TS9356 PKT 90/119. Surface applied door closer. Installation instructions: Pocket door track mount in 90 /119 pocket (Closer on wall)

Similar documents
TS93 PT/PTH. Surface applied door closer. Installation instructions: Push side track mount with dead stop (PT) Optional hold open (PTH)

TS93 EMF T/PT/TDE. Surface applied door closer

Surface Applied Door Closers DORMA TS93

Surface Applied Door Closers DORMA TS93

Installation Instructions Series 78-B/FHA Hold Open

DC3210 Series. Multi-Sized 1 thru 6 DEEP REVEAL APPLICATION WITH M103 OPTION(615F59 CLAMP KIT) Recommended Closer Size

ASSA ABLOY Universal Door Closers

These door closers should NOT be installed on the exposed side (weather side) of exterior doors.

ED900. Low energy operator. Installation instructions: T/slide channel/pull arm mounting

TS93. Surface Applied Door Closers

ASSA ABLOY Universal Door Closers with Heavy Duty Spring Stop Parallel Arms

ASSA ABLOY MPI (Infinite Hold Open Range) Support Unit Models. Multi-Point Electromechanical Overhead Concealed Closer Holder Releasing Device

Hinge (Pull) Side Door Application DC6230 Series Multi-Sized 1 thru 6 DC6430 Series Half-Size 1 thru 6. Door Mounted DC6230 & DC6430

Series 9540 J9540. Installation Instructions Multi-Sized 1 to 6 Non-Hold Open. Regular Arm Applications. Parallel Arm Applications

Surface Applied Door Closer and Coordinator System DORMA GSR

U1500. Surface Applied Door Closers

Floor-Concealed Door Closers DORMA BTS75V

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

ASSA ABLOY Series Multi-Point Hold Open Installation and Instruction Manual

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

5600 Series Power Operator Installation and Instruction Manual

Floor-Concealed Door Closers DORMA BTS80

Power drill Center punch Wire stripper

D O O R C L O S E R S

CONCEALED CLOSER SERIES

D o o r C l o s e r s

7100SZ Series SafeZone Installation and Instruction Manual

RTS88. Overhead Concealed Door Closer

Surface Applied Door Closers

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

4000 Series mounted closers

Installation Instructions CAUTION

HIGH SECURITY CLOSERS SERIES

CONCEALED CLOSER SERIES

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

HIGH SECURITY SERIES

5700 Series Power Operator Hinge (Pull) Side Mount Installation and Instruction ASSA Manual ABLOY

*24771* 4040SE DE Sentronic. 1 Voltage. 7 Regulation. 2 Track. 8 Door Closer Cover. 3 Spring Power. 4 Arm Installation. 5 Arm Screw.

High Security Closers Series

Installation Instructions (07-08) CAUTION

DOUBLE LEVER ARM DOUBLE LEVER ARM SINGLE LEVER ARM 5010 SINGLE LEVER ARM

5300 Series. Architectural Commercial Door Control

ROFU TJ 152-A. Y ALE SECURITY GROUP 50BC Series Door Closer. 50BC Series Door Closers. Sizing Chart for Installations. Ordering Information

MOUNTING FINISH COVER CYLINDER **ARM FUNCTION REGULAR (DOUBLE) DESIGNER METAL NON-HANDED NON-SIZED

Floor Spring Accessories DORMA. BTS Accessories

Holder/Release Devices with Integral Door Closers DORMA EMF/ EMR

5700 Series Power Operator Stop (Push) Side Mount Installation and Instruction

HOW TO TELL HAND OF DOOR:

5300 Series 5300 SERIES

BTS Accessories. Floor Spring Accessories

Surface Applied Door Closers

INSTALLATION EML375. Pre-Installation Instructions. Electromagnetic Locks

SWING DOOR SOFT ENCLOSURE (part# 16733)

High Security Closers Series

Floating Headers - 4-1/8, 4-1/2, 6. with RTS88 and PT21 for double doors ONLY. Installation instructions

LCN 4010T SERIES HINGE (PULL) SIDE

5300 Series. Architectural Door Control

KEANE MONROE a member of the record group

4040XP Series Door controls

5100 Series. Architectural Door Control

D-1610/D-1611 SERIES: DOOR CLOSERS. D-1610/D-1611 Series. Door Closers. Trusted experts. Proven reliability. Simply STANLEY.

INSTALLATION DESCRIPTION

PFT-61 LH & RH Sidelite Transom Patch Fitting w/stop & Fin Installation Instructions

PULL SIDE MOUNTED PUSH SIDE MOUNTED DOUBLE LEVER ARM LEVER ARM P DOUBLE LEVER ARM SINGLE LEVER ARM 4110T 4210T*

Concealed overhead closer for high-end applications DOOR CLOSERS CATALOG

7100 Series. Heavy Duty Architectural Door Control

Surface Applied Door Closers

Surface Applied Door Closers DORMA 7400

*24213* 4040-SE Sentronic. 1 Voltage. 6 Adjusting Hold-Open Door Position. 7 Regulation. 2 Tracking. 8 Door Closer Cover.

4040XPT Series Door controls

*24828* 1 Installation. Left Hand Shown, Right Hand Opposite. Customer Service

Door Controls DOOR CLOSERS

* * Maintenance Kit

Headline. Overhead Door Holders/Stops

3100 Series. Commercial Door Control

*4110 HCUSH mount shown

5200 Series

Door Closer DORMA TS72 VBC

Connected To Control Box Series. Closer. Set Screw. Arm Screw. Right Hand Shown. 1/8" I.D. Air Inlet Tubing Connected To Control Box

7100 Series. Heavy Duty Architectural Door Control

DC5000 Series. Cam Action Door Closer

*24191* 4040SEL Sentronic. 35 ft-lbs 48 N-m 62 N. Installation CAUTION. Customer Service. Installation Instructions

MODEL 3002xTJ32 ELECTROMAGNETIC LOCK INSTALLATION INSTRUCTIONS

Closer with traditional styling for low to moderate traffic openings 78-B/F DOOR CLOSER CATALOG

PUSH SIDE M O U N T E D PULL SIDE M O U N T E D D O U B L E LEVER ARM LEVER ARM P D O U B L E LEVER ARM S I N G L E LEVER ARM

3100 Series. Commercial Door Control

Surface Applied Door Closers

Door Closer DORMA TS 72

Pivot Sets and Components DORMA LM

DORMA INTERIOR. DORMA PURE FAMELESS SLIDING Glass Wall Systems

Self-Stabilizing Hand Truck Table of Contents:

Universal Storage - Drawer and Overfile Stack Units

Crossbar Devices. RDX-2 Part No US32D List Price DC

Overhead door holders/ stops

WARNING NOTICE CAUTION ASSEMBLY INSTRUCTIONS

An ASSA ABLOY Group brand. 400/4400 Series. Institutional Door Closer

JACKSON CORPORATION Series

PFT-71 Transom Connector w/fin Installation Instructions

SERVICE PARTS LIST SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS METAL CUTTING SAW SERIAL NUMBER

78-B/F Series. Traditional Door Closers

Transcription:

TS96 PKT 90/9 Surface applied door closer Installation instructions: Pocket door track mount in 90 /9 pocket (Closer on wall)

TABLE OF CONTENTS Closer overall Technical specifications Door templates Closer setup Exploded parts list Handing of the door A. Installing the surface closer Installing the backplate Installing the surface closer 4 B. Adjustments Adjusting the closing speeds Adjusting the spring force 6 C. Installing the closer cover Installing the cover 6 Technical specifications Templates Contents Note: Refer to the included drawing for pull side door closer back plate and track mount templating. Size selection chart Closer Door Width Range Maximum Weight TS96 PKT 90/00 '-8" to 4'" 0 lb Note. Drawing is not to scale.. Dimensions are in inches/[mm].. Right hand door is shown. 4. Caution: sex nuts are required for attachment of components to unreinforced doors and to wood or plastic faced composite type fire doors, unless an alternative method is identified in the individual door manufacturer's listings.. Template is for 4-/" x 4-/" butt hinges and /4" offset pivots. 6. Maximum degree of opening is 9. 7. Minimum door width is ". 8. Adjust closer spring tension for proper closing and latching of door. 9. Adequate reinforcement by others required to install track in pocket. 0. Pocket depth is measured from the pull side face of the door at maximum opening.. Requires DORMA EM04 electromagnetic door holder. Use closer body style "B" for this installation.. Arrows on closer mounting plate point upward. DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: 800--848 E-mail: dormaarchitectural@dorma.com 088009 06/4 Reamstown, PA 767 Fax: 800-74-974 Subject to change without notice

TS96 PKT 90/9 (closer on wall) Closer setup Follow included template to properly prepare door and frame for all accessories of the closer installation. Know the swing of the door which is being installed prior to installation. Make sure door efficiently operates prior to installing closer. Verify closer spring size prior to installation. See "Size selection chart" on page. The surface closer is comprised of the following components.. Closer body. Main arm. Track assembly 4. Pinion. Cover and end caps 6. Closing/sweep speed adjustment 7. Latch speed adjustment 8. Backcheck adjustment 9. Delayed action adjustment 0. Backplate 0 8 4 7 6 9 Handing of the door Left hand door (LH) Interior side of door Right hand door (RH) Hinge Hinge Left hand reverse door (LHR) Exterior side of door Right hand reverse door (RHR) DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: 800--848 E-mail: dormaarchitectural@dorma.com 088009 06/4 Reamstown, PA 767 Fax: 800-74-974 Subject to change without notice

TS96 PKT 90/9 (closer on wall) A. Installing the surface closer Tools recommended Drill Bits Metal: No. & 0- Tap Wood: /8" # Phillips screwdriver M. & M Hex key Installing the back plate Reference template 088009. Attach the back plate to the installing surface using the four screws [0- machine screws or #0 wood screws] provided with the surface closer. NOTE: Make sure arrows on plate point upward. Installing the surface closer Toward the hinge NOTE: Orient pinion () closest to hinge.. Secure the closer body () to the plate using the four Mx47mm flathead Phillips screws () provided with the plate. A B C A. Position the components inside the track channel ().. Attach the track channel to the door through the end blocks with two flat head Phillips screws (). A. End block B. Track channel C. Slide shoe Right hand door 4 DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: 800--848 E-mail: dormaarchitectural@dorma.com 088009 06/4 Reamstown, PA 767 Fax: 800-74-974 Subject to change without notice

TS96 PKT 90/9 (closer on wall) Right hand door 4 4. Align the arm () with the slide shoe of the track channel. 4. Secure with one M8xmm shoulder bolt () using an M hex key.. With the door closed and using an adjustable wrench (looking up at the bottom of the closer): Left hand door - turn the bottom pinion clockwise approximately. Right hand door - turn the bottom pinion counterclockwise approximately.. Attach the main arm () to the top pinion with an M6x0 socket head cap screw () using an M hex key. Be sure that the door is fully closed during application. Right hand door B. Adjustments Set closer spring size prior to making any closing speed adjustments. Do not back valves out beyond closer casting. Maximum opening angle is 9º. Door should close in to 6 seconds from 90º. Do not close valves completely. Adjusting the closing speeds: sweep, latch, backcheck and delayed action [Sweep] [Latch] [Backcheck] Latch Sweep 4 [Delayed action] Backcheck Decrease Increase Sweep & Latch Delayed action Increase Decrease Backcheck & Delayed actions. Adjust the sweep speed () for the area from 70-0 Increase sweep speed: Turn valve counter-clockwise Decrease sweep speed: Turn valve clockwise.. Adjust the latch speed () for the area from 7-0. Increase latch speed: Turn valve counter-clockwise Decrease latch speed: Turn valve clockwise.. Adjust the backcheck (). Increase resistance: Turn valve clockwise Decrease resistance: Turn valve counter-clockwise..4 Adjust the delayed action (4) for the area from 9-70. Increase delayed action: Turn valve clockwise Decrease delayed action: Turn valve counter-clockwise DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: 800--848 E-mail: dormaarchitectural@dorma.com 088009 06/4 Reamstown, PA 767 Fax: 800-74-974 Subject to change without notice

TS96 PKT 90/9 (closer on wall) Adjusting the spring force Increase Decrease DOOR WIDTH FULL TURNS OF CLOSER INT. SPRING ADJUSTER SIZE TS96 4' 0 4'6" + 6 TS96 NOTE: Supplied with a size 6 spring setting. Increase force: turn clockwise 6 times (max) C. Installing the closer cover Installing the cover 4. Snap both end covers () into place.. Remove the un-needed tab (), and snap the closer body cover () into place.. Secure with a 4-40 Phillips pan head screw (4). 6 DORMA USA, Inc. Dorma Drive, Drawer AC Toll-Free: 800--848 E-mail: dormaarchitectural@dorma.com 088009 06/4 Reamstown, PA 767 Fax: 800-74-974 Subject to change without notice