Analogue Instruments. DIN Panel Meters. Benefits Low cost Local indication Ease of installation Minimal training Low maintenance Reasonable accuracy

Similar documents
DIN Panel Meters Long Scale

240 Series DIN Panel Meters

ANSI Switchboard Meters

Jewell 212, 312 and 412 VISTA Series Analog Panel Meter Series BEST IN CLASS

212, 312 & 412 Vista Series Analog Panel Meter

AC Wattmeters and VArmeters

PLATINUM SERIES SWITCHBOARD METERS

212, 312 & 412 Vista Series Analog Panel Meter

Smart Look Series Meter

M Series 140.D Data Sheet. Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial RW 96 RP 96

M Series 010.D Data Sheet. Analog Meters with Moving-Coil Movement, 90 Dial PSQ 48 PQ 72 RS PQ 96 RS PQ 144 RS

Technical Data Sheet Sigma Series DS Meter

Crompton AC Overload Ammeters. Crompton 4-IN-1 Panel Meters NEW. DIN Panel Meters. Fiesta 3 1 /2" Panel Meter SPECIFICATIONS/ORDERING INFORMATION

POWER FACTOR METERS LF 72 / LF 96 ANALOGUE METERS

SIGMA SERIES DE METER

Technical Data Sheet Sigma Series DG Meter

Century Style Analog Panel Meters

Wide-Vue Analog Panel Meters

Data Sheet. Analogue Meters With Moving - Iron Movement - DE DE 48 DE 72 DE 96 DE 144. Analogue Meters with. Moving - Iron Movement

Technical Data Sheet Sigma Series DE Meter

Wide-Vue Analog Panel Meters

LED Digital Analog Combination

YOKOGAWA Supplies A Complete Line of Precise Panel Meters... RoHS compliant

Price List Effective from :

Panel Meters and Accessories Digital Panel Meter

Standard Program Technical Description

Portable Instruments. Bulletin 2000-E

INSTALLATION INSTRUCTIONS

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay

SECTION INDEX. Whether the need is for a simple voltmeter or a complex monitoring system, look to Blue Sea Systems for a solution.

Wind display type WSDI-2 DATA SHEET

PRODUCT / TEST MANUAL 2C58K2 INSTANTANEOUS OVERCURRENT

Meters Product Selection Guide

B CW POWER RELAY

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

NOT RECOMMENDED FOR NEW DESIGNS. Wind display type WSDI-2 DATA SHEET. Watertight. Displays

www. ElectricalPartManuals. com INS T R U c.t I 0 N S Westinghouse OPER.ATION MAINTENANCE INSTALLATION SWITCHBOARD INSTRUMENTS SIX-INCH CLASSIFICATION

Square Shape Instrument - PK Series

ntents Meter Product Line-up Usage Precautions View Scale Forms and Divisions Standard Specifications Key to Meters Numbering System DC Ammeters

DIN Rail Mounting Bracket

MOVING-COIL METERS MA16, MB16, MA17, MA17P, MA19, MA19P, MA12, MA12P TYPES

COM Overcurrent Relay

KD LV Motor Protection Relay

Model 8 Mk7 AVOMETER USER GUIDE GUIDE DE L UTILISATEUR BEDIENUNGSANLEITUNG GUÍA DEL USUARIO

EKT112 Principles of Measurement and Instrumentation. Power Measurement

OPERATING INSTRUCTION

To study the constructional features of ammeter, voltmeter, wattmeter and energymeter.

EM DC Multi-Function DC Energy Meter

University of Houston Master Construction Specifications Insert Project Name

International Instruments Edgewise Panel Meters

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

CT current transformers Ip/5 A ratio

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

3.0 CHARACTERISTICS E Type CO-4 Step-Time Overcurrent Relay

MODEL 422 Submersible Pump Controller

MaxPak Plus Analog DC V S Drive

INTER PLANT STANDARD STEEL INDUSTRY SPECIFICATION FOR STATIC EXCITATION CONVERTORS FOR SYNCHRONOUS MOTORS (FIRST REVISION)

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Voltmeter and Ammeter Design

Figure 1. Type CWP-1 Ground Relay (Front View) Figure 2. Type CWP-1 Ground Relay (Rear View) E

Relcotech Transformer Manufacturer Sdn. Bhd. Flood Light. Description. Model: S MH70W S MH150W. Specification: Ingress Protection: IP65

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

2.0 CONSTRUCTION AND OPERATION 3.0 CHARACTERISTICS K. CO (HI-LO) Overcurrent Relay

75a. Hoyt VU Meters. Industry Standard for Volume Level Measurements Sizes from 1.5" to 4.5" Choice of Styles & Mounting Made in U.S.A.

ANSI Switchboard Meters

BM kv Digital Insulation Tester USER MANUAL

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

ELECTRICAL ENGINEERING DEPARTMENT LIST OF EQUIPMENT IN EEM LAB

Horizontal Circuit Switchers

A - Add New Information C - Change Existing Information D - Delete Information. Page 7. Delete the fourth paragraph beginning CAUTION

Horizontal Circuit Switchers

Hillstone PowerBank HPB54 Series ( 400A 700A )

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Positions: L1-L2, L1-L3, L2-L3, L1-N, L2-N, L3-N Positions: L1-L2, L1-L3, L2-L3, OFF. Measuring range. Type 144 svs Cat. No

INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Transforming Energy.. For Advanced Technology

ALR output Powerfull PROGRAMMABLE POWER SUPPLY 640 WATTS 0-32V 0-20A POWERFUL. Specifications

2. Analog measurement of Electrical Quantities

Powerframes - Power Electronics

AF series contactors (9 2650)

PPT 802, Proximity Probe Transducer System

Do not risk your safety!

PRODUCT/TEST MANUAL 2C58K37 INSTANTANEOUS OVERCURRENT RELAY

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

SWITCHGEAR. 4G cam switches

HOKKIM. Control & Protection Relays. giving you control. Utilization: Power Factor Regulator : 14-STEP CYCLIC POWER FACTOR REGULATOR.

Power Controller. (see note 1) 10 sec

See «Overview of types»

Power System Measurements. Made in U.S.A. Power Series Plus. Digital Switchboard Meters.

BHARAT ALUMINIUM COMPANY LTD. SPECIFICATIONS FOR SYNCHRONOUS GENERATOR GENERAL Make : Jinan Power Equipment Factory Type : WX2

ABB. Type CRQ Directional Negative Sequence Relay for Ground Protection B 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION CAUTION

Chapter 9 Basic meters

Powerframes - Power Electronics

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis

Electrical Power Electric power electrical electric power Electric power electric electric

Bulletin 825 SMM Smart Motor Manager

L. Photo. Figure 2: Types CA-16 Relay (rear view) Photo. Figure 1: Types CA-16 Relay (front view)

Transcription:

Analogue Instruments High quality analogue instruments designed to measure an extensive range of electrical and electronic parameters. This comprehensive range offers DIN instruments, ANSI switchboard meters, panel indicators, sealed and ruggedised instruments, and complementary selector switches for line-to-line and line-to-neutral readings. Instruments are precision engineered and robust in design, ensuring accurate measurement and display in the most demanding of environments. All instruments are available in a range of styles, sizes and specifications to meet the exacting needs of your industry. Contents Page DIN Panel Meters 2 21 An extensive range of 48, 72, 96 and 144mm DIN style panel meters. Short-scale ammeters, voltmeters and frequency meters incorporate slide-in dials and terminal covers. Long-scale meters are also available. Meters for power or energy contain in-built transducers and can be customised to suit many different system configurations and ranges. Instrument DIN Panel Meters Selector - Short Switches Scale: Specs and Page 2-3 22 DIN Panel AC Ammeters Meters mounted Short and selector Voltmeters Scale switches Specs/ PAGE offering 4 a 7-position PAGE 2-3 voltmeter Moving Frequency Moving switch Iron and AC Iron Iron Meters Ammeters a Ac 4-position Ac Ammeters PAGE and ammeter 4 Voltmeters and and Voltmeters switch PAGE for reading 4 line-to-line or Page 4 Frequency Maximum line-to-neutral voltage and phase current. Frequency Meters Demanctified Meters PAGE 4 AC Ammeters and Voltmeters PAGE 6 Page 4 Maximum Process Saxon Demand Indicators Series Indicators PAGE 7 Panel Indicators PAGE 5 23 24 Combined Moving Maximum A range AC Iron of Ammeter AC Demand Ammeters 2 1 2", 3 1 2" and Indicators Maximum and Voltmeters 4 1 2" surface Demand with mount panel Indicator Selector meters PAGE utilising 5 Page 5 Switch PAGE 8-9 Moving pivot Coil and DC jewel Ammeters mechanisms and Voltmeters and offering PAGE IP54 6protection. The range DIN offers Combined Panel iron Meters vane Ac Ammeter and Long moving Scale and coil Maximum Specs/ AC and Demand DC ammeters PAGE Indicator and 10-11 Page 5 Moving Long Coil voltmeters, Scale Rectified Moving AC elapsed Coil Ammeters time AC and Ammeters and Voltmeters frequency and meters. Voltmeters PAGE UL approvals. PAGE 6 12 Process Long Indicators Scale Frequency PAGE 7Meters PAGE 12 Moving Moving Coil Dc Ammeters and Voltmeters Page 6 Long 016 Iron Scale Series AC Moving Ammeters Fiesta Coil Panel and DC Ammeters Voltmeters Indicators and with Voltmeters Selector PAGE Switch 13PAGE 8-9 25 27 DIN Panel Elapsed A robust Meters Time range Meters Long of short-scale (Hours Scale Specs/ Run 3 1 2" Meters) surface PAGE mount 14 PAGE panel 10-11 meters offering Moving IP55 Coil protection Rectified Ac and Ammeters featuring and wide-view Voltmeters contoured Page 6 Long Moving Scale Moving Coil Dual Coil AC AC Ammeters Ammeters & Voltmeters and Voltmeters PAGE 15PAGE 12 Long Dual Scale windows. Frequency Frequency The range Meters Meters offers PAGE PAGE iron 15vane 12 and moving coil AC and Phase DC Process ammeters Sequence Indicators and Indicators voltmeters, PAGE elapsed 16 time and frequency Page 7 Long Scale Moving Coil DC Ammeters and Voltmeters PAGE 13 Electronic meters. UL Phase approvals. Angle Meters PAGE 17 Elapsed Power Time Challenger Moving Factor Meters Iron PAGE (Hours AC Analogue Ammeter 18 Run Meters) PAGE 14 Panel and Voltmeters Meters with Selector Switch Page 28 8 32-9 Moving 360 Coil LED Dual Synchroscope AC Ammeters and & Synchro Voltmeters Check PAGE Relay 15 PAGE 19 Dual Wattmeters Frequency Challenger & analogue Meters VArmeters PAGE panel PAGE 15 meters 20-21 feature a detachable lower DIN fascia Panel plate, Meters which - allows Long Scale either : surface Specs and or window mounting. Phase Sequence Indicators PAGE 16 Page 10-11 Meters use a high torque pivot and jewel movement. - Electronic Phase Angle Meters PAGE 17 Power 078/080/087 Factor PAGE 18 Series Sealed and Ruggedised Indicators 33 37 360 LED Designed Synchroscope to comply and with Synchro industrial, Check marine Relay and military PAGE 19 Wattmeters specifications, & VArmeters these 240 PAGE and 20-21 90 scale meters are resistant to extreme shock, vibration, temperature, dirt and humidity. The range offers a wide range of bezel sizes fitted with toughened glass. Features Extensive range Accurate measurement and display of electrical and electronic parameters Wide range of case styles and specifications Maximum reliability in harsh environments Benefits Low cost Local indication Ease of installation Minimal training Low maintenance Reasonable accuracy Applications Switchgear Distribution systems Generator sets Control panels Energy management Building management Utility power monitoring Process control Motor control Approvals UL, CSA, ABS, LRS, BV 1

Features A range of the most popular shortscale measuring instruments in 4 case sizes Shock resistant sprung pivot and jewel movement Terminal covers supplied as standard EMC hard frequency meters are fully EMC and LVD compliant 1 /4" fast on terminals available Benefits Low cost Local indication Ease of installation Minimal training Low maintenance Customised options and features Applications Switchgear Distribution systems Generator sets Control panels Energy management Building management Utility power monitoring Process control Motor control Approvals Lloyds: 03/00055 - Moving coil meters 03/00056 - Moving iron meters 03/00057 - Frequency meters DIN Panel Meters Short scale A range of 48, 72, 96 and 144mm DIN style panel meters measuring all electrical parameters and featuring moving coil or moving iron movements. All meters incorporate slide-in dials and terminal covers as standard. A range of customised options is available. Movements Moving Coil Meter Centre cored, self shielding moving coil movement, using pivots, hairsprings and sprung jewels. Seven variations have been designed in movement ranges: all intermediate ranges are achieved by shunting the next lowest range. All DC voltmeters are 1000 ohms per volt, rectified product run at 900 ohms per volt, millivolt meters use the 5 milliamp movement. Moving Iron Meter Clapper type repulsion design using pivots, hairsprings and jewel movements. The bottom jewel is oil filled to provide damping while the top is sprung for resilience. All voltmeters are manufactured with external voltage dropper resistors to substantially reduce the self heating effects. Frequency Meter Meter uses a 100 microamp 4000 ohm movement driven by an EMC hard frequency conversion circuit. Dials, Scales and Pointers Standard dials are white matt with black printed scales and bar knife-edge pointers. Black dials with white or yellow scales and pointers are also available. Interchangeable slide-in dials are used on the E242, E243, E244 and E246 90 moving iron, moving coil and frequency meter models. General options include red supplementary pointers, red indexes (quadrant scales), red, green or blue lines, bands or segments, finely spaced divisions, multi-scales, special scales and captions to customer s requirements. Type of instrument Format Movement type Burden Accuracy Input type Measuring range Dielecric voltage withstand test Moving iron for Moving coil for Moving coil with Moving coil with Maximum Combined MDI current and current and rectifiers for built-in transducer demand with moving voltage voltage current and for frequency indicators iron movement voltage measurement 48 x 48mm 48 x 48mm 48 x 48mm 72 x 72mm 72 x 72mm 72 x 72mm 72 x 72mm 72 x 72mm 96 x 96mm 96 x 96mm 96 x 96mm 96 x 96mm 96 x 96mm 96 x 96mm 144 x 144mm 144 x 144mm 144 x 144mm 144 x 144mm Sprung pivot Sprung pivot Sprung pivot Sprung pivot Sprung pivot Sprung pivot jewel with silicon jewel with eddy jewel with eddy jewel with eddy jewel with silicon jewel with silicon oil damping current damping current damping current damping oil damping oil damping 0.5VA-15A See detailed See detailed See detailed 2.5VA 3VA then 0.8VA specifications specifications specifications voltmeters 4.5VA 1.5% to 1.5% to 2.5% to 0.5% to 3% 3% on MDI DIN43780 DIN43780 DIN43780 DIN43780 1.5% ammeter AC current or DC current or AC AC voltage AC current AC current voltage voltage current or voltage 6-600V 50mV-600V 15-600V 57.7V @ 45Hz 0-1/1.2A or 1-6A 8, 15 or 20 100mA-100A 100µA-40A, 1mA-100mA and 500V @ 44Hz 0-5/6A minute delays 48mm only up 44mm only 25A 1A & 5A 8, 15 or 20 0-5A/6A to 40A minute delays instantaneous 3kV AC 3kV AC 3kV AC 3kV AC 3kV AC 3kV AC 2

General Performance: Measuring ranges: Accuracy overload: : Scale marking generally to: Magnetic influence: Safety: Terminals: Humidity range: Test voltage @50Hz: Ammeter ranges: Overload AC current: AC voltage and frequency: Standard calibration: Operating temperature: Damping time: Enclosure code: Case and base: Case: Bezel: Bezel window: Installation: Fixing on panel: Mounting position: BSEN60051 DIN43701 BSEN60051 DIN43700 DIN43802 BSEN60051 BSEN61010-1 Clamp strap M4 for up to 25A. Clamp strap M8 for over 25A 1 /4" spade terminals available for models E243 and E244 Up to 95% RH (non condensing) 3kV RMS for 1 minute 1.0/1.2/1.5/2.5/5/6 and decade multiples thereof x 1.2 continuous x 10 for 5 seconds x 1.2 continuous x 2 for 5 seconds 23 C. Calibration at other temperatures available on request -20 C to +60 C Less than 3 seconds IP52 as standard IP54 on request Grade UL94V0 and panel cut out conform to IEC473, DIN43700. Case made from glass filled polycarbonate self-extinguishing and non drip in accordance with UL94V-O Slim-line DIN43802, black as standard Standard sheet glass, with zero adjusters where appropriate. Non reflecting glass or polycarbonate shatterproof windows are available Installations in switchboard panel or mosaic arrangement on equipment or machine with a panel thickness of up to 40mm in a horizontal or vertical plane Swivel captive fasteners, which can be fixed at either corner Normal vertical mounting or as indicated on the scale in accordance with DIN16257. A deviation of ±15 is permissible Insulation resistance more than 5MΩ@ 500V Insulation group: Environmental: Measurement category III IEC 1010-1 Pollution degree 2 IEC 1010-1 Electrical rating 600V RMS (920V peak) Approvals: EMC, LVD and Lloyds DIN16257 symbol meaning for calibration position Vertical Horizontal Inclined 60 Inclination of dial surface. Required orientation must always be stated when ordering if other than vertical mounting is required. Moving coil measuring range Moving iron measuring range 6-60A C=67mm 0-30A C=64mm >60A C=78mm >30A C=67mm Max. panel thickness = 40mm D A B 48 x 48 45 x 45 4 72 x 72 68 x 68 4 96 x 96 92 x 92 4 144 x 144 138 x 138 4 D 53 A B C C 3

Moving Iron AC Ammeters and Voltmeters Designed to measure AC current or voltage, these meters indicate true RMS values and are substantially independent of system waveform. Scales are calibrated down to 20%, and ammeters can have overload scales of x2, x3, x5 or x6 for motor start duty. Ammeters can be supplied for use with -/1A or -/5A current transformers, whilst voltmeters can be scaled for use with voltage transformers. Meters can be used to measure DC at reduced accuracy. AC Ammeter Accuracy: Class 1.5 50 or 60Hz, (400Hz on request) Burden at 50Hz: Ammeters: 0.5VA voltmeters: Up to 4.5VA maximum Ratings: Ammeters: 0.5-100A AC direct connected (40A for E242-75A and E246-02A) Maximum system voltage 600V AC Low load/high middle, maximum 10A Voltmeters: 6-600V Product Codes Bezel size mm 48 72 96 144 Scale length mm 42 65 94 145 AC Voltmeter AC ammeter E242-75A E243-02A E244-02A E246-02A x2 overload ammeter E242-752A E243-022A E244-022A - x3 overload ammeter E242-753A E243-023A E244-023A - x5 overload ammeter E242-755A E243-025A E244-025A - x6 overload ammeter E242-756A E243-026A E244-026A - AC voltmeter E242-75V E243-02V E244-02V E246-02V Frequency Meters Frequency meters use an integral electronic converter and a moving coil indicator. These easy to read meters have accuracy Class 0.5. Ratings: Burden: 100-125V AC 200-250V AC 380-440V AC* 500V AC* *Use E242-89A and 253-THZ in place of E242-41S for voltages over 380V Models available for use with VTs 0.5%: 45/55Hz, 55/65Hz, 45/65Hz, 360/440Hz 4VA maximum Product Codes Bezel size mm 48 72 96 Scale length mm 42 65 94 E242-41S E243-41S E244-41S 4

Maximum Demand Indicators The thermal/time characteristics of MDI meters monitor the most economic use of cable, fusegear and transformers. The directly heated bimetal element indicates mean RMS current over 8, 15, or 20 minutes, and a red slave pointer shows the highest value reached. The reset knob is wire sealable. Scales are calibrated to match the CT primary plus 20% overload. End values are selected from: 1.2, 1.8, 2.4, 3, 3.6, 4.8, 6, 7.2, 9 amps and their multiples of 10 and 100. Accuracy: Class 3 Options: 5A for use with separate CT 5/5A saturating CT 1/5A saturating CT Burden at 50 Hz: MDI - 2.5VA, CT - 2VA Overload withstand: Standard: 5 x FL for 5 seconds, 10 x FL for 1 second. With saturating CT: 10 x FL for 3 seconds, 20 x FL for 1 second 50/60Hz Maximum Demand Indicators Product Codes Bezel size mm 72 96 Scale length mm* 65 94 8 minute time lag without limiting CT for use with 5A CT E243-16B E244-16B 15 minute time lag without limiting CT for use with 5A CT E243-16A E244-16A 20 minute time lag without limiting CT for use with 5A CT E243-16J E244-16J * Scaled 0/100/120% of CT primary value. Combined AC Ammeter and Maximum Demand Indicator Where measurement of instantaneous and maximum demand currents are required, these instruments combine both movements in one case. The meter can also replace an existing AC ammeter. Meets the same specifications listed above. Accuracy: Moving iron ammeter: Class 1.5 MDI: Class 3 Burden at 50Hz: MI - 0.5VA, MDI - 2.5VA saturating CT - 2VA Product Codes Bezel size mm 72 96 Scale length mm* 65 94 8 minute time lag without limiting CT for use with 5A CT 3VA E244-16Q 15 minute time lag without limiting CT for use with 5A CT 3VA E243-16C E244-16C 20 minute time lag without limiting CT for use with 5A CT 3VA E244-16H * Scaled 0/100/120% of CT primary value. 5

Moving Coil DC Ammeters and Voltmeters Moving coil meters are suitable for all DC systems. The linear scale is calibrated down to zero and the accuracy maintained down to 10%. High currents are measured with separate shunts and suitably scaled indicators. Suppressed, centre and offset zero models are available. DC Voltmeter Accuracy: Class 1.5 Ratings: Ammeters: 100µA-25A 4/20mA suppressed zero 40A for model E242, E243 and E244 up to 100A Voltmeters: 50mV-600V 1/5V suppressed zero 50, 60, 75, 100, 150mV for use with shunts Impedance: Ammeters: 75mV internal shunt above 60mA Voltmeters: 1000Ω/V above 1V Product Codes DC Ammeter Bezel size mm 48 72 96 144 Scale length mm 42 65 94 145 Ammeters E242-89A E243-01A E244-01A E246-01A Ammeters suppressed zero E242-89R E243-01R E244-01R E246-01R Voltmeters E242-89V E243-01V E244-01V E246-01V Voltmeters suppressed zero E242-89S E243-01S E244-01S E246-01S Moving Coil Rectified AC Ammeters and Voltmeters For high frequency or linear full scale AC measurements, these instruments measure average values of sinusoidal waveforms and are scaled in RMS values. The high quality silicon bridge rectifier gives a linear scale down to near zero, where some compression occurs. AC Ammeter Accuracy: Ratings: Voltmeters: 1.5% ES Ammeters: 250µA-1A AC Over 1A via CTs 15-600V AC direct connected. models available for use with VTs 50/60Hz, (Single frequencies 25Hz - 3kHz on request) Product Codes AC Voltmeter Bezel size mm 48 72 96 144 Scale length mm 42 65 94 145 Ammeters E242-89B E243-01B E244-01B E246-01B Voltmeters E242-89W E243-01W E244-01W E246-01W 6

Process Indicators Meters are used to check process functions locally or remotely at centralised controls. These moving coil instruments offer a wide variety of electrical and mechanical readouts and are operated by transducer, tachogenerator, thermocouple, resistance bulb or other DC analogue signals. Suppressed, centre and offset zero models are available on request. Accuracy: Class 1.5 Ratings: 1, 2, 5, 10, 20mA 4/20mA suppressed zero Product Codes Bezel size mm 48 72 96 144 Scale length mm 42 65 94 145 AC current E242-89A E243-01A E244-01A E246-01A AC voltage E242-89V E243-01V E244-01V E246-01V Phase angle - E243-014 E244-014 - Watts - E243-015 E244-015 - VAr - E243-016 E244-016 - VA - E243-017 E244-017 - 7

Moving Iron AC Ammeters and Voltmeters with Selector Switch These 96mm and 72mm units offer Class 1.5 true RMS measurement of three-phase AC voltage or current with various switch notation options. The integral selector switch eliminates the necessity for a separate selector switch, saving valuable panel space and providing installation benefits. Both ammeters and voltmeters feature a slidein dial, scaled for VT or CT values to suit application primary values. Features Integral selector switch True RMS measurement Slide-in dials Scaled for customer VT or CT primary values DIN 72 and DIN 96 models Terminal cover as standard Shock resistant sprung pivot and jewel movement x2 overload ammeters Benefits Space and time saving Competitive cost Local indication Ease of installation Low maintenance Customised options and features Applications Switchgear Distribution systems Generator sets Control panels Energy management Building management Compliant with IEC61010-1B2001, EMC and LVD These robust moving iron meters incorporate a clapper type repulsion design which utilises a pivot, hairspring and jewel movement. The bottom jewel is oil filled to provide damping while the top is sprung for resilience. Voltmeters are manufactured with internal voltage dropper resistors. Product Codes AC Ammeters with Selector Switch Code Case size Full scale Switch deflection notation E243-02E-G-LS**-C7-AMP3 72mm 0/5 A AC OFF L1 L2 L3 E244-02E-G-LS**-C7-AMP3 96mm 0/5 A AC OFF L1 L2 L3 E243-022E-G-LS**-C7-AMP3 72mm 0/5/10A AC OFF L1 L2 L3 E244-022E-G-LS**-C7-AMP3 96mm 0/5/10A AC OFF L1 L2 L3 E243-02E-G-LA**-C7-AMP3 72mm 0/1 A AC OFF L1 L2 L3 E244-02E-G-LA**-C7-AMP3 96mm 0/1 A AC OFF L1 L2 L3 E243-022E-G-LA**-C7-AMP3 72mm 0/1/2A AC OFF L1 L2 L3 E244-022E-G-LA**-C7-AMP3 96mm 0/1/2A AC OFF L1 L2 L3 **Insert applicable CT primary value. Product Codes AC Voltmeters with Selector Switch Code Case Full scale Switch 3- size deflection notation phase E243-02Q-G-PM**-C7-SW6 72mm 0/120V AC 0FF L1L2 L2L3 L3L1 3W E243-02Q-G-PZ**-C7-SW6 72mm 0/150V AC 0FF L1L2 L2L3 L3L1 3W E243-02Q-G-PZ-PZ-C7-SW6 72mm 0/150V AC 0FF L1L2 L2L3 L3L1 3W E243-02Q-G-RX-RX-C7-SW6 72mm 0/300V AC 0FF L1L2 L2L3 L3L1 3W E243-02Q-G-SF-SF-C7-SW3 72mm 0/500V AC L1L3 L1L2 L2L3 L3N L2N L1N 4W E243-02Q-G-SJ-SJ-C7-SW3 72mm 0/600V AC L1L3 L1L2 L2L3 L3N L2N L1N 4W E244-02Q-G-PZ**-C7-SW6 96mm 0/150V AC 0FF L1L2 L2L3 L3L1 3W E244-02Q-G-PZ-PZ-C7-SW6 96mm 0/150V AC 0FF L1L2 L2L3 L3L1 3W E244-02Q-G-RX-RX-C7-SW6 96mm 0/300V AC 0FF L1L2 L2L3 L3L1 3W E244-02Q-G-SF-SF-C7-SW3 96mm 0/500V AC L1L3 L1L2 L2L3 L3N L2N L1N 4W E244-02Q-G-SF-SF-C7-SW3 96mm 0/600V AC L1L3 L1L2 L2L3 L3N L2N L1N 4W **Insert applicable VT primary and secondary value, e.g. 15kV/110V. Product Codes Options Description Non reflecting glass window Polycarbonate shatterproof window Red supplementary pointer, externally adjustable Red index mark (triangle) Please state any required options at time of ordering. 8

Moving Iron AC Ammeters and Voltmeters with Selector Switch General Accuracy: 1.5% of full scale deflection (FSD) Input rating: Ammeter: 1A, 5A 1/2A or 5/10A moving iron, direct connected Voltmeter: 120, 300, 500 and 600V AC 50 or 60Hz (400Hz on request) Burden at 50Hz: Ammeters: 0.5VA Voltmeters: 4-5VA max Overload ammeter: 2 x In continuous for 2 minutes, 4 x In for 1 minute Overload voltmeter: 1.2 x continuous 2 x for 5 seconds Movement: Moving iron shock resistant sprung pivot and jewel Scale length: DIN72: 54mm DIN96: 97mm Enclosure style: Panel mount to DIN42700 Enclosure material: Grade UL94 VO Bezel style: Black matt DIN43802 Window: Standard sheet glass Terminals: M4 captive screw clamp Fixing: 2 corner fixing clamps with tensioning thumb screws Mounting position: Vertical mount to DIN16257, inclination of dial surface ±15% Damping time: Compliant with: IEC61010-1B2001, CAT III 600V, EMC and LVD Operating temperature: -20 C to +55 C Storage temperature: -40 C to +75 C Calibration temperature: 23 C Relative humidity: 95% (non condensing) : 96DIN: 96mm high x 96mm wide x 63mm deep 72DIN: 72mm high x 72mm wide x 63mm deep Panel cut out: DIN96: 92mm x 92mm DIN72: 68mm x 68mm IP protection: IP40 Weight: E243-02E 275g E243-02Q 300g E244-02E 360g E244-02Q 390g AC Ammeters with Selector Switch 72DIN Models AC Voltmeters 3-phase 3-wire 96DIN Models AC Voltmeters 3-phase 4-wire 9

DIN Panel Meters Long Scale A range of 72mm and 96mm DIN style panel meters measuring all electrical parameters and featuring moving coil movements. All meters incorporate slide-in dials and terminal covers as standard. A range of customised options is available. Movements Features A range of the most popular long scale measuring instruments in 2 case sizes Shock resistant sprung pivot and jewel movement Terminal covers supplied as standard EMC hard frequency meter are fully EMC and LVD compliant Benefits Local indication Ease of installation Minimal training Low maintenance Customised options and features Moving Coil Meter Centre cored, self shielding moving coil movement, using pivots, hairsprings and sprung jewels. Seven variations have been designed in movement ranges: all intermediate ranges are achieved by shunting the next lowest range. All DC voltmeters are 1000 ohms per volt, rectified product run at 900 ohms per volt. Millivolt meters use the 5 milliamp movement. Frequency Meter Meter uses a 100 microamps 4000 ohm movement driven by an EMC hard frequency conversion circuit. Dials, Scales and Pointers Standard dials are white matt with black printed scales and bar knife-edge pointers. Black dials with white or yellow scales and pointers are also available. Interchangeable slide-in dials are used on the E243 and E244 240 moving coil and frequency meter models. Standard options include red supplementary pointers, and non-reflecting glass. Applications Switchgear Distribution systems Generator sets Control panels Energy management Building management Utility power monitoring Process control Motor control 10

DIN Panel Meters - Long Scale General Performance: BSEN60051 Measuring ranges: DIN43701 Accuracy overload: BSEN60051 : DIN43700 Scale marking generally to: DIN43802 Magnetic influence: BSEN60051 Safety: BSEN61010-1 Terminals: Clamp strap M4 for up to 25A. Clamp strap M8 for over 25A Humidity range: Up to 75% RH (non condensing) Test voltage @50Hz: 3kV RMS for 1 minute Overload AC current: x 1.2 continuous, or x 10 for 5 seconds max AC voltage and frequency: x 1.2 continuous, or x 2 for 5 seconds max Standard calibration: 23 C. Calibration at other temperatures available on request Operating temperature: -10 C to +55 C Damping time: Less than 3 seconds Enclosure code: IP52 as standard IP54 on request Case and base: Grade UL94V0 (Lexan 500R) Case: and panel cut out conform to IEC473, DIN43700. Case made from glass filled polycarbonate self-extinguishing and non drip in accordance with UL94V-O Bezel: Slim-line DIN43802, black as standard Bezel window: Standard sheet glass, with zero adjusters where appropriate. Non reflecting glass windows are available Installation; Installations in switchboard panel or mosaic arrangement on equipment or machine with a panel thickness of up to 40mm in a horizontal or vertical plane Fixing on panel: Swivel captive fasteners, which can be fixed at either corner Mounting position: Normal vertical mounting or as indicated on the scale in accordance with DIN16257. A deviation of ±15 is permissible Insulation group: Insulation resistance more than 5MΩ@ 500V Environmental: Measurement category III IEC 1010-1 Pollution degree 2 IEC 1010-1 Electrical rating 600V RMS (920V peak) Approvals: EMC and LVD DIN16257 symbol meaning for calibration position Vertical Horizontal Inclined 60 Inclination of dial surface. Required orientation must always be stated when ordering if other than vertical mounting is required. Moving coil measuring range 6-60A C=67mm >60A C=78mm D A B 72 x 72mm 68 x 68mm 4 96 x 96mm 92 x 92mm 4 D 53 A B C C 11

Long Scale Moving Coil AC Ammeters and Voltmeters Moving coil rectified instruments measure average values of sinusoidal waveforms and are scaled in RMS values. AC Voltage AC Ammeter inputs AC Voltmeter inputs 0/1A AC 0/60V AC 0/1.2A AC 0/100V AC 0/5A AC 0/120V AC 0/6A AC 0/125V AC 0/10A AC 0/140V AC 0/150V AC 0/250V AC 0/300V AC 0/400V AC 0/500V AC 0/600V AC AC Current Accuracy: Class 1.5 50/60Hz Impedance: Ammeters: 75mV internal shunt Voltmeters: 900 ohm/v Bezel size mm 72 96 Scale length mm 65 94 AC Ammeters E243-05B E244-05B AC Voltmeters E243-05W E244-05W Long Scale Frequency Meters Frequency meters use an integral electronic convertor and a moving coil indicator. Voltage inputs Frequency inputs 100/125V AC 45/55Hz 200/250V AC 45/55Hz 380/400V AC 45/55Hz 100/125V AC 55/65Hz 200/250V AC 55/65Hz 380/400V AC 55/65Hz Accuracy: Class 0.5 Burden: <7VA Bezel size mm 72 96 Scale length mm 65 94 Frequency meter E243-41L E244-41L 12

Long Scale Moving Coil DC Ammeters and Voltmeters Moving coil meters are suitable for all DC systems. The linear scale is calibrated down to zero and the accuracy maintained down to 10%. Suppressed and centre zero models are available. DC Ammeter inputs DC Voltmeter inputs 0/400uA DC 0/50mV DC 0/600uA DC 0/60mV DC 0/1mA DC 0/75mV DC 0/10mA DC 0/100mV DC 0/20mA DC 0/150mV DC 0/1A DC 0/2.5V DC 0/2.5A DC 0/10V DC 0/5A DC 0/30V DC 500/0/500uA DC 0/60V DC 1/0/1mA DC 0/100V DC 20/0/20mA DC 0/150V DC 4/20mA DC 0/250V DC 0/300V DC 0/400V DC 0/500V DC 0/600V DC 50/0/50mV DC 60/0/60mV DC 75/0/75mV DC 100/0/100mV DC 150/0/150mV DC 5/0/5V DC 10/0/10V DC DC Voltage DC Current Accuracy: Class 1.5 Impedance: Ammeters: 75mV internal shunt Voltmeters: 1000Ω/V Bezel size mm 72 96 Scale length mm 65 94 Ammeters E243-05A E244-05A Ammeters centre zero E243-05C E244-05C Ammeters suppressed zero E243-05R E244-05R Voltmeters E243-05V E244-05V Voltmeters centre zero E243-05N E244-05N 13

ELAPSED TIME METERS (HOURS RUN METERS) Elapsed Time/Hours Run Meters AC L1 L2 L3 Elapsed Time/Hours Run Meters DC + - L O A D L O A D Elapsed time meters (ETM) or hours-run meters monitor ON/RUN time of plant and equipment, allowing the user to effectively control production efficiency, cost estimation and service period monitoring for preventative maintenance. Time is measured in increments of 0.01h up to 99999.99 hours after which the meter automatically resets to zero. Meters are non-resettable before this time to prevent accidental resetting. AC Display: 99999.99 Voltage: 100-125V AC 200-250V AC 380-440V AC 50 or 60Hz Operating temperature: -25 C to +80 C IP Protection: IP52 Burden: 1VA (100-125V AC) 2VA (200-250V AC) 3.5VA (380-440V AC) DC Display: 99999.99 Voltage: 12-36V DC 10-80V DC 110V DC Operating temperature: -20 C to +70 C IP Protection: IP52 Burden: 0.5VA (12-36V AC) 1VA (10-80V AC) 1.5VA (110V AC) 0.5VA (6-30V) 1VA (36-80V) Bezel size product codes 48mm 72mm 96mm 100-125V AC 50Hz M242-155-G-PL-ZH-C5 M243-155-G-PL-ZH-C5 M244-155-G-PL-ZH-C5 200-250V AC 50Hz M242-155-G-RN-ZH-C5 M243-155-G-RN-ZH-C5 M244-155-G-RN-ZH-C5 380-440V AC 50Hz M242-155-G-RY-ZH-C5 M243-155-G-RY-ZH-C5 M244-155-G-RY-ZH-C5 100-125V AC 60Hz M242-156-G-PL-ZH-C6 M243-156-G-PL-ZH-C6 M244-156-G-PL-ZH-C6 200-250V AC 60Hz M242-156-G-RN-ZH-C6 M243-156-G-RN-ZH-C6 M244-156-G-RN-ZH-C6 380-440V AC 60Hz M242-156-G-RY-ZH-C6 M243-156-G-RY-ZH-C6 M244-156-G-RY-ZH-C6 6-30V DC - M243-157-G-BU-ZH-DC M244-157-G-BU-ZH-DC 12-36V DC M242-157-G-BU-ZH-DC - - 10-80V DC - M243-157-G-NR-ZH-DC M244-157-G-NR-ZH-DC 36-80V DC M242-157-G-NR-ZH-DC - - 110V DC M242-157-G-PM-ZH-DC M243-157-G-PM-ZH-DC M244-157-G-PM-ZH-DC PAGE 15

Moving Coil Dual AC Ammeters & Voltmeters Dual instruments can be used to measure a wide range of currents and voltages, and save both space and time by requiring only one panel cut out. The E244-80L allows for independent measurement of two AC voltages in one case. The E244-80F allows for independent measurement of two AC currents in one case. AC Ammeter inputs AC Voltmeter inputs 0/1A AC 0/120V AC 0/1.2A AC 0/150V AC 0/5A AC 0/300V AC 0/6A AC 0/500V AC 0/10A AC 0/600V AC Accuracy: Class 1.5 50/60Hz Impedance: Ammeters: 75mV internal shunt Voltmeters: 900 ohm/v Bezel size mm 96 Scale length mm 94 AC Ammeters E244-80F AC Voltmeters E244-80L Dual Frequency Meters Dual frequency instruments can be used to measure a wide range of frequencies, and save both space and time by requiring only one panel cut out. The E244-41D allows for independent measurement of two AC frequencies in one case. Voltage inputs Frequency inputs 100/125V AC 45/55Hz 200/250V AC 45/55Hz 380/400V AC 45/55Hz 100/125V AC 55/65Hz 200/250V AC 55/65Hz 380/400V AC 55/65Hz Accuracy: Class 0.5 Burden: <7VA Bezel size mm 96 Scale length mm 94 Frequency meters E244-41D 15

Phase Sequence Indicators Electronic phase sequence indicators ensure correct phase rotation and the presence of all 3-phase supplies. Incorrect or loss of phase can cause serious damage in a wide range of electrical machines. Ship-to-shore supplies, mobile generators and remote installations are particularly vulnerable to this problem. Voltage: 151/300V, 301/500V 100/150V (Model 244-12P only) 50/60Hz Burden: 2.5VA/phase Phase Sequence Indicators Bezel size mm 72 96 Phase sequence indicator 243-12P 244-12P 16

Phase Angle Meters Electronic Phase Angle Meters Phase angle meters indicate the phase displacement between current and voltage. They are used in applications where the phase angle must be monitored, for example with tariffs having VAr penalties, or to optimise generator power delivery. Accuracy: Class 1.5 Ratings: Current: 1A or 5A for CTs Voltage: 110V, 240V, 380V & 400V for VT use 50Hz, 60Hz Burden at 50Hz: Current: 1VA Voltage: 3VA per phase Current range: 20-120% 3-phase, 3-4-wire Balanced Systems Product Codes Short-Scale Models Bezel size mm 72 96 Scale length mm 65 94 3-phase 3/4-wire E243-42A E244-42A balanced load 17

Power Factor Power Factor indicators are suitable for generators or supplies operating in parallel. The scale calibrated cos 0.5-1 - 0.5 indicates power low for inductive and capacitive loads. Voltage inputs 1-phase 3-phase 3-wire 3-phase 4-wire Single-phase 63.5V AC 110V AC L/L 63.5V AC L/N 100V AC 120V AC L/L 69.3V AC L/N 110V AC 220V AC L/L 127V AC L/N 120V AC 230V AC L/L 132.7V AC L/N 220V AC 240V AC L/L 139V AC L/N 230V AC 380V AC L/L 220V AC L/N 240V AC 415V AC L/L 240V AC L/N 380V AC 440V AC L/L 254V AC L/N Current inputs 1A AC 1A AC 1A AC 5A AC 5A AC 5A AC Three Phase Balanced Load Accuracy: Class 1.5 Measuring ranges: Voltage: 85-115% Current: 20-120% Overload: 120% of rated voltage & current continuos Max Input: 600V 50/60Hz (45-65Hz max) Burden: Current: 0.2VA per phase Voltage: 1VA per phase Bezel size mm 96 Scale length mm 94 1-phase E244-135 3-phase 3-wire balanced load E244-136 3-phase 4-wire balanced load E244-13D 18

LED Synchroscope 360 LED Synchroscope and Synchro Check Relay Where manual parallelling of two AC systems is desired, the frequency of both systems can be monitored by an LED synchroscope. The systems are synchronised when the green LED is lit in the 12 o clock position. The instrument is rated for continuous operation and connection. For the semi-automatic parallelling of two AC systems, the voltage, phase displacement and the frequency of both systems can be monitored by this LED synchroscope and synchro check relay. Controls for voltage, phase angle, and time delay are provided. The systems are synchronised when the green triangular LEDs are lit together with the GEN/BUS green LEDs. A dead bus option is also available. Ratings voltage: 63.5, 110, 120, 220, 230, 240, 380, 400, 415, 440, 480V 110/120V (115V nominal) 220/240V (230V nominal) 380/480V (430V nominal) Volts AC or via VT 40/65Hz Burden at 50Hz: 4VA maximum Suitable for 1 or 3-phase systems Safety: IEC1010-1 (300V AC RMS installation degree 2) Dielectric: 4kV rms for 1 minute Isolation: BUS/GEN/RELAY Vibration: To Lloyds shipping specification *Phase difference: +0-20, +2% *Voltage difference: +0-20%, +/-2% 0-10% for models G and H *Time delay: 0-2.5 seconds +10% *Accuracy: Synchronisation at T.DC is +1 360 LED Synchroscope 360 LED Synchroscope and Synchro Check Relay *Only for the 360 LED synchroscope and synchro check relay. Bezel size mm 96 96 96 Scale length mm 360 LED 360 LED 360 LED 3- or 4-wire Synchroscope Synchroscope Synchroscope 40-65Hz and synchro check and synchro check relay (dead bus) 110/120V 244-14GG-POBX 244-14HG-POBX 220/240V 244-14GG-R5BX 244-14HG-R5BX 380/480V 244-14GG-RUBX 244-14HG-RUBX 63.5V 244-14AG-NXYY 244-14LG-NXBX 244-14DG-NXBX 110V 244-14AG-PMYY 244-14LG-PMBX 244-14DG-PMBX 220V 244-14AG-R4YY 244-14LG-R4BX 244-14DG-R4BX 230V 244-14AG-RQYY 244-14LG-RQBX 244-14DG-RQBX 240V 244-14AG-RRYY 244-14LG-RRBX 244-14DG-RRBX 380V 244-14AG-RUYY 244-14LG-RUBX 244-14DG-RUBX 400V 244-14AG-SCYY 244-14LG-SCBX 244-14DG-SCBX 415V 244-14AG-SBYY 244-14LG-SBBX 244-14DG-SBBX 440V 244-14AG-SHYY 244-14LG-SHBX 244-14DG-SHBX 480V 244-14AG-SEYY 244-14LG-SEBX 244-14DG-SEBX For the 244-14L and 244-14D models, the generator voltage is compared to the nominal input (bus) voltage specified at time of ordering. For the 244-14G and 244-14H models, the generator voltage is compared to the measured bus voltage. v 19

Power Wattmeters & VArmeters Self contained Wattmeters and VArmeters are able to measure active and reactive power in both balanced and un-balanced, single-, 3-phase 3-wire and 3-phase 4-wire systems. Wattmeters are ideal for clear precise analogue indication of power in applications such as power generation, industrial control and power distribution. Voltage inputs 1-phase 3-phase 3-wire 3-phase 4-wire 63.5V AC 110V AC L/L 63.5V AC L/N 100V AC 120V AC L/L 69.3V AC L/N 110V AC 220V AC L/L 127V AC L/N 120V AC 230V AC L/L 132.7V AC L/N 220V AC 240V AC L/L 139V AC L/N 230V AC 380V AC L/L 220V AC L/N 240V AC 415V AC L/L 240V AC L/N 380V AC 440V AC L/L 254V AC L/N Current inputs 1A AC 1A AC 1A AC 5A AC 5A AC 5A AC 20 Accuracy: Class 1.5 Measuring ranges: Voltage: 85-115% Current: 20-120% Overload: 120% of rated voltage & current continuos Max Input: 600V 50/60Hz (45-65Hz max) Power factor: Unity power factor assumed range 0.5/1/0.5 Burden: Current: 0.2VA per phase Voltage: 1VA per phase Bezel size mm 96 Scale length mm 94 Wattmeter Product Codes 1-phase E244-210 3-phase 3-wire balanced load E244-211 3-phase 4-wire balanced load E244-21C 3-phase 3-wire unbalanced load E244-213 3-phase 4-wire unbalanced load E244-214 VArmeter Product Codes 1-phase E244-310 3-phase 3-wire balanced load E244-311 3-phase 4-wire balanced load E244-31C 3-phase 3-wire unbalanced load E244-313 3-phase 4-wire unbalanced load E244-314 Product Codes - Long Scale Bezel size mm 96 Scale length mm 150 Wattmeter Product Codes 1-phase E244-215 3-phase 3-wire balanced load E244-216 3-phase 4-wire balanced load E244-21D 3-phase 3-wire unbalanced load E244-218 3-phase 4-wire unbalanced load E244-219 VArmeter Product Codes 1-phase E244-315 3-phase 3-wire balanced load E244-316 3-phase 4-wire balanced load E244-31D 3-phase 3-wire unbalanced load E244-318 3-phase 4-wire unbalanced load E244-319 v

Active Power Single-phase (one element) Reactive Power Single-phase (one element) Three-phase, three-wire AC supply with balanced load (One element) Three-phase, three-wire AC supply with balanced load (One element) Three-phase, four-wire AC supply with balanced load (One element) Three-phase, four-wire AC supply with balanced load (One element) Three-phase, three-wire AC supply with unbalanced load (Two element) Three-phase, three-wire AC supply with unbalanced load (Two element) Three-phase, four-wire AC supply with unbalanced load (Three element) Three-phase, four-wire AC supply with unbalanced load (Three element) 21