Abstract. Keywords. Pankaj Govind Hiray 1, B. E. Kushare 2

Similar documents
Battery-Ultracapacitor based Hybrid Energy System for Standalone power supply and Hybrid Electric Vehicles - Part I: Simulation and Economic Analysis

Development and Analysis of Bidirectional Converter for Electric Vehicle Application

Simulation of Fully-Directional Universal DC- DC Converter for Electric Vehicle Applications

An Improved Powertrain Topology for Fuel Cell-Battery-Ultracapacitor Vehicles

International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering. (An ISO 3297: 2007 Certified Organization)

A Bidirectional DC-DC Battery Interface for EV Charger with G2V and V2X Capability

EFFICIENT GRID CONNECTED INVERTER TO OVERCOME THE LOAD DISTURBANCE IN HYBRID ENERGY STORAGE SYSTEM

Energy Management Strategy Based on Frequency- Varying Filter for the Battery Supercapacitor Hybrid System of Electric Vehicles

Implementation Soft Switching Bidirectional DC- DC Converter For Stand Alone Photovoltaic Power Generation System

Design of Three Input Buck-Boost DC-DC Converter with Constant input voltage and Variable duty ratio using MATLAB/Simulink

EMS of Electric Vehicles using LQG Optimal Control

A Novel DC-DC Converter Based Integration of Renewable Energy Sources for Residential Micro Grid Applications

A Bidirectional Universal Dc/Dc Converter Topology for Electric Vehicle Applicationsand Photovoltaic Applications

Isolated Bidirectional DC DC Converter for SuperCapacitor Applications

Simulation Modeling and Control of Hybrid Ac/Dc Microgrid

Abstract- In order to increase energy independency and decrease harmful vehicle emissions, plug-in hybrid electric vehicles

INVESTIGATION AND PERFORMANCE ANALYSIS OF MULTI INPUT CONVERTER FOR THREE PHASE NON CONVENTIONAL ENERGY SOURCES FOR A THREE PHASE INDUCTION MOTOR

Dual power flow Interface for EV, HEV, and PHEV Applications

Analysis of a Hybrid Energy Storage System Composed from Battery and Ultra-capacitor

FAULT ANALYSIS OF AN ISLANDED MICRO-GRID WITH DOUBLY FED INDUCTION GENERATOR BASED WIND TURBINE

NOVEL MODULAR MULTIPLE-INPUT BIDIRECTIONAL DC DC POWER CONVERTER (MIPC) FOR HEV/FCV APPLICATION

Control System for a Diesel Generator and UPS

Performance Analysis of Bidirectional DC-DC Converter for Electric Vehicle Application

Battery Energy Storage System addressing the Power Quality Issue in Grid Connected Wind Energy Conversion System 9/15/2017 1

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM

Co-Ordination Control and Analysis of Wind/Fuel Cell based Hybrid Micro-Grid using MATLAB/Simulink in Grid Connected Mode

Implementation of Bidirectional DC/AC and DC/DC Converters for Automotive Applications

Research on PV and battery control system with energy management technology in stand-alone DC micro grid

Modelling and Control of Ultracapacitor based Bidirectional DC-DC converter systems PhD Scholar : Saichand K

Research on Electric Drive for Small Vehicles

Real-Time Simulation of A Modular Multilevel Converter Based Hybrid Energy Storage System

A New Control Algorithm for Doubly Fed Induction Motor with Inverters Supplied by a PV and Battery Operating in Constant Torque Region

Research and Design for a New Storage Type Converter

BIDIRECTIONAL DC-DC CONVERTER FOR INTEGRATION OF BATTERY ENERGY STORAGE SYSTEM WITH DC GRID

Modelling, Measurement and Control A Vol. 91, No. 1, March, 2018, pp Journal homepage:

Intelligent UPS System for Smart Grid to Achieve the Sustainable Energy

INTELLIGENT DC MICROGRID WITH SMART GRID COMMUNICATIONS: CONTROL STRATEGY CONSIDERATION AND DESIGN

OUTLINE INTRODUCTION SYSTEM CONFIGURATION AND OPERATIONAL MODES ENERGY MANAGEMENT ALGORITHM CONTROL ALGORITHMS SYSTEM OPERATION WITH VARYING LOAD

ENHANCEMENT OF ROTOR ANGLE STABILITY OF POWER SYSTEM BY CONTROLLING RSC OF DFIG

Supercapacitor Based Power Conditioning System for Power Quality Improvement in Industries

POWER ELECTRONICS & DRIVES

INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET)

Dynamic Modeling and Simulation of a Series Motor Driven Battery Electric Vehicle Integrated With an Ultra Capacitor

Bidirectional Intelligent Semiconductor Transformer

Implementation of Bidirectional DC-DC converter for Power Management in Hybrid Energy Sources

Design and Control of Hybrid Power System for Stand-Alone Applications

Operation and Control of Bidirectional DC-DC converter for HEV

Sustainable Energy Mod.1: Fuel Cells & Distributed Generation Systems

Power Quality and Power Interruption Enhancement by Universal Power Quality Conditioning System with Storage Device

Design of Four Input Buck-Boost DC-DC Converter for Renewable Energy Application

Fuzzy based STATCOM Controller for Grid connected wind Farms with Fixed Speed Induction Generators

International Journal of Advance Research in Engineering, Science & Technology

Simulation of real and reactive power flow Assessment with UPFC connected to a Single/double transmission line

POWER QUALITY IMPROVEMENT BASED UPQC FOR WIND POWER GENERATION

Synthetically Control of a Hybrid PV/FC/SC Power System for Stand-Alone Applications

Isolated Bidirectional DC DC Converter for SuperCapacitor Applications

Fuzzy Logic Control Based MIMO DC-DC Boost Converter for Electric Vehicle Application Ans Jose 1 Absal Nabi 2 Jubin Eldho Paul 3

MATLAB Simulation for Combination of Battery and Supercapacitor

Control Scheme for Grid Connected WECS Using SEIG

Power Management with Solar PV in Grid-connected and Stand-alone Modes

Reactive power support of smart distribution grids using optimal management of charging parking of PHEV

Control System and Performance of DC Micro grid under Various Loads

Implementation of FC-TCR for Reactive Power Control

Voltage Sag Mitigation in IEEE 6 Bus System by using STATCOM and UPFC

IMPROVEMENT OF POWER QUALITY OF AC MICROGRID WITH ENERGY SYSTEM USING BY ELECTRIC DOUBLE LAYER CAPACITOR

Power Electronics Projects

Power Conditioning of Microgrids and Co-Generation Systems

A Study of Electric Power Distribution Architectures in Shipboard Power Systems

APPLICATION OF BOOST INVERTER FOR GRID CONNECTED FUEL CELL BASED POWER GENERATION

Journal of American Science 2015;11(11) Integration of wind Power Plant on Electrical grid based on PSS/E

Technology from the New Product SANUPS K for a Smart Grid Society

Behaviour of battery energy storage system with PV

Review of Ultracapacitor Technology and its Applications

Power Balancing Under Transient and Steady State with SMES and PHEV Control

CONTROL AND PERFORMANCE OF A DOUBLY-FED INDUCTION MACHINE FOR WIND TURBINE SYSTEMS

International Conference on Advances in Energy and Environmental Science (ICAEES 2015)

Study of DFIG based Wind Turbine for Reactive Power Generation Capability

Control of PV-FC-Battery-SC Hybrid System for Standalone DC load

A Parallel Energy-Sharing Control for Fuel cell Battery-Ultracapacitor Hybrid Vehicle

COMPARISON OF PID AND FUZZY CONTROLLED DUAL INVERTER-BASED SUPER CAPACITOR FOR WIND ENERGY CONVERSION SYSTEMS

STUDY ON MAXIMUM POWER EXTRACTION CONTROL FOR PMSG BASED WIND ENERGY CONVERSION SYSTEM

Unified Power Quality Conditioner with Electric Double Layer Capacitor

Design and Simulation of a Solar Based DC-DC Converter for Hybrid Electric Vehicles

Design of High Performance and High Efficiency DC-DC Converter for Hybrid Electric Vehicles

Hybrid Energy Storage System Controller for Electric Vehicle using Ultracapacitor: Modeling and Performance Analysis

DC-DC BIDIRECTIONAL ISOLATED CONVERTER FOR FUEL CELLS AND SUPER-CAPACITORS HYBRID SYSTEM

6545(Print), ISSN (Online) Volume 4, Issue 2, March April (2013), IAEME & TECHNOLOGY (IJEET)

Ahmet Aktas, Koray Erhan, Engin Ozdemir, Sule Ozdemir. University of Kocaeli, Kocaeli

IJSER. 1. Introduction. 2. Power flow of Doubly fed Induction Generator (DFIG) K. Srinivasa Rao 1 G. Kamalaker 2

Modeling and Simulation of Firing Circuit using Cosine Control System

INSTALLATION OF CAPACITOR BANK IN 132/11 KV SUBSTATION FOR PARING DOWN OF LOAD CURRENT

ELECTRICAL POWER SYSTEMS 2016 PROJECTS

Integration of Photovoltaic-Fuel Cell Scheme for Energy Supply in Remote Areas

Design and Implementation of Reactive Power with Multi Mode Control for Solar Photovoltaic Inverter in Low Voltage Distribution System

Design and Simulation of Grid Connected PV System

DC Microgrids and Distribution Systems for Residences

Integration of Ultra Capacitor with Battery using DC-DC Bidirectional Buck Boost Converter in an Electric Vehicle.

A.Arun 1, M.Porkodi 2 1 PG student, 2 Associate Professor. Department of Electrical Engineering, Sona College of Technology, Salem, India

A ZVS Interleaved Boost AC/DC Converter Using Super Capacitor Power for Hybrid Electrical Vehicles

Modeling Comparision Of Solar Pv/ Fuelcell/Ultra Capacitor Hyrbrid System For Standalone And Grid Connected Application

Transcription:

Controller Design for Supercapacitor as Energy Storage in Medium Voltage AC System Pankaj Govind Hiray 1, B. E. Kushare Abstract This paper analyzes the supercapacitor based voltage support system for medium voltage AC system. For the last decade supercapacitors have become an integral part of low voltage power electronic systems where high power density from dc storage device is required frequently. So far their use has been limited to delivering or absorbing pulses of power during transient operation, such as starting up of an electrical motor, storing regenerated energy or supplying instant power in low voltage range within small scale distributed generation system. Not much work has been done in investigating performance of supercapacitor storage in medium voltage ac systems subject to extreme conditions such as sudden load demand in the MW range or network faults. The power source has been designed to ride through seconds voltage sag caused either by high load demand or remote system fault. This paper attempts to investigate how efficiently supercapacitor storage can be utilized to meet the power demand in ac grid. Keywords Supercapacitor, Energy Storage, Voltage Source Converter, DC-DC converter. 1. Introduction In distributed generation system the performance of instantaneous energy sources plays a significant role to balance active power mismatch. In this regard Supercapacitors have been popular candidates for meeting the need for sudden power demand due to their very high efficiency of around 95% [1]. From last some years Supercapacitors have become an integral part of low voltage power electronic systems where high power density from dc storage device is required frequently. Pankaj Govind Hiray 1, Student of Electrical Engg. Dept., K.K.Wagh Institute of Engg. Edu. & Research, Nashik, India. B. E. Kushare, Head of Electrical Engg, Dept., K.K.Wagh Institute of Engg. Edu. & Research, Nashik, India. So far their use has been limited to delivering or absorbing pulses of power during transient operation, such as starting up of an electrical motor, storing regenerated energy or supplying instant power in low voltage range within small scale distributed generation system []. Voltage sags have been found especially troublesome because they are random events lasting only a few cycles. The process equipment may not keep continuing its normal operation during these sags for many cycles and will trip or shut down, although the supply voltage is totally recovered a few cycles after the sag occurrence. Therefore, from the point of view of industrial customers, voltage sags and momentary interruptions might produce the same effect to their processes [3]. Not much work has been done in investigating performance of supercapacitor storage in medium voltage (10-40KV) ac systems subject to extreme conditions such as sudden load demand in the MW range or network faults [4]. This paper attempts to investigate how efficiently supercapacitor storage can be utilized to meet the power demand in ac grid, while also ensuring appropriate control during grid fault conditions. Many surveys regarding power quality problems related to voltage sags and momentary interruptions have been presented. They are usually useful for determining the solution required for tackling the existing problem at a certain industrial facility, with special emphasis on the rating and ride-through capability of proposed mitigation equipment. These surveys agree usually in at least one point, faults on overhead transmission lines contribute to the great majority of voltage sags verified in the distribution network and these sags are the most critical power quality problem to industrial customers. Prior works have incorporated super capacitor storage with different energy sources in a common dc bus and their focus is to manage the power flow to and from the dc bus or the condition of multiple sources like batteries, photovoltaic, wind, gas cogeneration and flywheels [5]. Some discussed multiple modes of operation like power dispatch, voltage regulation and control of power flow to and from different sources and loads in small scale dc or ac distributed network, also some proposed a fault protection scheme applicable to a dc bus serving variety of loads and 110

) Energy discharge mode: - Supercapacitor energy storage delivers energy to the grid to compensate the voltage sag due to a high load demand that exceeds the capacity of the main generator. 3) Charging mode: - Supercapacitors charge up during this mode if there is excess energy available in the grid due to a low load demand. generators using modern voltage source converters as current limiting circuit breakers [6, 7]. Their method of fault interruption and isolation is based upon predefined protection zones that are not device based but by embedded circuit breakers within the voltage source converters. Their energy sources were local generators and no dc storage capable of providing instantaneous power was considered. The work discussed focused on power balancing and control of energy flow among multiple energy sources. As Supercapacitors are capable of providing a huge amount of power within a very short time, it is possible for them to discharge a large energy into a fault before circuit breaker can open. Hence uncontrolled support of the grid can be dangerous. On the other hand it is still necessary to ensure sufficiently fast release of power during sudden increase of load demand. There is very little research in this area where an intelligent controller on the dc side can determine whether or not to support a sagging voltage in the grid (depending on cause load or fault), and how much energy to deliver at any instant [8]. This paper begins to address some of the following important issues: Design and develop a controller intelligent enough to maintain continuity of power to loads. Manage fault in low and medium voltage system. To intelligently manage the supply of energy to loads and maintain stability using ramprate limits. Figure1: System configuration Supercapacitor energy storage design Figure describes the simple model of supercapacitor storage used. Figure : Model of supercapacitor storage. System configuration Figure 1 shows the configuration of the reference system, which is also a typical configuration of energy storage for grid support and peak power shaving. A 13.8KV grid is fed by a 4KV, 5MVA steam driven main generator (G). A supercapacitor storage and DC-DC chopper represents the alternate energy storage system coupled with the grid through 0.77KV/13.8KV step up transformer. No long term backup energy storage has been considered, the power source has been designed to ride through seconds voltage sag. Three modes of operation have been considered: 1) Normal operating mode: - In this mode there is no real power exchange between the supercapacitor and the grid as the main generator can deliver all of the required power. The storage is sized to support a 1MW load for seconds, which is sufficient for a system with similar rating and applications in peak power shaving and absorbing excess power. The total supercapacitor stack voltage is taken to be V 0 =500V and the minimum allowable voltage of the storage is V 1 = 400V, considering the combined efficiency (81%) of the DC-DC chopper and the inverter [4]. Total Energy required, 6 (1 10 ) E 0.81 3600 = 685.87W-h =.47MJ Total capacitance required (C) is calculated from the energy equation: 1 E C( V 0 V1 )..... (1) 111

6 1.47 10 C (500 400 ) C= 54.86F But due to the limited current capability this storage has been oversized with the number of parallel strings of modules N p =16, and modules in series N s =11.This provides a total capacitance of 40F and a total effective series resistance of 0.00488OHM. Energy Storage and inverter control The basic control strategy is described in figure 3. The inverter and the DC-DC converter topology is chosen as such since it is the most popular and cost effective configuration when dealing with ac/dc power quality improvement converters. The PWM control of the voltage source converter and voltage control of the dc link is used due to its simplicity and successful application in similar systems. The bidirectional chopper controls the power flow between the supercapacitor and the grid. The approach followed in this work was to develop an appropriate control of DC link voltage (V dc ) separately using the inverter control block to minimize the interaction between the control of the DC-DC chopper and the inverter that would work as a voltage source inverter only during normal operating mode. The grid voltage used as the input signal for the inverter control is calculated as follows: V G a 1/ 3( V V V )... () b C Supercapacitor charge/discharge control uses the demanded power (P) at the grid to control the power flow to and from the supercapacitor the input signal V dc is only used to ensure that the control for voltage source inverter is working properly and is able to control V dc at the required level. work, the amplitude modulation index of the sinusoidal reference signal is chosen 1.0. The modulated sinusoidal reference signal is compared with the triangular carrier signal in order to generate the gate signals for the IGBT s. The frequency of the triangular carrier signal is chosen 450 Hz. The DC voltage across the capacitor is 1000 Volt, which is kept constant throughout by the 6-pulse PWM converter. The supercapacitor is charged or discharged by adjusting the average (i.e., DC) voltage across the coil to be positive or negative values by means of the DC-DC chopper duty cycle D, controlled by a conventional PI controller as shown in Figure 3, where ΔP indicates the real power deviation of grid. When the duty cycle is larger than 0.5 or less than 0.5, the supercapacitor is either charging or discharging respectively. When the unit is on standby, the supercapacitor current is kept constant, independent of the storage level, by adjusting the chopper duty cycle to 50%, resulting in the net voltage across the supercapacitor to be zero. In order to generate the gate signals for the IGBT s of the chopper, the PWM reference signal is compared with the saw tooth carrier signal. The frequency of the saw tooth carrier signal for the chopper is chosen 100 Hz. Voltage source converter control Voltage source inverter is the interface between the grid and the supercapacitor energy storage unit. The reference signal for the PWM control for the voltage source inverter is phase modulated by means of the phase angle, α described in figure 4. Figure 3: Energy storage and Inverter control The pulse width modulation (PWM) voltage source converter (VSC) provides a power electronic interface between AC power system and supercapacitor. In the PWM generator, the sinusoidal reference signal is phase modulated by means of the phase angle, α, of the VSC output ac voltage. In this Figure 4: Control for voltage source inverter.4 DC-DC Chopper control Figure 5 shows the control strategy for the DC-DC converter. DC-DC converter works as a simple buckboost converter with P_grid as the main driving control signal obtained from calculating the three 11

phase power in the grid. There is a window for the Compared the actual output voltage with the controller (3.8MW to 4.1MW) within which is command voltage signal, then put the error goes operates in the normal operating mode. So the through PI regulator to get the DC current signal i d. converter will operate in energy discharge mode Compared i d with the actual input current, and put the when P_grid > 4.1MW and will operate in charging error goes through PI regulator. Then put the output mode if P_grid < 3.8MW. go through the triangle-wave comparator to generate PWM waveform to control the switching device S. By doing so, the actual input current will track the command current to control the output voltage. The control process is shown in Figure 7. Figure 7: Block diagram of discharging control 3. Performance analysis Figure 5: Control for DC-DC converter The process of constant voltage charging control The triangular wave comparison method is used in the constant voltage charging mode, through the realization of double-loop control. The outer ring is the output DC voltage control, and the inner loop is the output DC current control. The output of the PI regulator in the outer loop is the DC current signal i d. After the comparison between i d and the actual DC output current signal, the error current is amplifies through the PI regulator. Then take the amplified error comparing with the actual DC output voltage, and the new error will go through the triangle-wave comparator to generate PWM waveform to control the switching device S. By doing so, the actual voltage will track the command voltage as shown in Figure 6. Supercapacitor voltage, grid voltage, grid power and dc link voltage observed for analysis of system performance in sudden load increase. The simulation is carried out in Matlab Simulink. At 1.8 seconds line load increased from 4.0MW to 4.7MW and continued till 3.8 seconds, in this period the converter operated in energy discharge mode and supplied excess energy from supercapacitor, in this period the grid voltage and power is observed in Figure 8, at same time supercapacitor started discharging and its voltage is observed in figure 9. Figure 8: Energy discharged from supercapacitor. Figure 6: Block diagram of constant current charging mode The process of discharging control The direct current control is used in the discharging control, through the realization of double-loop control. The outer ring is the output voltage control, and the inner loop is the input current control. 113 Figure 9: Supercapacitor voltage.

In load demand increased period the boost converter operated, the IGBT firing pulses observed in Figure 10. In that period dc link voltage observed steady in figure 11. Figure 10: Buck-Boost converter firing pulses in energy discharge mode Figure 11: DC link voltage. 4. Conclusion and Future Work In energy discharge operating mode the grid voltage maintains its desired value with negligible fluctuations also supercapacitor fed extra energy demand of grid for seconds without disturbing dc link voltage. The grid voltage waveform is also clean with very little distortion. Until now the basic operation and control for supercapacitor based energy storage has been developed in the medium voltage system. Further Work being done to study the effects of a fault and develop the controls for efficient management of power between the loads even during a fault condition and maximum utilization of resources and robustness in the stability of grid voltage. Acknowledgment The authors would like to thank the K. K. Wagh Institute of Engineering Education And Research for providing resources and guide to present this paper. References [1] Phatipat Thounthong, Viboon Chunkag, Panarit Sethakul, Bernard Davat, Melika Hinaje, Comparative study of fuel cell vehicle hybridization with battery or supercapacitor storage device, IEEE transactions on vehicular technology, vol.58, pp389-3904, October 009. [] Lijun Gao, Roger A. Dougal and Shengyi Liu, Power enhancement of and actively controlled battery/ultracapacitor hybrid, IEEE Transaction on Power Electronics, vol.0, pp 36-43, January-005. [3] Alfred Rufer, David Hotellier and Phillippe Barrade, A supercapacitor based energy storage substation for voltage compensation in weak transportation networks, IEEE Transaction on Power delivery, vol.19, pp 69-636, April-004. [4] Asif Anwar, Mohd. Hasan Ali and Roger A. Dougal, Supercapacitor Energy storage device for low voltage ride through in a 13.8 KV AC system, IEEE Transactions on Power Electronics, Nov.009. [5] J. Baunman, M. Kazerani, A comparative study of fuel cell battery, fuel-cell ultracapacitor and fuel-cell battery ultracapacitor vehicles, IEEE Transaction on Vehicular Technology, vol.185, pp 1533-1543, December 008. [6] PJ Binduhewa, AC Renfrew and M. Barnes, Ultracapacitor energy storage for microgrid micro-generation, Power Electronics, Machines and Drives Conference, York, pp 70-74, -4 th April 008. [7] Freek Balbergen, Pavol Bauer and Jan Abraham Ferreira, Energy storage and power management for 4-Q load, IEEE Transaction on Power Electronics, Vol.56, pp. 1484-1498, May 009. [8] [M. B. Camara, H. Gualous, F. Gustin, and A. Berthon, Design and new control of DC/DC converters to share energy between supercapacitors and batteries in hybrid vehicles, IEEE Trans. Veh. Technol., vol. 57, no. 5, pp. 71 735, Sep. 008. [9] P. Thounthong, S. Raël, and B. Davat, Control strategy of fuel cell and supercapacitors association for distributed generation system, IEEE Trans. Ind. Electron., vol. 54, no. 6, pp. 35 333, Dec. 007. Pankaj Govind Hiray received B.E. degree in Electrical Engineering from the University of Pune, India. Currently he is student of M.E. Control System; his working interests include design of controller for supercapacitor as energy storage for medium voltage AC system, modeling and simulation. 114