Local Control Network - building controls in perfection

Similar documents
ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S

Emergency lighting units EM powerled

Emergency lighting units EM powerled

Emergency lighting units EM series

DEVICE STATE/BYPASSED FAILURE OVERLOAD

Emergency lighting units EM powerled

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

UNIVERSAL PUSHBUTTON DIMMER ETD 2 (Rail mount version)

Electronic Ballast EVG 2000-T

System 2000 DRA automatic stairway lighting, Impulse insert. 1 Safety instructions. 2 Device components

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series

1 Safety instructions

Electronic Circuit Breaker ESS20-0..

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Process controller. for pneumatic and electric actuators. Process controller V. Process controller

Electronic Circuit Breaker ESS20

Emergency lighting units EM powerled

SINAMICS GM150 IGCT version

Emergency lighting units EM series. EM PRO EZ-3, V PRO version

Technical Information

SWITCHGEAR. 4G cam switches

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W

Parker AC10 Frequency Inverter (to 22kW) Easy Start Guide

User Manual Rittal PMC UPS 6kVA

This Datasheet for the IC670MDL930. Relay 2A 8 Pt. 6 form A/2 form C Isolated.

Power Electronics. MINISTOP Motor Brake Relay BA 9034N

RT2DB Excitation and voltage regulation system for synchronous generators

IB IL 24 PWR IN/F-D IB IL 24 PWR IN/F-D-PAC

1 Safety instructions. 2 Device components. Light Management Rotary dimmer. Operating instructions

Heat Meter Integrator

Uninterruptible Power System

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

EM DC Multi-Function DC Energy Meter

Induction Power Supplies

General_technical_data Series

1 Safety instructions. 2 Device components. Dimmer push-button/2-way low voltage. Order No. : Operating instructions

GE FANUC Parts. VersaPoint Power Terminal. Segment Terminal Fused, with Diagnostics 24VDC IC220PWR013. Features. Ordering Information

Ultra Sine Inverter (US) Generation 4 (G4) User Guide

Micro Contactor MA Series

Example of Combining Different Types of Heater Control. Heater control. Temperature Controller

Power Switching Principles

Uninterruptible Power System

Emergency lighting units EM INVERTER

ADDITIONAL EMERGENCY POWER SUPPLY DEVICES

High Reliable Components for Power Factor Correction and Power Quality

CI-TI Contactors and motor starters Types CI 61 - CI 98

Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis

Uninterruptible Power System

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

Electrical data Nominal voltage AC 24 V Nominal voltage frequency

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. System Universal LED dimming insert Standard

Table of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION...

LIFT INVERTER SERIES L1000V DE ES FR IT 1000V L1000V L1000V L1000V L1000V

ECONOMISER SERIES E2T USER MANUAL

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

DKG-215 MANUAL AND REMOTE START UNIT

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal touch dimmer insert LED

KD LV Motor Protection Relay

Total solder points: 126 Difficulty level: beginner advanced POWER DIMMER 230V) K8038 ILLUSTRATED ASSEMBLY MANUAL

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

GRIDCON ACF ESS GREAT COMBINATION ACTIVE FILTER AND ENERGY STORAGE.

CENTROIDTM. AC Brushless Drive. Product Spec Sheet

Emergency lighting units EM powerled

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical)

SMD10 SMD11 SMD15 SMD30

1.0 Features and Description

JUMO safetym TB/TW Temperature limiter, temperature monitor according DIN EN

Emergency lighting units EM powerled

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Safety Sensor CSS 180 Product Information

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

CI-TI Contactors and Motor Starters Type CI 6-50

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Onboard power supply management

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

PCT-3000 plus DIGITAL PRESSURE CONTROLLER FOR COOLING PLANTS

PO Box 2484 Rowville Vic 3178

COUNTIS E22 Three-phase energy meter Direct - 80 A

Operating Instructions 2-channel pushbutton interface 4-channel pushbutton interface

NOT RECOMMENDED FOR NEW DESIGNS. Wind display type WSDI-2 DATA SHEET. Watertight. Displays

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Contactor Types CI 61-98

Operation Instructions

Loadcell Tension Control

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Emergency lighting units EM Inverter. EM SELFTEST G2, V SELFTEST version

Issue 2.0 December EPAS Midi User Manual EPAS35

ABB i-bus KNX DG/S x DALI-Gateway Basic

Electrical operating instructions

AF series contactors (9 2650)

Power Electronics. Motor brake relay GA 9031 ministop

Transcription:

2 1 F3,15A250V 2 1 1 2 F3,15A250V Installation guide Local Control Network - building controls in perfection Sensor/actuator module for DIN-rail mounting The is a sensor/actuator module for building installation in Bus technology. (The s from 2002 or after have a further functionality and are named SH+ in the LCN-PRO /-P.) switch for A1 ON 1 2 FUSE for A2 enlargement (see text p.4) status LEDs: output 1 output 2 fine wire fuse ON FUSE A1 A2 push-buttonconnection actuator side Local Control Network ISSENDORFF L L N N sensor side N D D LCN Sensor-/Aktor Modul Intelligent Controller U N=230VAC 15%, P V=0,8W phase N data impulse sensorconnection peripheryconnection Application The 4HP sized module is for installing in dry rooms in main and normal distribution boxes. It has 3 electronic outputs, which are seperately controlled. 2 of the outputs are on terminals and can be be operated as switch or as leading edge dimmer. They each provide dimming ramps, timers and scene memories. Additionally there are three sensor connections available (see illustration), which can be used independently from one another and from the outputs. The operating programme of the includes further functions like 2 proportional regulators, 5 thresholds, the LCN panel system etc.. 1

Local Control Network - building controls in perfection Installation guide The connection The module has two terminal blocks: the power supply side with screwless terminals and the sensor side with plug connections. The terminals are colourfully marked as follows: Description: Colour: Function: D,D orange data wire N,N,N blue neutral wire L,L black phase (live) 2 grey output 2 (intern. supplied with fuse for phase/live) white output 1 (intern. supplied with fuse for phase/live) Note: The modules are wired internally to switch/dim from the phase. The power connections are voltage fixed up to max. 4kV(L+N) according to VDE, additional measures against overvoltage in operational conditions are not necessary. Measures for lightning protection in the building should be applied as usual (coarse protection). The power outputs votage fixed up to 500V~ (max. pulse voltage according to IEC801-4: 1kV). Because the electronic switches in the LCN modules switch off on the current zero crossing, no noise levels, even when using inductive loads, are to be expected. 2

Installation guide Local Control Network - building controls in perfection Outputs: The outputs are protected against short circuits on the output side through a 3,15A F backup fuse. The fuse is not suitable, with loads on just one output to avoid an overheating on the built-in interference suppression. That s why you must ensure when connecting the load, that a higher load than 2A cannot occur on each output. The processor in the module is supplied seperately and works even then, when the fuse is removed. The modules recognize a defect fuse and show this locally through flashing on both the LED s from the outputs. Both outputs switch off and sends a status message. The switching on will be rejected with the function message fuse defect in the hand operation on the LCN-P or LCN-PRO. The LCN- SH with ser.nr. 0E... or later monitors its operating temperature. if this gets too high due to an overload, both outputs will be switched off and a status message sent to the Bus: module reports overload/short circuit periphery., After cooling down, the outputs can be switched back on. Basically, the loads should always be checked beforehand. 3

Local Control Network - building controls in perfection Installation guide Notes about the outputs: The electronic outputs do not need a minimum load. This makes it possible to connect small and even inductive loads directly. Due to the required measures for interference suppression according to CE, a small standby current of 4mA (capacitive) flows in every power output. This can cause relays to stick when connected to 230V. Solution: You can deactivate the dim interference filter. According to CE you must then only use the output in the switching mode. Take a look at the circuit board: on the left next to the fuse holder, you will find a two way mini sliding switch, which is marked with 1 and 2 (see illustr. on page 1). When you slide the switch 1 downwards (away from the ON marking), the interference condenser from output 1 is deactivated. the same with switch 2 for output 2. When connecting gas discharge lamps with control gear, the reactive current should be considered, the connectable load is reduced to half. Solution: Compensate the lights by simply connecting a condenser parallel or in series. with electronic zero-voltage switches, the problem with contact burn-up when using capacitive loads, will not occur. That s why you can connect large condensers to the outputs in switching mode (not in dimming mode!) For this reason a parallel compensation is possible. 4

Installation guide Local Control Network - building controls in perfection Sensor technology The red sensor connecting plugs are protected only in a low extent against overvoltage. A contact with 230V will destroy the module. The sensor terminals are on the N potential, which means they are not decoupled from the electrical isolation. That s why you must make sure, that a protection against contact for the user in every operating condition is ensured. The push-buttons from all of the approved switch panel systems ensure this protection. The module has three sensor connections, which can be used as additional switchings, if necessary as actuator. The functions can be programmed with the setup programme LCN- P or LCN-PRO. T-connection: Over a LCN-T8 or push-button converter (LCN-BT4H/BU4L), max. 8 conventional pushbuttons can be evaluated. Apart from that, there are a selection of sensors that can be connected here alternatively. The module has the required analogue value processing with up to 12bit accuracy. I-connection: Here the IR-receiver for the remote control can be connected, additionally the binary sensor LCN-B3I, the motion detector LCN-BMI, the transponder reader LCN-UT and the temperature sensor LCN-TS. These components can be operated parallel on the I- connection by using the LCN-IV. The I-connection can alternatively be served as a counter for pulses up to 1kHz, when no further periphery is connected. 5

Local Control Network - building controls in perfection Installation guide P-connection: Here you can connect for example, the 4-way binary sensor (LCN-BT4H/-BU4L), the current sensor (LCN-BS4) and the relay blocks (LCN-R8H/-R4M2H/-R2H. The LCN- BT4H/BU4L and LCN-BS4 will be detected automatically. The LCN-R8H has to be activated first with the LCN-P or LCN-PRO. Notes about the sensor technology: The module monitors overloads and short circuits (T-, I-, P-port) on its sensor technology. Should the module be short circuited on its periphery, due to wiring errors, it will switch off the power supply from the sensor for 4 seconds by itself. If 2 further tests show the same error, it will switch off for 8s + 30s and a status message will be sent to the bus: module reports overload/short circuit periphery., apart from that the red LED will flash cyclic, as long as the sensor technology is switched off. In this case check the connected sensor technology and the wiring. The module stays accessible and operational even after these errors! 6

Installation guide Status display of the lamps Local Control Network - building controls in perfection GREEN (flashes constantly): nr. of flashes message 1 normal operation 2 self testing-error, module is not programmed 3 Bus error: module cannot send 4 (reserved) 5 module is in programming mode RED (flashes only when occurances are entered): nr. of flashes message 1 key was pressed, command was sent 2 different errors: please check with PC and the LCN-PRO 3 received telegram data was faulty 4 IR-telegram received from unauthorised sender 5 received illegal command (will be ignored) 6 error in the structure of a received command 7 parameter of a command exceeds permitted limit 8 command received cannot be carried out at the moment cyclic (30s.) periphery (T-,I-, P-Port) was overloaded and/or short circuited. Both LED s left and right side of the T-connection, show switch and dimming conditions of the outputs. 7

Local Control Network - building controls in perfection Installation guide In the menus and help texts found in the programme LCN-PRO, further informations and properties of the module are available. Without parameterization the module has no functions. Because no access to the module is required when first programming, (no programming button, all functions are controlled over the bus), the module may be installed before being setting up. In this case the serial number of the unprogrammed module should be noted in the building plan, for better identification. Note: As always with electronic, suppressor elements (e.g.vdr s) are to be planned with coils from 230V~ contactors and relays, that are installed in the same distribution boxes as the LCN modules. Important note: Despite its extensive functionalities, the LCN system is simple to install and programme: It s all in the hands of the electrician. However a training course is necessary for every electrician, who installs this system. The direct users support over the telephone hotline, is only free of charge and open to installers who have taken part in a training course. 8

Installation guide Local Control Network - building controls in perfection Properties of the built-in control progamme: Issued numbers: group members: command tables: links: scene storage: Timers (amount): outputs (2): keys (4): key blocking (1): output blocking (2x1): clock (1): relay (2): module ID: 5..254, group nr.: 5..254 segment nr.: 5..124 12 (fixed) plus 10 (dynamic) A, B, C & D with each 2 * 8 targets (each 3 commands) and 32 targets at 3 commands (double operation) depending on: logic, time, sensors, outputconditions, panel and fault report-processing (4-way) according to DIN. 10 x 10 per light group (brightness & ramp) 10ms..40 min each 1s.. 45 days each 1s.. 45 days 1s.. 45 days (part & full blockage) 0,3s.. 6500 s 30ms..4 min 9

Local Control Network - building controls in perfection Installation guide Properties of the built-in control progamme: Measured value processing triggering: pre processing: evaluation: counting/computing: Remote control keys: amount access codes: zentral access control: transponder: 8, 10 or 12 bit value correction, hum sound suppression, remote query two continuous controllers input sizes can be calculated as difference values 5 thresholds (=10 commands) with hysteresis 0... 30000, can be cascaded 16 (with LCN-RT: 4 key levels) 250 + serial number evaluation (transponder) > 16 mio codes 16 codes evaluated direct, many over LCN-GVS 10

Installation guide Technical data: Local Control Network - building controls in perfection Connection: power supply: power consumption: terminals/wire type (load side): fuse on the outputs: connection sensor side: 230VAC ± 15%, 50/60Hz (110VAC version available) 0,5W screwless, solid max. 2,5mm² oder fine wire with end sleeves max. 1,5mm² loop through current max. 16A fine-wire fuse 3.15AF both outputs T-, I- und P-connection 11

Local Control Network - building controls in perfection Installation guide Technical data: Outputs: type: triggering: switch load: overload: reactive power: Installation: operating temperature: air humitidy: environmental conditions: protection art: dimensions (BxDxH): installation: zero voltage switch or leading edge dimmer 200 steps in dimming operation each 300VA (cos ö=1) 1kW max. 10s. 1% of the apparent power 0 0-10 C..+ 40 C max. 80% rel., non condensing use as stationary installation according to VDE632, VDE637 IP20 68mm (4HP) x 92mm x 66,5mm DIN rail 35 mm (DIN50022) Technical information and images are non binding. Changes are reserved. Technical hotline: +49 5066 998844 or www.lcn.de 12 D05/2012 ISSENDORFF KG, 31157 Sarstedt