessor has a built-in patented Advanced Close Time feature. While the door is travelling downwards and once the Advanced Close Limit Switch is activated, the door will stop after 00 milliseconds. The distance travelled varies according to the speed of the door. The value is fixed and cannot be re-programmed or adjusted. For technical support, please call -800-6-60 or visit www.manaras.com for more information

7. Limit Switch Adjustment Using Manual Hand Chain (if applicable) Table - Limit Switch Adjustment Procedures Limit Switch Adjustment Procedures Open Limit. Using the hoist, manually raise the door to a nearly opened position or desired open position.. Pull the cam-retaining bracket from the Open side, see Figure 7, and rotate the Open cam manually until it activates the Open Limit Switch sufficiently so that a click can be heard.. Release the cam-retaining bracket and make sure that the bracket engages in the slots of both cams. Advanced Close Limit. Using the hoist, manually lower the door to approx. 6 above the ground.. Pull the cam-retaining bracket from the Close side, see Figure 7, and rotate Close cam manually until it activates the Close limit switch sufficiently so that a click can be heard.. Release the cam-retaining bracket and make sure that the bracket engages in the slots of both cams. Limit Switch Fine Adjustment. Limit switch fine adjustment SHOULD be done after the main power supply is connected to the operator. Refer to section Operator Start-up, Table 6, p.. Note: One () notch on cam is equal (=) to about ½ of the door travel. 7. Limit Switch Adjustment Without Manual Hand Chain (if applicable) Table 5 - Limit Switch Adjustment Procedures (no hoist) Limit Switch Adjustment Procedures Open Limit. Move the open cam close to the open limit switch and proceed as per described in section Operator Start-up, Table 6, p... Release the cam-retaining bracket and make sure that the bracket engages in the slots of both cams. Advanced Close Limit. Pull the disconnect chain for manual operation.. Manually open the door approx. 6 above the ground.. Pull the cam-retaining bracket from the Close side, see Figure 7, and rotate Close cam manually until it activates the Close limit switch sufficiently so that a click can be heard.. Release the cam-retaining bracket and make sure that the bracket engages in the slots of both cams. Limit Switch Fine Adjustment. Limit switch fine adjustment SHOULD be done after the main power supply is connected to the operator. Refer to section Operator Start-up, Table 6, p.. Note: One () notch on cam is equal (=) to about ½ of the door travel. For technical support, please call -800-6-60 or visit www.manaras.com for more information

5 8 Electrical Wiring WARNING To reduce risk of SEVERE INJURY or DEATH to persons: All electrical wiring should be done by a qualified professional and in accordance to local electrical codes. Always shut OFF the main power before performing any electrical intervention. Use proper wire gauge for incoming power line and for accessory connections. Install operator main circuit breaker next to operator for easy access for power shut-off. Use separate knockouts on operator control box for accessories and main power cables. Always separate low and high voltage wires. Operator should be properly grounded to the building ground and to the main power supply ground lug. Always use suitable and appropriate rating circuit breakers for operator protection. Compare available power supply voltage to voltage on operator name plate prior to electrical connection. Failure to connect appropriate power supply voltage may cause serious damage to the operator. NOTICE THE OPERATOR MUST BE ADEQUATELY PROTECTED AGAINST OVERCURRENT AND SHORTCIRCUIT. PLEASE REFER TO LOCAL ELECTRICAL CODE. PLEASE REFER TO NATIONAL ELECTRIC CODE (NFPA 70) ARTICLE 0 SECTION IV (0.5 / 0.5 / 0,5). PLEASE REFER TO CANADIAN ELECTRIC CODE (CSA.) SECTIONS 8-00 / 8-06. FLA = Full Load Amp Guideline to determine the branch-circuit rating of the protective device [A]: Time Delay Fuse:,75 x FLA Non-Time Delay Fuse:,0 x FLA A fuse that does not exceed the next higher standard ampere rating shall be permitted. Example: If FLA =,8A Time Delay Fuse:,75 x,8a = 6,65A Standard fuse to use: 0A Non-Time Delay Fuse:,0 x,8a =,A Standard fuse to use: 5A For technical support, please call -800-6-60 or visit www.manaras.com for more information

6 NOTICE The installer MUST test for proper connection and functionality of the operator and its accessories before leaving the job site. The installer should also perform a demonstration for the end-user. 8.... Low Voltage (Controls) and High Voltage (Power) Connections Route the power line wires either from the right or from the left of the control box, as shown in Figure 8. Route all low voltage control wires, as shown in Figure 8. KEEP LOW VOLTAGE WIRES SEPARATE FROM LINE VOLTAGE WIRES. USE COPPER CONDUCTORS ONLY. Power Control Figure 8 - Low Voltage (Controls) and High Voltage (Power) Connections Main Power Supply Connection NEUTRAL LIVE Ground Lug Three-Phase (08/0-60-575V) Power Terminal Block Ground Lug Single-Phase (5/0V) Line Line Power Terminal Block 8. Line Correct motor rotation: Switch the BLUE and ORANGE Correct motor rotation: Switch ANY TWO incoming lines motor wires on the power board. (phase) on the power terminal block. For technical support, please call -800-6-60 or visit www.manaras.com for more information

7 8. Wall-Button Connection WARNING Wall controls must be mounted in clear view of the door, far enough from the door, or positioned such that the user is prevented from coming in contact with the door while operating the controls and at least 5 feet (,5 m) above the standing surface. Keep low voltage wires separate from line voltage wires. Use copper conductors only. 8 Figure 9 - STATION 00 / 08 -PBS Open / Close / Stop Link (Lier) Open/Close/Stop COM 8 NO STOP (ARRÊT) Figure - STATION 079 -PBS Open / Close / Stop with Key Lock-out VAC OPN OPEN (OUVERTURE) 6 CLS CLOSE (FERMETURE) 8 COM 9 STOP KEY (CLÉ) LED 7 VAC Link (Lier) Open/Close/Stop Link (Lier) Open/Close/Stop KEY (CLÉ) NO STOP 9 NO COM 8 NC CLS CLOSE (FERMETURE) 6 STOP Figure 0 - STATION 0 / 09 / 056 / 076 / 078 -PBS Open / Close / Stop NO OPEN (OUVERTURE) 9 STOP COM OPN CLOSE (FERMETURE) NC STOP (ARRÊT) 7 CLS CLOSE NO STP 6 OPEN 9 OPEN (OUVERTURE) NO CLOSE (FERMETURE) OPN 6 CLS 7 NC OPEN (OUVERTURE) OPN NO 7 NO Push-Button Station (PBS) Connection Figure - STATION 00 / 08 -PBS Open OPEN (OUVERTURE) 6 CLS CLOSE (FERMETURE) 8 COM Figure - STATION 00 / 08 -PBS Open / Close For technical support, please call -800-6-60 or visit www.manaras.com for more information Link (Lier) Open/Close OPN NO COM 7 8 OPEN (OUVERTURE) NO OPN 7 NO Figure - STATION 080 -PBS Open / Close / Stop with Key Lock-out and Light

8 8. Optional Accessory Connections NOTICE Keep low voltage wires separate from line voltage wires. Use copper conductors only. 8.. Electric Photo Cells / Photo Eyes (Non-Monitored) Through Beam Type TK-800 Interface Module Always set the jumper located inside the Interface Module on N.O. (Normally Open) JMP NO SNS VAC COM 5 Pwr 6 Pwr 5 Pwr Pwr VAC Com NC RELAY OUT NC TX NO POWER BEAM RX 5 BLACK BLACK & WHITE BLACK & WHITE VAC COM RECEIVER ALIGNMENT TRANSMITTER SNS 5 VAC BLACK Figure 5 - PHOTO 008 Figure 6 - PHOTO 05 / 06 / 05 / 050 / 05 / 059 Reflective Type COM 5 SNS C [] NO [] (NOT USED) NC [] 5 NC [] NO [5] VAC VAC C [6] P P Figure 7 - PHOTO 08 COM VAC VAC SNS BLACK (NO) ORANGE (COM) BROWN BLUE WHITE (NC) Figure 8 - PHOTO 08 VAC 5 SNS COM VAC Pwr Pwr NC NO COM 5 Figure 9 - PHOTO 060 For technical support, please call -800-6-60 or visit www.manaras.com for more information

9 8.. Reversing Edge Device (Non-Monitored) NOTICE If the door is controlled by any device other than a constant pressure push-button station on close, including a timer-to-close, a reversing edge must be connected. Installation Pneumatic Sensing Edge. Place the air switch in position, refer to Figure 0.. Place the air hose in position.. Use a coil cord or take-up reel to connect the air switch to the operator terminals. Install electric wires according to Figure or Figure.. Connect one end of the air hose to the air switch. 5. Place the air plug in the other end of the air hose. Electric Sensing Edge. Place the junction box in position, refer to Figure 0.. Place the sensing edge in position.. Use a coil cord or take-up reel to connect the sensing edge wires to the operator terminals. Install electric wires according to Figure.. Connect the sensing edge to the junction box. 5. N/A 5 Figure 0 - Reversing Edge Adjustment screw (Vis d'ajustement) 5 COM SNS RED YELLOW (NO) COM WHITE SNS GREEN (NO) Figure - AIRSWITCH 00 / 007 5 Figure - AIRSWITCH 009 COM SNS 5 -Wire Edge Barre -fils Figure - Electric Reversing Edge For technical support, please call -800-6-60 or visit www.manaras.com for more information

0 8.. Pull Cord & Key Switch OR (OU) 7 COM O/C For OPEN only N.O. COM (Seulement pour OUVERTURE) Figure - PULLCORD 00 / 00 / 00 / 007 -Position Key Switch -Position Key Switch & Stop Button Recommendation: Put Control Board on C or E Mode (constant-pressure-to-close) CLS OPN NO COM 6 7 7 Place a jumper between #8 & #9 on the board (Installer un cavalier entre #8 & #9 sur la plaquette) NO COM COM 6 OPN CLS NO COM 8 Figure 5 - KEYSWITCH 00 / 05 8 COM 9 STP COM STOP BUTTON Figure 6 - KEYSWITCH 09 For technical support, please call -800-6-60 or visit www.manaras.com for more information NO

8.. External Single-Button Radio Control Receiver POWER POWER Manaras Mount the Radio receiver directly on the terminal strip provided on the side of the control box GND RADIO POWER RELAY VOLTS COM CONTACT X X X CONTACT VAC NO CONTACT NC CONTACT Figure 7 - RADIO 0 or RADIO 05 8..5 VAC VAC COM O/C (NOT USED) Figure 8 - Other Radio Receivers with or 5-wires Vehicle Loop Detector VAC O/C BLACK VAC WHITE COM YELLOW OR (OU) 5 BLUE (NO) SNS OR (OU) LOOP BROWN LOOP (BOULCE) GRAY Tw ist the tw o () leads (w ires) a minimum of 6 tw ists/foot Figure 9 - Vehicle Loop Detector 8..6 Other Accessories Additional accessories are available, such as: Plug-In Radio Receiver Universal Auxiliary Output Module External Mid-Stop Switch External Timer Defeat Switch Please contact your dealer or our inside sales department at -800-6-60 for further information. For technical support, please call -800-6-60 or visit www.manaras.com for more information

9 Operator Start-up WARNING To reduce risk of SEVERE INJURY or DEATH to persons: Personnel should keep away from a door in motion and keep the moving door in sight until it is completely closed or opened. NO ONE SHOULD CROSS THE PATH OF A MOVING DOOR. Never go under a stopped, partially opened door.. Turn power ON.. Use on-board, wall-button station (Open/Close/Stop), external entrapment device or jumper wires for testing, see Table 6. Table 6 - Start-up and Testing Guide Test Open Close Sense Edge Open & Close (singlebutton radio) Door Position Door at 6 from the closed position Door at fully open position A) Door at fully closed position B) Door is closing (movement) A) Door at fully opened position B) Door at fully closed position C) Door is closing (movement) Action. Press OPEN.. Check if door is stopped by Open limit switch.. If required, re-adjust Open limit, as shown in Figure 7, p... Press CLOSE.. Check if door is stopped by Close limit switch.. If required, re-adjust Close limit, as shown in Figure 7, p.. Activate external entrapment device OR Momentarily touch # & #5 on the main terminal with a jumper wire. Activate the single-button transmitter OR Momentarily touch # & # on the main terminal with a jumper wire. Door Response Door should open instantly. - C mode: (selector switch on C=0). Door should close as long as the close button is activated. - B mode: (selector switch on B=). Door should close instantly. Door should stay at closed position. Door should stop and then reverse to fully opened position. Door should close. Door should open. Door should reverse to fully opened position. LED Status OPEN LIMIT LED is ON CLOSE LIMIT LED is ON SENS LED is ON as long as the contact is maintained O/C LED is ON as long as the contact is maintained (+/- sec) For technical support, please call -800-6-60 or visit www.manaras.com for more information

0 Clutch Adjustment NOTICE The friction clutch is NOT intended to protect people. It is designed to protect the operator and door system against potential damage. The friction clutch is factory adjusted during final testing. Proper adjustments should be done on site according to the door characteristics and application. In order to avoid the door from getting damaged when the lock is on, the friction clutch must be properly adjusted according to the instructions below. Best Practices Encouraged by Manaras-Opera On sectional doors : Manaras-Opera recommends the installation of a hard stop at the end of the tracks (ex. bolt, deformation of tracks, bumper spring, pusher spring, etc). With such installation, the door is prevented from running out of the tracks. The clutch (torque limiter) will prevent any damage to occur to the door system. This operator is supplied with a Door Lock Sensor feature. The door lock sensor feature prevents the door from getting damaged when the door lock hasn't been removed prior to electronic operation. It eliminates the need of external interlock wiring. This feature can only be used on operators equipped with a friction clutch. When the lock stops the door, the clutch slips and in less than second, the door will reverse a fraction of a second to release the tension on the lock. - Torque Jam Nuts + Torque Figure 0 - Clutch Adjustment To adjust the clutch:. Unlock the jam nuts with two () 5/6 keys, refer to Figure 0.. Rotate the nut counter-clockwise to release the tension.. Gradually rotate the nut clockwise until there is just enough tension to permit smooth operation (while still allowing the clutch to slip if the door is obstructed).. Lock the jam nuts. For technical support, please call -800-6-60 or visit www.manaras.com for more information

Electronic Control Board (ECB) BOARD 070E. General Layout JP for Phase Power Socket Indicator LED D / D LED D / D / D Output Module Socket Control Socket Rotary Selection Switch JP for Hoist Microprocessor (Chip) Amp Fuse Radio Receiver Socket LED D LED D5 / D6 LED D0 / D External Accessories Terminal Strip LED D7 / D8 / D9 On-Board Push-Buttons Figure - Electronic Control Board BOARD 070E For technical support, please call -800-6-60 or visit www.manaras.com for more information

5. On-Board LED Monitoring Status The electronic control board's LEDs help with wiring and troubleshooting diagnostics. Every LED indicates the status of the door. BOARD 070E has a non-volatile memory and the LEDs return to their initial state after a power interruption. Refer to Figure, p. as reference. Table 7 - LED Monitoring Status LED Color D GREEN D / D LED Status ON Functions Indicates presence of VDC. Refer to Table 8, p.6 as reference. D5 RED ON Only when single-button radio transmitter is activated (stays ON for +/- sec). D6 RED ON When reversing or sensing edge is activated. D7 RED ON When close command is activated. D8 RED ON When open command is activated. D9 YELLOW ON Indicates that the stop button is connected and hoist or disconnect switch is not engaged. D0 RED ON When inductive loop is activated (when loop is activated, door could be closed only on constant pressure). D RED ON When external timer to close defeat switch is activated (if used). D RED ON When open limit switch is activated. D RED ON When external mid-stop limit switch is activated (if used). D RED ON When close limit switch is activated. For technical support, please call -800-6-60 or visit www.manaras.com for more information

6.. D / D LED Monitoring Status Combination Scenarios Table 8 - D/D LED Monitoring Status - Combination Scenarios Scenario D LED GREEN D LED RED Functions OFF OFF Indicates a failure of the 5VDC. OFF Flash ON OFF ON Flash 5 ON ON 6 Flash OFF 7 Flash Flash When timer to close is counting before closing the door. 8 Flash Flash When door is opening during programming of the run timer or the mid-stop features. Refer to section.., p.8 as reference. When door is closing. When operator is on standby. Indicates wrong handling feature activation (if open limit switch is not released within.6 sec while door starts to close from fully open position). Indicates that the motor centrifugal switch is OFF (single-phase only). When door is opening. For technical support, please call -800-6-60 or visit www.manaras.com for more information

7. Electronic Control Board (ECB) Programming WARNING To reduce risk of SEVERE INJURY or DEATH to persons: Manaras-Opera strongly recommends the use of external entrapment protection devices, especially in the case of momentary contact to close (B wiring or Timer to Close)... Run Mode Settings NOTICE Always return the door to fully closed position before performing any program settings. C Mode Selector switch position on 0 B Mode Selector switch position on D Mode Selector switch position on SET SELECT SWITCH ON C = 0 Function: Momentary contact to open and stop, constant-pressure-toclose with -button station. Activation of entrapment protection devices will reverse the door while closing. Auxiliary devices function as an Open control and will reverse the door while closing. SET SELECT SWITCH ON B = Function: Momentary contact to Open, Close and Stop with -button station. Activation of entrapment protection devices will reverse the door during closing. Auxiliary devices function as an Open-Close controls and will reverse the door while closing. SET SELECT SWITCH ON D = Function: Constant-pressure-toopen and constant-pressure-to-close. Activation of entrapment protection devices will stop the door while closing. E Mode Selector switch position on T Mode Selector switch position on TS Mode Selector switch position on 5 SET SELECT SWITCH ON E = Function: Momentary contact to open and constant pressure to Close. Release of Close button or activation of entrapment protection devices will reverse the door to fully open position. SET SELECT SWITCH ON T = Function: Under Mode T=, if entrapment protection devices are activated while door is closing, the door will reverse and will not close by Timer to Close (TTC). TTC will also be disabled if the chain hoist is engaged or if the stop is activated before elapsed time. TTC will resume its normal operation only after the door is fully closed. SET SELECT SWITCH ON TS = 5 Function: Under Mode TS=5, if entrapment protection devices are activated while door is closing, the door will reverse and will close by Timer to Close (TTC). TTC will also be refreshed if the chain hoist is engaged, if the stop is activated before elapsed time or in the case of a power outage. T () & TS (5) Mode: Only applicable with Timer to Close, refer to Features Programming section, p. 8. For technical support, please call -800-6-60 or visit www.manaras.com for more information

8.. Features Programming NOTICE Always return the door to fully closed position before performing any program settings. Maximum Run Timer Maximum run timer is set to 90 seconds by default. When programmed, this feature calculates the total time required for the door to travel from the fully closed to the fully opened position and adds 0 seconds to this time. Therefore, if the door is obstructed while travelling up or down, this feature will stop the operator after the maximum run timer time has elapsed. Run Timer Programming Select Switch. Verify if close limit switch is activated and if close LED is ON.. Set select switch on D = Run Tm.. Press Open button and let the door reach the fully opened position. Result: 0 sec is added to the total travel time.. Set select switch on run mode (0,,,, or 5). Set Run Timer to Default. Verify if close limit switch is activated and if close LED is ON.. Set select switch on D = Run Tm.. Press Stop button. Result: The max. run timer is set to the default value of 90 sec.. Set select switch on run mode (0,,,, or 5). Timer to Close (TTC) Timer to Close (T = or TS = 5 Mode), will close the door from the fully opened and mid-stop positions after a factory preset time (5 sec.). Timer to Close can be programmed in increments of sec. or 5 sec. TTC Programming Select Switch. Verify if close limit switch is activated and if close LED is ON.. Set select switch on B = Tm Cls.. Press the Stop button to return the time to 0 sec. or to reprogram.. Press Open button to add 5 sec. increments, or press Close button to add sec. increments. Max. min. 5. Set select switch on T = or TS = 5. Refer to Run Mode Settings section, p. 7 for mode descriptions. TTC Deactivation. If the TTC is not required, set select switch on run mode (0,,, or ). Timer to Close User Suspension Feature This feature allows the Timer to Close to be enabled/disabled from the floor by using a wall push-button station. This feature allows the user to keep the door opened for ONE CYCLE only. TTC Deactivation While the door is in the closed position, by pressing the Stop button times and the Close button times consecutively on the push-button station, the TTC is deactivated (TTC is suspended). TTC Activation The TTC is re-activated (TTC returns to normal function) when the door is closed. For technical support, please call -800-6-60 or visit www.manaras.com for more information

9 Mid-Stop (MD STP) Mid-Stop, when activated, will allow the door to stop at a predetermined position when an open signal is given from the fully closed position. The Radio control or Close push-button will close the door from the mid-stop position. The door will open fully from mid-stop position if the Open button is activated. Mid-Stop Activation Select Switch. Verify if close limit switch is activated and if close LED is ON.. Close the door and verify if close limit switch is activated and if the close LED is ON.. Set select switch on C = MdStP.. Press Open button. While door is moving press Stop button at desired (mid-stop) position. 5. Set select switch on run mode (0,,, or 5). Mid-Stop Deactivation. Verify if the close limit switch is activated and if the close LED is ON.. Set select switch on C = MdStP.. Press the Stop, Close and Open buttons consecutively.. Set select switch on run mode (0,,,, or 5). Mid-Stop Timer (MD TM) This feature allows the Timer to Close to be enabled/disabled at the Mid-Stop position. MD TM Activation Select Switch. Verify if close limit switch is activated and if the close LED is ON.. Set select switch on 6 = Md Tm.. Press Close button.. Set select switch on run mode (, or 5). MD TM Deactivation. Verify if the close limit switch is activated and if the close LED is ON.. Set select switch on 6 = Md Tm.. Press the Stop button.. Set select switch on run mode (0,,,, or 5). Single-Button Control (SBC) With this feature, it is possible to use a single-channel transmitter for a Commercial Application, as well as a SingleButton Control (SBC). The SBC provides the user with the possibility to open, stop or close the door by using a single-button radio transmitter (or a single push-button station). SBC Activation. Verify if close limit switch is activated and if the close LED is ON.. Set select switch on 9 = SBC.. Press Open button.. Set select switch on run mode (,, or 5). Select Switch SBC Deactivation. Verify if the close limit switch is activated and if the close LED is ON.. Set select switch on 9 = SBC.. Press the Stop button.. Set select switch on run mode (0,,,, or 5). Universal Auxiliary Output Module (8 = WLF) The universal auxiliary output module is sold separately. The module allows for the connection of external devices such as: red and green warning lights (custom sequences available, ask Manaras-Opera for details), air curtains, horns, locks, etc... Call your dealer or Manaras-Opera for further information. Please contact your dealer or our inside sales department at -800-6-60 for further information. For technical support, please call -800-6-60 or visit www.manaras.com for more information

0 User Instructions IMPORTANT SAFETY INSTRUCTIONS WARNING TO REDUCE THE RISK OF SEVERE INJURY OR DEATH TO PERSONS:. READ AND FOLLOW ALL INSTRUCTIONS.. Never let children operate or play with door controls. Keep the remote control (where provided) away from children.. Personnel should keep away from a door in motion and keep the moving door in sight until it is completely closed or opened. NO ONE SHOULD CROSS THE PATH OF A MOVING DOOR.. Test the door's safety features at least once a month. After adjusting either the force or the limit of travel, retest the door operator's safety features. Failure to adjust the operator properly may cause severe injury or death. 5. For products having a manual release, if possible, use the manual release only when the door is closed. Use caution when using this release with the door open. Weak or broken springs may cause the door to fall rapidly, causing severe injury or death. 6. KEEP DOORS PROPERLY OPERATING AND BALANCED. See Door Manufacturer s Owner Manual. An improperly operating or balanced door could cause severe injury or death. Have trained door systems technician make repairs to cables, spring assemblies and other hardware. 7. SAVE THESE INSTRUCTIONS. IMPORTANT For more information or for immediate assistance, please contact your local dealer. NOTICE The installer should perform a demonstration of the operator and it's accessories (ex: push-button station, radio control), external entrapment protection device and manual release for the end-user. For instructions regarding the Hoist, Disconnect Mechanism and Emergency Egress, refer to the Installation Instructions found in section 6., p.. For technical support, please call -800-6-60 or visit www.manaras.com for more information

Quick Fix Instructions Table 9 - Basic Troubleshooting Guide ~ from floor level Symptom Door doesn't respond to any command Possible Cause Chain hoist is in engaged position, if applicable. (LED D9 is OFF) Return the chain to its neutral position (electrical mode). Refer to p. for further details. Disconnect chain is in engaged position, if applicable. (LED D9 is OFF) Release tension from the disconnect chain and secure the chain keeper. Refer to p. for further details. Stop button is stuck. (LED D9 is OFF) Press and release the Stop button on the wall station several times. No power supply. (LED D is OFF) Verify the incoming power line from the main breaker, making sure it has not tripped or blown a fuse. Photo cells are not properly aligned or are Door doesn't not obstructed. respond to Close or Loop is obstructed (presence of metal). radio commands (LED D0 is ON) When pressing Open Mechanical door lock is engaged. button, door opens Verify if the rubber seal at the bottom of the ~- ft, then stops and door is frozen to the ground (winter time). reverses Door doesn't respond to any radio command Clear the obstruction or re-align photo cells. Clear the obstruction. Release the door lock. Clear ice and free the rubber seal at the bottom of the door. No power supply. (transmitter light is OFF) Replace transmitter's battery. Poor radio control range. Bring the radio transmitter closer to the operator. Photo cells are not properly aligned or are obstructed. Clear the obstruction or re-align photo cells. Timer to Close has been suspended Timer to Close doesn't accidentally for ONE cycle. close the door Timer to Close closes the door after being suspended Fix Problem Timer to Close has been reactivated accidentally. Timer to Close will return to normal after the door has been fully closed. Refer to p.8 for further details. To suspend the Timer to Close, close the door completely. Then press the Stop button times and then press the Close button times. Refer to p.8 for further details. For technical support, please call -800-6-60 or visit www.manaras.com for more information

Maintenance Instructions IMPORTANT SAFETY INSTRUCTIONS WARNING TO REDUCE THE RISK OF SEVERE INJURY OR DEATH TO PERSONS: Inspections, service and repairs should be performed anytime a malfunction is observed or suspected. Only qualified persons should perform maintenance on a door operator and all safety precautions should be taken into consideration. When servicing, always disconnect operator from main power supply. KEEP DOORS PROPERLY OPERATED AND BALANCED. See Door Manufacturer s Owner Manual. An improperly operated or balanced door can cause severe injury or death. Have qualified door system technicians perform repairs to cables, spring assemblies and other hardware. Preventative Maintenance Schedule. Mechanical Inspection The door area should always be kept clear of dirt, rocks or any other substances in order to insure proper operation. Maintenance of the door operator should be performed according to the schedule in Table 0 and Table. Table 0 - Mechanical Inspection Schedule (Part ) Time Frame Inspection Test the door s safety features. Every Month Verify the brake function (if applicable). After adjusting either the clutch or the limit's travel, retest the operator s safety features. Verify gear reducer's oil level (if applicable). Every Months Verify and adjust the clutch if necessary. Lubricate all moving parts. Bushings are oil impregnated and are lubricated for life. Every 6 Months Verify that all mechanical parts function properly. Inspect the V-belt and adjust or replace if necessary. Manually operate the door. If the door does not open or close freely, correct the cause of the malfunction. For technical support, please call -800-6-60 or visit www.manaras.com for more information

Table - Mechanical Inspection Schedule (Part ) Time Frame Inspection Run the operator a few cycles: Make sure that the door rollers are rolling smoothly on the track. Listen to the motor: The motor should hum quietly and smoothly. Once a Year Verify that the limits operate quietly and smoothly: investigate any unusual noise. Verify that the mounting bolts are holding the unit securely. Inspect the unit for evidence of corrosion. Change the gear reducer's oil, at the very least, after every 500 hours of operation or once a year (if applicable).. Electrical Inspection It is recommended that the electrical maintenance inspections, be performed at the same intervals as the mechanical maintenance inspections. Table - Electrical Inspection Time Frame Inspection Inspect the unit for evidence of corrosion on electrical wires and connectors. Inspect the wiring compartment and remove any dirt from the control units. Verify all the grounding wires and terminals for corrosion. Be particularly careful to verify the ground wires. Verify the terminal strip to insure that all the screws are tightened. Every Month Verify that the pneumatic edge or other entrapment protection devices installed on the operator are fully operational. Verify the voltage at the input terminals while the operator is running. The voltage must not drop more than 0% momentarily. If the voltage drop is too deep when running, the relays may chatter and the contact points will wear prematurely and may eventually seize. Verify the power terminals for corrosion. Verify the current consumption of the unit with an amp-meter. The value of current should be consistent with the nameplate specifications. Investigate any anomaly. For technical support, please call -800-6-60 or visit www.manaras.com for more information

. Band Brake Maintenance WARNING To reduce the risk of SEVERE INJURY or DEATH to persons: Be sure that the main power is OFF before performing any changes on the operator... Changing a Brake Band The brake band is preformed at the factory. Please insert the brake band carefully around the brake drum. Remove solenoid cover Remove link and used band brake Link Push to remove Band Brake Solenoid Cover Replace band brake Place the link Be sure that the link is securely fastened on the tw o pins. Push solenoid plunger to reduce tension w hen removing or installing the band brake. 5 See brake adjustment on next page For technical support, please call -800-6-60 or visit www.manaras.com for more information

5.. Brake Adjustment The brake is factory set, however, after extensive use the brake may need to be adjusted. Remove solenoid cover Loosen pivot nut Pivot Nut Brake Drum Solenoid Cover Adjust solenoid gap Lever Gap must be betw een /''and /8''. Pull the lever to adjust the gap betw een the plunger and solenoid body. Tighten pivot nut 5 Check brake adjustment Recheck the gap measurement. Manually push the plunger onto the solenoid body, and verify that the brake drum rotates easily by hand. Plunger 6 Re-install solenoid cover For technical support, please call -800-6-60 or visit www.manaras.com for more information

6 Troubleshooting Guide The electronic control board LEDs help with wiring and troubleshooting diagnostics. Every LED indicates the status of the door. The electronic control board has a non-volatile memory and the LEDs return to their initial state after a power interruption. Easy Fix: Before starting any intervention, verify the LED's monitoring status and refer to Table 7, p.5 for a proper diagnosis. Table - Troubleshooting Guide - Part Symptom Door doesn't respond to any command Probable Cause Chain hoist is in engaged position, if applicable. (LED D9 is OFF) Return the chain to its neutral position (electrical mode). Refer to p. for further details. Disconnect chain is in engaged position, if applicable. (LED D9 is OFF) Release tension from the disconnect chain and secure the chain keeper. Refer to p. for further details. Stop button is stuck. (LED D9 is OFF) Press and release any Stop button. Control station is not connected or is wired incorrectly. (LED D9 is OFF) Verify and correct wiring. No power supply. (LED D is OFF) Verify the incoming power line from the main breaker, making sure it has not tripped or blown a fuse. Operator is not Selector switch is not set on the desired operating as expected mode. Timer to Close doesn't close the door Suggested Action Set switch on desired mode, refer to p.7 for further details. Timer to Close has been suspended accidentally for ONE cycle. Timer to Close will return to normal after the door has been fully closed. Refer to p.8 for further details. No power supply. (Transmitter light is OFF) Replace the transmitter's battery. Door doesn't respond to Transmitter is not properly programmed. any radio command Photo cells are not properly aligned or are obstructed. Reprogram the transmitter. Clear the obstruction or re-align photo cells. Door doesn't respond to Open command, but does respond to Close command Defective Open push-button or Open limit switch. Replace push-button or limit switch. Loose wire on Open push-button or Open limit switch. Verify and correct wiring. Door doesn't respond to Close command, but does respond to Open command Defective Close push-button or Close limit switch. Replace push-button or limit switch. Loose wire on Close push-button or Close limit switch. Verify and correct wiring. For technical support, please call -800-6-60 or visit www.manaras.com for more information