Proportional pressure reducing valve Type FTDRE 4 K

Similar documents
Electro-Proportional Pressure Reducing and Relieving Cartridge Valves

Proportional pressure relief valve Types DBE(M) and DBE(M)E

Proportional pressure relief valve Type DBETRE

Proportional pressure relief valve Types DBE(M) and DBE(M)E

2/2-way poppet valves with solenoid operation Type KSDER1

Proportional pressure reducing valve, direct operated, increasing characteristic curve Type MHDRE 06 SK (high-performance)

RE / Check-Q-meter type FD, series 2X. Ordering details FD 2X / V * Symbols 1/8. Replaces: 03.92

Proportional pressure reducing valve, direct operated, increasing characteristic curve Type MHDRE 06 FK (high-performance)

Rexroth Hydraulics. Pressure reducing valve, pilot operated, type 3DR 3DR 10 P 6X Y 00 RE /10.97

Rexroth Hydraulics. Servo directional valve of 4-way design Type 4WS.2EM RE /03.99

4/2- and 4/3-way proportional directional valves, direct actuated, without electrical position feedback Types 4WRA and 4WRAE

Proportional pressure reducing valve, direct operated, increasing characteristic curve Type DRE05SK

Rexroth Hydraulics. Fixed displacement vane pumps Types PVV and PVQ RE /11.97

Check valve cartridge Type M-SR

Pressure reducing valve, pilot operated Type DR

4-way directional servo valve Type 4WS.2E

Proportional Pressure Reducing Valve PDM08130

Hydraulic Motor (Radial piston multi-stroke)

Double throttle check valve Type Z2FS 10

Proportional pressure reducing valve of 3-way design Types 3DREP and 3DREPE

Proportional pressure relief valve, directly operated, rising characteristic curve

Priority valve Type LPS

Proportional pressure relief valve, pilot operated

Proportional cartridge throttle valve, with inductive position transducer, pilot operated

Proportional pressure reducing valve, pilot operated

Proportional flow control valve, with integrated pressure compensator

Pipe burst safety valve Type MHRB

4/2- and 4/3-way proportional directional valves, direct operated, without electrical position feedback, without/with integrated electronics (OBE)

Proportional pressure reducing valve, pilot operated, with inductive position transducer

Servo solenoid valves with positive overlap Position feedback (Lvdt DC/DC ±10 V)

4/3 proportional directional control valve, without position control, with on-board electronics (OBE)

Proportional pressure relief valve, pilot-operated, with anti-cavitation function, decreasing characteristic curve Type KBVS.2DB

Proportional pressure reducing valve, pilot operated

4/2 servo solenoid valves with positive overlap and position feedback (Lvdt AC/AC)

Servo solenoid valves with electrical position feedback (Lvdt AC/AC)

Servo solenoid valves with electrical position feedback (Lvdt DC/DC) (ruggedized design)

29 160/ Proportional Pressure Relief Valve Model DBE, (Series 5X) Ordering Code DBE 5X Y G24 1/ PSI (350 bar)

Proportional pressure reducing valve, pilot operated

RE / Central Hydraulics Valve LT43 for Tractors with Priority Function for Steering and Trailer Brake and Pilot Oil Valve.

Proportional pressure reducing valve, pilot operated. Type DRE(M) and DRE(M)E. Features. Contents. RE Edition: Replaces: 11.

3/2 directional spool valve, direct operated with solenoid actuation

Proportional flow control valve, with inductive position transducer

Servo directional valve of 4-way design Type 4WS.2E

Proportional pressure relief valve, pilot operated

Proportional pressure relief valve with linear curve (Lvdt AC/AC)

RC /

Flow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control

Servo solenoid valves with on-board electronics (OBE)

Proportional pressure relief valve

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8.

Servo solenoid valves with on-board electronics (OBE)

Proportional pressure reducing valve, pilot operated

Proportional pressure reducing valve, pilot operated

Proportional flow control valve, 2-way version

Internal gear pump Type PGH Fixed displacement

4/3 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

Proportional flow control valve with integrated pressure compensator Type KUDSR

2/2 directional seat valve, direct operated with solenoid actuation

Proportional pressure relief valve, directly operated, without/with integrated electronics (OBE)

2-way proportional throttle valve for block installation

Flow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control

Proportional pressure relief valve, pilot operated

Servo solenoid valves with positive overlap and on-board electronics

Servo solenoid valves with electrical position feedback (Lvdt DC/DC ±10 V)

Return line filter for direct tank mounting Type ABZFR

Proportional flow control valve. Type 2FRE. Features. Contents. RE Edition: Replaces: 02.07

Fixed displacement vane pumps Types PVV and PVQ

3-way servo solenoid valves, cartridge type, pilot operated, with inductive position transducer

Pressure relief valve, pilot operated

Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback

29 158/ Proportional Pressure Relief Valve Models DBE and ZDBE, Series 1X. Ordering code DBE 6 1X G24 1/ PSI (315 bar)

Proportional directional valves, pilot operated, with electrical position feedback and integrated electronics (OBE)

Proportional pressure reducing valve, 3-way variant, pilot operated

Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback

Servo solenoid valves with on-board electronics (OBE)

3-way Proportional pressure reducing valve, pilot operated

4/2 servo solenoid valves with positive overlap and position feedback (Lvdt AC/AC)

Hydraulic primary unit Type ABPAG

Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer

Servo solenoid valves with on-board electronics (OBE)

External gear pumps Type G2, Series 4X

Traction module (Flow divider) RTM

Flow sharing control block in mono block / sandwich plate design M6-15

4/3-way high response directional control valve pilot operated with electrical feedback and integrated electronics (OBE)

Directional servo-valve of 4-way design

Flow sharing control block in mono block / sandwich plate design M6-22

Reservoir oil filler/breather

Check valve, pilot operated

Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated

4-way directional servo-valve

Directional servo-valve in 4-way design

Flow sharing control block in sandwich plate design M7-25

RE / /09.97

4/3-way servo solenoid directional control valves, pilot operated, with electrical position feedback (Lvdt DC/DC ±10V)

LUDV control block of sandwich plate design

Clamping and drive module

2-way flow control valve

Proportional pressure reducing valve, in 3-way version

Proportional flow control valve 2-way versiontype 2FRE 6...RC

Proportional pressure reducing valve

Transcription:

RE 58 38/4.99 Proportional pressure reducing valve Type FTDRE 4 K Nominal size 4 Series 1X Maximum control pressure 18 / 3 bar Maximum operating pressure 2 bar Flow 5 L/min at p = 7 bar F9513 Type FTDRE 4 K1X/3 C4V Overview of contents Symbol Description Page Ordering details 1 Symbol 1 Function, section 2 Technical data 2 and 3 Characteristic curves 4 Unit dimensions 5 P T Ordering details FTDRE 4 K 1X/ V * Proportional pressure reducing valve, non standardised design, electrical actuation Nominal size 4 = 4 Cartridge valve = K Series to 19 = 1X ( to 19: unchanged installation and connection dimensions) Max. settable pressure at port 18 bar = 18 3 bar = 3 Solenoid wet (switches in the pressure fluid) Nominal voltage 12 V Nominal voltage 24 V = = G12 = G24 C2 = C4 = 1) V = Further details in clear text (special versions on request) FKM seals (for compatible pressure fluids see technical data on page 2) Electrical connections Terminal with plug type SS 2P (ITT-Cannon), with hand override Plug, 2-pin, type Junior Timer (MP) 1) The hand override can only be actuated after the plug has been removed. FTDRE 4 K 1/6

Function The proportional pressure reducing valve type FTDRE 4 K reduces the pressure in port in proportion to the solenoid current. It operates virtually independently from the pressure in port P. The valve is suitable for the control of directional valves and hydraulic cylinders, particularly those in the mobile and automotive technology sectors. The hydraulic pressure in port acts on the spool (1) against the solenoid force. With the proportional solenoid (2) de-energised port P is closed and port is connected to tank T. The valve can be supplied with the nominal voltages of 12 V and 24 V. Operation is only permissible with a suitable amplifier (see technical data).! Note! For mains operation an isolating transformer with separated windings is required. For optimum operation the solenoid must be filled with the pressure fluid (also see technical data "Installation"). T 2 1 P Technical data (for applications outside these parameters please consult us!) General Weight kg approx..19 Installation optional, preferably with the electrical connection hanging downwards, (when the valve is horizontally mounted or if the electrical connection is pointing upwards then a minimum back pressure p T has to be created to ensure that the valve stays full of oil) mbient temperature range C 3 to + 12 Solenoid surface protection coating to DIN 5 961-Fe/Zn C Salt spray test to DIN 5 21 h 144 Rexroth Hydraulics 2/6 FTDRE 4 K

Technical data (for applications outside these parameters please consult us!) Hydraulic Control pressure (p ) at port see tolerance band on page 4 Input pressure (p P ) bar 2 Back pressure (pressure p T at port T) bar zero pressure (valve pressure tight up to 3 bar) attention: back pressure p T increases the set pressure p, even with current I = Flow details valid for BP Dexron II and + 8 C Flow ( p = 7 bar) L/min 5 Max. leakage flow at port T at p P = 2 bar and control current I = cm 3 /min 15 Max. control flow at p P = 2 bar, q V = and control current I = I max cm 3 /min 4 Stepped response with control current alteration t on max. 4 ms (for test set-up see page 3) t off max. 2 ms Pressure in bar p 18 % 95% % 5% t on t off t Control current in % Pressure fluid mineral oils to DIN 51 524, TF Dexron II, Fiat Tutela Multi F Pressure fluid temperature range C 3 to + 8 Degree of contamination maximum permissible degree of contamination of the pressure fluid is to NS 1638 class 9. We, therefore, recommend a filter with a minimum retention rate of ß 75. Electrical Voltage type DC mplifier nominal voltage V 12 24 Max. control current 1.8.8 Coil resistance (2 C) Ω 2.4 12 Duty (with amplifier) % Electrical connection see ordering details Protection to DIN 4 5, part 9 Solenoid IP 6K5 Electrical connection IP 6K5 Chopper frequency (recommended) 1) Hz 2 Possible control electronics in plug-in amplifier housing 2) FTE 11 (see RE 58 11); FTE 12 (see RE 58 12); (separate order) FTE 15 (see RE 58 15); FTE 16 (see RE 58 16); FTE 18 (see RE 58 18); FTE 19 (see RE 58 19) Possible control electronics as carrier rail module 2) VT 18, VT 19, VT 117 and VT 118 (see RE 29 762) (separate order) Power supply modules: VT 15 (12 V, see RE 29 732) VT 16 (24 V, see RE 29 729) 1) The chopper frequency must be suited to the application. Please take the application temperature into account. 2) The above mentioned control electronics type FTE can be optionally operated with 12 V and 24 V. Thus the 12 V valve type may always be used independent from the supply voltage. When using the above mentioned control electronics types VT the voltage must be considered. Note: For technical details (e.g. frequency response) on request. FTDRE 4 K 3/6 Rexroth Hydraulics

Characteristic curves with tolerance band Pressure stage 18 bar 22,5 2 2,2 bar Set pressure p at port in bar 17,5 15 12,5 7,5 5 6, bar 18,2 bar 2,5 4, bar (12 V),,2,4,6,8 1, 1,2 1,4 1,6 1,8, (24 V),36,8 Pressure stage 3 bar 32,5 3 27,5 Control current in 32 bar 3 bar 2, Set pressure p at port in bar 25 22,5 2 17,5 15 12,5 7,5 8,5 bar 5 5,3 bar 2,5 (12 V),,2,4,6,8 1, 1,2 1,4 1,6 1,8 (24 V),,36,8 Control current in 2, mplifier: FTE 11 Chopper frequency: f C = 2 Hz Installation position during testing: horizontal Inlet pressure: p P = 5 bar Test medium: BP Dexron II Test temperature: ϑ = 5 C Dead volumn at port : V = 135 ml Hysteresis: max. 5 % Rexroth Hydraulics 4/6 FTDRE 4 K

Unit dimensions (Dimensions in mm) Ø 14 17,5 1 52 285 ± 6 Ø 26,5 ±,3 1 8 +1 2 4 13,2 ±,3 47,5 ±,5 3 47,5 ±,5 8 5 4 Ø 15 f7 9,5 22,75 ±,3 37 ±,3 max. 4 7 Ø 16 f7 M22 x 1,5 Ø 25 3 Ø 4 3 Ø 28,6 2,2 SW 27 1 Version C4 2-pin plug, type Junior Timer (MP) 2 Version C2 Terminal (WG 18) with 2-pin plug, type SS 2P (ITT-Cannon) 3 Hand override With version C4 the hand override can only be actuated after the plug has been removed. 4 O-ring 12 x 1.5 (FKM) 5 O-ring 12.42 x 1.78 (FKM) 6 O-ring 19.4 x 2.1 (FKM) 7 Back-up ring 16 x 13.4 x 1 8 Back-up ring 15 x 12.8 x 1 9 Minimum depth of fit Spanner flat 27/F, M =12Nm+5Nm 9 45 ±5 15 ±1 R,1 +,1 35,5 max 29,3 min Ø 4 min 22,6 17,5 +,2 max 14,8 min Ø 4 min 9,7 2,4 +,1 T,5 min. Ø 26 Ø 23,8 +,1 M22 x 1,5 Ø 16 H8 Ø 15 H8,2 15 15 max,5 15 23,5,5 3 +,2 min 4,2 P Required surface finish in the areas of fit and chamfer R max 8,1 +,4 min Ø 4 9 FTDRE 4 K 5/6 Rexroth Hydraulics

Notes Mannesmann Rexroth G Rexroth Hydraulics D-97813 Lohr am Main Jahnstraße 3-5 D-97816 Lohr am Main Telefon 93 52 / 18- Telefax 93 52 / 18-23 58 Telex 6 89 418- Mannesmann Rexroth Limited Cromwell Road, St Neots, Cambs, PE19 2ES Tel: 14 8/22 32 56 Fax: 14 8/21 9 52 E-mail: info@rexroth.co.uk The specified data is for product description purposes only and may not be deemed to be guaranteed unless expressly confirmed in the contract. ll rights reserved Subject to revision 6/6 FTDRE 4 K