VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 172,9/138,3 190,6/152,5 265,44 400/ ,8 172,9/138,3 190,6/152,5 275,4

Similar documents
VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 85,0/68,0 93,5/74,8 130,23 400/ ,8 85,0/68,0 93,5/74,8 135,12

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 450,0/360,0 495,0/396,0 689,46 400/ ,8 450,0/360,0 495,0/396,0 715,32

Code: VOLVO TAD 734 GE MECC-ALTE ECO 38-1LN. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 250,0/200,0 275,0/220,0 397,4

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 41,8/33,4 46,0/36,8 64,02 400/ ,8 41,8/33,4 46,0/36,8 66,42

ENGINE MAKE MODEL CONTINUOUS POWER PERKINS 2206A-E15TAG2 STAND-BY POWER

VOLTAGE HZ PHASE COS PRP KVA/KW LTP KVA/KW AMPERAGE A

Code: FPT F32AM1A MECC-ALTE ECP 28-VL / 4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 30,0/24,0 32,5/26,0 46,97 ESPAÑA

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE (LTP) 400/ ,8 62,3/49,9 68,6/54,9 99,17

TECHNICAL SPECIFICATIONS

Code: KOHLER KDW 1404 ZANARDI ATO 28-1VS/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 10,0/8,0 11,0/8,8 15,9

Code: DEUTZ BF4M 1013 FC MECC-ALTE ECP 34-1L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP)

Code: VOLVO TAD 731 GE MECC-ALTE ECP 34-2L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 150,0/120,0 165,0/132,0 238,44

Code: KOHLER KDI1903M MECC-ALTE ECP 28-M/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 18,9/15,2 20,8/16,6 30,07

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 102,6/82,1 113,0/90,4 157,32 400/ ,8 102,6/82,1 113,0/90,4 163,22

1 / Genset general description

DGP-25 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

1 / Genset general description

DGL 6 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

1 / Genset general description

HFW-85 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Standard soundproofing Powered by FPT_IVECO

Subsidiaries: PORTUGAL POLAND GERMANY UK SINGAPORE UAE PANAMA DOMINICAN REPUBLIC ARGENTINA ANGOLA SOUTH AFRICA

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Power kva 9,3 10 Power kw 9,3 10 Rated Speed r.p.m Standard Voltage V 240 Rated at power factor Cos Phi 1

Generating Rates WATER-COOLED THREE PHASE 50 HZ DIESEL. ADVANCED with quality certification ISO 9001

GSW22P. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

GSL30D. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 0.8 Phase and connection 3

Generating Rates SERVICE PRP STANDBY. HEAVY RANGE Container Powered by MTU

Standby Amper VOLTAGE

GE.VO.360/325.SS+0_all

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

GMS-015Y. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

HYW-20 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Open Skid Powered by YANMAR

Standby Amper VOLTAGE

GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Open Skid Powered by SCANIA

JCB Diesel Generator Technical Specifications G45QX. Electrical. Prime

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

Standby Amper VOLTAGE

JCB Diesel Generator Technical Specifications G331QX. Electrical. Prime

P 602. Voltage kva kw kva kw Amp 400/230 93,00 74,40 85,00 68,00 123,00 OTHER ACCESSORIES

Technical specification

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by YANMAR

JCB Diesel Generator Technical Specifications G31RX. Electrical. Prime

HFW-350 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

GE.PK.022/020.SS+0_all

Generating Rates. INDUSTRIAL RANGE Soundproof Powered by DOOSAN

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by DOOSAN

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Power kva 11,5 12,4 Power kw 9,2 9,9 Rated Speed r.p.m Standard Voltage V 230/115 Rated at power factor Cos Phi 0,8

HDW-200 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by DOOSAN

PRAMAC GBW 45. Main features. GBW Series. Item code: SB450TPAY kw. Standby power LTP. 34 kw. Rated prime power (PRP)

Power kva 14,3 15,6 Power kw 11,4 12,5 Rated Speed r.p.m Standard Voltage V 230/115 Rated at power factor Cos Phi 0,8

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by YANMAR

Alpha SERIES LWA 10(A)*, LWA 15(A), LWA 20(A), LWA 27(A) 50 Hz; 1500 r/min; power outputs: kva 60 Hz; 1800 r/min; power outputs:

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by SCANIA

HFW-350 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

GSW80P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW150P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

Large autonomy Safety Ease of handling Silent. 18,0/14,4 20,0/16,0 Yanmar 4TNE88PG. 18,5/14,8 19,6/15,7 Deutz F3M 1011 F

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

57 KW / 71 KVA POWERED by

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

TPD2250H6.3 TECHNICAL DATA

GBW22Y. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

Generating Rates SERVICE PRP STANDBY. HR RANGE Soundproofed rental Powered by YANMAR

16 KW / 20 KVA POWERED by

WPS350/S EP Series. Features:

GCW22P (ALT. LSM) Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

60 KW / 75 KVA POWERED by

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ , , , , ,00

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

SIVASA Doosan Series. SD250 Technical Data

GSW35Y. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

GBW22P. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

70 KW / 90 KVA POWERED by

GSW500DO. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

WPS20/S EP Series. Features:

WPS100/S EP Series. Features:

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET MPS180S-1E / MPS180-1E

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Model: HHY 20 C T INDUSTRIAL RANGE Soundproof Powered by YANMAR

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw Amp 400/ ,00 880, ,00 824, ,00

Manufacture facilities: SPAIN FRANCE INDIA CHINA USA Subsidiaries: ITALY PORTUGAL POLAND GERMANY I SINGAPORE UAE MEXICO PANAMÁ I ARGENTINA

LWALR LIQUID COOLED LONG RUNNING GENSETS

30 KW / 40 KVA POWERED by

350 KW / 438 KVA. POWERED by TP-V350-T1-60. kva 438 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 400 Prime Power Factor 0.

Generating Rates SERVICE PRP STANDBY. HEAVY RANGE Container Powered by MITSUBISHI

Transcription:

TECHNICAL SPECIFICATIONS Model: II-190 Stand-by automatic gen set. Image for guidance purposes. (400 / 230 V) ENGINE MAKE FPT MODEL NEF N67 TM4 CONTINUOUS POWER: (PRP Prime Power norma ISO 8528-1) 170 kva ALTERNATOR MODEL MECC-ALTE ECO 38-1SN STAND-BY POWER: (LTP Limited Time Power norma ISO 8528-1) 190 kva Amperes in the different voltages: VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/240 50 3 0,8 172,9/138,3 190,6/152,5 265,44 400/230 50 3 0,8 172,9/138,3 190,6/152,5 275,4 380/220 50 3 0,8 172,9/138,3 190,6/152,5 289,89 240/139 50 3 0,8 172,9/138,3 190,6/152,5 459 230/133 50 3 0,8 172,9/138,3 190,6/152,5 478,95 220/127 50 3 0,8 172,9/138,3 190,6/152,5 500,72

ENGINE CHARACTERISTICS MAKE FPT GENERAL DATA Power PRP (kwm) Power LTP (kwm) No. cylinders Cylinder capacity (L) Diameter per stroke (mm) Compression ratio Cooling system Injection Suction Series regulator Fly wheel coupling MODEL NEF N67 TM4 149.70 165.00 6 6.70 104 x 132 17.50 LIQUID DIRECT TURBO MECHANICAL 3-11,5" Lubrication system Oil capacity (L) Oil consumption (%) Min. alarm oil pressure (bar) 17.20 0.10 - Ventilation system Air cooling flow (m3/h) Combustion air flow (m3/h) Max. back pressure for fan (mbar) 13680 586.00 - Exhaust system Exhaust gas flow (m3/h) Exhaust back pressure (mbar) Temp. exhaust gases (ºC)) 741 50 497 Electrical system VDC (V) Battery (Ah) Engine start-up (kw) 12 100 3 Teléfono: +34 968 380 Planet 129 Trading Phone: and Transportation +34 968 380 879 W L L Street No:4 / Gate Fax: No: +34 117 968 380 / Building 504 No:235 / Fax: Industrial +34 968 Area 380 400 / PO Box: 8359 Doha / Qatar Tel: 974 E-mail: 4498 sales@inmesol.com 7849

ALTERNATOR CHARACTERISTICS MODEL MECC-ALTE ECO 38-1SN (400 / 230 V) GENERAL DATA Power PRP (kva) Power LTP (kva) Efficiency Alt. 3/4 % Efficiency Alt. 4/4 % No. Poles Voltage regulator No. wires Insulation Xd (%) X d (%) X Degree of protection 180 198.00 92.60 92.40 4 DSR 12 H 197 9.70 5.50 IP21 GENERATOR SET CONSUMPTION % POWER USED LITRES/HOUR 50% 18.00 75% 29.40 100% 36.60 DIMENSIONS, CAPACITIES, APPROXIMATE WEIGHT AND NOISE DIMENSIONS (MM) LENGTH WIDTH HEIGHT 2950 1100 1760 FUEL TANK (LITRES) WEIGHT (KG) 220.00 - NOISE LEVEL (db (A)) -

INMESOL GENERATOR SET GENERAL DESCRIPTION The INMESOL generator set is an electrical energy generating machine which is used in places where there is no mains supply or when there is a MAINS failure. The mobile elements, distribution belt, fan, etc., and those parts which reach high temperatures during operation, exhaust manifold, etc, include their corresponding protections, in compliance with the requirements of the Machinery Directive 2006/42. REGULATIONS The machine holds the CE marking, and the corresponding Declaration of Conformity is issued with each of them, in which it specifies that the machine complies with R.D 842/2002 Low Voltage Regulations and with the European Directives: 2006/42 on Safety in Machinery. 2006/95/CE on Electrical Safety. 2004/108/CE on Electromagnetic Compatibility. 2005/88/CE on NOISE EMISSIONS by equipment for outdoor use (for SOUNDPROOF GENERATOR SETS).

SB STAND-BY RANGE / SCOPE OF SUPPLY Engine/alternator monobloc directly conected and installed via silent blocks on a frame made from high tensile electro welded steel profiles that are treated with degreasing liquids and aplicated with a phosphate coat and epoxi paint. Canopy of steel sheet sound proofed with fireproof rockwool, and treated with degreasing liquids and aplicated with a phosphate coat and epoxi paint. Fuel tank integrated in the chassis provided with fuel level jauge and fuel lines to the engine. Engine with mechanical engine driven pusher fan. Industrial silencer with -15 db(a) noise reduction and exhaust outlet tube. Residencial silencer with -35 db(a) noise reduction with exhaust tube and protection cap. 4 Pole termal and magnetic circuit breaker. Battery charge alternator. Starter battery complete with cables to the engine and pole protection. Installation prepared for earthing spike (spike not included). Security protection for blets and moving parts as well as on electrical component. External emergency stop push button. Manual engine oil extraction pump. Self excited and auto regulated alternator. Integrated lifting hook for single point lifting with crane, gensets up to 450 kva (Except in swing-out cover model) 4 Lifting points for gen sets from 450 kva and bigger. Preparate for extended fuel tank, fully bomded for leakage protection. Base frame preparated for trailer kit Standard electronic speed governor on engines from 220 kva and up. Electric control cubicle with digital control module, automatic mains failure, manual start or remote start on signal. Battery charger for gen set with 12VCC battery (2A). Battery charger for gen set with 24VCC battery (5A). Electric engine coolant preheating on gen sets with automatic mains failure controller. Horizontal outlet for hot air Street No:4 / Gate Fax: No: +34 117968 / Building 380 504 No:235 / Industrial Fax: +34 Area 968 / PO 380 Box: 400 8359

DSE 6020 MKII AUTOMATIC CONTROL PANEL DSE 6020 MKII AUTOMATIC CONTROL PANEL PROTECTION, DISTRIBUTION AND AUTOMATIC CONTROL panel which starts the generator set when it detects a mains failure and stops it when the mains is restored with the control unit DSE 6020 MKII. It also starts and stops the group manually via a pushbutton or remote start-up by contact It has the following: Imágenes orientativas. 1 EMERGENCY STOP PUSHBUTTON 2 PROTECTIONS: Magnetothermal switch (preheating resist.) 2P (16 A) Protection fuses for control module 3 BATTERY CHARGER

DSE 6020 MKII AUTOMATIC CONTROL PANEL 4 DSE 6020 MKII PROTECCION CONTROL MODULE. It has a digital LCD screen, which provides easy reading of the information regarding the ENGINE, ALTERNATOR, MAINS and CHARGING. READINGS that can be made:: ENGINE: Coolant temperature Oil pressure Turning speed (rpm) ALTERNATOR AND CHARGE: Fuel level Battery voltage Battery alternator voltage. Operating hours Number of start-ups Voltages between phases and between phases and neutral. Intensities Frequency Active Power (kw) MAINS: Frequency Voltages between phases and neutral (L1-N, L2-N, L3-N). Voltages between phases and (L1-L2, L2-L3, L1-L3). Reactive Power (kvar) Apparent Power (kva) Cos phi Active energy meter (kw-h) Reactive Power (kvar) Apparent Power (kva) Cos phi CONTROL of the set: STARTS and STOPS the set AUTOMATICALLY when mains failure is detected and when it is restored, respectively. It can also operate MANUALLY a REMOTE START Breaker control via fascia buttons Protection of the engine and alternator, with the ALARMS activated: ENGINE: Low oil pressure High coolant temperature Low and High battery Voltage. Failure of the alternator to charge batteries Low fuel level Engine maintenance alarms for fuel filter, air filter and oil filter

DSE 6020 MKII AUTOMATIC CONTROL PANEL ALTERNATOR: Low and High Voltage Low and High Frequency Overload due to Intensity (A) Power Overload (KW) MAINS: Low and High Voltage Low and High Frequency OTHER CHARACTERISTICS: The real-time clock provides an exact record of events. Extensive number of configurable inputs and outputs. Configurable alarms and timers. USB connectivity Fully configurable via software and PC. Communication via USB cable for remote control Programmable clock with multiple maintenance events which can be configured for optimal motor functioning. Weekly and/or monthly programming for up to 8 startups and shutdowns per week. ALTERNATIVE CONFIGURATIONS, which open up the working possibilities 5 DISTRIBUTION: Direct output of the magnetothermal switch. 6 OPTIONAL: 4-Pole Switchboard insalled next to the controler in the same metal cabinet. 4-Pole Switchboard in metal cabinet independent from the Automatic Panel

DSE 6020 MKII AUTOMATIC CONTROL PANEL The following table shows the different amperages of the magnetothermal switches and the switchboards according to the set s power - Three-phase generators (single phase by request): SET S POWER CONT. POW. CONTINUOUS POWER MAGNETOTHERMAL PROTECTION IV POLES (A) SWITCHBOARD IV POLES (A) 10 kva 16 25 15 kva 25 25 20 kva 32 30 30 kva 50 45 40 kva 63 60 50 kva 80 100 60 kva 100 100 75 kva 125 125 80 kva 125 125 100 kva 160 160 125 kva 250 260 150 kva 250 260 160 kva 250 260 170 kva 250 260 200 kva 400 400