Similar documents
Safety disconnect. switch is optional. Belt drive with adjustable motor pulley provides flexibility to match operating requirements.

Type VA Vanax Fans. Models VA, VAD, & VAB

Centrifugal Upblast Power Roof Ventilators

Types RE & RES- Recirculating Roof Ventilators

Centrifugal Filtered Supply Fans

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

MODELS CSF & LSF BELT DRIVE CENTRIFUGAL FILTERED SUPPLY FANS

forward curved inline duct blowers

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN

Filtered Kitchen Supply Packaged Ventilator

DESIGN GUIDELINES FANS PAGE 1 of 7

MODELS HREB-C & HRED-C HOODED PROPELLER ROOF EXHAUST FANS

MODELS HRSB & HRSD HOODED PROPELLER ROOF SUPPLY FANS

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

Centrifugal Filtered Supply Roof Blowers

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN

Industry best 5 year fan housing warranty, 1 year motor warranty

Inline and Roof Mounted Fans

MODELS UBB & UBX UPBLAST PROPELLER ROOF EXHAUSTERS BELT AND DIRECT DRIVE

Centrifugal Spun Aluminum Products

MODEL LUBK (Belt Drive) UPBLAST PROPELLER ROOF EXHAUSTERS

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN

Twin City Fan & Blower

SQUARE INLINE CENTRIFUGAL FANS

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

MODEL UBSRD REMOTE DRIVE UPBLAST PROPELLER ROOF EXHAUSTER

Industry best 5 year fan housing warranty, 1 year motor warranty

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

Direct Gas-Fired Heating

Low Silhouette Power Roof Ventilator Propeller

FILTERED SUPPLY CENTRIFUGAL Belt Drive

Upblast Power Roof Ventilators Types J, JTE, JT, HSE, & HS

SECTION AXIAL HVAC FANS

Propeller Hooded Roof Fans

Square Inline Fans with Multi-Directional Discharge

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VQBL

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

SECTION HVAC POWER VENTILATORS

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS

Utility Sets Standard Design Features Standard design features common to all Class I and Class II fans

K SERIES SIDEWALL PROPELLER FANS

Tube Axial Fan Page Specifications & Dimension Data Performance Data

Tamper Proof Downblast Centrifugal Exhaust Ventilators Page

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB

TU-WAY ROOF VENTILATORS

"SPOAU" DEDICATED 100% OUTSIDE AIR UNITS Self Contained Single Package or Split System Units

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct

Centrifugal Spun Aluminum Products

Centrifugal Spun Aluminum Products

DIrect drive exhaust & supply panel fans

Bulletin DXA08 DOMEX AXIAL. Models: DAS, DAE Roof Ventilators Direct Drive MOVING YOUR WAY

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE

SECTION CENTRIFUGAL HVAC FANS

BCFS Belt Driven Centrifugal Filtered Supply Fans

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV

Direct Drive Centrifugal Exhausters Low Profile Roof/Sidewall and Roof Downblast

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Downblast Exhaust Fan Belt Driven for Roof & Wall Mounting

EXHAUST FANS CUD & CUB UPBLAST FANS

PRODUCT FEATURES. BEARING LIFE All bearings are designed for L50 life of 200,000 hours.

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.

The Industrial Choice. PROPELLER WALL FANS DIRECT DRIVE & BELT DRIVEN. Models BSDDP / BSBP

K SERIES DIRECT DRIVE SIDEWALL PROPELLER FANS

Fixed Pitch Vane Axial Fan

Twin City Fan & Blower

sidewall propeller fans L 1.07 models lc, l2 & l3 january 2007 belt drive - exhaust & supply three levels of construction

MODEL TDB TUBEAXIAL INLINE BELT DRIVEN DUCT FAN

Tube Axial Inline Fans

MODEL VBO-HV & VBO UPBLAST PROPELLER ROOF FANS

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK

HA/HAB Fiberglass Wall Mount Ventilators

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK

FADE SERIES. Typical Specifications for Model FADE Sidewall Propeller Fans Sidewall propeller fans shall be of the direct driven type.

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

MODEL CWD DIRECT DRIVE CENTRIFUGAL SIDEWALL EXHAUSTER

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

Industry best 5 year fan housing warranty, 1 year motor warranty

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK

TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

TURNING AIR INTO SOLUTIONS. LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. LHD/LHB (Exhaust/Supply) LHDF/LHBF (Filtered Supply)

FILTERED AIR SUPPLY FANS. Direct Drive & Belt Driven Models FSR / FSWD / FSWB / FF. Model FSWB Wall Mounted. Model FSR Roof Mounted

First Inline fan in the industry to be UL/cUL Listed Power Ventilator for Smoke Control Systems

The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS. Macheta Airfoil Design. Model BD40C

VDBA INDOOR SINGLE & TWIN LINE DUCT BLOWERS

READ AND SAVE THESE INSTRUCTIONS. High Velocity Restaurant-Duty Utility Set Belt Driven for Roof Mounting

FIXED PITCH PROPELLER FANS

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

A Fläkt Woods Company. Model PFB Panel Exhaust Fans 24" 72" Diameter Bulletin PF-1410 July 2003

Bulletin REXJR05 CENTREX REX JR. Model: REXJR Direct Drive Centrifugal Inline Fans

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data

User s Manual and Operating Instructions

& 12" 96" / TABD CATALOG

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven

CONSTRUCTION FEATURES

Propeller Upblast Roof Fans

Transcription:

INDUSTRIES AMERICAN COOLAIR CORPORATION Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS

CFS Centrifugal Filtered Supply Fans Applications The CFS Centrifugal Filtered supply fans with four (4) side inlets are designed for roof mounting on curbs to provide make-up filtered air to general ventilation systems. Applications include a variety of commercial and industrial facilities as well as commercial and industrial kitchens. Construction Construction of the CFS power roof ventilators is mill galvanized steel throughout the unit. The blower has a DIDW centrifugal wheel with forward curved blades finished in a matte zinc coating. The blower housing is constructed of galvanized steel. The blower features sealed and permanently lubricated ball bearings suitable for operation from -65 degrees to +50 degrees F (check motor capability). The blower is mounted to the fan housing using rubber isolation grommets. Filters are aluminum mesh, cleanable and held in place by a u-channel frame. UL705 E39944 Guide Specifications Type CFS ventilators are Listed by Underwriters Laboratory Inc. to US and Canadian safety standards. American Coolair Corporation, ILG Industries Division certifies that the Type CFS units shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication and comply with the requirements of the AMCA Certified Ratings Program. Access to the fan, motor, drive and filters is accomplished by removal of the top utilizing four (4) thumb screws. A factory wired disconnect switch is an available option. Drive Mechanism CFS models have a V-belt drive with adjustable cast iron motor pulley for adjusting fan operating speed. Drive shaft is turned, ground and polished. Motor support is adjustable for proper belt tensioning. Motors NEMA standard open drip proof motors are prelubricated and located in the air stream. Other motors may be available. All motor brands are recognized and serviced nationwide. Motor enclosure required may affect UL Listing. Filtered supply fans shall be of the CFS centrifugal type as manufactured by ILG Industries of American Coolair Corporation (individual models to be listed in fan schedule). Units shall bear the AMCA Certified Ratings Seal for air performance. Housing and frame of the fan are to be galvanized steel. The top of the unit is to be removable for access to the inside fan components, filters and drive. The blower is to be mounted to the fan housing using rubber isolation grommets. Drive mechanism shall incorporate a V-belt drive with cast iron motor pulley. The centrifugal wheel shall be heavy gauge zinc-coated steel with forward-curved blades. Motor shall be open drip-proof construction, NEMA design B with minimum service factor of.5. Adjustable motor pulley shall be provided to allow for field adjustment and system balance. Motor shall be mounted on an adjustable steel mounting bracket. (Mounted and wired disconnect switch, backdraft damper, epoxy coating and other accessories shall be listed in the fan schedule.)

CFS 9 Performance Data /4 L /4 H /3 700 800 900 000 00 00 300 400 500 600 700 800 900 000 / 00 00 300 400 0.00.5.50.375.500.65.750.00 RPM 45 556 B 0.04 0.07 RPM 44 573 B 0.05 0.09 RPM 460 589 688 B 0.07 0.0 0.3 RPM 48 603 705 787 B 0.08 0. 0.6 0.8 RPM 508 68 7 804 877 B 0.0 0.4 0.9 0.3 0.5 RPM 437 536 635 735 8 894 B 0.09 0.3 0.6 0. 0.7 0.30 RPM 473 566 656 749 836 9 977 B 0. 0.5 0.9 0.4 0.3 0.35 0.39 RPM 50 598 678 765 850 97 994 B 0.5 0.9 0. 0.7 0.34 0.40 0.45 0.5 RPM 546 630 703 784 865 94 0 8 B 0.8 0.3 0.6 0.3 0.37 0.44 0.5 0.59 RPM 583 663 730 805 88 955 05 45 B 0. 0.7 0.3 0.44 0.4 0.48 0.56 0.68 RPM 69 697 759 87 899 970 039 6 B 0.6 0.3 0.36 0.49 0.46 0.53 0.6 0.76 RPM 655 730 789 85 99 987 053 B 0.3 0.38 0.4 0.46 0.5 0.59 0.66 RPM 69 764 80 878 94 005 069 B 0.37 0.44 0.48 0.5 0.58 0.65 0.7 RPM 78 798 85 906 964 05 086 B 0.43 0.5 0.55 0.59 0.65 0.7 0.79 RPM 765 83 884 935 989 046 04 B 0.50 0.58 0.6 0.67 0.7 0.79 0.86 RPM 80 866 97 965 06 B 0.57 0.66 0.7 0.75 0.8 RPM 837 900 950 996 B 0.65 0.75 0.80 0.85 RPM 874 935 B 0.74 0.84 ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 3

CFS 0 Performance Data /4 L /4 H /3 / / 600 800 000 00 400 600 800 000 00 400 600 800 3000 300 0.00.5.50.375.500.65.750.00.5 RPM 355 B 0.03 RPM 383 499 B 0.05 0.08 RPM 47 5 6 700 B 0.08 0. 0.5 0.0 RPM 340 454 55 635 7 785 857 B 0.07 0. 0.5 0.0 0.4 0.9 0.38 RPM 397 495 586 665 735 800 864 B 0. 0.6 0. 0.6 0.30 0.35 0.4 RPM 453 539 63 698 765 86 885 997 B 0.7 0. 0.8 0.33 0.39 0.44 0.50 0.6 RPM 50 586 663 734 798 857 9 06 5 B 0.5 0.9 0.36 0.4 0.48 0.55 0.6 0.73 0.87 RPM 567 635 704 77 833 890 943 04 34 B 0.34 0.39 0.45 0.53 0.60 0.67 0.74 0.87.0 RPM 63 685 748 8 870 95 976 07 60 B 0.45 0.50 0.57 0.66 0.74 0.8 0.88.03.9 RPM 680 737 794 85 908 96 0 04 89 B 0.59 0.64 0.7 0.80 0.89 0.97.06..39 RPM 736 789 84 895 948 999 047 37 B 0.74 0.80 0.88 0.96.06.6.5.4 RPM 793 84 89 940 990 038 085 7 B 0.93 0.99.07.5.6.36.47.68 RPM 850 895 94 987 033 079 4 B.5..9.38.48.59.7 RPM 906 949 99 035 078 B.39.46.54.63.73 4 ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

CFS Performance Data /4 /3 / / 00 400 600 800 000 00 400 600 800 3000 300 3400 3600 3800 4000 400 4400 4600 4800 0.00.5.50.375.500.65.750.00.5.50 RPM 453 B 0.0 RPM 466 55 B 0.3 0.6 RPM 397 486 563 635 B 0. 0.6 0. 0.4 RPM 4 509 579 647 7 B 0.6 0. 0.5 0.30 0.35 RPM 450 53 599 66 7 780 B 0.0 0.6 0.3 0.36 0.4 0.47 RPM 40 480 555 63 680 736 79 B 0.0 0.6 0.3 0.38 0.43 0.49 0.55 RPM 48 5 578 646 70 754 806 906 B 0.6 0.3 0.38 0.45 0.5 0.58 0.64 0.77 RPM 474 544 604 669 76 776 83 98 008 B 0.33 0.40 0.46 0.54 0.6 0.68 0.74 0.88.03 RPM 5 576 63 69 749 799 844 933 09 0 B 0.4 0.48 0.55 0.63 0.7 0.79 0.86.0.5.9 RPM 547 609 66 75 77 8 867 950 033 B 0.50 0.58 0.66 0.73 0.8 0.90 0.98.4.30.45 RPM 583 643 69 74 794 845 89 97 048 5 B 0.6 0.70 0.77 0.85 0.94.04.3.9.46.63 RPM 60 676 74 769 88 868 94 994 067 40 B 0.73 0.83 0.9 0.99.08.8.8.46.63.8 RPM 656 70 756 799 843 89 937 07 088 57 B 0.87 0.97.06.5.3.34.45.64.83.0 RPM 693 744 789 89 87 94 959 04 76 B.0.3.3.3.4.5.6.84.04.3 RPM 79 778 8 86 899 940 98 064 34 B.9.30.4.5.60.7.8.05.6 RPM 766 83 854 89 99 966 006 086 B.38.50.6.7.8.9.03.7 RPM 80 847 888 94 960 995 03 B.58.7.83.93.04.5.6 RPM 838 88 9 957 99 B.8.94.07.8.9 RPM 875 97 B.06.0 ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 5

CFS 5 Performance Data /4 /3 / / 3 500 800 00 400 700 3000 3300 3600 3900 400 4500 4800 500 5400 5700 6000 6300 6600 0.00.5.50.375.500.65.750.00.5 RPM 68 B 0.08 RPM 83 B 0. RPM 30 377 B 0.5 0. RPM 70 35 39 454 B 0.6 0. 0.8 0.34 RPM 304 350 409 468 5 B 0.3 0.8 0.35 0.43 0.5 RPM 338 378 49 483 535 58 B 0.3 0.37 0.44 0.53 0.6 0.70 RPM 37 407 45 500 549 596 638 B 0.43 0.48 0.59 0.64 0.74 0.84 0.93 RPM 405 437 476 50 565 609 65 B 0.55 0.6 0.69 0.78 0.88 0.98.09 RPM 439 468 50 54 583 65 665 74 B 0.7 0.77 0.84 0.94.04.6.6.49 RPM 473 499 530 566 604 64 680 754 8 B 0.88 0.94.0..3.34.46.70.95 RPM 506 53 559 59 66 66 697 768 834 B.08.5.3.33.44.56.68.94.9 RPM 540 563 589 67 649 68 76 783 848 B.3.39.47.56.68.80.94..48 RPM 574 595 69 645 674 705 736 799 86 B.58.65.74.84.95.08..49.79 RPM 608 68 650 674 700 78 758 87 B.88.95.04.4.6.38.5.8 RPM 64 66 68 703 77 753 78 837 B.0.9.38.48.59.7.87 3.7 RPM 675 693 7 733 755 779 805 B.57.65.74.86.97 3.0 3.5 RPM 709 76 744 763 784 B.97 3.06 3.6 3.6 3.39 RPM 74 B 3.4 6 ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

CFS 8 Performance Data / 800 /3 300 / 3 5 3600 4000 4400 4800 500 5600 6000 6400 6800 700 7600 8000 8400 8800 900 0.00.5.50.375.500.65.750.00.5.50 RPM 99 360 45 B 0. 0.3 0.39 RPM 34 379 430 478 B 0.3 0.39 0.49 0.60 RPM 9 350 40 448 493 535 B 0.3 0.4 0.50 0.6 0.7 0.84 RPM 33 376 45 469 50 550 588 B 0.43 0.53 0.64 0.75 0.87.00.3 RPM 356 403 45 49 530 567 603 67 B 0.57 0.68 0.8 0.9.05.8.3.6 RPM 388 43 476 55 55 586 60 685 B 0.74 0.86.00.3.6.39.54.84 RPM 40 460 50 540 574 607 639 70 760 B 0.94.07..37.50.64.79..45 RPM 45 489 58 565 598 69 659 79 775 89 B.7.3.47.63.78.9.07.4.77 3.3 RPM 485 59 555 59 63 653 68 738 79 844 B.45.59.75.94.0.6.40.76 3.3 3.5 RPM 57 549 58 66 648 677 705 758 80 860 B.75.90.07.6.45.6.79 3.3 3.5 3.9 RPM 549 579 60 643 674 70 79 780 89 B.0.5.43.64.85 3.03 3. 3.57 3.94 RPM 58 609 639 669 699 78 754 80 850 B.50.65.84 3.04 3.6 3.49 3.68 4.03 4.44 RPM 64 640 668 697 75 753 779 86 B.93 3.0 3.9 3.5 3.73 3.97 4.8 4.57 RPM 646 67 697 74 75 779 804 85 B 3.4 3.59 3.79 4.0 4.6 4.5 4.73 5.6 RPM 678 70 77 75 779 805 830 B 3.95 4.4 4.35 4.56 4.87 5.09 5.34 RPM 7 733 757 78 806 83 B 4.56 4.73 4.95 5.8 5.44 5.7 RPM 743 765 787 B 5.0 5.40 5.6 ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 7

CFS and Roof Curb Dimensions D SQ. C B A SQ. K SQ. H O.D. 5/8 5/8 J I.D. / THICK INSULATION 8 STD. HEIGHT E SQ. F SQ. G SQ. Unit Ventilator Dimensions Roof Curb and Damper Dimensions Filters Size A B C D E F G H J K Qty Size 9-30 5 / 6 3/8 4 /4 4 / 3 /4 8 / 5 /4 36 / 4 6 X 5 5, 8 4 9 / 0 3/8 5 / 36 / 34 35 /4 40 / 37 /4 48 / 4 0 X 5 Dimensions in inches 8

SIS (Single Inlet) Centrifugal Filtered Supply Fans Applications The SIS Centrifugal Filtered supply fans with single side inlet are designed for roof mounting on curbs to provide make-up filtered air to general ventilation systems. Applications include a variety of commercial and industrial facilities as well as commercial and industrial kitchens. Construction Construction of the SIS power roof ventilators is mill galvanized steel throughout the unit. The blower has a DIDW centrifugal wheel with forward curved blades finished in a matte zinc coating. The blower housing is constructed of galvanized steel. The blower features sealed and permanently lubricated ball bearings suitable for operation from -65 degrees to +50 degrees F (check motor capability). The blower is mounted to the fan housing using rubber isolation grommets. Filters are aluminum mesh, cleanable and held in place by a u-channel frame. UL705 E39944 Guide Specifications Type SIS ventilators are Listed by Underwriters Laboratory Inc. to US and Canadian safety standards. American Coolair Corporation, ILG Industries Division certifies that the Type CFS units shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication and comply with the requirements of the AMCA Certified Ratings Program. Access to the fan, motor and drive is accomplished by removal of the top utilizing four (4) zinc coated, quick release snap latches. Access to the filters is accomplished by removal of the filter retainer, utilizing two () thumb screws. A factory wired disconnect switch is an available option. Drive Mechanism SIS models have a V-belt drive with adjustable cast iron motor pulley for adjusting fan operating speed. Drive shaft is turned, ground and polished. Motor support is adjustable for proper belt tensioning. Motors NEMA standard open drip proof motors are prelubricated and located in the air stream. Other motors may be available. All motor brands are recognized and serviced nationwide. Motor enclosure required may affect UL Listing. Single inlet filtered supply fans shall be of the SIS centrifugal type as manufactured by ILG Industries of American Coolair Corporation (individual models to be listed in fan schedule). Units shall bear the AMCA Certified Ratings Seal for air performance. Housing and frame of the fan are to be galvanized steel. The top of the unit is to be removable for access to the inside fan components and drive. The blower is to be mounted to the fan housing using rubber isolation grommets. Drive mechanism shall incorporate a V-belt drive with cast iron motor pulley. The centrifugal wheel shall be heavy gauge zinc-coated steel with forward-curved blades. Motor shall be open drip-proof construction, NEMA design B with minimum service factor of.5. Adjustable motor pulley shall be provided to allow for field adjustment and system balance. Motor shall be mounted on an adjustable steel mounting bracket. (Mounted and wired disconnect switch, backdraft damper, epoxy coating and other accessories shall be listed in the fan schedule.) 9

SIS 9 Performance Data /4 L /4 H /3 / 700 800 900 000 00 00 300 400 500 600 700 800 900 000 00 00 300 0.00.5.50.375.500.65.750.00 RPM 459 B 0.05 RPM 479 B 0.06 RPM 5 B 0.08 RPM 49 548 650 B 0.07 0. 0.4 RPM 47 583 668 776 B 0.09 0.4 0.6 0. RPM 55 68 699 79 879 B 0. 0.7 0.0 0.5 0.3 RPM 558 653 734 807 90 97 B 0.5 0. 0.5 0.8 0.36 0.40 RPM 60 688 770 833 97 997 058 B 0.9 0.5 0.30 0.3 0.39 0.47 0.5 RPM 644 74 805 866 93 06 084 84 B 0.4 0.30 0.36 0.39 0.43 0.5 0.59 0.65 RPM 686 76 840 90 957 09 06 B 0.9 0.35 0.4 0.46 0.48 0.56 0.66 RPM 79 799 875 937 989 047 B 0.34 0.4 0.49 0.54 0.57 0.6 0.7 RPM 77 837 909 973 04 074 34 B 0.4 0.47 0.56 0.63 0.66 0.69 0.76 RPM 85 877 944 008 060 06 56 B 0.48 0.55 0.64 0.7 0.76 0.79 0.83 RPM 858 96 980 043 B 0.56 0.63 0.7 0.8 RPM 90 956 06 B 0.65 0.7 0.8 RPM 944 996 B 0.75 0.8 RPM 987 B 0.85 0 ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

SIS 0 Performance Data /4 L /4 H /3 / / 800 000 00 400 600 800 000 00 400 600 800 3000 300 0.00.5.50.375.500.65.750.00.5 RPM 403 5 B 0.04 0.07 RPM 445 546 64 74 B 0.07 0.0 0.3 0.6 RPM 388 485 584 665 745 88 B 0.08 0.0 0.4 0.7 0. 0.5 RPM 453 59 66 70 770 839 905 B 0. 0.5 0.0 0.3 0.7 0.3 0.36 RPM 57 580 666 743 806 866 97 043 47 B 0.8 0. 0.6 0.3 0.35 0.39 0.44 0.54 0.66 RPM 58 635 708 764 848 904 957 064 67 B 0.6 0.8 0.33 0.40 0.45 0.50 0.54 0.64 0.76 RPM 646 693 753 84 889 945 996 09 88 B 0.36 0.38 0.4 0.49 0.56 0.6 0.68 0.77 0.89 RPM 7 753 803 866 99 987 037 7 5 B 0.48 0.50 0.54 0.6 0.69 0.76 0.8 0.93.05 RPM 776 83 857 9 970 07 079 68 49 B 0.6 0.64 0.68 0.74 0.83 0.9 0.99..4 RPM 840 874 93 959 03 068 9 0 B 0.79 0.8 0.85 0.90 0.99.08.7.33 RPM 905 936 97 0 058 09 60 5 B 0.99.0.04.0.7.7.37.56 RPM 969 999 030 066 07 53 0 B..4.7.3.39.48.59 RPM 034 06 09 3 59 00 B.48.50.53.58.64.73 ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

SIS Performance Data /4 /3 / / 00 400 600 800 000 00 400 600 800 3000 300 3400 3600 3800 4000 400 0.00.5.50.375.500.65.750.00.5.50 RPM 407 505 B 0.08 0. RPM 440 533 60 680 B 0. 0.6 0.0 0.4 RPM 478 56 636 70 763 B 0.6 0.0 0.5 0.30 0.35 RPM 438 58 59 665 78 786 84 B 0.7 0. 0.6 0.3 0.37 0.4 0.48 RPM 487 56 65 693 756 8 865 963 B 0.3 0.8 0.3 0.39 0.45 0.5 0.57 0.70 RPM 536 605 663 73 785 840 89 985 B 0.3 0.36 0.4 0.47 0.54 0.6 0.68 0.8 RPM 584 649 703 757 84 869 99 00 094 75 B 0.40 0.46 0.5 0.57 0.64 0.7 0.80 0.94.09.4 RPM 633 693 744 793 845 897 947 037 9 95 B 0.5 0.57 0.63 0.69 0.76 0.84 0.9.09.5.40 RPM 68 738 787 833 879 98 976 065 45 9 B 0.63 0.7 0.77 0.83 0.90 0.98.07.5.4.59 RPM 730 784 830 873 96 960 006 094 7 45 B 0.78 0.86 0.93 0.99.06.4.3.43.6.79 RPM 779 830 874 95 955 995 037 00 7 B 0.95.03..5.4.3.4.6.8.0 RPM 87 876 99 958 995 03 07 5 9 B.3.3.3.38.45.53.6.8.04 RPM 876 9 963 00 037 07 07 8 58 B.35.45.53.6.69.77.85.05.8 RPM 95 968 008 044 079 46 B.59.69.78.86.95.03. RPM 973 05 053 088 B.85.96.06.5.4 RPM 0 06 B.4.6 ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

SIS 5 Performance Data /4 /3 / / 3 800 00 400 700 3000 3300 3600 3900 400 4500 4800 500 5400 5700 6000 6300 6600 0.00.5.50.375.500.65.750.00.5 RPM 75 B 0. RPM 94 366 B 0.5 0. RPM 68 37 38 B 0.6 0.0 0.7 RPM 30 344 397 454 B 0.3 0.7 0.33 0.4 RPM 335 37 47 469 B 0.3 0.36 0.4 0.5 RPM 368 40 44 486 533 B 0.4 0.47 0.53 0.6 0.7 RPM 40 43 466 506 549 59 B 0.54 0.59 0.66 0.74 0.84 0.95 RPM 435 463 493 58 567 607 646 B 0.68 0.74 0.8 0.89 0.99.0. RPM 469 494 5 553 587 64 66 73 B 0.85 0.9 0.99.07.6.8.40.66 RPM 50 56 55 579 609 64 677 746 B.04..9.7.36.47.60.88 RPM 536 558 58 606 634 664 695 76 83 B.7.34.4.50.60.7.83..4 RPM 569 590 6 635 660 687 75 777 837 B.5.60.68.90.87.97.08.38.69 RPM 603 6 64 664 687 7 738 794 85 B.8.89.97.07.6.6.39.67.99 RPM 636 654 684 694 75 737 76 83 B...4.40.50.60.7.99 RPM 670 687 705 74 744 764 787 834 B.48.57.66.76.87.97 3.0 3.36 RPM 703 79 736 754 773 79 B.87.96 3.05 3.6 3.7 3.38 RPM 736 75 B 3.9 3.39 ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 3

SIS 8 Performance Data /3 / / 3 5 800 300 3600 4000 4400 4800 500 5600 6000 6400 6800 700 7600 8000 8400 8800 900 0.00.5.50.375.500.65.750.00.5.50 RPM 33 378 436 485 B 0.3 0.3 0.4 0.53 RPM 34 396 453 50 545 585 B 0.3 0.4 0.5 0.64 0.76 0.88 RPM 304 370 40 470 59 56 60 B 0.3 0.43 0.54 0.65 0.77 0.9.04 RPM 338 400 446 490 536 579 68 687 75 B 0.43 0.57 0.68 0.80 0.93.07..5.8 RPM 37 43 473 53 554 596 635 704 766 83 B 0.58 0.74 0.85 0.97..6.4.73.07.40 RPM 406 46 50 539 576 64 65 7 78 838 B 0.75 0.94.06.8.33.48.64.98.34.70 RPM 439 493 53 566 600 634 670 738 799 854 B 0.94.7.30.43.58.73.90.5.64 3.0 RPM 473 54 56 595 66 657 689 755 86 87 B.8.4.58.7.86.4.9.56.96 3.37 RPM 507 556 59 64 654 683 7 773 833 888 B.45.73.90.05.0.37.54.9 3.3 3.75 RPM 54 587 63 654 68 70 737 79 850 B.77.06.6.43.58.75.93 3.30 3.73 RPM 574 69 654 684 7 737 763 84 868 B..44.66.84 3.00 3.7 3.36 3.75 4.7 RPM 608 65 685 74 740 766 790 839 888 B.5.86 3. 3.3 3.47 3.66 3.84 4.6 4.68 RPM 64 683 76 744 770 795 88 864 B.95 3.3 3.60 3.8 4.00 4.0 4.38 4.79 RPM 676 75 747 775 800 84 847 B 3.45 3.84 4.3 4.38 4.58 4.78 4.98 RPM 70 747 779 806 83 854 876 B 3.99 4.40 4.74 5.00 5.3 5.44 5.64 RPM 743 780 80 837 B 4.58 5.03 5.37 5.67 RPM 777 8 B 5.4 5.70 4 ALL SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

SIS and Roof Curb Dimensions 44 5/8 C B A SQ. INTAKE EXTENSION (OPTIONAL) D SQ. H O.D. 5/8 5/8 J I.D. / THICK INSULATION 8 STD. HEIGHT E SQ. F SQ. G SQ. Unit Ventilator Dim. Roof Curb and Damper Dimensions Filters Size A B C D E F G H J Qty Size 9, 0 30 5 / 3 3/8 36 / 4 / 3 /4 8 / 5 /4 6 X 5 30 5 / 33 36 / 4 / 3 /4 8 / 5 /4 0 X 5 5, 8 4 9 / 4 48 / 36 / 34 35 /4 40 / 37 /4 4 0 X 5 Dimensions in inches 5

Installation Most models are shipped fully assembled and ready for installation. Always inspect equipment for transit damage before accepting delivery to assure valid claim. Special handling and storing procedures are required if unit is to remain idle for an extended period of time before installation. Placement: All units must be accessibly installed for maintenance and servicing of belts and bearings, and for routine cleaning. Mounting: Satisfactory operation of ventilators requires mounting on adequately designed and constructed roof curbs. Pre-fabricated curbs for convenience in installation are available from ILG. Install with base of unit horizontal. Provide adequate caulking, flashing or other weatherproofing means. Duct connections are made below unit. Inspection: Check centrifugal wheel for free rotation. Check belt for proper tension. Check motor and fan sheave faces for proper alignment. Check circuit phase, voltage and wiring connection against that shown on motor nameplate. Check direction of fan rotation for proper air flow. After one week of operation, check belt for proper tension. Maintenance Units should be checked and cleaned monthly for the first two or three months, and periodically thereafter. Regular Inspection: Units should be cleaned of material build-up every three months or when necessary, depending on condition of air and frequency of use. Any eroded parts should be replaced to avoid structural damage and possible failure. Belt Adjustment: Belt alignment and tension should be adjusted if necessary. Inspection every 6 to months is recommended. WARNING CAUTION DO NOT INSTALL FAN WITH MOVING PARTS WITHIN 8 FEET OF FLOOR OR GRADE LEVEL WITHOUT A GUARD THAT COMPLIES WITH OSHA REGULATIONS. DO NOT USE UNLESS ELECTRICAL WIRING COMPLIES WITH ALL APPLICABLE CODES. DO NOT WIRE WITHOUT PROVIDING FOR A POWER SOURCE DISCONNECT AT THE FAN ITSELF. DO NOT SERVICE EXCEPT BY A QUALIFIED MAINTENANCE TECHNICIAN AND ONLY AFTER DISCONNECTING THE POWER SOURCE. FAILURE TO OBSERVE THESE PRECAUTIONS CAN RESULT IN SERIOUS INJURY OR DEATH. Options and Accessories Pre-fabricated Roof Curbs Insulated roof curbs with weather-proof continuous welded construction are available for both insulated and non-insulated roof decks. Special Motors Two-speed, totally enclosed, energy efficient and explosion-proof motors for hazardous locations may be available for many models. Motor requirements may affect UL Listing. Backdraft Dampers Gravity or motor operated backdraft dampers are available. They are aluminum construction and designed for installation in prefabricated roof curbs. Safety Disconnects Safety disconnects cut power to motor for servicing of unit. A disconnect switch is an option for CFS and SIS units and may be shipped loose for field installation or factory mounted and wired. Protective Coatings Fan units are not recommended for ventilating air of a corrosive nature. However, special protective coatings are available where units may be exposed to corrosive exterior conditions. Parts requiring painting are processed through the American Coolair fivestage pretreatment system prior to the application of any coatings to insure maximum finish adhesion. These parts use a thermosetting epoxy powder paint with an average thickness of 3 mils and baked at 400 F to a smooth, hard continuous finish. Consult your ILG Industries representative for available coatings. Limited Warranty In the sale of its products, American Coolair Corporation agrees to correct, by repairs or replacement, any defects in workmanship or material that may develop under proper and normal use during the period of one year from the date of shipment from the factory. Any product or part proving, upon American Coolair's examination, to be defective during limited warranty period will be repaired or replaced, at American Coolair's option, f.o.b. factory, without charge. Deterioration or wear caused by chemicals, abrasive action or excessive heat shall not constitute defects. Motors are guaranteed only to the extent of the manufacturer s warranty. American Coolair's limited warranty does not apply to any of its products or parts that have been subject to accidental damage, misuse by the user, unauthorized alterations, improper installation or electrical wiring, or lack of proper lubrication or other service requirements as established by American Coolair. Repairs or replacements provided under the above terms shall constitute fulfillment of all American Coolair's obligations with respect to limited warranty. THE LIMITED WARRANTY STATED HEREIN IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS, STATUTORY OR IMPLIED, INCLUDING WITHOUT LIMITATION THAT OF MERCHANTABILITY AND FITNESS. NO LIABILITY FOR REINSTALLATION COST OR FOR ANY SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY NATURE IS ASSUMED OR SHALL BE IMPOSED UPON AMERICAN COOLAIR. REPRESENTED BY: GENERAL OFFICES, JACKSONVILLE, FLORIDA 303-300 ~ P.O. BOX 300 ~ (904) 389 3646 ~ FAX (904) 387 3449 ~ E-MAIL fans@coolair.com VANE AXIAL FANS ~ TUBE AXIAL FANS ~ PROPELLER FANS ~ POWER ROOF VENTILATORS ~ CENTRIFUGAL VENTILATORS MEMBER OF AMCA Form No. 77-5-4 (August, 008)