Instruction Manual. Electrobloc EBL 40 B

Similar documents
Instruction Manual. Caravan Charging System CSV 404. Table of contents

Instruction Manual. Electroblock EBL 119 EBL 119 with OVP. Table of contents

Instruction manual. Electrobloc EBL 109-6

Instruction manual. CSV 402 caravan power supply. Table of contents

Operating Instructions

Installation instructions. Adapter AD 01 AD 02 AD 03

Instruction Manual. Caravan Charging System CSV 414. Table of contents

Instruction manual. Electrobloc EBL 269

Instruction manual. 0 manual for LT A control and switch panel. Table of contents

Instruction Manual. Control and Display Panel DT 220 C. Table of contents

Operating Instruction Manual of Energy Management System EBL 208, Art.-No Seite 1 / 7

Operating Instruction Manual for Energy Management System EBL 99 C, Art.-Nr Seite 1 / 7

Instruction manual. 0 Manual Control and Switch Panel DT 201 B. Table of contents

TRADE PRODUCTS. Electronic systems for recreational vehicles Supplying controlling indicating

Operating Instruction Manual for Instrument Panel IT 992 Art.-Nr Page 1 / 5

Smart Battery Charger

PURE SINE WAVE DC TO AC POWER INVERTER


Multi-Mover Charger for model L25

HST-BL-2830MS & HST-BL-2830MS-USA

DIAGNOSTIC POWER SUPPLY WSC 720. user guide. 12 V/24 V lead acid batteries ah

Wilo-Control SC-Fire Jockey

Battery charger , A, B

CX-SERIES ADVANCED BATTERY CHARGER

original operating manual Operating manual Translation of the Item-No.: ,

AUTOMATIKLADER AL 12/10 AL 12/15 AL 24/8

DC Master 24/ A

FLUDEX - thermal switching equipment. Operating instructions BA en 04/2012. FLENDER couplings

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

innovations in battery charging

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

Battery Charger. Series EASY Charger. User s manual

USER GUIDE 12 V Lead acid batteries Ah

USE AND INSTALLATION HANDBOOK

Safety Precautions. Damages resulting from failure to observe these safety precautions are exempt from any legal claims whatever.

Operating Instructions

Cruising Charger Series OWNER S MANUAL

User s Manual. Automatic Switch-Mode Battery Charger

SBC / 2140 / Stage Battery Charger User Manual

AUTOMATIKLADER AL 12/30 AL 12/45 AL 12/60 AL 24/30 AL 24/60. Operating Instructions AL

User Manual Rittal PMC UPS 6kVA

Installation Manual for D154X Series Multi-Indicator, General Purpose Power Supplies

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

FUM-24xxCBP Series 3 Stage Battery Charger User Manual

EC200 ELECTRONIC CONTROL SYSTEM

Battery Charger Series EASY Charger

Sinewave Inverters. SWING 150VA and 300VA. User s manual

C3 Operating Instructions

ADN-W L 10. Battery Charger. Instruction manual

c-go 24V/6A 24V/8A 24V/12A

Swing Piston Compressors and Vacuum Pumps

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

Mod: KLD6-12/35XLAS-N

Operating manual. original operating manual. HDA eco Box 12/24V DC Automatic Dispenser. Translation of the. Item No.:

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A

MP V 8A Electronic Smart Charger. Instruction and Information Manual

EC400 Power Control System

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

Instruction manual. Liftkar HD Uni Liftkar HD Fold Liftkar HD Dolly Liftkar HD Fold Dolly. Issued: 10/2010 subject to updates.

EC225 Power Control System

SBC V In-Car Charger Dual Input (Solar MPPT & DC)

MANUAL. Single charger

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC AP

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Oil-free piston compressors KK and piston vacuum pumps KV

FLENDER ARPEX Plate packs with close-fitting bolt connection. ARW-4 Sizes to Assembly instructions An 4239 en 12/2015.

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

Instruction Manual. Sewage lifting station compli 300

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

USER MANUAL MPS 1-5KW SERIES

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

BellMega BM-510. Operation Manual Ver: 1.0 Rev: 1

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

Phocos CML-V2. Solar charge controller. User Manual (English) Dear customer,

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

2603 Battery Pal 3 AMP, 1 2 VOLT BATTERY CHARGER

Sinewave Inverters. SWING pro 200VA and 350VA. User s manual

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

NEW SOLAR CHARGE CONTROLLERS

Battery Charger XT EXTENDED. For lead-acid batteries. User Manual and Guide to professional charging of starter and deep cycle batteries.

Your new LM controller is a state-of-the art device which was developed in accordance with the latest

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

SCOPELITE TIMING LIGHT OPERATING MANUAL

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Sinewave Inverters. Jazz 700VA and 1000VA. User s manual

DC-DC STEP DOWN CONVERTER CV 24/12V - 15 A Pro

Installation and Connection: Installation and Operating Manual

MPPT5012A-DUO-BT MPPT5025A-DUO-BT

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

SAVE THESE INSTRUCTIONS

Sentry Battery Charger. Installation and Operations Manual Section 75

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

Installation manual. Modbus Interface DIII EKMBDXA7V1. Installation manual Modbus Interface DIII. English

User Manual TABLE MAGNIFIER TL-70. User-friendly Manual ID: #05007

Softstarter SAS SAS 11PUST, 22PUST Assembly- and Commissioning Instructions

10 AMP ON BOARD BATTERY CHARGER

Whad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF

Transcription:

Instruction Manual Electrobloc EBL 40 B Table of contents 1 Safety Information... 2 1.1 Meaning of safety symbols... 2 1.2 General safety information... 2 2 Introduction... 3 3 Operation... 3 3.1 Starting up the system... 3 3.2 Changing the battery... 4 3.3 System faults... 5 3.4 Closing down the system... 7 4 Application and functions in detail... 8 4.1 Battery functions... 9 4.2 Additional functions... 9 5 Maintenance... 10 Appendix... 11 E Schaudt GmbH, Elektrotechnik und Apparatebau, Planckstraße 8, 88677 Markdorf, Germany, Tel. +49 7544 9577-0, ax +49 7544 9577-29, www.schaudt -gmbh.de 811.599 BA / EN Date: 15.06.2010

1 Safety information 1.1 Meaning of safety symbols Y DANGER! ailure to heed this warning may result in death or serious injury. Y WARNING! ailure to heed this warning may result in personal injuries. Y ATTENTION! ailure to heed this warning may result in damage to the device or connected consumers. 1.2 General safety information The device is state-of-the-art and complies with approved safety regulations. Nonetheless, personal injuries or damage to the device may occur if the safety instructions contained herein are not followed. Ensure that the device is in perfect working order before use. Any technical faults which may impact personal safety or the safety of the device must be rectified immediately by qualified personnel. Y DANGER! 230 V mains voltage carrying parts. Danger of death due to electric shock or fire: Do not carry out maintenance or repair work on the device. If cables or the device housing are damaged, no longer use the device and isolate from the power supply. Ensure that no liquids enter the device. Y WARNING! Hot components! Burns: Only change blown fuses when the device is completely de-energised. Only replace blown fuses once the cause of the fault has been identified and rectified. Never bypass or repair fuses. Only use original fuses rated as specified on the device. Device parts can become hot during operation. Do not touch. Never store heat sensitive objects close to the device (e.g. temperature sensitive clothes if the device has been installed in a wardrobe). 2 Date: 15.06.2010 811.599 BA / EN

2 Introduction This instruction manual contains important information for safe operation of the device. Make sure you read and follow the safety instructions provided. The instruction manual should be kept in the vehicle at all times. Ensure that other users are made aware of the safety regulations. 3 Operation The electrobloc is operated exclusively via the IT/LT... control and switch panel connected. The EBL 40 B electrobloc does not require attendance for daily operation. Initial setting is only needed after the type of battery (lead-acid or lead-gel) has been changed or during commissioning or when upgrading with accessories (see section 3.2 and EBL 40 B installation instructions for details). 3.1 Starting up the system Y ATTENTION! Incorrect electrobloc settings. Damage to connected devices. Therefore prior to starting: Ensure the leisure battery is connected. Make sure the battery selector switch (fig. 3, pos. 1) is set to the correct position for the battery inserted. Make sure the AES fuse (fig. 3, pos. 6, with 15 A fuse and labelled KS ) is only used in conjunction with a connected AES refrigerator. Otherwise the leisure battery may totally discharge. Damage to the battery is possible. Use the 12 V main switch (see instruction manual of relevant control and switch panel) to switch on/off all the consumers and the control and switch panel. The outputs are exceptions: rost protection valve Refrigerator controller loor light Spare 1 Awning light AES/compressor refrigerator or further information, see the instruction manual of the IT/LT... control and switch panel.. 811.599 BA / EN Date: 15.06.2010 3

Generator operation and passenger vehicle ferries ATTENTION! Exceeding the threshold values of the 230 V mains supply! Damage to the electrobloc, 12 V consumers or connected devices: Y It is essential that the generator conforms to the specifications of the mains supply. Only connect up the generator when it is running smoothly. Do not connect the electrobloc to the mains supply on board passenger vehicle ferries (correct mains supply is not always guaranteed on board these ferries). 3.2 Changing the battery ATTENTION! Use of incorrect battery types or incorrectly rated batteries. Damage to the battery or devices connected to the electrobloc: Y Batteries should only be changed by qualified personnel. ollow the instructions provided by the battery manufacturer. Only connect the electrobloc to 12 V power supplies with rechargeable 6-cell lead-gel or lead-acid batteries. Do not use any unsuitable battery types. Y Y Only batteries of the same type and capacity should normally be used, i.e. same as those installed by the manufacturer. It is possible to swap lead-acid batteries with lead-gel batteries. However, swapping from lead-gel batteries to lead-acid batteries is only possible in certain circumstances. Contact the vehicle manufacturer for more information. Changing the battery " Electrically disconnect the battery from the electrobloc. To do this, enable battery isolation on the IT/LT... control and switch panel (also see section 3.1). " Replace battery. " After changing the battery, recheck which type of battery has been inserted. Y DANGER! Incorrect setting of the battery selector switch. Risk of explosion due to build up of explosive gases: Set the battery selector switch to the correct position. " Disconnect the electrobloc from the mains before adjusting the battery selector switch. 4 Date: 15.06.2010 811.599 BA / EN

1 ig. 1 Battery selector switch " Set the battery selector switch (fig. 1, pos. 1) to the correct position using a thin object (such as a ballpoint pen): Lead-gel battery: Set the battery selector switch to Lead-gel. Lead-acid battery: Set the battery selector switch to Lead-acid. Starting up the system " Start up the system as described in section 3.1. 3.3 System faults lat vehicle fuses Polyswitch fuses A fault in the power supply system is usually caused by a blown fuse. Please contact our customer service department if you cannot rectify the fault using the following table. If this is not possible, e.g. if you are abroad, you can have the electrobloc repaired at a specialist workshop. Please note that the warranty will become void if incorrect repair work is carried out. Schaudt GmbH shall not accept liability for any damages resulting from such repairs. The following outputs are protected by a polyswitch fuse: loor light/step Awning light If these outputs are dead, switch off the electrobloc for approx. 1 min. and disconnect it from the 230 V supply. The polyswitch fuses reset automatically during this period. ault Possible cause Remedy Living area battery is not charged during 230 V operation (battery voltage constantly below 13.3 V) Living area battery is overcharged during 230 V operation (battery voltage constantly above 14.5 V) No mains voltage Too many consumers are switched on Defective electrobloc Defective electrobloc Switch on the automatic circuit i breaker in the vehicle; check the mains voltage Switch off consumers not required Contact the customer service department Contact the customer service department 811.599 BA / EN Date: 15.06.2010 5

ault Starter battery is not charged during 230 V operation (battery voltage constantly below 13.0 V) Living area battery is not charged during mobile operation (battery voltage below 13.0 V) The living area battery is overcharged during mobile operation (battery voltage constantly above 14.3 V) The refrigerator does not work during mobile operation Certain outputs are dead Possible cause No mains voltage Too many consumers are switched on Defective electrobloc Defective alternator No voltage on D+ input D+ switch on the electrobloc is set incorrectly. Defective electrobloc Defective alternator No power supply to the refrigerator Defective electrobloc Defective refrigerator Polyswitch fuse has tripped Remedy Switch on the automatic circuit i breaker in the vehicle; check the mains voltage Switch off consumers not required Contact the customer service department Check the alternator Check the fuse and wiring Set the switch according to the D+ signal from the vehicle (12 V or active ground) Contact the customer service department Check the alternator Check the fuse (15 A of supply; possibly 1A of D+ signal) and wiring Contact the customer service department Check the refrigerator Completely switch off the electrobloc Determine and rectify the cause Switch on the electrobloc after approx. 1 min. 12 V supply does not work 12 V main switch for the 12 V main switch for the in the living area living area battery is living area battery must be switched off switched on Operation of the electrobloc not possible via the IT/LT... control and switch panel. Not all the connectors have been connected to the electrobloc Defective fuse or wiring Defective electrobloc Defective electrobloc Connect all the connectors to the electrobloc Check fuse and wiring Contact the customer service department Contact the customer service department Y Y If the device becomes too hot due to excessive ambient temperature or lack of ventilation, the charging current is automatically reduced. Nevertheless, always prevent the device from overheating. If the automatic shutdown mechanism of the battery monitor is triggered, fully charge the living area battery. 6 Date: 15.06.2010 811.599 BA / EN

3.4 Closing down the system A battery is isolated by disconnecting the plug connectors. Y ATTENTION! Total discharge. Damage to the living area battery: ully charge the living area battery before and after closing down the system. (Connect a vehicle with an 80 Ah battery and a vehicle with a 160 Ah battery to the mains for at least 12 and 24 hours respectively). Closing down the system for up to 6 months Closing down the system for more than 6 months " ully charge the living area battery before closing down the system. The living area battery is then protected against total discharge. This only applies if the battery is intact. ollow the instructions provided by the battery manufacturer. Disconnect the living area battery from the 12 V power supply if the motorhome is not used for a longer period (during the winter for example). " ully charge the living area battery before closing down the system. " Disconnect the plug connectors on block 7 and block 10 of the EBL 40 B. 811.599 BA / EN Date: 15.06.2010 7

4 Application and functions in detail The EBL 40 B electrobloc is the central power supply unit for all 12 V consumers in the vehicle s electrical system. It is usually located in a cupboard or storage space and is accessible from the front in order to change fuses. Control and display panel IT.../LT... Electrobloc EBL 40 B 230 V AC ig. 2 12V consumers On-board power supply system Lighting Pump Heater etc. + -- Starter battery + -- Living area battery Modules The EBL 40 B electrobloc contains: a charger module for charging all connected batteries the complete 12 V distribution the fuses for the 12 V circuits System devices An IT... or LT... control and switch panel must be connected for operation. These devices control the electrical functions in the vehicle s living area, including accessories. lat vehicle fuses protect the various circuits. The exceptions (these circuits are protected by polyswitch fuses): Step loor light rost protection valve Refrigerator controller Awning light D+ outputs Charger module protective circuits Excess temperature Overload Short circuit Mains connection Current-carrying capacity 230 V AC ± 10 %, 47 to 63 Hz sinusoidal, protection class I 12 V outputs may be loaded with max. 90% of the rated current of the respective fuse (also see front panel). 8 Date: 15.06.2010 811.599 BA / EN

4.1 Battery functions Instruction Manual for Electrobloc EBL 40 B Suitable batteries Battery charging during mobile operation Battery isolation 6-cell lead-acid or lead-gel batteries, 55 Ah and above Simultaneous charging of the starter battery and the living area battery via the alternator, parallel connection of the batteries via a cut-off relay A battery is isolated by disconnecting the two plug connectors on block 7 and block 10 of the EBL 40 B. This prevents the living area battery from slowly discharging due to closed circuit current while the vehicle is not in use. Battery selector switch Standby current from living area battery (without consumer currents) The switching option provided by the battery selector switch ensures optimum charging of the two battery types, lead-gel and lead-acid. With IT/LT... control and switch panel approx. 0.3... 3.5 ma (depending on the control and switch panel being used) under the following conditions: No mains connection Living area battery voltage 12.6 V 12 V main switch O Without battery alarm (e.g. when using LT410) Battery charging via mains connector Living area battery Characteristic charging curve inal charge voltage Charging current Voltage for float charge Starter battery Charging current float charge IUoU 14.3 V 18 A 13.8 V with automatic switch function max. 2 A 4.2 Additional functions Automatic switch function for AES/compressor refrigerator Awning light D+ signal This relay supplies the AES/compressor refrigerator with power from the starter battery when the vehicle engine is running and the D+ connection is live. An AES refrigerator is powered by the living area battery when the vehicle engine is not running. The power supply to this consumer is automatically interrupted as soon as the engine starts running (the D+ connection is live in this case or switched to ground, depending on the type of vehicle). The awning light can still be used even if the 12 V power supply is switched off. The conventional D+ signal (D+ connection is live when the engine is running) is evaluated directly (maximum load 0.2A). An integrated D+ converter enables the connection of vehicles for which the D+ signal is provided as an active ground signal (e.g. IAT). A selector switch on the electrobloc specifies which D+ signal is to be evaluated. Mains charging of the starter battery This feature provides an automatic max. 2 A float charge for the starter battery when the 230 V mains is connected to the electrobloc. 811.599 BA / EN Date: 15.06.2010 9

5 Maintenance The EBL 40 B electrobloc requires no maintenance. Cleaning Clean the electrobloc with a soft, slightly damp cloth and mild detergent. Never use spirit, thinners or similar substances. Do not allow liquids to enter the electrobloc. E No part of this manual may be reproduced, translated or copied without express written permission. 10 Date: 15.06.2010 811.599 BA / EN

Appendix A EC Declaration of Conformity Schaudt GmbH hereby confirms that the design of the EBL 40 B electrobloc complies with the following relevant regulations: -- DIRECTIVE 2006/95/EC O THE EUROPEAN PARLIAMENT AND COUNCIL from 12.12.2006 for the harmonization of the legal provisions of member states in regard to electrical equipment for use within particular voltage limits -- DIRECTIVE 2004/108/EC O THE EUROPEAN PARLIAMENT AND COUNCIL from 15.12.2004 for the harmonization of the legal provisions of member states in regard to electromagnetic compatibility and for the annulment of directive 89/336/EEC -- Law on the electromagnetic compatibility of equipment from ebruary 26th 2008 Manufacturer Address Schaudt GmbH, Elektrotechnik & Apparatebau Planckstrasse 8 88677 Markdorf Germany B Switch panel Special fittings/accessories Schaudt IT/LT... switch panel (required for operation) C Customer service address Customer service Schaudt GmbH, Elektrotechnik & Apparatebau Planckstrasse 8 D-88677 Markdorf tel.: +49 7544 9577-16 e-mail: kundendienst@schaudt-gmbh.de Office hours Mon to Thurs 08.00 -- 12.00, 13.00 -- 16.00 ri 08.00 -- 12.00 Send in the device Returning a defective device: " ill in and enclose the fault report, see Appendix D. " Send it to the addressee (free of charge). 811.599 BA / EN Date: 15.06.2010 11

D ault report In the event of damage, please return the defective device together with the completed fault report to the manufacturer. Device type: Article no.: Vehicle: Manufacturer: Model: Own installation? Yes - No - Upgrade? Yes - No - Upstream overvoltage protection? Yes - No - ollowing fault has occurred (please tick): - Electrical consumers do not work -- which? (please specify below) - Switching on and off not possible - Persistent fault - Intermittent fault/loose contact Other remarks: 12 Date: 15.06.2010 811.599 BA / EN

E Design 11 12 10 9 8 7 6 5 4 3 2 1 ig. 3 Layout of the EBL 40 B electrobloc 1 2 Selector switch for acid/gel battery IT/LT... control and switch panel connection 3 Starter battery connection 4 5 Living area battery connection Terminal block spare/, floor light, battery sensor 6 7 lat vehicle fuses Terminal block D+, consumers, refrigerator 8 9 Adhesive label connections D+ signal selector switch 10 11 Type plate Housing 12 Mounting brackets 811.599 BA / EN Date: 15.06.2010 13

Block diagram/connection diagram BL10 Header MSQ/0 7 Plug -in cable 6.3 x 0.8 3G1.5 L=1.2m 230 V 50 Hz Charger modulemainboard Charger modulecontrol board BL4 Plug connector L -PA 401 6.3x0.8-4-way + rost protection valve + Refrigerator controller + Sensor WB (ext. fuse 2 A) - Sensor WB Selector switch lead-gel/ lead-acid + Sensor WB 12 V O 12 V ON + Mains 12 V indicator +SB - Sensor WB BL6 Plug connector L -PA 401 6.3x0.8-4-way + Spare 1 + loor light/step - Spare 1 - loor light/step BL8 Molex Minifit SR -2 - WB +WB (Ext. fuse max. 40 A) BL1 Plug connector L -PA 401 6.3x0.8-6-way + Refrigerator - Refrigerator - SB refrigerator + SB refrigerator (ext.fuse15a) + Awning light +Pump BL5 Plug connector L -PA 401 6.3x0.8-4-way + Spare 2a + Spare 2b - Spare 2a - Spare 2b Only use fuse for AES or compressor refrigerator BL7 Molex Minifit SR -2 - SB +SB (Ext. fuse max. 40 A) BL2 Plug connector L -PA 401 6.3x0.8-6-way D+ output max. 0.2 A D+ output - TV - Pump - Awning light +TV BL3 Plug connector L -PA 401 6.3x0.8-6-way D+ input *** - rost protection valve - Refrigerator controller - Light 1a - Light 1b + Light 1a + Light 1b *** 2 operating modes: With engine running, alternator signal D+ input goes...... to +12 V (D+) ext. fuse 1A... to GND (D+(ag)) no ext. fuse ag = active ground 14 Date: 15.06.2010 811.599 BA / EN