Buck BioAire Model B520 Instruction Manual

Similar documents
Buck BioSlide Model B1020 Instruction Manual

Bio-Pump Plus. Operating Instructions. Product # ZBP-200. Description. Specifications

Models DP10 & DP20 Series Low Voltage Disconnects User s Manual Rev. 1.1 October 31, 2007

Indoor Air Quality Meter

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

IAQ-CALC TM Indoor Air Quality Meter

IAQ-CALC TM Indoor Air Quality Meter

Attitude Instructions Ford 6.0 Powerstroke

Ventilation Testing. Micromanometer. Alnor Model AXD610 AIRFLOW TM Model PVM610. Operation and Service Manual

RCL-7A. User s Guide. Battery Charging Station. Technology in Depth

Thermaltake Warranty / Support Information

PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.

EAGL 1-Touch Laser Level

Rotating Vane Anemometer

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.

Medi-Flow. Model M101 & M101D Medicator Instructions GETTING TECHNICAL ASSISTANCE

CRD610 Automatic Fitting Inserter

SETRA Operating Instructions Series DPT 230 Pressure Transducers

AIR VELOCITY METER ALNOR MODEL AVM410 AIRFLOW INSTRUMENTS MODEL TA410

IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase.

18VDC ESB6 Series Cordless Screwdrivers Operation Manual

INSTRUCTION MANUAL SURFACE RESISTIVITY METER SRM-110

UniTorq UTQ Quarter-Turn Actuator Installation and Operation Manual

MICROMANOMETER ALNOR MODEL AXD610 AIRFLOW INSTRUMENTS MODEL PVM610

ST-70 CONTROL OPERATING MANUAL REVISION DATE: PART#:

VSS-1 VSS-5 VSS-12 VALIDATED SAMPLING SYSTEM INSTRUCTION MANUAL

BC-9000 OPERATIONS MANUAL BATTERY CHARGER COFKO ELECTRONICS LLC COPYRIGHT 2014 P/N

Owner s Guide. ca5354

Owner s Guide CA 4555

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Rotating Vane Anemometer

OWNER S MANUAL. Model 9880 Intrinsically Safe Air Velocity Meter

VANGUARD A EZ INSTALL OPERATOR S MANUAL

Flo-Way. Measure Granular or Powdered Material. Stand Alone or Connect to Other Devices for Blending. Used by Successful Producers World-Wide

Ratio Feeder DB & DD Series Injectors

SUBMERSIBLE SUMP PUMPS

CTFRP Series Power Supplies

AUTO-BLiP. User Manual Lotus INTELLIGENT DOWNSHIFTS. Version 1.0

Type Flexair Pneumatic Pressure Control Valves

V-DETECT UTILITY GRADE VOLTAGE DETECTOR

Quick Start Guide. AZ Mount Pro Level and Go Altazimuth Mount Models: #8900, #8920

TABLE OF CONTENTS NOTES. 1.0 Operating principle... 02

AUTO-BLiP. User Manual Porsche INTELLIGENT DOWNSHIFTS. Version 1.2

Owner s Guide CARS & CA4B5

Installation Power Management Unit Battery Cables and Battery Harness

PVI 60KW, PVI 82KW, PVI 95KW

Broadband PowerShield. CP27U Models. User Manual

AUTO-BLiP. User Manual Ford Mustang INTELLIGENT DOWNSHIFTS. Version 1.2

SB SWITCH CONTROL BOX

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

USER S GUIDE 2880 SERIES. 3 Safety Instructions. Product View. Assembly 4-5. Operation. Maintenance and Care. Troubleshooting.

MAINFRAME HOT RUNNER TEMPERATURE CONTROL SYSTEMS. Instruction Manual

ASM Maxi Poles. Instruction-Parts B Series. For the application of architectural paints and coatings.

AUTOMATIC SUBMERSIBLE UTILITY PUMP

INSTRUCTION MANUAL CAT Bio-Pump Plus

Owner s Guide. ca5154

User's Guide. EzFlex Thermo-Anemometer. Model EZ30 UNITS MAX MIN AVG VEL

Owner s Guide. ca6154

JUMP&GO. Portable Jump Start & Power Supply OWNER S MANUAL

VELOCICALC Air Velocity Meter

SPC Series. Digital Scale. Operation Manual

CRD600 Automatic Fitting Inserter

INSTALL GUIDE Dodge/RAM 5.7L HEMI

AXD 530 MicroManometer

Outdoor Nema Enclosure For Dotworkz CoolDome Power Supply Product Code: NM-CDPS. User Manual

BlinkerBeam Solar Controller

DP-CALC TM Micromanometer

CAUTION 7.0 WARRANTY CONTENTS. 1.0 Overview... 2

Exhaust Fan Flow Meter. Operation Manual. The ENERGY CONSERVATORY DIAGNOSTIC TOOLS TO MEASURE BUILDING PERFORMANCE

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL

4-SIDED BASKETBALL SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: PART#:

SUBMERSIBLE SUMP PUMPS

BRAVO Inverter/Battery Charger. Table of Contents

Level Alert Model Multi-Switch Liquid Level Sensor. Assembly and Installation Instructions

AUTO-BLiP. User Manual Chevrolet Corvette. Version 1.7

AUTO-BLiP. User Manual Chevrolet Corvette. Version 1.2

WJS-3500 User Guide MIGHTY JUMP STARTER. Portable Jump Start & Power Supply

TABLE OF CONTENTS 10.0 LIMITED WARRANTY

Series K Pneumatic Switch Mechanism

WJS-1800 User Guide MINI JUMP STARTER. Portable Jump Start & Power Supply

Instructions 3A4793B EN. See page 3 for a complete list of model descriptions and part numbers.

USER'S GUIDE 9151 SERIES V

Charging with AC (wall) Charger

User Guide IGD Series

7.3L POWERSTROKE BANJO BOLT KIT Fits L Powerstroke Diesel. Installation Guide

HSIV PLOW OPERATOR S MANUAL

ECLIPSE Laundry Dispenser Controller

Owner s Guide APS596Z

MoistureMatch A next generation grain tester

Electronic lube meter

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Updated: October 2012

Analog Durometer Model AD-100

"WHERE TUBING AND FITTINGS COME TOGETHER"

Owner s Guide CA 5055

Installation Guide Smart-UPS On-Line External Battery Pack XBP48RM1U-LI

CA 5054 Owner s Guide

SKY-WEIGH HELICOPTER CARGO HOOK LOAD MONITORING SYSTEM. User Guide Quality Industrial Weighing and Force Measurement Equipment

4-SIDED HOCKEY SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: PART#:

Transcription:

A.P. BUCK, INC. Buck BioAire Model B520 Instruction Manual A.P. BUCK, INC. 7101 Presidents Drive Suite 110 Orlando, FL 32809 USA Tel 1-800-330-2825 407-851-8602 Fax 407-851-8910 apbuck@apbuck.com www.apbuck.com A.P. BUCK, INC. MAN-BIOAIRE REV-D 12/19/2003 Manual Part No. APB-107034 5-20LPM Constant Flow Bioaerosol Sampling Pump Page Quick Guide 3 Product Description and Features 4 Additional Features and Specifications 5 Operating Instructions-BioAire Model B520 6 Timing Routines and Battery Charging 7 Parts & Accessories 8 Service Information and Technical Support 9 Warranty 10

NOTES:

WARRANTY The seller warrants to the Purchaser that any equipment manufactured by it and bearing its name plate to be free from defects in material or workmanship, under proper and normal use and service, as follows: if, at any time within 1 (one) year from the date of sale, the Purchaser notifies the Seller that in his opinion, the equipment is defective, and returns the equipment to the Seller's originating factory prepaid, and the Seller's inspection finds the equipment to be defective in material or workmanship, the Seller will promptly correct it by either, at its option, repairing any defective part or material or replacing it free of charge and return shipped lowest cost transportation prepaid (if Purchaser requests premium transportation, Purchaser will be billed for transportation costs). If inspection by the Seller does not disclose any defect in material or workmanship, the Seller's regular charges will apply. This warranty shall be effective only if installation and maintenance is in accordance with our instructions and written notice of a defect is given to the Seller within such period. This warranty is exclusive and is in lieu of any other warranties, written, oral or implied; specifically without limitation, there is no warranty of merchantability or fitness for any purpose. The liability of the Seller shall be limited to the repair or the replacement of materials or parts as above set forth. BioAire Quick Guide Bioaerosol Sampling Pump A.P. Buck, Inc. Power ON. Press Pre-Set Calibration Mode press (For Continuous sample time key once, use arrow Mode press key ) after power ON keys to adjust flow, for 4 seconds. press CAL key to set flow Power OFF Status LED s confirm Press key for 1 sec all pump functions. LIMITATION OF LIABILITY The seller shall not be liable for any claim for consequential loss or damage arising or alleged to have risen from any delay in delivery, malfunction or failure of the equipment. The Seller's liability for any other loss or damage arising out of or connected with the manufacture, sale or use of the equipment sold, including damage due to negligence, shall not in any event exceed the price of the equipment supplied by us. A.P. Buck, Inc. reserves the right to make changes at any time, without notice, in prices, colors, materials, specifications and models, and to discontinue models. Seller makes no warranty for merchantability of purpose. Copyright 2003 A.P. Buck, Inc. This operating manual and the data enclosed herein are not to be reproduced or used, in whole or in part, by anyone without written permission of A.P. Buck, Inc. Buck BioAire Model B520 Pump is shown with Buck BioAire cassette and APB-706100 Calibration Rotameter Assembly fitted. Adjust flowrate on key pad under CAL mode up or down until rotameter ball is centered on 15 LPM mark. All sample flow calibrations are performed with actual bioaerosol cassette in-line. Page 10 Page 3

Product Description The Buck BioAire Model B520 is a bioaerosol sampling pump designed to draw air into standard bioaerosol sampling cassettes, such as the Buck BioAire Cassette and the Air-O-Cell *. These impaction slit air samplers have little restriction to air flow and allow larger flow rates to be drawn through the cassette with little backpressure. A microprocessor controls the BioAire s flowrate and provides preset timing routines for sample collection. The pump is capable of flow rates from 5 to 20 Liters Per Minute (LPM). The flows are adjustable from the keypad in (CAL) Calibration Mode. The calibrated flow rate will be maintained at a constant flow throughout the collection period. Four timing routines are selectable from the keypad and continuous flow is achieved by pressing the ON key for 4 seconds. The OFF key manually stops the pump from sampling. The pump uses nickel cadmium (NiCad) rechargeable batteries and will operate up to five hours on a fully charged pack. The standard battery charger supplied with the pump charges the batteries in 6 hours. An optional FastOne (APB-601900) One Hour charger is available. A/C powered operation can be conducted with the supplied Standard Charger. Product Features 5-20LPM Adjustable Constant Flow Range 5 hours continuous operation at 15LPM with Buck BioAire or Air-O-Cell bioaerosol sampling cassettes Small and lightweight Battery powered, rechargeable with standard charger or optional FastOne One Hour charger. Tripod Mount on bottom of unit Convenient timers for 1, 2, 5, or 10 minute samples End-of-Sample audible and visual indicators Easy keypad calibration with supplied Calibration Rotameter and sampling media in-line for greatest accuracy Page 4 Service Information You must obtain an RMA number prior to returning any product. Obtain your RMA number by calling A.P. Buck, Inc. Customer Service at 1-800-330-BUCK or 407-851-8602. To expedite service and repairs, have your Customer ID handy and visit our website, www.apbuck.com, and request an RMA# online. Please ensure that all products returned to A.P. Buck, Inc. contain no hazardous materials. Any obviously contaminated product received will be returned to the customer. All products scheduled for service must be received within 30 days of the RMA number issuance date. Unauthorized products will be returned to the customer. For all work not covered under warranty, A.P. Buck, Inc. will repair any instrument for the cost of parts and labor as quoted. If major components must be replaced, A.P. Buck, Inc. will notify the customer before proceeding with repairs. When returning any instrument for service, please include a Purchase Order marked: Repair Cost Not To exceed $250.00 Without Customer Authorization. Please provide the following information with your instrument: Company Name: Address: Telephone: Fax: Contact Name: Serial Number(s): Date of Purchase: Service Required or Description of Problem: TECHNICAL SUPPORT SERVICES Technical Assistance: Phone (407) 851-8602 Fax: (407) 851-8910 Email: apbuck @apbuck.com Web site: www.apbuck.com Hours: Monday-Friday 8:00AM to 4:30 PM (EST) Page 9

Parts and Accessories BUCK BioAire Pump Model B520, (APB-706000) complete with standard 120VAC adapter/charger, instruction manual, and APB-706100 Calibration Rotameter Assembly BUCK BioAire Pump Model B520, (APB-706020) complete with standard 230VAC adapter/charger, instruction manual, and APB-706100 Calibration Rotameter Assembly Buck Standard Charger, (APB-603900) supplied, 120VAC Designed to charge the BioAire Pump Battery Pack (6 hours charge time) Buck Standard Charger, (APB-603910) supplied, 230VAC Designed to charge the BioAire Pump Battery Pack (6 hours charge time) BUCK FastOne Charger (APB-601900) optional, 90-240VAC Single Station Automatic One Hour Charger BUCK BioAire Rechargeable Battery Pack 4.8VDC (APB-108014) The pack of four cells can easily be changed by opening the case and lifting the pack off the Velcro strip, unplugging the connector and installing the new pack Vinyl Tubing (APB-109132) A ten foot section of 1/2 inch ID vinyl tubing for remote sample collection with Buck BioAire and Air-O-Cell cassettes Calibration Rotameter Assembly (APB-706100) fits on top of Bioaerosol cassette for convenient flowrate setting and pump calibration Tripod for BioAire support (APB-104102) supports BioAire for breathing zone and other elevated samples *Air-O-Cell is a trademark of Zefon International BioAire and FastOne are trademarks of A.P. Buck, Inc. Audible Alert ON/OFF The arrow keys will turn off the audible beep in areas where sound is not appropriate. With the pump power ON, press the Down Arrow Key for 4 (four) seconds or until two beeps acknowledge the disabling of the beeper. Press the Up Arrow Key for 4 (four) seconds or until three beeps signify the audible beeper is ON. Low Battery Warning When sampling pressing the down arrow key will light up the LED s, located on the right side of the unit, based on the battery charge. If all 5 LED light the batteries are 100%. If 4 light is 80%, 3 light = 60%, etc. The low battery LED will begin flashing when there is only enough power to collect a 10 minute sample. Sample Timing Lock-Out Once the Red low battery warning LED stops blinking and becomes Solid Red, none of the timing keys will function and a new sampling cannot be started. At this time the pump must be recharged or plugged into the charger to continue sampling. Tripod Mount A connector located on the bottom of the unit provides easy connection to most standard tripods. Model: Flow Range Accuracy Specifications BioAire Model B520 5 to 20LPM ± 5% at Set Point Run Time 5 hours @ 15LPM Size 4 H x 6 W x 5.25D (10.2 cm H x 15.2 cm W x 13.3 cm D) Weight 22oz (624 g) Battery Voltage Compatibility: Recharge Time Marks 4.8VDC (120 or 230VAC standard charger included) Buck BioAire or Air-O-Cell cassettes 6 hours (1 hour with optional FastOne 90-240VAC Charger) Page 8 Page 5

Operating Instructions Model B520 Sampling Setup 1. Fully charge the pump to be assured of the maximum sampling time. 2. Place a bioaerosol sample cassette firmly into the hose connection of the sampling head on the top of the unit. 3. Turn the pump on by pressing the ON key. At this moment the BioAiare pump will actuate all the indicating LED lights for one second and beep twice to acknowledge the turn on. This turn on process provides confirmation to the operator that the indicating lights and beeper are functioning properly and that the unit has adequate battery power to operate. Calibrate and Set Flow Rate 1. Place the Rotameter Calibrator on top of the cassette as shown. 2. The CAL key, when pressed, will turn on the pump motor to approximately 15LPM with the BioAire or Air-O-Cell Cassette installed 3. Use the Arrow Keys to move the flow rate up or down until the red ball of the Rotameter is centered at the 15LPM mark. The pump requires 10-15 seconds to stabilize after the arrow keys are pressed. 4. Once the flow is selected, press the CAL key to stop the pump and store in memory the flow rate selected. This will remain as the flow rate until the calibration is changed by pressing the CAL key and repeating Steps 1-4. The BioAire Model B520 is now ready to collect a sample. For greatest accuracy, calibrate with each use, or at least daily. The Rotameter Calibrator is a Secondary Flow Standard and can be used anytime to verify flow rate. or to check flow restriction of a bioaerosol cassette (flow restriction, or higher backpressure, will result in a lower flowrate reading on the Rotameter). Note: a dedicated calibration sampling cassette may be used for flow rate setting to avoid possible contamination to an actual sample. Sampling Timing Routines 1. Place the sampling cassette firmly into the sampling head of the BioAire pump. 2. Turn on the pump by pressing the ON Key (the green POWER LED is lighted). 3. Start the sampling by pressing one of the timing keys (1, 2, 5, or 10 minutes). LED will light. The BioAire will automatically run to the calibrated flow for the selected time. End of Sampling At the conclusion of the sampling, the pump will stop. The COMPLETE LED will light and the timer LED will be flashing to indicate which timing routine was selected. Auto Power Off for Battery Conservation The BioAire turns off 5 minutes after being turned ON if no keys have been pressed. The pump automatically turns off approximately 30 minutes after any sampling routine if no other key is pressed. Battery Charging Wall Charger (APB-603900) The standard wall charger supplied will charge the batteries in approximately 6 hours or run the pump when battery is low. FastOne Charger APB-601900 Optional. The FastOne Charger will charge the Pump s batteries in approximagely one hour. This charger uses a negative delta voltage technique which proveds a fully charged pack before going to a trickle mode. LED lights on the charger indicate the status of the charging. Page 6 Page 7