POWER kva

Similar documents
POWER kva

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

TECHNICAL DATA SHEET KVA UPS Systemss

EFFEKTA Power Supplies

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Technical Data Sheets

Technical Data Sheets

Technical Data Sheets

Technical Data Sheets

POWERTRONIX QUASAR 5-40 KVA

Technical Data Sheets

Technical Data Sheets

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical data sheets

Technical Data Sheets

PowerValue 11/31 T kva

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

D Series: UPS UPTO - 300KVA - Three / Three Phase

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

MKN-DSP SERIES - THREE PHASE

Three Phase UPS Systems Range: 10 to 500kVA

Industrial PFC UPS System

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

PowerWave 33 Efficient power protection for today s IT and process-related work environments

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

1.1 GENERAL CHARACTERISTICS

TLE Series UPS 400/500 kw With eboost Technology

Marketing Management Team of Europe

ConceptpowerTM Modular kVA

Master DIALOG INDUSTRY RANGE

TLE Series UPS 160/200/225/250 kw with eboost Technology

Liebert. FP 50Z kva

PowerScale kva Technical Specifications

TECHNICAL SPECIFICATIONS

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

PowerScale TECHNICAL SPECIFICATIONS

PowerWAVE EL. Technical Specification. (Single phase 500 VA 30 kva. Three phase kva)

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

TLE Series UPS 750/1000 kw With eboost Technology

EATON 9315 UPS 200 TO 300 KVA Specifications

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

MASTERYS IP+ 10 to 80 kva

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

Power+ CLASSIC. 20/30 kva, 3x208 Vac

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Technical data sheets

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

GUIDE SPECIFICATION THREE PHASE UNINTERRUPTIBLE POWER SUPPLY

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

TOSHIBA /20/25/30/50kVA Internal Battery GUIDE SPECIFICATION THREE PHASE UNINTERRUPTIBLE POWER SUPPLY

Illuminator Series CR NEMA 3R

Liebert GXT & 6000VA RT230 Rack-Tower models GUIDE SPECIFICATIONS 1.0 GENERAL

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Liebert Hipluse U UPS;80-400kVA; 380/400/415V Detailed Specification

Liebert Hipulse E The High-ECO-Availability UPS. AC Power Systems

AME. Rectifier - Battery charger. Industrial applications: Key features:

60 to 160 kva.

Industrial Chargers and

magellan commercial UPS solutions Magellan Power Modular - Flexible UPS

Liebert APM UPS. For a 30 to 150 kva / kw (50 or 60Hz) Modular Digital Uninterruptible Power Supply (UPS) System. V nd February 2010

G V Series UNINTERRUPTIBLE POWER SYSTEMS. Phone: Fax: Web:

Three Phase UPS Systems

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

Technical Specification SENTINEL PRO

MEGALINE UPS MODULAR SINGLE-PHASE from 1250 to VA

Green Power 2.0 MASTERYS GP

SitePro UPS 400Vac / CE. GE Consumer & Industrial August 2004

tel: Enhanced Power Services Limited Industrial PLCs Electro Medical Devices

UPS Multi Sentry 10-20kVA

DPP/3DPP. Digital ProcessPower UPS INDUSTRIAL PWM UNINTERRUPTIBLE POWER SUPPLY SYSTEM SINGLE PHASE THREE PHASE

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

UPSaver 20012,800KW. Efficiency. Scalability. Product Highlights

Product Specifications

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

Liebert GXT & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL

Master Plus kva

Master Plus kva

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase

Transcription:

+44 (0)20 8868 3732 TECHNICAL DATA SHEET B9600 400-800kVA GENERAL INFORMATION UPS Type ON LINE - Doppia Conversione Nominal output power (Cos φ0,8) kva 400 500 600 800 Nominal output power (Cos φ1,0) kw 320 400 480 640 @25 load >88 Efficiency (AC AC) @50 load >90 (ON LINE - Double Conversion) @75 load >92 @100 load >93 Efficiency (AC AC) (Eco Mode) > 98 Heat dissipation at nominal load and voltage kw 22,4 28 33,6 44 kcal/h 19,2 24 28,8 38 UPS ambient temperature C 0 40 BATTERY ambient temperature C 0 +25 UPS storage temperature C -10 +70 BATTERY storage temperature C -10 +60 Relative humidity (non condensing) < 95 Altitude m < 1000 (above sea level) Power derating for altitude > 1000 m According to IEC62040-3, 1 power derating every 100m above 1000m, up to max 2000m Ventilation Forced Requested cooling air volume m 3 /h 3500 4000 4500 7000 Audible noise level (according to IEC EN 62040-3) db < 60 Standard battery type lead acid n cells 300 312 adjustable Protection degree IP 20 Electromagnetic compatibility EMI According to IEC EN 62040-2 (CE marking) Safety IEC EN 62040-1 Test and performance IEC EN 62040-3 Paint RAL 9005 Accessibility Front and top access for service Installation Also against wall Dimensions mm W = 1990 D = 990 H = 1920 and/or side-by-side W = 2440 W = 2440 D = 990 D = 990 H = 2020 H = 2020 W = 3640 D = 990 H = 1920 Weight (without battery) kg 1820 2220 2400 3600 Static load (without battery) kg/m 2 924 917 992 992

Input/Output cable connection Bottom Side (Top Side on Request) Transport Base provided for forklift handling Transport mechanical stress According to IEC EN 62040-3 Design Standards IEC EN 62040 ISO 9001:2008 Free contact interface Standard per remotizzare i seguenti contatti: EPO MBCB BCB DIESEL MODE Serial communication interface Standard: RS232 - USB Optional: RS485 (Mod-Bus protocol) Parallel configuration (optional) Up to 5+1 (redundant parallel) Up to 6 (power parallel) BLOCK DIAGRAM 1. Input mains (separate for by-pass and rectifier) 2. Rectifier and battery charger 3. External battery 4. Inverter 5. Emergency line (by-pass) with optional backfeed contactor 6. Inverter (SSI) and by-pass (SSB) static switch It is possible to install an external Manual Bypass, either in matching cubicle or in wall mounted box (bypass switch auxiliary contact must be connected to UPS related input port for status monitoring).

UPS INPUT: RECTIFIER AND BATTERY CHARGER Input Triphase Nominal input voltage Vac 400 VAC -20/+15 Input frequency 50 60 ±5 Input power factor > 0.99 @25 load <10 Input current THD at nominal voltage @50 load <7 and THDV <0,5 @75 load <5 @100 load <3 DC output voltage accuracy ±1 DC output voltage ripple rms 1 Battery recharging characteristic IU (DIN 41773) Maximum recharging current - at nominal load A 60 80 80 120 - with DCM function (max current) 100 100 100 100 AC-DC converter type PFC IGBT Input protection Fuses Nominal current absorbed from mains (at nominal load and battery charged) A 500 620 750 1000 Maximum current absorbed from mains (at nom. load and max. recharging current) A 560 700 820 1120 Sectable walk-in sec Sectable from 5 to 30 Sectable hold-off sec Sectable from 1 to 300 BATTERY Type (standard) other on request Lead Sealed maintenance free Number of Cells 300 312 adjustable Floating voltage at 25 C Vdc 680 for 300 cells, 707 for 312 cells (adjustable) Minimum discharge voltage Vdc 496 for 300 cells, 516 for 312 cells (adjustable) Inverter input power (at nominal Load) kw 336 420 500 672 Inverter input current ( at nominal load-minimum Vdc) A 680 850 1020 1360 Battery Protection (external to the UPS) Wall mounted fuse box on request Battery Test Included as standard

UPS OUTPUT: INVERTER Inverter Bridge IGBT (High Frequency PWM.) Nominal output power (Cosφ 0,8) kva 400 500 600 800 Nominal output power (Cosφ 1,0) kw 320 400 480 640 Efficiency (DC AC) @25 load @50 load @75 load @100 load Output Three-phase + Neutral Nominal Output Voltage (selectable) Vac 380-400-415 Output Voltage Stability - Static (Balanced Load) ±1 - Static (Unbalanced Load) ±2 - Dynamic (Step Load 20 100 20) ±5 - Output Volt. Recovery Time(after step load) <20 ms - IEC EN 62040-3 Class 1 Phase Angle Accuracy - Balanced Load - 100 Unbalanced Load ± 1 ±1 Output Frequency (selectable) 50-60 Output Frequency Stability - Free Running Quartz Oscillator - Inverter Sync. with Mains - Slew rate /s 90 92 94 95 ± 0,001 ± 2 (other on request) 1 Nominal Output Current (@ 400 Vac output) - Cosφ 0,8 A 590 720 860 1180 - Cosφ 1 460 580 720 920 10 min >100 125 Overload Capability 1 min >125 150 10 s >150 199 Short Circuit Current A 690 870 1080 1380 Short Circuit Characteristic Elect. short circuit protection, current limited at 1.5 times nominal current. Automatic stop after 5 seconds Selectivity Within ½ cycle (Fuse gl 20 In) Output Waveform Sinusoidal Output Harmonic Distortion - Linear Load <1 - Non Linear Load <5 - IEC EN 62040-3 Fully compliant Max Crest Factor without derating 3 : 1

UPS OUTPUT: BY PASS Automatic static by-pass Electronic Thyristor Switch Protection Fuses Bypass Vac Triphase + Neutral Nominal Voltage (selectable) Vac 380-400-415 ±10 Nominal Frequency (selectable) 50-60 ± (1 5) adjustable Transfer mode Without break Transfer inverter automatic bypass In case of : - Static Switch test - Inverter test - Inverter not operating - Battery end of discharge Retransfer automatic bypass inverter - Automatic - Block on bypass after 6 transfers within 2 minutes, reset by front panel Overload Capability 150 Continuously 1000 For 1 Cycle Manual By-Pass Option (external): - Electronically controlled - No break

OPTIONS 1. BATTERY TEMPERATURE VOLTAGE COMPENSATION 2. INSULATION TRANSFORMER ON BY-PASS 3. VOLTAGE ADAPTATION AUTO-TRANSFORMERS 4. RELAY CARD (Eight signals Alarms/Statuses), Free relay contact 5. SERIAL INTERFACE RS-485 (MOD-BUS protocol) 6. SNMP ADAPTER 7. REMOTE MONITORING PANEL 8. PARALLEL CARD INTERFACE KIT 9. EXTERNAL BATTERY CABINET 10. WALL MOUNTED FUSED SWITCH BOX 11. IN/OUT TOP CABLE ENTRY 12. SPECIAL PAINT 13. LOAD-SYNC BUS CARD INTERFACE KIT 14. BACK FEED PROTECTION 15. MANUAL BYPASS SWITCH IN MATCHING CUBICLE OR WALL MOUNTED BOX OTHER SOFTWARE SELECTABLE FEATURES 1. DIESEL-MODE 2. ECO-MODE 3. BOOST-CHARGE 4. RECTIFIER WALK-IN TIME 5. RECTIFIER DELAY ON STARTUP (HOLD-OFF TIME) 6. FREQUENCY CONVERTER MODE 7. DCM FUNCTION