DXP 100 Air Cooled Condenser

Similar documents
DXP 100. Dry Cooler CERTIFY-ALL DX COOLERS

09GDV and 09LDV. Air Cooled Dry coolers and Condensers

PRODUCT SELECTION DATA. Performance. Flexibility. Intelligence. Energy optimisation. Acoustic optimisation. Drycoolers 09PE

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

HTC. Air cooled Condensers. Capacities kw. Ripple Fin tubing Floating coil block suspension

product selection data Performance Flexibility Intelligence Energy optimisation Acoustic optimisation Drycoolers - Air-cooled condensers 09PE

Bifurcated Case Axial Fans (BIFA)

product selection data Slim design Acoustic comfort 40% smaller footprint Drycoolers 09VE

NEOSTAR NEW! Condensers. www. 18 kw 1250 kw

Condensers. 7 kw 198 kw.

ACOUSTIC CABINET FANS CVB / CVT Series

CACC condensers CDCC dry coolers Capacity range kw

Highline 260i EC Waterside Fan Coil Unit

VORTICENT C E RANGE Centrifugal fans

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

CVHT Series - F rated cabinet fans

Acoustic Twin Fans (ATQ)

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels

The World Leading Air-conditioning Company

Performance. Sound Levels. Impellers. Motors. Accessories

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

ACOUSTIC CABINET FANS CVAB / CVAT Series

ROOFMASTER STEF-HT ROOF FAN

MAJAX-2 GENERAL SPECIFICATION

09DK054, 064, 074, 084, 094 AIR-COOLED CONDENSERS

AXIAL FANS Catalogue CN0050C01 May 2008

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows

AlfaGreen - Dry Coolers DC DCD DCV

HEATING & COOLING COIL PRODUCTS

ENR Incorporating

LSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS

AQVSL/AQVSH STAR 85 to 140

Medium Pressure Centrifugal Fans

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Multifunctional 400ºC/2h and 300ºC/2h roof fans

CornerAir. CornerAir. Active chilled beam

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw

DIRECT-AIR ILB / ILT Series Rectangular duct fans

CMTE. Tangential Fan Coil Series with Electronic Controlled Motor

Integreret Combi Cooler system Energieffektiv ventilation og køling. FCUA Fancoil

OptimAir NF. Active Chilled Beam OptimAir NF. Nov

PCXDMT1601. VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ. Heat Pump 50/60 Hz R-410A

NEW WINDER. Impellers with higher efficiency and less sound level

CENTRIFUGAL FAN COIL UNIT VCE

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

ARW DRY COOLERS AXIAL FANS VERSION, MEDIUM AND HIGH CAPACITY. CAPACITY FROM 20 TO 775 kw ARW DRY COOLERS

Industrial air cooler VCI Cooling/Freezing

Kitchen exhaust fan GLEB

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

Sentinel D-Box Single Fan

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03

^áêëçåâ=ìåáí=åççäéêë=qvoj^ pí~åç~êç=åççäéêë=ïáíü=pí~áåäéëë=píééä=íìäáåö

Galaxy TM In-Line Belt Driven Twin Fans (GDB)

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

Mixed Flow Roof Fans (RMH)

Mixed Flow Roof Fans (RMH)

Industrial air coolers for cooling & freezing applications Cu/Al

fåçìëíêá~ä=~áê=åççäéêë=qvo pí~åç~êç=åççäéêë=ïáíü=ëí~áåäéëë=ëíééä=íìäáåö

BELT DRIVEN CABINET FANS CVTT Series

PCXAU1601. VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ. Heat Pump 50/60 Hz R-410A

Sentinel D-Box Twin Fan

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

Terminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications.

Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB)

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

HEATING & COOLING COIL PRODUCTS AIR COOLED CONDENSERS

BRIZA 22 HYBRID HEATING & COOLING

PRODUCT CATALOGUE CHILLER ECOMAX

FDCLP2 Constant Volume Series Flow, Low Profile

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C)

High Pressure Centrifugal Pumps Product Overview

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

Chassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

MUC-LUC. Unit Coolers. 1 kw 13,7 kw

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

TVFC Dry and adiabatic cooling

Sabre Plate Mounted Sickle Fans (VSP)

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

RCTM. Condensor, kw. RC Low up to 66 kw. RC Mid&High up to 1200 kw. Quick facts. General

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

HIGH-POWERED VENTILATORS

Plate mounted axial flow fans HXBR / HXTR Series

Unit Coolers MUC-LUC. 1 kw 13,7 kw.

GigaBox centrifugal fans Product specific information

Axial fans 400ºC/2h and 300ºC/2h With soundproofed box. Extraction units with axial fans to work inside fire danger zones.

Alfa Laval Optigo CS. Commercial air coolers - Slim line

CGA CXA VGA VXA CG-PRC006-E4

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

Transcription:

Air Cooled Condenser Applied for CERTIFY-ALL DX COOLERS

PRESENTATION The coolers are designed for outdoor applications. All technical data are based on different mixtures of cooling media i.e.ethylene glycol mixture. The coolers can be used for othermediums which do not attack copper. is available in 15 sizes with velocities 865, 670, 450 and 355 r/min. DESIGN Model have vertical airflow. Casings and the supporting structure are made of aluminium and hot galvanised steel. The coil is manufactured from copper tubes with mechanically bonded collar spaced aluminium fins. The fin spacing of 2,5mm is relatively wide which makes the cooler less sensitive to air side fouling leading to reduced performance. The fans (two ) are direct driven by 3-phase 400V/50Hz, to IEC standard with protection to IP54. The fans are separated in pairs by partition walls, which makes it possible to regulate the capacity by separate running of the fans. The can be regulated by voltage transformer or frequency converters with sine filters for all poles. INSTALLATION The coolers can be floor or roof mounted. Each leg has adrilled hole, so that the cooler can be fixed via retaining bolts. Electrical connections are made through externally mounted 3-pol-safety breakers this is valid on all models. The rating plate on each unit, details the motordata and electrical connection at incoming air +20 C and max Ampere at -30 C. When sizing the overload protection Pls. see instructions. Overload protection shall have a range at +/- 20%. The cooler should be fixed directly onto the ground by fixing bolts or securred an a framework with anti vibration pads to obtain best sound spectra. CAPACITY For calculating capacity, see AIA Calc computer program. on page 2 is based on Eurovent standard EN 1048; Air inlet temperature 25 C, liquid temperatures inlet/outlet 40/35 C, water. OPTIONS Epoxy coated fins Copper fins MODEL DESCRIPTION Powder coated chassis Water spray nozzles Flanges PN16 7 A 256 X Options over and above standard Dry Cooler Size passes A= 865 r/min Δ3/400 V B=670 r/min Y3/400 V C=450 r/min Δ3/400 V D=355 r/min Y3/400 V 2

MAIN DATA Cooling Tube vol-weighume 1) surface TECHNICAL DATA Shipping volume A Standard No of passes B C Alternative number of passes D Alt.1 Alt. 2 Alt. 3 Alt. 4 Alt. 5 m 2 dm 3 kg m 3 1 922 296 1022 21,0 128 85 85 64 64 85 128 256 170* 2 1153 342 1131 21,0 106 106 80 80 80 106 160 320 212* 3 1383 385 1240 21,0 128 128 96 96 96 128 192 384 256* 4 1383 379 1452 30,5 128 128 128 85 64 85 128 256 170* 5 1729 446 1613 30,5 160 160 106 106 80 106 160 320 212* 6 2075 509 1774 30,5 192 192 128 128 96 128 192 384 256* 7 1844 464 1883 39,5 256 256 128 128 64 85 128 256 170* 8 2305 554 2096 39,5 320 160 160 160 80 106 160 320 212* 9 2766 638 2309 39,5 384 192 192 128 96 128 192 384 256* 10 2305 550 2320 49,0 256 256 256 128 64 85 128 256 170* 11 2881 660 2584 49,0 320 320 320 160 80 106 160 320 212* 12 3456 766 2849 49,0 384 384 192 192 96 128 192 384 256* 13 2766 636 2750 58,5 256 256 256 256 64 85 128 256 170* 14 3458 766 3067 58,5 320 320 320 320 80 106 160 320 212* 15 4149 894 3384 58,5 384 384 384 192 96 128 192 384 256* 1) Dry weight * Connection opposite side Motor Rating Δ/3/400V 50Hz Fan A kw 1) 865 r/min 1,6 kw 2) 4 A 3) m 3 /s 1 282 21,9 4 2 312 21,7 4 3 327 21,4 4 4 431 32,9 6 5 467 32,5 6 6 491 32,1 6 7 565 43,9 8 8 613 43,4 8 9 647 42,8 8 10 713 54,8 10 11 773 54,2 10 12 814 53,6 10 13 860 65,8 12 14 934 65,0 12 15 982 64,3 12 Motor Rating Y/3/400V 50Hz Fan B kw 1) 670 r/min 0,92 kw 2) 2 A 3) m 3 /s 1 237 16,9 4 2 254 16,7 4 3 263 16,5 4 4 355 25,4 6 5 380 25,1 6 6 395 24,8 6 7 466 33,9 8 8 510 33,5 8 9 530 33,0 8 10 589 42,3 10 11 630 41,8 10 12 656 41,3 10 13 710 50,8 12 14 760 50,2 12 15 790 49,6 12 Motor Rating Δ/3/400V 50Hz Fan C kw 1) 450 r/min 0,29 kw 2) 0,86 A 3) m 3 /s 1 176 11,4 4 2 184 11,3 4 3 188 11,1 4 4 263 17,2 6 5 277 16,9 6 6 282 16,7 6 7 354 22,9 8 8 368 22,6 8 9 376 22,2 8 10 436 28,6 10 11 456 28,2 10 12 471 27,8 10 13 526 34,3 12 14 550 33,8 12 15 561 33,4 12 1) is based on EN 1048; Air inlet temperature 25 C, liquid temperatures inlet/outlet 40/35 C, water. 2) rating is valid air temperature of 20 C. 3) The motor rating is valid at air inlet temperature of -30 C. Motor Rating Y/3/400V 50Hz Fan D 355 r/min 0,18 kw 2) 0,42 A 3) kw 1) m 3 /s 1 145 9,0 4 2 150 8,9 4 3 152 8,8 4 4 218 13,5 6 5 225 13,4 6 6 228 13,2 6 7 290 18,0 8 8 300 17,8 8 9 304 17,6 8 10 364 22,5 10 11 375 22,3 10 12 380 22,0 10 13 433 27,1 12 14 447 26,7 12 15 456 26,4 12 3

SOUND LEVEL L p 1) L w 2) 2) L w Octave band db L p 1) L w 2) 2) L w Octave band db Hz 63 125 250 500 1k 2k 4k Fan A, 865 r/min Fan C, 450 r/min 63 125 250 500 1k 2k 4k Fan B, 670 r/min 1 58 91 101 92 89 86 86 83 71 52 84 91 82 82 80 81 76 62 2 58 91 101 92 89 86 86 83 71 52 84 91 82 82 80 81 76 62 3 58 91 101 92 89 86 86 83 71 52 84 91 82 82 80 81 76 62 4 60 92 103 94 91 88 88 85 73 53 86 93 84 83 82 83 77 64 5 60 92 103 94 91 88 88 85 73 53 86 93 84 83 82 83 77 64 6 60 92 103 94 91 88 88 85 73 53 86 93 84 83 82 83 77 64 7 61 94 105 95 92 89 89 86 74 54 87 94 85 85 83 84 79 65 8 61 94 105 95 92 89 89 86 74 54 87 94 85 85 83 84 79 65 9 61 94 105 95 92 89 89 86 74 54 87 94 85 85 83 84 79 65 10 62 95 105 96 93 90 90 87 75 55 88 95 86 86 84 85 80 66 11 62 95 105 96 93 90 90 87 75 55 88 95 86 86 84 85 80 66 12 62 95 105 96 93 90 90 87 75 55 88 95 86 86 84 85 80 66 13 62 95 106 97 94 91 91 88 76 56 89 96 87 86 85 86 80 67 14 62 95 106 97 94 91 91 88 76 56 89 96 87 86 85 86 80 67 15 62 95 106 97 94 91 91 88 76 56 89 96 87 86 85 86 80 67 Fan D, 355 r/min 1 43 75 78 74 80 70 70 62 49 35 67 70 68 68 65 63 55 41 2 43 75 78 74 80 70 70 62 49 35 67 70 68 68 65 63 55 41 3 43 75 78 74 80 70 70 62 49 35 67 70 68 68 65 63 55 41 4 44 77 79 76 81 72 72 64 51 36 69 72 70 69 66 65 57 43 5 44 77 79 76 81 72 72 64 51 36 69 72 70 69 66 65 57 43 6 7 44 45 77 78 79 81 76 77 81 83 72 73 72 73 64 65 51 52 36 37 69 70 72 73 70 71 69 71 66 68 65 66 57 58 43 44 8 45 78 81 77 83 73 73 65 52 37 70 73 71 71 68 66 58 44 9 45 78 81 77 83 73 73 65 52 37 70 73 71 71 68 66 58 44 10 46 79 82 78 84 74 74 66 53 38 71 74 72 72 69 67 59 45 11 46 79 82 78 84 74 74 66 53 38 71 74 72 72 69 67 59 45 12 46 79 82 78 84 74 74 66 53 38 71 74 72 72 69 67 59 45 13 47 80 82 79 84 75 75 67 54 39 72 75 73 72 69 68 60 46 14 47 80 82 79 84 75 75 67 54 39 72 75 73 72 69 68 60 46 15 47 80 82 79 84 75 75 67 54 39 72 75 73 72 69 68 60 46 1) Sound pressure level Lp, rel. 2 x 10-5 Pa is the A-weighted average sound pressure level on an enveloping area in the shape of a parallelepiped at the distance of 10 m. 2) Sound power level Lw, rel. 10-12 W determined by measurement of sound intensity in accordance with ISO 9614-2. Hz Correction at other distance The diagram shows reduction of db (Lp) at distances over 10 m. -30-25 -20-15 Reduction (db) -10-5 10 20 30 40 50 200 Distance (m) 4

DIMENSION AND WEIGHT OUT OUT 2410 IN = = *B *C *D *E *F *1620 *1900 A 2400 * Holes Ø 18 mm Distance between connections on request Vents are placed on top and bottom of headers. Dimensions in mm A B C D E F 1 3610 1590 - - - - 2 3610 1590 - - - - 3 3610 1590 - - - - 4 5200 1590 1590 - - - 5 5200 1590 1590 - - - 6 5200 1590 1590 - - - 7 6790 1590 1590 1590 - - 8 6790 1590 1590 1590 - - 9 6790 1590 1590 1590 - - 10 8380 1590 1590 1590 1590-11 8380 1590 1590 1590 1590-12 8380 1590 1590 1590 1590-13 9970 1590 1590 1590 1590 1590 14 9970 1590 1590 1590 1590 1590 15 9970 1590 1590 1590 1590 1590 CONNECTION DIMENSIONS Tube connections at alternative passes page 2 Flange connections at alternative passes page 2 Alt.1 Alt. 2 Alt. 3 Alt. 4 Alt. 5 Alt.1 Alt. 2 Alt. 3 Alt. 4 Alt. 5 1 2+2 76 2+2 76 2+2 88 4+4 4+4 * 2+2 DN65 2+2 DN65 2+2 DN80 4+4 DN 4+4 DN* 2 2+2 76 2+2 88 2+2 4+4 4+4 * 2+2 DN65 2+2 DN80 2+2 DN 4+4 DN 4+4 DN* 3 2+2 76 2+2 88 2+2 4+4 4+4 * 2+2 DN65 2+2 DN80 2+2 DN 4+4 DN 4+4 DN* 4 2+2 76 2+2 76 2+2 88 4+4 4+4 * 2+2 DN65 2+2 DN65 2+2 DN80 4+4 DN 4+4 DN* 5 2+2 76 2+2 88 2+2 4+4 4+4 * 2+2 DN65 2+2 DN80 2+2 DN 4+4 DN 4+4 DN* 6 2+2 76 2+2 88 2+2 4+4 4+4 * 2+2 DN65 2+2 DN80 2+2 DN 4+4 DN 4+4 DN* 7 2+2 76 2+2 76 2+2 88 4+4 4+4 * 2+2 DN65 2+2 DN65 2+2 DN80 4+4 DN 4+4 DN* 8 2+2 76 2+2 88 2+2 4+4 4+4 * 2+2 DN65 2+2 DN80 2+2 DN 4+4 DN 4+4 DN* 9 2+2 76 2+2 88 2+2 4+4 4+4 * 2+2 DN65 2+2 DN80 2+2 DN 4+4 DN 4+4 DN* 10 2+2 76 2+2 76 2+2 88 4+4 4+4 * 2+2 DN65 2+2 DN65 2+2 DN80 4+4 DN 4+4 DN* 11 2+2 76 2+2 88 2+2 4+4 4+4 * 2+2 DN65 2+2 DN80 2+2 DN 4+4 DN 4+4 DN* 12 2+2 76 2+2 88 2+2 4+4 4+4 * 2+2 DN65 2+2 DN80 2+2 DN 4+4 DN 4+4 DN* 13 2+2 76 2+2 76 2+2 88 4+4 4+4 * 2+2 DN65 2+2 DN65 2+2 DN80 4+4 DN 4+4 DN* 14 2+2 76 2+2 88 2+2 4+4 4+4 * 2+2 DN65 2+2 DN80 2+2 DN 4+4 DN 4+4 DN* 15 2+2 76 2+2 88 2+2 4+4 4+4 * 2+2 DN65 2+2 DN80 2+2 DN 4+4 DN 4+4 DN* * Connection opposite side 5

Asarums Industri AB S. Industrivägen 2-4, SE-374 50 Asarum, Sweden, Tel +46 454 334 00, Fax +46 454 32 02 95 60158/1 Knoester Reklam 08-0210