KG7T (E and N Series)

Similar documents
FG7T (E and N Series)

KG7T (C and L Series)

KG7T (C and L Series)

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

FG7S (C and L Series)

VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input

FG7T (A and K Series)

TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

FG7T (A and K Series)

KG7S (A and K Series)

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE

G8MVL. Product Specifications

Product Data. that this product meets the S 95% AFUE S Two -stage operation

95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

A95-2V. 95% Gas Furnaces Two-Stage Variable Speed HEAT EXCHANGER DESIGN CONFIGURATIONS

Cooling Capacity CFM in. w.c. (125 Pa)

95G1-E. Aluminized steel primary heat exchanger with crimped non-welded construction AL 29-4C Stainless steel secondary heat exchanger

95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES

95% Gas Furnaces. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 95G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

95% Gas Furnaces A95-1E. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits CONFIGURATIONS

A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)

96G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS)

GAS FURNACES CLASSIC SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

A951E PRODUCT SPECIFICATIONS CONTROLS VENTING INSTALLATION FEATURES CONFIGURATIONS WARRANTY HEAT EXCHANGER DESIGN BURNER CABINET DESIGN

GAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES

AF90. AF90 Gas Furnace High Efficiency. Features

80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES ACHIEVER SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

F8MTL. Product Specifications

Table of Contents GF801U Series

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )

92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER CABINET DESIGN AIR DELIVERY SYSTEM CONTROLS VENTING

Rheem Classic Plus Super Quiet 80 Upflow/Horizontal Gas Furnace

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

GAS FURNACES II 80.0% 81.4% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES SILHOUETTE

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

R6GF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units Two-Stage Heat/Cool with Variable Speed Blower

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

Rheem Classic Series Two-Stage Upflow/Horizontal Gas Furnaces

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

80% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

93% Gas Furnaces Single Stage

80% Gas Furnace. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 80G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNERS

Multi-Position, Multi-Speed Gas Furnaces

XC 95m. Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace

80% A.F.U.E. DOWNFLOW GAS FURNACES

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

UPFLOW/ HORIZONTAL GAS FURNACE

G9MXE. Product Specifications

N9MPD Product Specifications

GMS9/GCS9 SERIES 93% AFUE

G9MXE. Product Specifications

Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace

TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES DESCRIPTION WARRANTY FEATURES Rev.

GAS FURNACES QUIET 80 80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

TECHNICAL GUIDE MODELS: P4HU 80 AFUE MULTI-POSITION GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger.

Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

Rheem Classic Plus Series Downflow Gas Furnace

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

Rheem Classic Series Upflow/Horizontal Gas Furnace

R6GI Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

GMSS92 / GCSS92 Single-Stage Multi-Speed Gas Furnace

G23 Bulletin # September 1998 Supersedes June 1995

Cooling Capacity CFM in. w.c. (125 Pa)

Rheem Classic Series Upflow/Horizontal Gas Furnace

A97MV PRODUCT SPECIFICATIONS 97% MODULATING VARIABLE SPEED GAS FURNACE CONTROLS VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS

Ruud Ultra Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

TECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

DM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

GMH95/GCH9 PRODUCT SPECIFICATIONS 95%/93% AFUE HEAT REPLACEMENT MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE

Rheem Value Series Downflow Gas Furnace

TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

Cooling Capacity CFM in. w.c. (125 Pa)

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL

XC 95m. Communicating Upflow/Horizontal Left Downflow/Horizontal Right Direct/Non-Direct Vent Variable Speed, Modulating Condensing Gas Furnace

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace

R8HE Series Rev A. Single-Phase and Three-Phase TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

TSTAT0101SC Recommended (sold separately)

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev.

93% Single Stage. Gas Furnace. Features and Benefits CONFIGURATIONS

A802V PRODUCT SPECIFICATIONS 2-STAGE VARIABLE SPEED GAS FURNACE VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN

W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. )

N9MSB. PS 92 Product Specifications. 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL /2/17

AMS8 / ADSS8. Single-Stage Multi-Speed Gas Furnaces 80% AFUE. Heating Input: 40, ,000 BTU/h

GMH8/GDH8. Two-Stage Convertible Multi-Speed Gas Furnaces 80% AFUE

VMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

Transcription:

TECHNICAL SPECIFICATIONS KG7T (E and N Series) Two Stage, Fixed Speed ECM, Condensing Upflow and Downflow Gas Furnaces Induced Draft - 96% AFUE Input 60,000-115,000 Btuh The high efficiency upflow gas furnace may be installed free standing in a utility room, basement, or enclosed in an alcove or closet. The extended flush jacket provides a pleasing appliance appearance. Design certified by CSA for application in Canada and the United States. FEATURES and BENEFITS Energy efficient brushless DC (ECM) motor: Can give up to 1 SEER point efficiency gain in cooling. 100% Fired and Tested: All units and each component are tested on the manufacturing line. Best Packaging in the Industry: Unique corner post design assures product will arrive to the homeowner dent free. 30 Second Blower Delay: At start-up assures a warm duct temperature at furnace start-up. Adjustable blower off settings (60, 90, 120 and 180 seconds). 30 Second Post Purge: Increases life of heat exchanger. Hot Surface Igniter: Innovative application of a silicon nitride type igniter. Utilizes proven Smartlite technology. Color Coded Wire Harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement. Flexible Category IV Venting System: May be vertically or horizontally vented using either a one-pipe or two-pipe system for maximum flexibility in installation. High Static Blowers: All models equipped with high static ECM blowers, with 16 speeds for heating & cooling. Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install. Heat Exchanger: Heavy gauge aluminized steel primary heat exchanger and stainless steel secondary heat exchanger assures a long life. 90 Second Fixed Cooling Cycle Blower-Off Delay (TDR): Increases cooling performance when matched with a Nortek Global HVAC coil. Variable Speed Blower Kit: Upgradable to full variable speed with kit. LP Convertible: Simple burner orifice and regulator spring change for ease of convertibility (as an accessory). Diagnostic Lights: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes with easy to recognize states without counting flashes. Integrated Control Boards: With connections for electronic air cleaner, humidifier, and dehumidification. Two Piece Door Design: Enhances furnace appearance and uses captured screws to prevent losing door screws. Blower Compartment: Sealed door to reduce air leakage and insulated for ultra quiet operation. Sealed Vestibule: Reduces burner and inducer sound levels. 2 Stage Inducer: Optimizes efficiency on first stage heat and reduces sound levels. Furnace Air Leakage: These furnaces comply with Energy Star cabinet air leakage requirement of less than or equal to 2%. Keep the conditioned air flowing to where it's needed.

1 2 3 4 5 6 7 8 LOCATION OF FURNACE COMPONENTS Flame Sensor Finish Flange Roll-Out Switch Burner Assembly Pressure Switches (Inducer) Igniter Main Air Limit Switch Inducer Limit Switch AIR FLOW Gas Valve Furnace Control Board Inducer Assembly Blower Door Switch Pressure Switches (Condensate) Transformer Motor Control Box Motor Choke (C & D cabinets only) Motor Control Board Blower Assembly Upflow Gas Furnace Components Blower Assembly (behind blower panel) Motor Choke (C & D cabinets only) Finish Flange Furnace Control Board Motor Control Board Blower Door Switch (behind blower panel) Vent Limit Switch AIR FLOW 1 2 3 4 5 6 7 8 Transformer Pressure Switches Inducer Assembly Gas Valve Igniter Main Air Limit Switch Flame Sensor Burner Assembly Roll-Out Switch Gas Manifold Downflow Gas Furnace Components 2

DIMENSIONS *TE 96% UpflowFurnace Cabinet Size A B C B Cabinet 17 1/2 15 7/8 16 1/8 C Cabinet 21 19 3/8 19 5/8 D Cabinet 24 1/2 22 7/8 23 1/8 NOTES: Dimensions shown in inches. TOP VIEW B FLANGES 19 23 1/2 BOTTOM VIEW C Front Brace Bottom Panel 3 1/4 Combustion Air 34 1/2 2 3/4 25 3/8 Vent pipe (Ø 3 ) 17 1/4 T-stat Electric Gas (Ø 1 5/8) 17 7/8 A T-stat Vent pipe (Ø 3 ) 24 7/8 1 Electric Gas (Ø 1 5/8) 4 Knockouts (both sides) Cond. (Ø 1 1/16) 15 28 LEFT SIDE Condensate (Ø 1 1/16) FRONT VIEW 23 RIGHT SIDE 1 1/4 *TN 96% Downflow Furnace TOP VIEW BOTTOM VIEW Cabinet Size A B C B Cabinet 17 1/2 15 7/8 16 1/8 C Cabinet 21 19 3/8 19 5/8 D Cabinet 24 1/2 22 7/8 23 1/8 NOTES: Dimensions shown in inches. Flue B FLANGES 3 19 Combustion Air 7 1/2 18 1/2 C Front Brace 34 1/2 28 25 1/4 22 1/4 25 1/2 Vent pipe (Ø 3 ) Cond. (Ø 1 1/16) 10 1/4 Electric Gas (Ø 1 5/8) 17 1/4 A T-stat Electric Gas (Ø 1 5/8) 17 1/4 22 1/4 25 Vent pipe (Ø 3 ) 25 3/8 Cond. (Ø 1 1/16) 17 7/16 29 1/2 LEFT SIDE FRONT VIEW RIGHT SIDE 3

MODEL IDENTIFICATION CODE KG 7 T E 080 D 35 B 1 Gas Furnace Design Series Cabinet Width B = 17.50 C = 21.00 D = 24.50 S = Single Stage T = Two Stage A = 80% Upflow/Horizontal C = 92.1% / 95.1% Upflow/Horizontal E = 96% Upflow K = 80% Downflow L = 92.1% / 95.1% Downflow N = 96% Downflow Input Heating Capacity 060 = 60,000 080 = 80,000 100 = 100,000 115 = 115,000 C = Standard D = 90+% AFUE Low NOx Cooling Airflow 23 = 2-3 Tons 24 = 2-4 Tons 35 = 3-5 Tons 45 = 4-5 Tons V = VSB SPECIFICATIONS KG7TE/TN MODEL NUMBERS: -060D-24B1-080D-35C1-100D-35C1-115D-45D1 Input - Btuh (a) 60,000 / 39,000 80,000 / 52,000 100,000 / 65,000 115,000 / 74,750 Heating Capacity - Btuh 57,600 / 37,440 76,800 / 49,920 96,000 / 62,400 110,400 / 71,760 AFUE 96 96 96 96 Motor FLA 6.2 8.7 8.7 11.70 Rated Ext. SP - In. W.C. 0.5 0.5 0.5 0.5 Temperature Rise Range - ºF 30-60 35-65 35-65 40-70 Shipping Weights 125lbs 135lbs 145lbs 160lbs Note: All models are 115V, 60 Hz. Gas Connections are 1/2" N.P.T. AFUE = Annual Fuel Utilization Efficiency (a) Ratings to 2,000 ft. Over 2,000 ft. reduce 4% for each 1,000 ft. above sea level. 4

BLOWER PERFORMANCE - KG7TE/TN KG7TE/TN - 96% AFUE, Two Stage Gas Furnace Model Number & Heating Input (Btuh) Motor Switch Settings (0 = OFF, 1 = ON) External Static Pressure (in.w.c.) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 1/5 2/6 3/7 4/8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise 0 0 0 0 1 0 0 0 0 1 0 0 1 1 0 0 725 0 0 1 0 810 1 0 1 0 940 57 890 60 845 795 750 700 *TE/*TN - 060D - 24B1 (60,000 BTUH) Temperature Rise 30 F to 60 F 0 1 1 0 990 54 945 56 905 59 860 820 775 735 690 1 1 1 0 1,055 51 1,015 53 970 55 930 57 890 60 845 805 760 0 0 0 1 1,135 47 1,095 49 1,055 51 1,010 53 960 56 930 57 890 60 850 1 0 0 1 1,185 45 1,145 47 1,105 48 1,065 50 1,030 52 990 54 950 56 910 59 0 1 0 1 1,250 43 1,210 44 1,170 46 1,135 47 1,095 49 1,055 51 1,020 52 980 54 1 1 0 1 1,290 41 1,255 42 1,220 44 1,180 45 1,145 47 1,110 48 1,075 50 1,040 51 0 0 1 1 1,315 41 1,275 42 1,240 43 1,200 44 1,160 46 1,120 48 1,085 49 1,045 51 1 0 1 1 1,350 40 1,315 41 1,280 42 1,245 43 1,205 44 1,170 46 1,135 47 1,100 48 0 1 1 1 1,390 38 1,350 40 1,315 41 1,275 42 1,240 43 1,200 44 1,160 46 1,125 47 1 1 1 1 1,420 38 1,380 39 1,345 40 1,310 41 1,270 42 1,235 43 1,200 44 1,160 46 0 0 0 0 1,125 63 1,040 960 880 795 1 0 0 0 1,205 59 1,120 63 1,040 960 875 795 0 1 0 0 1,305 54 1,225 58 1,150 62 1,070 995 915 840 1 1 0 0 1,430 50 1,350 53 1,270 56 1,190 60 1,110 63 1,030 950 865 0 0 1 0 1,525 47 1,450 49 1,375 52 1,300 55 1,225 57 1,150 62 1,075 66 1,000 1 0 1 0 1,620 44 1,540 46 1,465 49 1,390 51 1,315 54 1,240 57 1,165 61 1,090 65 *TE/*TN - 80D - 35C1 (80,000 BTUH) Temperature Rise 35 F to 65 F 0 1 1 0 1,695 42 1,620 44 1,545 46 1,465 49 1,390 51 1,315 54 1,235 58 1,160 61 1 1 1 0 1,770 40 1,700 42 1,630 44 1,555 46 1,485 47 1,410 50 1,340 53 1,265 56 0 0 0 1 1,875 38 1,805 39 1,730 41 1,655 43 1,580 45 1,510 47 1,435 50 1,340 53 1 0 0 1 1,905 37 1,840 39 1,775 40 1,710 42 1,640 43 1,575 45 1,510 47 1,445 49 0 1 0 1 1,980 36 1,910 37 1,845 39 1,780 40 1,715 41 1,650 43 1,580 45 1,515 47 1 1 0 1 2,025 35 1,960 36 1,895 38 1,830 39 1,765 40 1,700 42 1,635 43 1,570 45 0 0 1 1 2,085 2,025 35 1,960 36 1,900 37 1,840 38 1,775 40 1,715 41 1,655 43 1 0 1 1 2,135 2,070 2,010 35 1,945 37 1,880 37 1,815 39 1,750 41 1,685 42 0 1 1 1 2,200 2,145 2,090 2,035 35 1,980 36 1,925 37 1,870 38 1,820 39 1 1 1 1 2,280 2,225 2,170 2,115 2,065 2,010 1,955 36 1,900 37 1. Motor Switch Settings are for heating speeds using HEAT switches 1, 2, 3, & 4 and cooling speeds using COOL switches 5, 6, 7, & 8. 2. Two openings are required for airflows above 1,600 CFM if the filter(s) is (are) adjacent to the furnace. 3. Data is shown without filter. 4. Temperature rises in the table are approximate. Actual temperature rises may vary 5. Cells shaded in gray indicate a temperature rise outside of the recommended range. 6 When in low stage, the circulating airflow is 70% of the tables high value (2-stage furnaces only). 5

BLOWER PERFORMANCE - KG7TE/TN Continued KG7TE/TN - 96% AFUE, Two Stage Gas Furnace Model Number & Heating Input (Btuh) Motor Switch Settings (0 = OFF, 1 = ON) External Static Pressure (in.w.c.) 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 1/5 2/6 3/7 4/8 CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise CFM Rise 0 0 0 0 1,125 1,040 1 0 0 0 1,205 1,120 1,040 0 1 0 0 1,305 1,225 1,150 1,070 995 1 1 0 0 1,430 62 1,350 66 1,270 1,190 1,110 1,030 0 0 1 0 1,525 58 1,450 61 1,375 65 1,300 1,225 1,150 1,075 1,000 1 0 1 0 1,620 55 1,540 58 1,465 61 1,390 64 1,315 1,240 1,165 1,090 *TE/*TN - 100D - 35C1 (100,000 BTUH) Temperature Rise 35 F to 65 F 0 1 1 0 1,695 52 1,620 55 1,545 58 1,465 61 1,390 64 1,315 1,235 1,160 1 1 1 0 1,770 50 1,700 52 1,630 55 1,555 57 1,485 60 1,410 63 1,340 1,265 0 0 0 1 1,875 47 1,805 49 1,730 51 1,655 54 1,580 56 1,510 59 1,435 62 1,340 1 0 0 1 1,905 47 1,840 48 1,775 50 1,710 52 1,640 54 1,575 56 1,510 59 1,445 62 0 1 0 1 1,980 45 1,910 47 1,845 48 1,780 50 1,715 52 1,650 54 1,580 56 1,515 59 1 1 0 1 2,025 44 1,960 45 1,895 47 1,830 49 1,765 50 1,700 52 1,635 54 1,570 57 0 0 1 1 2,085 43 2,025 44 1,960 45 1,900 47 1,840 48 1,775 50 1,715 52 1,655 54 1 0 1 1 2,135 42 2,070 43 2,010 44 1,945 46 1,880 47 1,815 49 1,750 51 1,685 53 0 1 1 1 2,200 40 2,145 41 2,090 43 2,035 44 1,980 45 1,925 46 1,870 48 1,820 49 1 1 1 1 2,280 39 2,225 40 2,170 41 2,115 42 2,065 43 2,010 44 1,955 45 1,900 47 0 0 0 0 1,395 1,350 1,305 1,260 1,210 1,165 1,120 1 0 0 0 1,465 1,420 1,375 1,330 1,290 1,245 1,200 1,155 0 1 0 0 1,555 66 1,510 68 1,470 1,425 1,380 1,340 1,295 1,250 1 1 0 0 1,625 63 1,585 64 1,540 66 1,500 68 1,460 1,415 1,375 1,335 0 0 1 0 1,690 60 1,650 62 1,610 63 1,570 65 1,530 67 1,485 1,445 1,405 1 0 1 0 1,760 58 1,715 60 1,670 61 1,625 63 1,575 65 1,530 67 1,485 1,440 *TE/*TN - 115D - 45D1 (115,000 BTUH) Temperature Rise 40 F to 70 F 0 1 1 0 1,835 56 1,790 57 1,745 59 1,695 60 1,650 62 1,605 64 1,555 66 1,510 68 1 1 1 0 1,885 54 1,840 56 1,790 57 1,745 59 1,700 60 1,655 62 1,610 63 1,565 65 0 0 0 1 1,945 53 1,900 54 1,850 55 1,805 57 1,760 58 1,710 60 1,665 61 1,620 63 1 0 0 1 1,950 52 1,905 54 1,860 55 1,820 56 1,775 58 1,735 59 1,690 60 1,650 62 0 1 0 1 2,075 49 2,030 50 1,990 51 1,945 53 1,900 54 1,855 55 1,810 56 1,770 58 1 1 0 1 2,125 48 2,085 49 2,040 50 2,000 51 1,955 52 1,910 54 1,870 55 1,825 56 0 0 1 1 2,170 47 2,130 48 2,090 49 2,045 50 2,005 51 1,965 52 1,925 53 1,880 54 1 0 1 1 2,215 46 2,180 47 2,140 48 2,105 49 2,070 49 2,035 50 2,000 51 1,965 52 0 1 1 1 2,225 46 2,165 47 2,100 49 2,040 50 1 1 1 1 2,170 47 2,120 48 2,065 50 1. Motor Switch Settings are for heating speeds using HEAT switches 1, 2, 3, & 4 and cooling speeds using COOL switches 5, 6, 7, & 8. 2. Two openings are required for airflows above 1,600 CFM if the filter(s) is (are) adjacent to the furnace. 3. Data is shown without filter. 4. Temperature rises in the table are approximate. Actual temperature rises may vary 5. Cells shaded in gray indicate a temperature rise outside of the recommended range. 6 When in low stage, the circulating airflow is 70% of the tables high value (2-stage furnaces only). 6

VENTING All models are approved for vertical non direct (1 pipe) and direct (2 pipe) venting applications. See Vent Table below for specified sizes and allowable lengths. FURNACE MODELS (BTU) FURNACE INSTALLATION SINGLE PIPE LENGTH (FT.) with 1 long radius elbow** DIRECT VENT, DUAL PIPE LENGTH (ft.) WITH 1 long radius elbow on each pipe** OUTLET OUTLET INLET/OUTLET INLET/OUTLET 2 Diameter 3 Diameter 2 Diameter 3 Diameter 60,000 Upflow 90 90 60 90 Downflow 30 90 30 90 80,000 Upflow 40 90 40 90 Downflow 30 90 30 90 100,000 Upflow 30 90 30 90 Downflow 30 90 25 90 115,000 Upflow N/A 90 N/A 90 Downflow N/A 90 N/A 90 *NOTES: 1. Subtract 2.5 ft. for each additional 2 inch long radius elbow, 5 ft. for each additional 2 inch short radius elbow, 3.5 ft. for each additional 3 inch long radius elbow, and 7 ft. for each additional 3 inch short radius elbow. Subtract 5ft for each 2 tee and 8ft for each 3 tee. 2. Two 45 degree elbows are equivalent to one 90 degree elbow. 3. This table applies for elevations from sea level to 2,000 ft. For higher elevations, decrease pipe lengths by 8% per 1,000 ft of altitude. 7

ACCESSORIES KG7TE/TN KITS Description SKU Fixed Speed to Variable Speed 904880 2" Concentric Vent Kit 904177 3" Concentric Vent Kit 904176 2" Concentric Vent Kit (Canadian Approved) 904952 3" Concentric Vent Kit (Canadian Approved) 904953 "A" Cabinet Downflow Sub Base Kit 902974 "B", "C", "D" Cabinet Downflow Sub Base Kit 904911 2" Side Wall Vent Kit 904617 3" Side Wall Vent Kit 904347 U.S. LP Conversion Kit (0 to 10,000 ft.) 905028 Canada LP Conversion Kit (0 to 4,500 ft.) 905029 Bottom Return Filter 20 per Box, "B" Cabinet 904916 Bottom Return Filter 20 per Box, "D" Cabinet 904918 Side Return Filter Kit 541036 Neutralizer Kit 902377 GENERAL TERMS OF LIMITED WARRANTY Nortek Global HVAC, LLC will furnish a replacement for any part of this product which fails in normal use and service within the terms and conditions of the warranty. For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the Nortek Global HVAC, LLC warranty department for a copy. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Printed in U.S.A (06/2017) 731E-0617 (Replaces 731E-0117)