SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

Similar documents
CFSD Series. Product Description

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

SafidDampers SPK Description. Standard Construction SPK ( Flange Type )

Motorized Fire Dampers

Model FSD-212. Combination FIRE SMOKE DAMPERS

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model FSD-331 Combination Fire Smoke Dampers

SMOKE DAMPER - CLASS F MODEL BMSD

COMBINATION FIRE/SMOKE DAMPER - CLASS F MODEL BMFSD (3 HR) / MODEL BEMFSD (1½ HR)

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

VCD-23 Low Leakage CONTROL DAMPER

VCD-23. Low Leakage CONTROL DAMPER

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

Fire Dampers Catalogue

Model VCD-20 3V CONTROL DAMPER

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

Model VCD-43 Extruded Airfoil Blade Control Damper

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.

VCD-23. Flange Options. Size Limitations

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories.

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2

ARROW UNITED INDUSTRIES

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR

AMD-33 Air Measuring Station with VCD-33 Control Damper

FSD60/MFSD60 Multi-blade Fire Damper

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

ARROW INDUSTRIAL PRODUCTS

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section

SD-1250 and SD-1600 Series Smoke Dampers

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES

MULTI-BLADE FIRE DAMPERS

Installation, Operation and Maintenance Manual

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

Fire, Smoke, and Combination Fire Smoke Dampers

Standard Installation Fire/Smoke Damper Models: FR1, FR2 Smoke Damper Models: SR1, SR2

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

MULTI-BLADE FIRE DAMPERS

EnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

Installation, Operation and Maintenance Manual

Thermal Isolation. Break

HCD-230 Industrial Control Damper

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed

DD Series. Duct Regulating Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S. Two blade options.

BC 03. Fire Dampers FD-GB-30-AS LISTED

BC Motorized Fire Smoke Dampers MSFD-GB-30C1-A MSFD-GB-30C1-A LISTED

Smoke Dampers. Installation Instructions

Standard Installation Combination Fire/Smoke Damper Models: FS1(SS), FS2(SS) Fire Damper Models: MD19(SS)

Zero Leakage Isolation Damper

Standard Installation Combination Fire/Smoke Damper Models: FS1, FS2, FT1, FT2, FA1, FA2, TA1, TA2, FS2C2 Fire Damper Models: MD19, MD39, MA19, MA39

Control Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers

Dampers. Louvers. Caring for Human Life & Property (FIRE, SMOKE & HVAC) NAFFCOFlow.com

ID-141x 12-Gauge Hat Channel Industrial Damper

AL-Maraj Central A/C Systems Accessories Mfg Co.

Introduction to Johnson Controls Dampers

MOTORIZED VOLUME DAMPER

VOLUME CONTROL / REGULATING DAMPERS

Standard Installation Combination Fire/Smoke Damper Models: FS1, FS2, FT1, FT2, FA1, FA2, TA1, TA2 Fire Damper Models: MD19, MD39, MA19, MA39

MODEL 151B FIRE DAMPER

VC Series. Volume Control Dampers M A N U F A C T U R E R S O F A I R, F I R E A N D S M O K E C O N T R O L P R O D U C T S

VOLUME CONTROL DAMPERS

BD-1600 Balancing/Zone Control Damper

Actionair Control and Shut Off Dampers

Life Safety Dampers. Fire Combination Fire Smoke Smoke Ceiling Radiation

Model FD-350. Static Rated Fire Dampers 3 Hour Fire Resistance Rating. Application. Ratings. Construction Standard Optional.

SP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER

CONTROL & BACKDRAFT DAMPERS. Nailor. Industries Inc.

AMCA MEMBER. American Warming and Ventilating. A Mestek Company. Quality Air Control Dampers

HEAVY DUTY BALANCE AND CONTROL DAMPER B A L A N C E C O N T R O L SERIES

Series HCD Airfoil Control Damper

AMCA International. Guide for Commissioning and Periodic Performance Testing of Fire, Smoke and Other Life Safety Related Dampers

SECTION AXIAL HVAC FANS

VOLUME CONTROL & SHUT OFF DAMPERS SERIES 400

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

Marine Fire and Gas Dampers

Transcription:

SMOKE DAMPERS 96 97

SD SERIES SD for Use in Dynamic Systems Types Galvanized Steel Construction as Standard.. Sleeve Type, Model: SD - 0-00. Circular Type, Model: SD - 50-00. Oval Type, Model: SD - 60-00 Linkage Bar: Stainless steel type 0, 5mm x mm thick. Linkage Bracket: GI 50mm x 60mm x mm thick, fixed with square axle 9.5 mm and Ø6.mm Pin. Leakage Resistance: Class I - 50 F and Class II - 50 F. With factory installed Sleeve, Model: SD - 80-00 Crank: mm thick galvanized steel sheet mm x 07mm with Dynamic Closure Ratings: 000 FPM and 000 FPM Air Velocity Cloase Damper Pressure Rating: inch W.G. UL File No.: R65 Optional Construction: Same as the standard construction but blades, stub shaft (latch) with pieces Ø6mm bolts & nuts, axles and linkage brackets with axle in stainless steel Grade 0. 6.6mm wide slot. Axle: Zinc plated steel square bar 9.5 x 9.5 mm. Stub Shaft (Latch): Die pressed galvanized steel sheet, 58mm x 68mm x Optional: Blades from stainless steel Grade 6 or.5mm thick (Ga.6). 6L.. Sleeve Type, Model: SD - 0-0 Bearings: Sintered bronze oilite type. Product Description Smoke dampers provide an automatic means of isolating the smoke zones where the fire is located to prevent the spread of smoke in adjacent areas or in exit. Circular Type, Model: SD - 50-0. Oval Type, Model: SD - 60-0. With factory installed Sleeve, Model: SD - 80-0 Same as the standard construction but frame, blades, installation sleeve and all accessories in stainless steel Grade 0. Optional: Frame, blades and installation sleeve from stainless steel Grade 6 or 6L. Side Seal (Jamb Seal): Compression type SS grade 0, 0.mm thick. Blade Tip Seal: Blade tip seals are high temperature Durometer Dense Silicone. Jack Shaft: GI rod Ømm across the blade length with 0mm square end x 5mmL to suit actuator. passageways which is greatly contribute to the safety of life and property in the early stage of fire. It is suitable for installation in sheet metal ductworks, openings in walls or floor slabs made from concrete, bricks and in lightweight partition walls. These type of dampers offer an effective smoke barrier maintaining the integrity in a fire situation which has a very low leakage characteristic, tested / evaluated by Underwriters Laboratories Inc. (UL) as per UL 555S Standard for Safety Smoke Dampers, which. Sleeve Type, Model: SD - 0-0. Circular Type, Model: SD - 50-0. Oval Type, Model: SD - 60-0. With factory installed Sleeve, Model: SD - 80-0 Standard Construction Finish: Mill Galvanized Jack Shaft Holder: Die pressed GI steel 5.9mm x 8.mm x.5mm thick with Ø.7mm ball bearing. Minimum Size: 00W x 50H mm with single blade construction up to 50mm height. Maximum Size: 9W x 9H mm - Single section and 88W x 88H - Multiple Section complies with the requirements of NFPA 90A for use in engineered Smoke Control Systems. Sleeve:.5mm thick (Ga.6) galvanized steel sheet. Mounting: Vertical and Horizontal SAFID smoke dampers are UL Classified and has a Leakage Ratings of Class I at 50 F and Class II at 50 F elevated temperature. Smoke dampers willl be controlled by an automatic alarm initiating device which is interlocked with damper actuator. The Smoke dampers do not need to be equipped with a fusible link or tripping device. In today s life safety products markets, many building code require smoke dampers to be inspected for proper operation. All damper moving parts must be inspected and cycled at every six months and in accordance to the latest NFPA90A/9A and local codes. Frame: 0 x.5 x.5mm thick (Ga.6) galvanized steel hat channel. Blades:.5mm thick (Ga.6) galvanized steel Triple Vee (V) groove type (standard). Blade Stop:.5mm thick (Ga.6) galvanized steel sheet bend at 5 angle. Linkage: Side linkage concealed in frame (Standard). UL Test Ratings Air Leakage Test: Class I and Class II Elevated Temp. Test: 50 F and 50 F Dynamic Closure Test: Rated at 000 FPM and 000 FPM Air Velocity Rated Pressure: Tested to.5 inch W.G. and rated at inch W.G. 98 99

Types Sleeve Type Model: SD - 0 Types Circular Type Model: SD - 50 0 75 + WALL THICKNESS DIA - DIA + 5 DIA + 5 W - 5 H - 5 Flat Oval Tyoe Model: SD - 60. Casing (Frame). Linkage Bracket. Blade. Linkage Bar 5. Bearings 6. Blade Stop 7. Side Seal 8. Blade Tip Seal 9. Lock Washer and GI Round Washer 0. Kneelock. Jackshaft H - W - 75 + WALL THICKNESS W + 5 H + 5 00 0

Types Smoke Damper with Factory Installed Sleeve and Actuator Model: SD - 80 Dimensions - Single Section SD With Factory Installed Sleeve and Actuator Model: SD - 80 Height: Up to 0 mm Front View Side View Schedule of Damper Sizes and Actuator Types A. Single section damper with two position (open/close) spring retrun type actuators:. Damper Frame 9. Auxiliary Switch Cable for Indicating Damper Blades. Sleeve. Blade. Linkage Bracket 5. Lock Washer and Galvanized Round Washer 6. Kneelock 7. Linkage Bar 8. Actuator Position 0. Power Supply. Blade Stop. Stainless Steel Side Seal. Blade Tip Seal. Jackshaft 5. Axle 6. Bearing. BELIMO Model: FSLF-S-US ( / 0VAC) with built-in auxiliary switch. Torque:.5Nm for W = 60 mm maximum.. Model: MS80F0 / MS60F0 ( / 0VAC) with built-in auxiliary switch. Torque:.5Nm for W = 60 mm maximum.. BELIMO Model: BF-S-ME ( / 0VAC) with built-in auxiliary swith. Torque: 5 Nm for W = 9 mm maximum. Refer to technical data sheet of actuator or contact SAFID for the actuator specifications. 0 0

Dimensions - Single Section Dimensions - Multiple Section SD With Factory Installed Sleeve and Actuator Model: SD - 80 Height: Up to 9 mm SD With Factory Installed Sleeve and Actuator Model: SD - 80 Width: Up to 00 mm Height: Up to 9 mm Front View Side View Front View Side View Schedule of Damper Sizes and Actuator Types A. Single section damper with two position (open/close) spring retrun type actuators:. BELIMO Model: FSLF-S-US ( / 0VAC) with built-in auxiliary switch. Schedule of Damper Sizes and Actuator Types Torque:.5 Nm Damper size: W=60mm maximum, H=06mm maximum A. Multiple section damper with two position (open/close) spring retrun type actuators:. Model: MS80F0/MS60F0 ( / 0VAC) with built-in auxiliary switch. Torque:.5 Nm Damper size: W=60mm maximum, H=06mm maximum. BELIMO Model: FSNF-S-US ( / 0VAC) with built-in auxiliary switch.. Model: MS60F0 (0VAC) with built-in auxiliary switch. MS80F00 (VAC) with built-in auxiliary switch. Torque: 0 Nm Torque: 8 Nm Damper size: W=60mm maximum, H=60mm maximum. BELIMO Model: BF-S-ME ( / 0VAC) with built-in auxiliary swith. Torque: 5 Nm Damper size: W= 9mm maximum, H= 9mm maximum Refer to technical data sheet of actuator or contact SAFID for the actuator specifications. Note: Location of the actuator can be INSIDE or OUTSIDE the airstream. Refer to technical data sheet of actuator or contact SAFID for the actuator specifications. 0 05

Dimensions - Multiple Section Dimensions - Multiple Section SD With Factory Installed Sleeve and Actuator Model: SD - 80 Width: Up to 88 mm Height: Up to 9 mm SD With Factory Installed Sleeve and Actuator Model: SD - 80 Width: Up to 00 mm Height: Up to 88 mm Front View Side View Front View Side View Schedule of Damper Sizes and Actuator Types A. Multiple section damper with two position (open/close) spring retrun type actuators:. Model: MS60F0 (0VAC) with built-in auxiliary switch. MS80F00 (VAC) with built-in auxiliary switch. Torque: 0 Nm Schedule of Damper Sizes and Actuator Types Note: Location of the actuator can be INSIDE or OUTSIDE the airstream. A. Multiple section damper with two position (open/close) spring retrun type actuators: Refer to technical data sheet of actuator or contact SAFID for the actuator specifications.. Model: MS60F0 (0VAC) with built-in auxiliary switch. MS80F00 (VAC) with built-in auxiliary switch. Torque: 0 Nm Note: Location of the actuator can be INSIDE or OUTSIDE the airstream. Refer to technical data sheet of actuator or contact SAFID for the actuator specifications. 06 07

INSTALLATION DETAILS Dimensions - Multiple Section SD With Factory Installed Sleeve and Actuator Model: SD - 80 Width: Up to 88 mm Height: Up to 88 mm Installation Details SD with Factory Installed Sleeve and Actuator Model: SD - 80 Typical Installation Front View Side View Schedule of Damper Sizes and Actuator Types Notes: A. Multiple section damper with two position (open/close) spring retrun type actuators:. Airflow can be at opposite direction.. Model: MS60F0 (0VAC) with built-in auxiliary switch. MS80F00 (VAC) with built-in auxiliary switch. Torque: 0 Nm Note: Location of the actuator can be INSIDE or OUTSIDE the airstream. Refer to technical data sheet of actuator or contact SAFID for the actuator specifications.. The actuator can be located in either side of the wall.. Refer to installation manual for further installation detail. The Smoke Damper will be installed at the smoke barrier penetrations in accordance with NFPA 90A. 08 09

ACTUATORS AIR PERFORMANCE Actuators Air Performance Pressure Drop The test method for the pressure drop of the Smoke Damper was conducted as per ANSI/AMCA Standard -D, Figure 5. which simulate the actual site condition when installed in ventilation, supply and return air conditioning ductworks. AMCA Test Figure 5. Belimo Actuator Model: FSLF Belimo Actuator Model: FSNF Belimo Actuator Model: BF Honeywell Actuator Model: MS60F0 Sequence of Operation Pressure Drop at Face Area Velocity Smoke Mode: When a signal detected through normally closed smoke detector (by others) connection, the power supply to the fire and smoke damper actuator will be interrupted. The energy stored in the damper actuator moves the damper back to its safe position and remain closed until the smoke signal close down. The system will reset after power is reapplied to the actuator and damper will open. By placing an optional control switch (by others), the damper blades at open position can be closed at any time if required. A- Damper Size: in. x in. - Fully open blades B- Damper Size: in. x in. - Fully open blades C- Damper Size: 6in. x 6in. - Fully open blades Typical Wiring Diagram Belimo Actuator Models: BF, FSNF and FSLF Honeywell Actuator Model: MS60F0 0

ORDER REFERENCE DETAILS ORDER REFERENCE DETAILS Order Details Specifications Order Example Order Code Variants SD-0 = Sleeve Type SD-50 = Circular Spigot SD-60 = Oval Spigot SD-80 = Factory Installed Sleeve Types 00 = Galvanized Steel Construction 0 = Blades of Stainless Steel Grade 0 Optional: Grade 6 or 6L SD-80-00 - V - PB - R - AS - V / x 0 = Stainless Steel Construction S/S Grade 0 Optional: Grade 6 or 6L Duct Size Width x Height or Diameter. All damper s spigot sizes (slip-in type) will be manufactured less than duct size to fit inside the ductwork connections. Power Supply V = VAC V = 0 VAC Smoke dampers with the following specifications shall be used in Heating, Ventilating and Air Conditioning (HVAC) Duct Systems passing through openings in masonry walls, concrete floor slabs, and in light partition walls designed as smoke barrier to restrict the spread of smoke. It shall be also used in Smoke Exhaust System and in Smoke Proof Stair Enclosure in accordance to NFPA 90A Standard for Installation of Air Conditioning and Ventilating Systems, and to NFPA 0 Life Safety Code. Smoke dampers will be tested and classified by Underwriters Laboratories Inc. (UL) in accordance with the standards, UL 555S Standard for Safety, Smoke Dampers. Smoke dampers will have a Leakage Resistance Rating of Class I at 50 F or Class II at 50 F elevated temperature. It shall be tested for heated air operation test with air velocity of 00 FPM to be rated at 000 FPM and the test pressure shall be.5 inch W.G. static pressure to be rated at inch W. G. Pressure Class. SAFID Smoke Damper, galvanized steel construction, V groove blade for parallel blades operation, mm width x mm height duct size and right hand side external controls. Damper shall be with factory installed sleeve and 0 VAC BELIMO actuator with built-in auxiliary switch. Make: SAFID Type: SD-80-00-V-PB-R-AS-V Size: W x H Qty: Types of Blades V = V Groove Type Linkage PB = Slide Linkage Parallel Blades Operation Smoke Damper shall be fitted with UL Listed BELIMO spring return actuator and shall be controlled by smoke detector. The power supply to the actuator shall be cut-off as soon as the smoke detector detect the smoke. External Controls R = Right Hand (Standard Supply) L = Left Hand Actuators Belimo, BF-S-ME Belimo, FSNF-S-US Belimo, FSLF-S-US Honeywell, MS60F0 Damper blades will be with external linkage and parallel action, Ga.6 galvanized steel with V groove type for longitudinal reinforcement. Blade s tip seal shall be Type 60 Durometer Dense Silicone, meets gasket requirements in accordance with UL 555S. Blade s axel shall be 9.5 x 9.5mm square forcedfit to one stub shaft, secured to blade with pieces of bolt and nut, and with sintered bronze oilite axle bearing. Jamb seal/side seal shall be stainless steel to fill gap between blade s end and frame. Jackshaft shall be Ømm galvanized steel with a crank and kneelock secured to the linkage bracket. Damper frame shells will be Ga.6 galvanized steel formed into hat channel shape.

FLANGE TYPE SMOKE DAMPER FLANGE TYPE SMOKE DAMPER SMD 0-00 SMD SERIES FLANGE TYPE SMD SERIES [SMD 0-00, SMD 0-0, SMD 0-0] Dimensions - Casing - Blade - Drive Shaft - Side Linkage 5 - Linkage Bar 6 - Landing Angles 7 - Bearing Flange Type SMD 0-00, 0, 0 Description Smoke dampers type SMD 0 provide an automatic means of localizing areas of smoke in ventilation systems. It prevent the distribution of smoke through ventilation Maximum Size: 00 x mm, as single section. Multiple section assembly with unlimited size, where each section operates independently. ductworks. SMD combined with low leakage characteristic for smoke management, is suitable for installation in sheet For details of multiple sections consult SAFID. metal ductworks or in walls or ceiling slabs made from concrete, brick and lightweight partition walls. SMD is available for rectangular, square, circular and flat oval duct fixings. SMD 0-0 General construction as type SMD 0-00 damper but blades, shafts and blade to shaft fixing in stainless steel (Grade 0). Flange Type, Parallel Blades Standard Sizes Standard Construction Frame: 60mm x 0mmx.5mm (6 ga.) galvanized steel, formed channel for flange connections. SMD 0-0 General construction as type SMD 0-00 damper but with frame, blades shafts and blade to shaft fixing and linkage all from stainless steel (Grade 0). Width (mm) 00 50 00 Height (mm) 00 50 00 No. of Blades Blades: 50mm max. width,.5mm (6 ga.) galvanized steel. 50 00 50 00 Finish: Mill galvanized. 50 00 50 50 00 50 Linkage: Side linkage concealed in frame for parallel blade operation is standard. Face linkage available (optional). Linkage consist of 6mm dia. S/S pivot pins. Case Bearings: Made of sintered bronze (oilite), operational temp. resistance up to 00 C. Axles and Control Shaft: mm diameter zinc plated mild steel. Minimum Size: 00 x 00mm, damper up to 50mm high is single blade construction. Parallel Blade (PB) 550 650 750 850 950 000 050 00 00 000 00 00 00 00 5 5 6 7 7 8 9 9 0 5

SLEEVE TYPE SMOKE DAMPER SLEEVE TYPE SMOKE DAMPER SMD 0-00 SMD SERIES SLEEVE TYPE SMD SERIES [SMD 0-00, SMD 0-0, SMD 0-0] Dimensions - Casing - Blade - Drive Shaft /Removable Spindle (when required) - Side Linkage 5 - Linkage Bar 6 - Landing Angles Circular Spigot Type SMD 0-00, 0, 0 Description Smoke dampers type SMD 0 provide an automatic means of localizing areas of smoke in ventilation systems. It prevent the distribution of smoke through ventilation Maximum Size: 00 x mm, as single section. Multiple section assembly with unlimited size, where each section operates independently. ductworks. SMD combined with low leakage characteristic for smoke management, is suitable for installation in sheet For details of multiple sections consult SAFID. metal ductworks or in walls or ceiling slabs made from concrete, brick and lightweight partition walls. SMD is available for rectangular, square, circular and flat oval duct fixings. SMD 0-0 General construction as type SMD 0-00 damper but blades, shafts and blade to shaft fixing in stainless steel Sleeve Type, Parallel Blades Standard Sizes Standard Construction (Grade 0). Width (mm) Height (mm) No. of Blades Frame: 00mm x 0mm x.5mm (6 ga.) galvanized steel, structurally designed hat section. Blades: 00mm max. width,.5mm (6 ga.) galvanized steel. SMD 0-0 General construction as type SMD 0-00 damper but with frame, blades shafts and blade to shaft fixing and linkage all from stainless steel (Grade 0). 00 50 00 50 00 50 00 50 00 50 00 50 Finish: Mill galvanized. Linkage: Face linkage for parallel blade operation is standard. Face linkage parallel blades available (optional). Linkage consist of 6mm dia. S/S pivot pins. 00 50 550 650 00 50 Case Bearings: Made of sintered bronze (oilite), operational temp. resistance up to 00 C. Axles and Control Shaft: mm diameter zinc plated mild steel. Minimum Size: 00 x 00mm, damper up to 00mm high is single blade construction. Parallel Blade (PB) 750 850 950 000 050 00 00 00 000 00 00 00 00 6 6 7 8 8 9 0 6 7

CIRCULAR SPIGOT TYPE SMOKE DAMPER CIRCULAR SPIGOT TYPE SMOKE DAMPER SMD 50-00 SMD SERIES CIRCULAR SPIGOT TYPE SMD SERIES [SMD 50-00, SMD 50-0, SMD 50-0] Dimensions - Casing - Blade - Drive Shaft - Side Linkage 5 - Linkage Bar 6 - Landing Angles 7 - Bearing 8 - Spigot Case Circular Spigot Type SMD 50-00, 0, 0 Description Smoke dampers type SMD 50 provide an automatic means of localizing areas of smoke in ventilation systems. It prevent the distribution of smoke through ventilation Maximum Size: 000mm diameter, as single section. Multiple section assembly with unlimited size, where each section operates independently. ductworks. SMD combined with low leakage characteristic for smoke management, is suitable for installation in sheet For details of multiple sections consult SAFID. metal ductworks or in walls or ceiling slabs made from concrete, brick and lightweight partition walls. SMD is available for rectangular, square, circular and flat oval duct fixings. SMD 50-0 General construction as type SMD 50-00 damper but blades, shafts and blade to shaft fixing in stainless steel (Grade 0). Standard Construction Frame: 80mm x.5mm (6 ga.) galvanized steel, spigot type 80mm wide with circular spigot duct connection. SMD 50-0 General construction as type SMD 50-00 damper but with frame, blades shafts and blade to shaft fixing and linkage all from stainless steel (Grade 0). Circular Spigot Type, Parallel Blades Standard Sizes Diameter (mm) 00 No. of Blades Blades: 50mm max. width,.5mm (6 ga.) galvanized steel. 50 00 Finish: Mill galvanized. 50 00 50 Linkage: Side linkage for parallel blade operation is standard. 00 50 Face linkage parallel blades available (optional). Linkage consist of 6mm dia. S/S pivot pins. Case Bearings: Made of sintered bronze (oilite), operational temp. resistance up to 00 C. Axles and Control Shaft: mm diameter zinc plated mild steel. Minimum Size: 00 mm diameter, damper up to 50mm dia. is single blade construction. Parallel Blade (PB) 000 5 6 7 8 9

OVAL SPIGOT TYPE SMOKE DAMPER OVAL SPIGOT TYPE SMOKE DAMPER SMD 60-00 SMD SERIES OVAL SPIGOT TYPE SMD SERIES [SMD 60-00, SMD 60-0, SMD 60-0] Dimensions - Casing - Blade - Drive Shaft - Side Linkage 5 - Linkage Bar 6 - Landing Angles 7 - Bearing 8 - Spigot Case Oval Spigot Type SMD 60-00, 0, 0 Description Smoke dampers type SMD 60 provide an automatic means of localizing areas of smoke in ventilation systems. It prevent the distribution of smoke through ventilation Maximum Size: 000 x mm, as single section. Multiple section assembly with unlimited size, where each section operates independently. ductworks. SMD combined with low leakage characteristic for smoke management, is suitable for installation in For details of multiple sections consult SAFID. sheet metal ductworks or in walls or ceiling slabs made from concrete, brick & lightweight partition walls. SMD is available for rectangular, square, circular & flat oval duct fixings. SMD 60-0 General construction as type SMD 60-00 damper but blades, shafts and blade to shaft fixing in stainless steel (Grade 0). Oval Spigot Type, Parallel Blades Standard Sizes Standard Construction Frame: 80mm x.5mm (6 ga.) galvanized steel, spigot type 80mm wide with oval spigot duct connection. SMD 60-0 General construction as type SMD 60-00 damper but with frame, blades shafts and blade to shaft fixing and linkage all from stainless steel (Grade 0). Width (mm) 00 50 00 Height (mm) 00 50 00 No. of Blades Blades: 50mm max. width,.5mm (6 ga.) galvanized steel. 50 00 50 00 Finish: Mill galvanized. 50 550 50 00 50 Linkage: Side linkage for parallel blade operation is standard. Face linkage parallel blades available (optional). Linkage consist of 6mm dia. S/S pivot pins. 650 750 5 Case Bearings: Made of sintered bronze (oilite), operational temp. resistance up to 00 C. Axles & Control Shaft: mm diameter zinc plated mild steel. Minimum Size: 00 x 00mm, damper up to 50mm high is single blade construction. Parallel Blade (PB) 850 950 000 6 0

MATERIALS CONSTRUCTION MATERIALS CONSTRUCTION Materials Construction Installation Details Flange Type SMD 0 Removable Spindle Mounting Bracket Damper to Slide On Flange Connection Damper to Flange Connection For Sleeve Type Only Damper with Mounting Bracket for Actuator Flange Installation Detail Flange Drilling Details, Type SMD 0 Flange Drilling Details Blade Seal Side Seal (Jamb Seal) Width (mm) Height (mm) No. of Holes B Dim. No. of Holes H Dim. Type S (Silicone Rubber) Type S (Stainless Steel Type 0) Note: Type S (Combination of S & S) 00 50 00 50 00 50 00 50 000 00 00 00 50 00 50 00 50 00 50 000 00 00 00 00 5 6 7 8 8 9 0 5 6 6 7 8 9 0 0 5

INSTALLATION DETAILS PRODUCT RANGE Installation Details Product Range For Sleeve type, SMD 0 Circular Type, SMD 50 Seals Belimo Actuators Construction Variants Description Code Type/Model S No seals. A0 BF0 spring return Not applicable. A0 BF spring return S Blade edge seal to seal blades to blade joint. Blade seal is silicone rubber with temperature resistance up to 75 C, for low leakage characteristic. Not applicable. A0 A0 A05 A06 AF0 spring return AF0-S spring return with limit switch AF0 US spring return AF0 US spring return S Side seals. Fitted to close gap between frame and blades. Not applicable. A07 A08 A09 AF0-S US spring return with limit switch AF0-S US spring return with limit switch AF US spring return Oval type SMD 60 S Combination of S & S, fitted to close gap between frame and blades and blade edge seals to seal blade to blade joint. Blade seals is silicone rubber with temperature resistance up to 75 C, for ultra low leakage characteristic. A0 A A A A AF-S US spring return with limit switch AF-SR spring return NF US spring return NF0 US spring return NF-S US spring return with limit switch A5 NF0-S US spring return with limit switch A6 NF-SR US Modulating Linkage A7 SM0A open/closed Construction Variants Description A8 SMA open/closed PB Side linkage concealed in frame A9 SM0A-SR Modulating forparallel blade operation. Face linkage available (optional). A0 NM0 open/closed A NM open/closed A NM SR Modulating Bearings Construction Variants B B Description Construction sintered bronze oilite. Stainless steel A GM0 open/closed A GM open/closed A5 GM-SR Modulating Note: For Belimo Actuators details, models and voltages see pages 0-9 or contact SAFID. 5

ORDER REFERENCE DETAILS SD Series Order Details Dimensions Order Code SMD 0-00 - PB - S - B - R / x - A0 Variants *SMD 0 = Flange (Standard Supply) SMD 0 = Sleeve SMD 50 = Circular Spigot SMD 60 = Oval Spigot Types *00 (Standard Supply) 0 0 Variants - Blade Operation *PB = Side Linkage Parallel (Standard Supply) Face Linkage (optional) Variants - Seals S = None (not applicable) S = Blade Seals Only (not applicable) S = Side Seal (not applicable) *S = Side Seal & Blade Seals (Standard Supply) Actuators (See page 5) Duct Size - Square or rectangular Dimensions W x H mm. - Circular D mm dia. - Flat oval W x H mm. - All damper spigots are manufactured down on duct size to fit inside ductwork connections. External Controls * R = Right Hand (Standard Supply) L = Left Hand Variants - Bearings *B = Sintered Bronze (oilite) B = Stainless Steel *-Stands for Standard Supply Specifications Order Example Rectangular, square, circular and flat oval Smoke Dampers designed for the smoke isolation of sections of ducting in ventilation systems. Flanged casing, shut off blades with overlapping interlocking joints and with side seals and blade seals for low leakage options (when required). Blades are connected by side linkage for parallel action and face linkage parallel action also available. Standard Make: SAFID Type: SMD 0-00 PB - S - B - R - x / A0 Qty: 6 7