9505AER MODEL FEATURES MOBILITY / LUBRICITY TESTER FOR CANS AND FLAT SAMPLES DESCRIPTION OPERATION SAFETY COEFFICIENT OF FRICTION READOUT

Similar documents
Rack Mount Power Supplies

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

The FMM force tester can be controlled using L1 software for limit, cycling, hold and coefficient of friction testing.

ADVANCED. Cement Compression & Flexural Testing Machines.

EL Beam Sensors Standard & SC Versions

BTB TYPE AUTOMATIC TRANSFER SWITCH (ATS)

MPT-200A SPECIFICATIONS AND OPERATING INSTRUCTIONS

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Power Switching Devices

SWII Users Manual. Intercomp Co County Road 116 Minneapolis, MN (763) Fax

OnCommand Troubleshooting Guide Hayward Industries

Cleveland-Kidder. Design Features

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

Cement Compression & Flexural Testing Machines

Cleveland-Kidder Ultra

MPT-250B SPECIFICATIONS AND OPERATING INSTRUCTIONS

SmartPak Welding Controller WK-MPS-16 Constant Current

Data Sheet Type FF420. Series 420 Specification Flange / Flange. Series 420 Non-Contact Rotary Torque Transducer

SP5 INSTALLATION AND SETUP MANUAL

Compression/Tension Testing Machines

MODEL MSD MOTION CONTROL INSTALLATION AND OPERATION

Installation & Calibration

SSP-7080 USER MANUAL. 80W Constant Power Switching Mode Power Supply with Master & Slave Remote Sensing. Rev /

PowerView PV380-R2 Mechanical Configuration

CIRCUIT-TEST OPERATION MANUAL. Switching Mode Power Supply with Remote Sensing PSC V 5A / 0-27V 3A / 0-36V 2.2A (80W)

THERMOCOUPLE CALIBRATOR Mode KM-CAL-710

Instruction Manual. Digital Panel Meter Model 3126 CAUTION. Code Type of T/C Measuring Range Display Range Accuracy

USERS MANUAL MCD REMOTE OPERATOR

Flight Systems. Replacement for KASSEC DESCRIPTION

EZ-TRAC Digital Tension Readout and Control

HYGROMETERS HUMIDITY MEASUREMENT YOU CAN COUNT ON.

- 4 amp (100VA). - 4 amp (100VA). - Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.

AUTOMATIC 12 WAY HEAT TREATMENT CONSOLE

POWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc.

CCTV Rack Mount Power Supplies

Intelligent torque meter tester

RVS-DX Digital Reduced Voltage Motor Starter

Installation & Calibration Manual

USER MANUAL LOAD CELL (Expansion)

Installation Instructions & Users Manual

SOFT TOUCH FOR PNEUMATIC RIVETERS

11280A HercuLine Series Actuator. Specification. Non-Contact Position Sensing and Variable Speed Motor Control. Overview. Features. Actuator Operation

Digital Scale. Revision 1.0 August 17, Contents subject to change without notice.

Harris IRT Enterprises Digital Resistance Tester Model XP

GTFM IV. Operation / Installation Manual. Gas Turbine Flow Monitor. Computer Weld Technology, Inc. Manual Part Number: A8M5010 Revised: June 26, 2008

SSP-Series Portable Balances Operation Manual

PRO AC/DC CHARGER #611

HANATEK FRICTION TESTER. MODEL 6010 (Obsolete) INSTRUCTION MANUAL. Replaced by:

URM-00 TRAINING MODULE FOR INDUSTRIAL ELECTRIC MOTORS FOR MAIN DRIVE AND CONTROL CIRCUITS EDUCATIONAL KIT TO STUDY MOTORS CONTROL AND PROTECTION

- 4 amp. - 4 amp. - Sixteen (16) Fuse Protected - Sixteen (16) PTC Protected

Q Range Watertight Single-Phase Electric Quarter-turn Actuators for part-turn valves and dampers

TABLE OF CONTENTS 1. FEATURES SPECIFICATIONS... 1

ORPscan20 Pocket ORP Tester Instruction Manual

SAMTEC POWER CHARACTERIZATION

DIGITAL MULTIMETER INSTRUCTION MANUAL

Electric Vehicle Supply Equipment EVSE Vehicle Simulator

Model HRDT High Resolution Digital Telemetry Rotary Torque Transducer

SED2. Variable Frequency Drives. with Conventional Bypass Options. Variable Frequency Drives. Description. Features F-9.

ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance

TDSscan10M Pocket TDS Tester Instruction Manual

OPERATION AND MAINTENANCE

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

ASYN205B Central Synchronizing Controller

UL Listed CCTV Power Supplies. - 4 amp. - 4 amp. - Eight (8) Fuse Protected - Eight (8) PTC Protected

J1000. Compact Inverter Series.

RVS-DN Digital Reduced Voltage Motor Starter

ReadStar & CapStar Range Torque Readouts & Torque Testers. Crane Electronics Inc The force in torque management

SOFT TOUCH for PNEUMATIC RIVETERS

DIGITAL MICROHMMETER TYPE DO7

TTT802 Gearshift Controller, Part # R1N-S (Standard), -P (Paddleshift)

Dynasafe HF 32 Universal Load Cell

INSTRUCTION MANUAL Hobbico, Inc. HMXR4854

Helios. 24 Light 240 Volt Controller. PRODUCT # Instruction Manual.

AQUASTAR C6. (Comfort 6000) Next Generation Auto Backwash Valve System. (selectable time-pressure or remote cycle start)

Application Guide Paragon TM Control Module (PCM) Slide Valve and Protection Control 10/25/2016 Rev 1. Carlyle Controller Part No.

SPC Series. Digital Scale. Operation Manual

4 amp (100VA). - 4 amp (100VA). - Four (4) Fuse Protected - Four (4) PTC Protected

Application Engineering

A flexible, reliable and affordable drive for 1/4 through 2 HP DC applications

PORTABLE POWER SUPPLY MODEL NUMBER VMS-1 VERSION 1.0

User s Manual. For DM860T. Fully Digital Stepper Drive. Version 1.0 Designed by StepperOnline All Rights Reserved

Table of Contents General Specifications, Available Mountings... 1 Introduction... 2 Application Examples... 3 Features... 4 Theory of Operation... 5

DETAIL SPECIFICATION SHEET

1291BL Series Technical Specification Single Axis Position and Rate Table System

MAGTROL. TF Series Torque Flange Sensor. TF data sheet FEATURES. DESCRIpTION. AppLICATIONS

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

Application Engineering

! Warning, refer to accompanying documents.

SPECIFICATIONS SRM10 24V 0.5A MEDICAL CHARGER

CCTV Rack Mount Power Supplies

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Section 03: Installation Procedures

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

TORQUE MEASUREMENT EQUIPMENT

Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A

DRILL PRESSES. Mechanical Variable Speeds rpm Electronic Variable Speeds rpm CNC Power Feed EVS Speeds rpm

MaxPak Plus Analog DC V S Drive

Transcription:

CDLM2002 MODEL 9505AER MOBILITY / LUBRICITY TESTER FOR CANS AND FLAT SAMPLES FEATURES COEFFICIENT OF FRICTION READOUT VARIABLE OR PEAK READINGS OBTAINED VIA ANALOG ELECTRONIC METER MEASUREMENT VIA ELECTRONIC LOAD CELL RECORDER FOR PLOTTING RESULTS QUICK MOUNT - CHANGE PARTS TESTS CAN BODIES AND BOTTOMS TESTS FLAT SAMPLES RELIABLE MOTOR DRIVEN DESIGN SPEED ELECTRONICALLY CONTROLLED LEVELING ADJUSTMENT LATEST MODEL MAY VARY SLIGHTLY FROM PHOTO DESCRIPTION The MODEL 9505AER Mobility/Lubricity Tester is used to determine the coefficient of friction of decorated or coated body blanks or cans. The 9505AER tests can bottoms and many other flat materials as well. OPERATION An appropriate set of Change Parts, determined by the type and size of can or sample being tested, are installed on the tester. The sample is mounted on the Change Part and a test sequence is initiated. By traversing a weight across a sample, a can body diameter or a can bottom across a set of polished rods, the coefficient of friction is determined and indicated directly on the electronic analog meter and plotted on the chart recorder. SAFETY The 9505AER safety features include built-in travel stops and overload protection. See us on the Web @ http://www.altekcompany.com or email to tech@altekcompany.com

PRODUCT OVERVIEW The MODEL 9505AER Mobility/Lubricity Tester is used to determine the coefficient of friction of a sample. The 9505AER can test flat samples, formed can bodies, and can bottoms. The 9505AER is capable of testing the lubricity of a decorated or coated can body or body blank. It can also test the mobility of the bottom of a can body which has not yet had it s end seamed on. In addition, the 9505AER can be used to test the lubricity of a flat sample of almost any type of material. The design of the 9505AER incorporates a reliable electric motor drive for clean, quiet, trouble-free operation. The speed of the drive is electronically controlled, and is selectable via a front panel switch providing a constant speed throughout the test cycle. The 9505AER test results are indicated directly in coefficient of friction units on the electronic analog meter. The meter incorporates two reading modes. The Test mode displays only the maximum or peak result. The Cal mode, displays the range of results while the weight is being traversed across the sample. The unit also utilizes a chart recorder which provides a permanent hardcopy record of test results. The 9505AER must be fitted with an appropriate set of Change Parts in order to test each specific size and type of sample. These Change Parts are manufactured by the Altek company and are required for operation of the unit. Built-in leveling feet allow proper leveling (using the bubble level incorporated into the Change Parts) which helps to ensure accurate, reliable test results. The 9505AER should provide years of trouble-free service. APPLICATION NOTES The 9505AER is used when the reliability of an electronics package is preferred over a mechanical gauge for the indication of test results. The 9505AER also provides the user with a hardcopy pen plot of coefficient of friction vs. time of the sample under test. SPECIFICATIONS The following documents describe the specifications for this unit: CDXH0501 - Specifications for the 9505A3 Test Head CDXS0401 - Specifications for the 9531A2 Analog Meter CDXS0201 - Specifications for the 9825-2 Recorder CHANGE PARTS This unit requires the use of Change Parts. Please refer to the following documents for details regarding the Change Parts available for this unit: CDLC12## - Advertising Flier CDXC12## - Change Parts Specifications OPTIONS Options specified when ordering the 9505AER include: Input Line Voltage TECHNICAL SUPPORT Altek provides comprehensive technical support to its customers worldwide. For assistance, contact Altek and ask for the Engineering department. REPAIR Altek customers can obtain a return authorization from Altek and ship a faulty unit in for repair if necessary. In addition, replacement parts for all models are available from Altek. WARRANTY All Altek products are built to the highest standards of quality and reliability. This Altek product is backed by a full 90-day warranty. FURTHER INFORMATION See the accompanying fliers and specifications for additional information concerning this product. If these documents were not included with this flier, please call Altek; they will be mailed or faxed as quickly as possible. CUSTOM DESIGN Altek can custom design inspection and test equipment to meet specific customer requirements. Custom Change Parts can also be designed and manufactured for most Altek products; contact Altek for further information. For more information, contact Altek between 8:00 am and 5:00 pm ET, Monday thru Friday. The Altek company address and phone numbers can be found on the front of this flier. ORDERING INFORMATION To purchase this product: This flier is supplemented by additional literature, including specification sheets and Change Parts fliers and specifications. The 9505AER Mobility/Lubricity Tester requires the use of Change Parts, which must be ordered separately; see the accompanying literature. The 9505AER is ordered by requesting the 9505AER Customer Order Guide from the Altek Sales Department. The Order Guide, which is filled out by the customer and returned to Altek, provides Altek with the information necessary to process an order for this unit. Thank you for your interest in TECH products from Altek!

CDXH0501.004 \y9505a3 SPECIFICATIONS MODEL:... 9505A3 TEST HEAD CHANGE PARTS SPECIFICATIONS:.. C12 (CDXC1201) EFFECTIVE DATE:... MARCH 1, 2001 & DENOTES OPTIONS SPECIFIED BY CUSTOMER WEIGHT/DIMENSIONS:... 18# / 20"l x 10"w x 12"h ENVIRONMENT: Temperature... 50-105 degrees F Humidity... 80% max ELECTRICAL: Supply Connection... standard 3-prong grounded & Supply Voltage... 115, 230 vac (Model 9823 Transformer required for 230 vac operation) Supply Frequency... 50/60 hz, single phase Supply Protection... 15 amp max Operating Current... 1 amp max Overload Protection... 0.5 amp circuit breaker Test Speed... dual: 5"/min and 20"/min Test Travel... 3 1/2" (Consult ALTEK for longer travel lengths) Sample Capacity... 307 dia, 710 hgt (open can), (3 7/16" dia, 7 10/16" hgt), 6" wide, 8" long (flat sample) See Analog Monitor Specifications CDXS04xx.xxx or Digital Monitor Specifications CDXS08xx.xxx

28 CDXS1001.001 9531DA2F SPECIFICATIONS COMPONENT:... 9531DA2F DIGITAL MONITOR EFFECTIVE DATE:... MARCH 1, 2000 WEIGHT/DIMENSIONS: (approx)... 15# / 12"l x 14"w x 7"h ENVIRONMENT: Temperature... 50-105 degrees F Humidity... 80% max ELECTRICAL: Supply Connection... standard 3-prong grounded Supply Voltage... 115, 230 VAC Supply Frequency... 50/60 hz, single phase Supply Protection... 15 amp max Operating Current... 1 amp max Overload Protection... 1 amp circuit breaker Mode Switch (set-up).. Test or Calibration Mode Switch (test)... Peak Coefficient of Friction Zero Adjust... inside panel control Calibration Adjust... inside panel control Sampling Rate... 4 Sample Points / Sec. INPUT: Transducer... 6 pin quick connect Readout... 4 digit, 0.560" high red LED Capacity....250 µ (500 grams full scale) Resolution... ± 1.0 count Recorder Output... 0-1 VDC analog ±50 mv Auxiliary Output... 25 pin RS-232 serial Communication... 9600, 8 bit, 1 stop, no parity (default settings; field alterable by customer)

CDXS0601.001 \y9531a2 SPECIFICATIONS COMPONENT:... 9531A2 ANALOG MONITOR EFFECTIVE DATE:... MARCH 1, 2000 WEIGHT/DIMENSIONS: (approx)... 15# / 12"l x 14"w x 7"h ENVIRONMENT: Temperature... 50-105 degrees F Humidity... 80% max ELECTRICAL: Supply Connection... standard 3-prong grounded Supply Voltage... 230 VAC Supply Frequency... 50/60 hz, single phase Supply Protection... 15 amp max Operating Current... 1 amp max Overload Protection... 1 amp circuit breaker Mode... Peak Hold or Calibration Zero Reset... front panel button Zero Adjust... inside panel control Calibration Adjust... inside panel control INPUT: Transducer... 6 pin quick connect Readout... 4 1/2" wide analog meter Capacity... 0.0-0.25 æ direct reading of coefficient of friction; 0-500 grams full scale (for calibration use only) Resolution....01 æ Auxiliary... 0-1 VDC analog ñ50 mv