Similar documents
Datasheet. Flamcomat - Pressureless Expansion System

The Mikrofill Electronic Filling Device. (EFD)

Flamcomat Pump Sets, operating range. System Pressure P [bar] Boiler Output [MW] / Cooling Capacity [MW] = Boiler Output x 2.42

Installation & Technical Guide. Domestic & Commercial.

Flamcomat Pump Sets, operating range. System Pressure P [bar] Boiler Output [MW] / Cooling Capacity [MW] = Boiler Output x 2.42

ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6

AQUAMATIC HY-AV 2020Plus SERIES

COLD WATER BOOSTER SETS

Pressure Independent Control Valve Applications for Building Automation, Temperature Controls, and HVAC Two-Way Chilled Water Hot Water

Each pump shall be equipped with carbon/graphite vanes. A vacuum relief valve shall be incorporated into the design of the pump.

Each pump shall be equipped with carbon/graphite vanes. A vacuum relief valve shall be incorporated into the design of the pump.

The pumps shall be Oil Free and Variable speed controlled by Pressure Transducer, PLC and inverter.

ScubaTank ScubaT Pump and tank system Combined variable speed pump and storage system

WQL/WQH/WQRC 524 to 1204

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

The pumps shall be Oil Free and Variable speed controlled by Pressure Transducer, PLC and inverter.

Technical specification

Flamco Pressurisation Equipment

Date: Project #: Engineer: Prepared By: Bid Date: 30 psi pressure relief valve 50 psi pressure relief valve 60 psi pressure relief valve

TAG3. Diesel engine - ElectropaK. Series kwm 1500 rpm. Basic technical data. Ratings. Total weight of ElectropaK

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

Section 22. Expansion Vessels, Air Separators & Air Vents

(770) Turning Parts Changers Into TROUBLESHOOTERS!

Features: Available in horizontal and vertical units

GRUNDFOS INSTRUCTIONS. Hydro MPC. Installation and operating instructions

Industrial Diesel Generator Set KD2500-F 50 Hz Fuel Consumption Optimized

COMPONENTS FOR SOLAR THERMAL SYSTEMS

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

7. Evaporative Emission Control System

M3770: SOLENOID CONTROLLED / ELECTRICALLY POSITIONED VALVE - STEP BY STEP VALVE

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

... PureLine PQ. Technical Specification. PureLine PQ (Disinfection) Models PQ PQ UV Chamber. Cabinet

Pent-A-Boost Compact Domestic Booster Sets

Industrial Diesel Generator Set KD1650-E 50 Hz - Emission Optimized EPA Tier 2 Compliant

POWERBOOST. PRO Range. Clean Water Booster Sets. powerboost.ie

Plena 24 VDC Battery Charger. Installation and User Instructions PLN-24CH10

GRUNDFOS DATA BOOKLET. Self-priming multistage pumps 50 Hz

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

Mild Steel Dosing Pots

HYDROCIAT LW. Use. Range. Water-cooled chillers. Screw compressors CIAT shell and tubes direct expansion evaporator HPS (High Power System) equipment

SITRANS P measuring instruments for pressure

VTZ variable speed Reciprocating compressors

Pressure Boosting Systems Multiple-Pump Units

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C)

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

CENTRIFUGAL CHILLER. Lubrication System Pull oil sample for spectroscopic analysis.

Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification

LK Manifold Shunt VS2

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

COMPONENTS FOR SOLAR THERMAL SYSTEMS

Industrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

LCMass Series Mass Flow Sensor

Industrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized

Boost-A-Break - Break Tank & Booster Sets

Expansion Tanks. In pressure boosting systems. Features of accumulator vessels. In closed heating and cooling circuits

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

TECHNICAL INFORMATION

The Discussion of this exercise covers the following points:

Date: Project #: Engineer: Prepared By: Bid Date:

Switchmode rectifier type RKAS with PFC

Flash Point Process Analyzer

PowerCore Dust Collectors Series CPC

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

Flow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control

Company name: GSI Created by: Xiao Ying Wong Phone: Date: 10/03/2017 Client: Client Number: Contact:

Electromotoric actuators

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

Aquavar e-abii. TECHNICAL BROCHURE BAQUAeABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS

50Hz 1500 rev/min 1 / 2 TA Luft* Prime Power. Standby Max

unrestricted; preferably with coil at bottom (auto. air bleed) 12 or 24 Volt DC from an electronic controller Deutsch plug - IP67

ECONOPLATE BV SERIES HOT WATER SERVICE PACKAGED HEAT EXCHANGERS WITH THERMAL STORES

Unicell Dust Collectors Series C10-90

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Service instructions. MAGNA Series 2000

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

Masoneilan Series

MONITORED HYDRAULIC VALVE SYSTEMS

Chiller. SWS/SWR 1602 to Water Cooled Chillers Cooling Only and Condenserless Versions Engineering Data Manual.

Large Electronically Adjustable Proportional Pressure Compensated Flow Control Engineering & Manufacturing Solutions

Electronically operated expansion valve for CO 2 Type AKVH

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

Annex A TECHNICAL SPECIFICATION FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 400V (750KVA) DIESEL

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

CYCLOPS X Purge Controller SM Version

Unvented water heaters

Expansion Vessel BS1

AGi20P 2.2 L 20 kw Perkins Powered Diesel Generator AURORA GENERATORS INCORPORATED AURORA STANDARD FEATURES STANDBY POWER RATING 20 KW, 20 KVA, 60 HZ.

Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings

Ratings TAG2A (1500 rpm)...1: TAG2A (1800 rpm)...1: TAG3A (1500 rpm)...1: TAG3A (1800 rpm)...

M Series Condensate Recovery Unit

Standby Amper VOLTAGE

Installation- and maintenance instruction ST120 S75/21

13,000 Watt Diesel Generator AGi13P E

Air-Cooled Liquid Chiller with integrated hydraulic module

Technical Data TWG2A TWG3A Series. Diesel Engine - ElectropaK rev/min. Basic technical data

Transcription:

PHP-C Pressureless Expansion System Overview Description: The PHP-C balanced pressure expansion equipment is sized according to the total system volume and the boiler or chiller load. The PHP-C vessel is 80% efficient irrespective of the static height of the system. It is the ideal solution for large installations or tall installation where standard diaphragm expansion equipment is limited. The PHP-C is an advanced product that combines a balanced pressure system with an effective pressure step de-aerator function and an inter-link to a top up pressurisation unit. The real-time LCD display shows the status of the mechanical components while monitoring the vessel contents and the system pressure. Product Features: On/Off switch, with indicator neon Constructed as type AB air gap with weir overflow, fluid category 5 Easy setup and commissioning Event logging for pump start, individual pump run hour s counter, electrical interruption and common alarm. Volt free contacts for common fault, high pressure, low pressure, pump fault, pressure transducer fault. 18 Litre break tank with type AB Air Gap Fluid Cat 5 Certifications and Standards Applied: PED 97/23/EC Sound Engineering Practice IEE - Electrical Safety Guidance EMC 2004/108/EC BS7074 Parts 1 to 3 Machine Directive 95/16/EC Electronic Components have been tested and comply with the EMC Directives EN61000-6-2: Generic Standards Immunity standard for industrial environments EN61000-6-3: Generic Standards Emission standard for residential, commercial and light industrial environment CE marked components, where applicable EN 13831/8 Closed expansion vessels WRAS approved float valve to BS1212 part 2 IP54 (BS EN60529) Rated Controller We reserve the right to change designs and technical specifications of our products. 01/10/2015 Page 1 / 6

Maximum Operating Conditions: Maximum temperature on Bladder (EN 13831/8) 70ºC Maximum temperature at (heating) outlet: 120ºC Application of Use: Commercial, Industrial Residential Selection Details Static Height of the building above the pressurisation unit (meters) Systems content (litres) if unknown provide the boiler power (kw) which can be used to estimate the systems content Flow and return temperatures Glycol content (%) if required Max working pressure Installation & Placement: The PHP-C should be installed in a frost-free and humidity free area. All vessels must be installed at the same height. The GB main vessel must be connected using the flexible hoses to give an accurate weight reading from the foot sensor. Additional BB auxiliary vessels can be connected using hard pipe. Individual isolation and drain valve for each vessel are recommended. Typical Installation Diagram (illustration purposes only) Note: Many internal components of the PHP-C pump set have been omitted We reserve the right to change designs and technical specifications of our products. 01/10/2015 Page 2 / 6

Principle of Operations: The PHP-C is designed to accurately balance system pressure to within (typically) 0.2 barg. Expansion Relief As the system fluid heats up it expands, during expansion the system pressure attempts to rise. The PHP-C control equipment senses the pressure rise and opens the connection (solenoid) valve to the expansion vessel. The expanding fluid flows into the vessel, through an orifice (to restrict flow rates) and a system pressure rise is prevented. Contraction Compensation As the system cools down, the system fluid contracts, during contraction the system pressure attempts to drop. The PHP-C control equipment senses the pressure drop and energizes the pumps. The fluid is actively from the vessel back into the system, and a system pressure drop is prevented. Safeguards Weight sensor to calculate water content of vessel at any one time. The weight sensor is calibrated in the factory with the system dry, this allows for accurate water measurement during normal operation. Pressure sensor for monitoring system pressure. Filling interlock for replenishment fluid. System fluid is lost through leaks and evaporation during air removal, fluid top up is required for maintaining the system content and integrity. This is automatically activated if the vessel volume drops below 12%. PHP-C self-diagnostics. The system holds the last 50 alarm conditions in nits memory, these can include water top up, excessive pump activation and high / low pressure alarms. Cascade setting for pumps (twin pump version only), allowing second pump to energize in addition to the first, if faster fluid replenishment is required. Pressureless Vessel and PHP-C De-aeration The water held in the vessel is at atmospheric pressure. The system effectively spills the expanded water into the PHP-C vessel. This action creates an active pressure drop between the system and the vessel. In accordance with Henry s law dissolved air can be released from water by increasing the temperature or dropping the pressure. The PHP-C system with its pressure drop design allows dissolved air to be released from the system water. This is enhanced by a cartridge of patented PALL rings in the inlet stream to the vessel. The released air is allowed to vent out of the vessel via and automatic air vent on the top. The air vent is also fitted with a non-return valve to prevent air being drawn back into the system. When the PHP-C is in passive de-aeration mode air is released during the heating and cooling cycles only. When the PHP-C is in turbo de-aeration mode the system water is continually being exchanged with the vessel water by cycling the solenoid and pumps on the skid. This turbo mode operates within the +/-0.2 bar tolerance on the system pressure setting We reserve the right to change designs and technical specifications of our products. 01/10/2015 Page 3 / 6

Technical Data: Break Tank Capacity Dimensions Connections Width Depth Height Vessel System Top-Up 18 Litres 470 320 800 1-½ 1-½ ½" Pump set Top Up Equipment (Integral) Noise Rating (dba) Pump Model Full Load Current (Amps Power Consumption (kw) Required Supply Voltage) 61 Pedrollo PQA60 2.1 0.37 230V/1/50Hz Pump set Noise Rating (dba) Pump Model Full Load Current (Amps Power Consumption (kw) Required Supply Voltage) Nominal Weight [kg] PHP 0 58 Grundfos CM1-4 6.2 1 230V/1/50Hz 105 PHP 1 58 Grundfos CM3-6 8.8 1.34 230V/1/50Hz 110 PHP 2 65 Grundfos CM5-6 10.6 2.6 415V/3/50Hz 115 PHP 3 52 Grundfos CR3-15 14.8 2.2 230V/1/50Hz 150 PHP 4 54 Grundfos CR3-17 6.4 3 415V/3/50Hz 215 PHP 5 54 Grundfos CR3-23 9 4.4 415V/3/50Hz 225 PHP 6 55 Grundfos CR3-31 12.6 6 415V/3/50Hz 240 Specification Details: We reserve the right to change designs and technical specifications of our products. 01/10/2015 Page 4 / 6

Pump Curve: Curve designated with a prefix of M show the normal characteristics of the pump module running as a single pump, curves with a prefix of D show the normal characteristics of the pump module with 2 pumps running in duty assist mode. For system requirements outside the shaded areas please contact your technical advisor. Please Note: The dimensions of the atmospheric expansion vessels are shown separately in this document. PHP-C Pump set D0-D6 FLCs stating the figures for both pumps running at the same time. FLC for Top up unit shows figure for single pump running only as far as duty/standby mode is applicable. Therefore the PHP-C unit Final Full Load Current will be sum up of the Main Pump set current draw + Top up unit current draw. We reserve the right to change designs and technical specifications of our products. 01/10/2015 Page 5 / 6

PHP M & PHP A - Atmospheric expansion vessels PHP M & A (Main & Auxiliary) vessels are manufactured to DIN 4807. The vessel includes a de-aeration cartridge containing Flamco patented Pall ring technology PHP M (Main) Vessels (Control Vessel) Type Capacity Dimensions Dry (l) Ø (mm) Height (mm) Weight (Kg) PHP A (Auxiliary) Vessels Type Capacity Dimensions Dry (l) Ø (mm) Height (mm) PHP M1.5 150 550 1350 55 PHP A1.5 150 550 1350 55 PHP M2 200 550 1530 70 PHP A2 200 550 1530 70 PHP M3 300 550 2030 90 PHP A3 300 550 2030 90 PHP M4 400 750 1535 130 PHP A4 400 750 1535 130 PHP M5 500 750 1760 151 PHP A5 500 750 1760 150 PHP M6 600 750 1955 160 PHP A6 600 750 1955 160 PHP M8 800 750 2355 195 PHP A8 800 750 2355 195 PHP M10 1000 750 2855 226 PHP A10 1000 750 2855 226 PHP M12 1200 1000 2210 290 PHP A12 1200 1000 2210 290 PHP M16 1600 1000 2710 345 PHP A16 1600 1000 2710 345 PHP M20 2000 1200 2440 430 PHP A20 2000 1200 2440 430 PHP M28 2800 1200 3040 515 PHP A28 2800 1200 3040 515 PHP M35 3500 1200 3840 625 PHP A35 3500 1200 3840 625 Weight (Kg) PHP M50 5000 1500 3570 1240 PHP A50 5000 1500 3570 1240 PHP M65 6500 1800 3500 1710 PHP A65 6500 1800 3500 1710 PHP M80 8000 1900 3650 1830 PHP A80 8000 1900 3650 1830 PHP M100 10000 2000 4050 2025 PHP A100 10000 2000 4050 2025 We reserve the right to change designs and technical specifications of our products. 01/10/2015 Page 6 / 6