Start UP Guide. Symmetra LX Tower Rack-Mount. UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva

Similar documents
Electrical Installation

Safety and General Information

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Installation Guide Smart-UPS 1200/1500 VA 100/120/230 Vac Rack-Mount 1U

Installation Power Management Unit Battery Cables and Battery Harness

Installation Guide Smart-UPS X 2000/2200/3000 XL Tower/Rack-Mount 4U

Installation Guide Smart-UPS On-Line Replacement Battery Module APCRBC140/APCRBC140J

Installation Guide Smart-UPS On-Line External Battery Pack XBP48RM1U-LI

Smart-UPS RC External Battery Pack Tower/Rack-Mount 4U

Operation Manual. Smart-UPS C. Uninterruptible Power Supply 1000/1500/2000/3000 VA. 120/230 Vac. Tower. su0813a

User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V

Operation and Maintenance

Installation Guide. Marine Filter SURT023M SURT024M

Installation and Operation

Allen-Bradley. User Manual for 8000/10000 VA UPS. Tower/Rack-Mount 6U Uninterruptible Power Supply

Allen-Bradley. User Manual for 3000/5000 VA UPS. Tower/Rack-Mount 3U Uninterruptible Power Supply

Extended Battery Cabinet for Nfinity

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

Installation, Maintenance and Warranty Flat Plate Battery

Galaxy VM. Battery Breaker Box Installation 09/

PDU Input Power Cord. Before installation. Specifications

User Manual Easy UPS On-Line SRV Series 1000VA, 2000VA, 3000VA

AIS and 40 kva 400 V. Site Preparation and Installation Manual

Installation and Operation

User Manual Smart-UPS On-Line SRC1KI-IN, SRC1KUXI

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

Installation and Operation Manual Back-UPS BX1100CI-CN

Smart-UPS RC External Battery Pack Tower/Rack-Mount 4U

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

Operation Manual. Smart-UPS Uninterruptible Power Supply. 1000/1500/2200/3000 VA 220 Vac. Rack-Mount 2U

Operation Manual. Smart-UPS Uninterruptible Power Supply. 750/1000/1500/2200/3000 VA 100/120/230 Vac. 500 VA 100 Vac. Tower

User Manual Easy UPS On-Line SRVS Series Rack-Mount 1000VA, 2000VA, 3000VA

Operation Manual. Smart-UPS. Uninterruptible Power Supply VA Short-depth Rack-Mount with Lithium-ion batteries. 120 Vac

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

Operation Manual. Smart-UPS. Uninterruptible Power Supply. 750/1000/1500 VA Short-depth Rack-Mount with Lithium-ion batteries.

Installation and Operation Manual Back-UPS BR1000-CH

Installation and Operation Back-UPS BX550CI-CN

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

InfraStruXure PDU Power Cable

Power Distribution Units

Operation. Smart-UPS TM VT Rack-mounted kva 200/208 V

Operation Manual. Smart-UPS. Uninterruptible Power Supply. 750/1000/1500/2200/3000 VA Tower / Rack-Mount 2U. 120 Vac/230 Vac

3000VA 120/208/230VAC

Installation and Operation Manual Back-UPS BR800/1100CI-IN

Installation and Operation

Broadband PowerShield. CP27U Models. User Manual

Power Distribution Units AP9560 & AP9561

APC Smart-UPS 2200/3000 VA 230 VAC. Uninterruptible Power Supply

Galaxy Receiving and Unpacking 09/

BroadBand PowerShield. 20 AHr Battery. User Manual

Connecting External Battery Cabinet(s) to the UNITY/I 9910-UPS

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

Installation Guide Smart-UPS On-Line SRT 2-Post Rack-Mount Rail Kit

Symmetra PX. 48, 96, and 160 kw 400 V 100 kw 208 V. Operation 09/

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

Galaxy 300 Battery Breaker Kit G3HTBKIT1

Operation Manual. Smart-UPS Uninterruptible Power Supply. Rack-Mount 2U. 750/1000/1500 VA 120/230 Vac VA 120 Vac. 100/120/208/230 Vac

Smart-UPS VT Rack Mounted

APC Smart-UPS RT UXI/UXICH

Powerware Vdc Extended Battery Cabinet User s Guide.

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

Operation Manual. Smart-UPS C. Uninterruptible Power Supply. 1000/1500 VA Tower / Rack-Mount 2U. 120 Vac/230 Vac

User Manual Back-UPS BE425M/425M-LM, BN450M/450M-CA

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

Installation. InfraStruXure PDU 80kW PD80F6FK1-M-14 PD80F6FK1-M PD80G6FK1-M PD80G6FK1-M-14

Symmetra PX. 48, 96, and 160 kw 400 V 100 kw 208 V Operation 07/2017.

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

Installation and Operation Smart-UPS SUA500PDR

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

Installation and Operation Manual Smart-UPS Tower 220/230/240 Vac SRC1000ICCIND; SRC1000UXIND

Symmetra PX. 48 kw 400 V, 96 kw 400 V, 100 kw 208 V, 160 kw 400 V. Receiving and Unpacking 01/2016.

User s Manual. English. APC Smart-UPS RT. 3000/5000 VA VAC 3U Tower/Rack Mount Uninterruptible Power Supply

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

User Manual. English. APC Smart-UPS. 7500/10000 VA VAC 6U Tower/Rack Mount Uninterruptible Power Supply B 02/2004

Eaton Battery Charger Module Models ASY-0652 and ASY-0675 User s Guide

Installation and Operation

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

USER'S GUIDE. WiseHP11 SINGLE PHASE HIGH PRECISION AVR SERVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

Installation and user manual 5SC 500 5SC 750 5SC SC SC 500G 5SC 750G 5SC 1500G ENGLISH. Copyright 2013 EATON All rights reserved.

Operation Manual. Smart-UPS. Uninterruptible Power Supply. Rack-Mount 1U. 1200/1500 VA 100/120/230 Vac

APC Smart-UPS RT UX. User s Manual. Models SURT1000UXI and SURT2000UXI 220/230/240 Tower/Rack Mount Uninterruptible Power Supply.

Foreword

Addendum. Remote Air-Cooled Condenser

Illuminator System Series CIII

BRAVER UPS. (Uninterruptible Power System) User s Manual

Operation. Symmetra PX 48, 96, and 160 kw 400 V 100 kw 208 V

POWERWARE User s Guide VA.

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

Installation and Operation

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

Symmetra PX kw and 20 kw 208 V Operation 10/2016.

Illuminator System Series CM

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

CTFRP Series Power Supplies

Galaxy VM. Classic Battery Cabinet Installation GVMCBCWUE, GVMCBC2WUE, GVMCBC2WUF, GVMCBC3WUF 07/2017.

Transcription:

Start UP Guide Symmetra LX Tower Rack-Mount UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva 200 V, 4-16 kva 208/240 V, 4-16 kva 220/230/240 V, 4-16 kva

Important Safety Messages SAVE THESE INSTRUCTIONS - This manual contains important instructions that should be followed during installation and maintenance of the APC TM by Schneider Electric equipment and batteries. Read the instructions carefully. Become familiar with the device before trying to install, operate, service or maintain it. The following special messages may appear throughout this document or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies a procedure. The addition of this symbol to a Danger or Warning product safety label indicates that an electrical hazard exists that will result in personal injury if the instructions are not followed. This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. DANGER DANGER indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION CAUTION indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE NOTICE is used to address practices not related to physical injury. Product Handling Guidelines <18 kg <40 lb 18-32 kg 40-70 lb 32-55 kg 70-120 lb >55 kg >120 lb 1

Safety and General Information Inspect the package contents upon receipt. Notify the carrier and dealer if there is any damage. This equipment is for use in a restricted access location. Adhere to all national and local electrical codes. All wiring must be performed by a qualified electrician. Do not work alone under hazardous conditions. Changes and modifications to this unit not expressly approved by Schneider Electric IT Corporation could void the warranty. This UPS is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with fluids, or where there is excessive dust or humidity. Be sure the air vents on the UPS are not blocked. Allow adequate space for proper ventilation. For a UPS with a factory installed power cord, connect the UPS power cable directly to a wall outlet. Do not use surge protectors or extension cords. The equipment is heavy. Always practice safe lifting techniques adequate for the weight of the equipment. The batteries are heavy. Remove the batteries before installing the UPS and external battery packs (XLBPs), in a rack. Always install XLBPs at the bottom in rack-mount configurations. The UPS must be installed above the XLBPs. Always install peripheral equipment above the UPS in rack-mount configurations. Electrical safety Do not handle any metallic connector before power has been disconnected. For models with a hardwired input, the connection to the branch circuit (mains) must be performed by a qualified electrician. 230 V models only: In order to maintain compliance with the EMC directive for products sold in Europe, output cords attached to the UPS must not exceed 10 meters in length. The protective earth conductor for the UPS carries the leakage current from the load devices (computer equipment). An insulated ground conductor is to be installed as part of the branch circuit that supplies the UPS. The conductor must have the same size and insulation material as the grounded and ungrounded branch circuit supply conductors. The conductor will typically be green, with or without a yellow stripe. Leakage current for a pluggable, Type A UPS may exceed 3.5 ma when a separate ground terminal is used. The UPS input ground conductor must be properly bonded to protective earth at the service panel. If the UPS input power is supplied by a separately derived system, the ground conductor must be properly bonded at the supply transformer or motor generator set. Hardwire safety Check that all branch circuit (mains) and low voltage (control) circuits are deenergized, and locked out before installing cables or making connections, whether in the junction box or to the UPS. All wiring must be performed by a qualified electrician. Select wire size and connectors according to national and local codes. Wiring must be approved by a local wiring inspector. Strain relief is required for all hardwiring (supplied with select products). Snap in type strain reliefs are recommended. All openings that allow access to UPS hardwire terminals must be covered. Failure to do so may result in personal injury or equipment damage. 2

De-energizing safety The UPS contains internal batteries and may present a shock hazard even when disconnected from AC and DC power. The AC and DC output connectors may be energized by remote or automatic control at any time. Before installing or servicing the equipment perform the following tasks: Set the System enable switch to the OFF position. Set the input circuit breaker to the OFF position. Disconnect the battery modules. Disconnect external battery cabinet if provided. Disconnect mains/branch circuit. Battery safety When replacing batteries, replace with the same number and type. Batteries typically last for two to five years. Environmental factors impact battery life. Elevated ambient temperatures, poor quality utility power, and frequent short duration discharges will shorten battery life. Batteries should be replaced before end of life. Replace batteries immediately when the unit indicates battery replacement is necessary. APC TM by Schneider Electric uses Maintenance-Free sealed Lead Acid batteries. Under normal use and handling, there is no contact with the internal components of the battery. Over charging, over heating or other misuse of batteries can result in a discharge of battery electrolyte. Released electrolyte is toxic and may be harmful to the skin and eyes. CAUTION: Before installing or replacing the batteries, remove jewelry such as chains, wristwatches and rings. Use tools with insulated handles. High short circuit current through conductive materials could cause severe burns. CAUTION: Do not dispose of batteries in a fire. The batteries may explode. CAUTION: Do not open or mutilate batteries. Released material is harmful to the skin and eyes and may be toxic. General information The model and serial numbers are located on a small, rear panel label. For some models, an additional label is located on the chassis under the front bezel. Always recycle used batteries. Recycle the package materials or save them for reuse. 3

Installation DANGER RISK OF ELECTRIC SHOCK Adhere to all national and local electrical codes. Wiring must be performed by a qualified electrician. Read and follow all safety and installation instructions in this manual. Failure to follow these instructions could result in equipment damage, personal injury or death. CAUTION RISK OF ELECTRIC SHOCK Disconnect the electrical panel circuit breaker before installing or servicing the unit or connected equipment. Disconnect equipment from the unit before servicing any equipment. The AC and DC output connectors may be energized by remote or automatic control at any time. Do not use the UPS as a safety disconnect. Failure to follow these instructions could result in minor or moderate injury. CAUTION RISK OF ELECTRIC SHOCK Wire gauge must comply with required amp capacity and national and local electrical codes. Use Snap-In strain reliefs provided with the unit. The UPS must be wired into a branch circuit equipped with a circuit breaker rated as specified in the tables below. Recommended input terminal screw torgue: 16 lbf-in (2 Nm). Once hardwiring is completed, all openings in the hardwire assembly must be covered. Failure to follow these instructions could result in minor or moderate injury. 4

Turn Off Power to UPS Turn OFF the AC utility power to the UPS. Turn OFF the UPS input circuit breaker. 220/230/240 V sy10054b 200/208 V Turn OFF the system enable switch. system enable switch sy10074b Install Symmetra LX Refer to the Symmetra LX UPS Physical Installation Guide for UPS and peripheral module installation instructions. Refer to the Symmetra LX Extended Run Cabinet Physical Installation Guide for Extended Run Cabinet installation instructions. 5

Electrical Connections Symmetra LX wiring Refer to the Symmetra LX Electrical Installation Guide for input and output power connections. System installation checklist DANGER RISK OF ELECTRIC SHOCK Adhere to all national and local electrical codes. Wiring must be performed by a qualified electrician. Read and follow all safety and installation instructions in this manual. Read and follow all safety and installation instructions in manuals referenced in this manual. Failure to follow these instructions could result in equipment damage, personal injury or death. Refer to the Symmetra LX Physical Installation Guide and the Symmetra LX Electrical Installation Guide for detailed instructions. Disconnect all equipment connected to the UPS. Verify that all rack mount components are properly secured in the rack. Verify that power modules, battery modules, and intelligence modules are properly installed. Verify that the PowerView is connected to an Intelligence module (IM). Turn ON UPS AC utility power. Turn ON the input circuit breaker and the system enable switch. 220/230/240 V system enable switch 200/208 V sy10072b sy10074c During initial startup clicking sounds may be heard. During initial startup the PowerView may display diagnostic messages. Disregard these messages. Press the Esc button on the PowerView until the monitoring screen is displayed. Verify that the input voltage (Vin), matches the branch circuit (mains), voltage. 6

System installation checklist continued Turn ON the maintenance bypass switch. 200/208 V 220/230/240 V sy10140a Disregard any LED indicators or diagnostic messages on the PowerView. Press the Esc button on the PowerView until the monitoring screen is displayed. Verify that the input voltage (Vin), matches the branch circuit (mains), voltage. Test the REPO switch. The system enable switch should move to the standby position, and the system should shut down. Turn OFF the input circuit breaker, the system enable switch and the maintenance bypass switch. 7

System Startup Refer to the Symmetra Operations Guide for detailed instructions. Turn ON the UPS Turn ON the AC utility power. Turn ON the circuit breakers for all connected equipment. If connected equipment is hardwired, verify that the output circuit breakers on the distribution panel are switched ON. sy10146a If connected equipment is plugged into the UPS, verify that each UPS PDU output circuit breaker is switched ON sy10147a Turn ON the input circuit breaker. 220/230/240 V 200/208 V sy10072b 8

Turn ON the UPS continued Turn ON the UPS system enable switch system enable switch sy10074c To start the UPS when there is no AC utility power, press and hold either of the cold start buttons for four seconds. sy10148a 9

Setting PowerView Screens Once the PowerView has gone through the initial diagnostics during system startup, monitoring screens that provide operating parameters can be set. Chg 100% Load 000% 220 Vin 000 Vout 60 Hz Runtime: 00hr 30min Set output voltage Press the ESC button until the Main menu screen appears. Use the up/down arrow keys to scroll through the options. Select Setup and press ENTER. Use the up/down arrow keys to scroll through the options. Select Other and press ENTER. Control Status >Setup Accessories Settings Shutdown Defaults Output Freq Logging Display Diags Help Alarms Bypass Copy >Other To change the output voltage for a specific application use the up/ down arrow keys to scroll through the options. Select Output. The cursor will move to the voltage field. Use the up/down arrows to scroll through voltage options. Select the voltage needed and press ENTER. Turn ON connected equipment The Symmetra LX must be turned ON before executing this procedure. Press the ESC button until the Main menu screen appears. Use the up/down arrow keys to scroll through the options. Select Control and press ENTER. Use the up/down arrow keys to scroll through the options. Select Turn UPS Output On, and press ENTER. NOTE: You may need to scroll down to a second page. Self Test : UPS ID : Vout Reporting : >Output : Control Status >Setup Accessories Enabled UPS_IDEN Auto 208V Graceful Turn On Start Runtime Cal >Turn UPS Output On Logging Display Diags Help Confirm choice by selecting YES. There may be clicking sounds and this message may appear. NOTE: You may see one or more override warnings. Answer these by selecting Start Now. UPS HAS BEEN COMMANDED TO TURN POWER ON When this message appears, there will be a 90 second delay before the Load On LED will illuminate. UPS LOAD IS ON Press any key... 10

APC by Schneider Electric Worldwide Customer Support Customer support for this or any other Symmetra by Schneider Electric product is available at no charge in any of the following ways: Visit the APC by Schneider Electric web site, www.apc.com to access documents in the APC Knowledge Base and to submit customer support requests. www.apc.com (Corporate Headquarters) Connect to localized APC by Schneider Electric web site for specific countries, each of which provides customer support information. www.apc.com/support/ Global support searching APC Knowledge Base and using e-support. Contact the APC by Schneider Electric Customer Support Center by telephone or e-mail. Local, country specific centers: go to www.apc.com/support/contact for contact information. For information on how to obtain local customer support, contact the APC by Schneider Electric representative or other distributor from whom you purchased your APC by Schneider Electric product. 2018 APC by Schneider Electric. APC, the APC logo, Smart-UPS and Symmetra are owned by Schneider Electric Industries S.A.S. or their affiliated companies. All other trademarks are property of their respective owners. EN 990-1541C 06/2018