Dawson DDM190D. Digital Multimeter User s Manual

Similar documents
Dawson DAN100. Analog Multimeter User s Manual

Dawson DSM170 Multi-Function Moisture Meter User s Manual

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

Digital Multimeter User's Manual

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

OPERATING INSTRUCTIONS

User Guide. Model Insulation Tester / Megohmmeter. Introduction

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

OPERATING INSTRUCTIONS

BENCHTOP INSTRUMENT BENCH TYPE DIGITAL MULTIMETER DM-1140B OPERATION MANUAL V2.0

Phase Sequence Tester

OPERATING INSTRUCTION

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

362 Clamp Meter. Users Manual

INSTRUCTION MANUAL DM5B Fax: (503)

Model UT601: OPERATING MANUAL

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

Mini Multimeter with Non-Contact Voltage Detector (NCV)

5.2 PRE-OPERATION PROCEDURE WARRANTY

KMP Insulation-Continuity Tester. Users Manual

User Guide. Model Insulation Tester / Megohmmeter

User Guide. Model Insulation Tester / Megohmmeter

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Digital/Analog Megohmmeter Model 1026

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

362 Clamp Meter. Users Manual

Table of Contents Title Page No.

Digital/Analog Megohmmeter Model 1026 USER MANUAL

365 Detachable Jaw True-rms Clamp Meter

OPERATING INSTRUCTION

Item ref: UK & UK MTB01 & MTB02 DIGITAL MULTITESTERS. User Manual

USER MANUAL. Insulation Tester + DMM. Model MG320

True RMS Autoranging Multimeter

Model UT602/603: OPERATING MANUAL

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

Model Battery Powered Milliohm Meter

Autoranging Industrial Multimeter

INSTRUCTION MANUAL IDM93N DIGITAL MULTIMETER EN FR IT DE

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

323/324/325 Clamp Meter

Users Manual. Phase Rotation Indicator

Safety design conforming to the following provisions

Autoranging Multimeter

373 Clamp Meter. Users Manual

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

INSTRUCTION MANUAL IDM97II DIGITAL MULTIMETER EN FR IT DE

TABLE OF CONTENTS 1. FEATURES SPECIFICATIONS... 1

HD110C Heavy-Duty Digital Multimeter

User's Guide. True RMS Multim eter. Extech 430

MODEL No: TA SAFETY INSTRUCTIONS 2. FEATURES. fig.1. Original Language Version

Model Insulation Tester / Megohmmeter. User Manual

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

707Ex. Users Manual. ma Calibrator

Manual Supplement. For IEC V, CAT I & 600, CAT II Meters only. Serial NO and greater.

Calibration Manual. Detachable Jaw True-rms Clamp Meter

Instruction Manual ICM A1 AC/DC Clamp Meter ICM A1

General Specifications

Temperature Calibrator

INSTRUCTION MANUAL IDM67 DIGITAL MULTIMETER

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

Visit us at

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

Safety design conforming to the following provisions

DIGITAL MULTIMETER INSTRUCTION MANUAL

i400s Calibration Information Introduction

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T )

Users Manual. MegOhmMeter

233 True-rms Remote Display Digital Multimeter Safety Information

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

Volt/mA Calibrator. Manual

Model ST Instruction Manual. Digital Insulation Tester. reedinstruments. www. com

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

Digital Multimeter AHMAD FOUAD ALWAN

OPERATING INSTRUCTIONS


TES-1601 INSTRUCTION MANUAL AUTORANGING INSULATION TESTER SAFETY INFORMATION TES ELECTRICAL ELECTRONIC CORP. Warnings and Safety symbols:

INSTRUCTION MANUAL IDM91E DIGITAL MULTIMETER EN FR IT DE JP

302+/303 Clamp Meter. Users Manual

Instruction Manual IVT-10 / IVT-20 Voltage Tester

Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING

27 II/28 II. Digital Multimeters. Getting Started Manual. Specifications

717 Series. Pressure Calibrators. Instruction Sheet. Introduction

ANALOGUE INSULATION-CONTINUITY and VOLTAGE METER

OPERATING INSTRUCTION

User's Manual. Earth Ground Resistance Tester. Model Introduction

WENS30C Loop Calibrator

OPERATION MANUAL MILLIAMP PROCESS CLAMPMETER MODEL - KM 071 LIST OF PRODUCTS

1.Safe testing IMPORTANT:

3-1/2 Digit LCD Multimeter with Tachometer Kit

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

80 Series V Digital Multimeter Safety Information

4-20mA DC PROCESS CLAMP METER

i3000s/i2000 Flex AC Current Probe

MEGOHMMETER. User Manual

Transcription:

Dawson DDM190D Digital Multimeter User s Manual

TABLE OF CONTENTS LIMITED WARRANTY AND LIMITATION OF LIABILITY... 3 Out of the Box... 3 Accessories... 4 Safety Information... 7 Certification... 7 INTRODUCTION... 7 Overview... 7 Figures and Components... 8 Buttons and Components... 8 Display Description... 10 USING THE METER... 10 Preparation... 10 DC/AC Voltage Measurement... 11 DC/AC Current Measurement... 12 Resistance Measurement... 13 Diode Test... 14 Continuity... 15 1

Logic Test... 16 Data Hold... 17 Maximum and Hold... 17 Auto Off... 17 SPECIFICATIONS... 18 General Specification... 18 Technical Specification... 19 MAINTENANCE AND REPAIR... 23 Repair... 23 Test Leads Replacement... 24 Replacing Batteries... 24 CONTACT DAWSON... 25 FEATURES... Back Page 2

LIMITED WARRANTY AND LIMITATION OF LIABILITY This instrument from Dawson Tools Inc. will be free from defects in workmanship and material for three years from the date of original purchase. This warranty does not cover defects resulting from damage caused by the user such as drops, neglect, misuse, unauthorized alteration, usage outside of specified conditions, contamination, or improper repair/maintenance. To receive service on the instrument if it becomes necessary during the warranty period, contact your nearest Dawson authorized service center at (800) 898-6991 or visit www.dawsontools.com to obtain a return authorization (within the US only). A return authorization is necessary before returning any instrument to Dawson; no service will be provided without a return authorization. The user is responsible for properly packing the unit and charges such as shipping, freight and insurance charges. The extent of Dawson's liability is limited solely to the repair/replacement of the instrument. The above warranty in its entirety is inclusive and no other warranties, written or oral, are expressed or implied. Out of the Box Check the Meter and accessories thoroughly before using the Meter. Contact your local distributor if the Meter or any components are damaged or malfunction. 3

Accessories Test Leads 1pc Alligator Clip & cable 1pc 1.5V AAA Battery 2pcs Case 1pc User s Manual 1pc Safety Information WARNING TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, PRODUCT DAMAGE OR PERSONAL INJURY, PLEASE FOLLOW THE SAFETY INSTRUCTIONS DESCRIBED IN THE USER MANUAL. READ THE USER MANUALS BEFORE USING THE METER. WARNING TO ENSURE SAFE OPERATION AND LIFE OF THE METER, DO NOT PLACE THE METER IN ANY ENVIRONMENT WITH HIGH PRESSURE, HIGH TEMPERATURE, DUST, EXPLOSIVE GAS OR VAPOR. 4

5 Avoid shaking, dropping or any kind of impacts when using or transporting the Meter. To avoid electric shock or personal injury, repairs or servicing not covered in this manual should be performed only by qualified personnel. Avoid direct exposure to sunlight to ensure extended life of the Meter. Do not place Meter in a strong magnetic field; this may cause false readings. Use only the batteries indicated in the Technical Spec. Avoid exposing batteries to humidity. Replace batteries as soon as the low battery indicator appears. Please keep the original packing for future shipping purposes (ex. Calibration) After opening the box, check for any damage during delivery.

Safety Symbols Important safety information, please refers to the user s manual Earth ground Indicates compliance with requirements for double insulation Fuse must be replaced with ratings specified in the manual. Important Safety Information Never use the Meter to measure voltages that might exceed 600V DC/AC above earth ground in category II installations. Always be careful when working with voltage above 60V DC or 30VAC RMS. Keep fingers behind the probe barriers while measuring. Inspect test leads and probes for cracks, breaks or crazes on the insulation before using the Meter. Repair or maintenance should be implemented by trained personnel. 6

Certification CAT II: This meter has meet IEC1010-1 standard with an overvoltage category (CAT II) and pollution2. The Meter is compiled to EMC requirements. Introduction Overview The DAM190D is a portable pen-type digital multimeter featuring 5V logic level test, DC/AC voltage and current measurement, auto/manual range, maximum and hold reading, auto power off, and LCD built in for easy reading. The slim and lightweight design with retractable probe is mobile and ideal for both professionals and hobbyists. 7

Figures and Components Buttons and Components 1. Retractable Probe 2. Rotatable Probe knob 3. LED Indicator 4. Protective Ring 5. Rotary Switch 6. DATA-H (Hold) Button 7. RANGE Button 8. MAX.H (Hold) Button 9. FUNC. Button 10. Panel 11. LCD Display 12. COM Jack Front Panel 8

Buttons and Components Description RANGE Button FUNC.F Button DATA-H Button MAX.H Button Rotary Switch Choose auto or manual range Switch between AC/DC or between resistance, continuity or diode Data reading hold Disable auto power off. Measure and hold for maximum reading To select different functions Probe Input terminals for V/A/Ω/ / and Logic COM Probe knob Protective Ring Common terminal Rotate the knob to retract probe Keep hand behind the ring for safety 9

Display Description AC DC M.H D.H AUTO Alternating Current Direct Current AC or DC Diode Buzzer Maximum reading Hold Data hold Auto range Low battery indicator Using the Meter Preparation Select a function and a range for the item to be measured using the rotary switch and RANGE button. In manual range, if the range to be measured is unknown, start off with the highest range. 10

In manual range, OL is displayed when overload occurs. Choose a higher range if possible to acquire correct reading. To perform measurement, first connect the test lead to common (COM), then connect the probe tip of the Meter to the circuit to be tested. If the battery voltage is less than 2.4V, is displayed, please change a new battery. DC/AC Voltage Measurement WARNING USE CAUTION WHEN MEASUREING HIGH VOLTAGE CIRCUITS TO AVOID ELECTRICAL SHOCK AND INJURY. DO NOT TEST VOLTAGES HIGHER THAN DC/AC 600V. Rotate the probe knob clockwise to extend the probe from the Meter. Insert the black test lead or test clip in the COM jack. Set the rotary switch to the V position. Press the "FUNC.F" button to switch between DC and AC measurements. Manual range can be 11

chosen by pressing the RANGE button. Hold RANGE to go back to Auto range. Connect the probe tip of the Meter and tip of the test lead (or test clip) across the power source or load. Read the measurement from LCD display. The polarity of the Meter s probe will be indicated. NOTE: In small voltage range, the Meter may show unsteady reading when test leads are not connected to the circuit, this is normal because of the sensitivity of the Meter. When the Meter is connected to the circuit, true readings will be displayed... DC/AC Current Measurement WARNING USE CAUTION WHEN MEASUREING HIGH VOLTAGE CIRCUITs TO AVOID ELECTRICAL SHOCK AND INJURY. DO NOT TEST VOLTAGES HIGHER THAN DC/AC 600V. Rotate the probe knob clockwise to extend the probe from the Meter. 12

Insert the black test lead or test clip in the COM jack. Set the rotary switch to the ma position. Press the "FUNC.F" button to switch between DC and AC measurements. Manual range can be chosen by pressing the RANGE button. Hold RANGE to go back to Auto range. Connect the probe tip of the Meter and tip of the test lead (or test clip) across the power source or load. Read the measurement from LCD display. The polarity of the Meter s probe will be indicated. Resistance Measurement WARNING TO AVOID ELECTRICAL SHOCK AND INJURY POWER OFF THE CIRCUIT AND DISCHARGE THE CAPACITANCE BEFORE MEASURING RESISTANCE. Rotate the probe knob clockwise to extend the probe from the Meter. Insert the black test lead or test clip in the COM jack. 13

Set the rotary switch to the position. Manual range can be chosen by pressing the RANGE button. Hold RANGE to go back to Auto range. Connect the tip of the Meter probe and test lead (or test clip) across the resistance or circuit under measurement and read of the reading from LCD. NOTE: o o The Meter may take a few seconds to reach steady reading if the measuring resistance is above 1MΩ. When the input is not connected (i.e. an open circuit) the figure OL will be displayed. Diode Test Rotate the probe knob clockwise to extend the probe from the Meter. Insert the black test lead or test clip in the COM jack. Set the rotary switch to the position. Press FUNC. to choose diode measurement; displayed. Connect leads to the circuit terminals. Read the measurement from the display. 14 is

NOTE: The Meter shows the forward voltage drop. If the lead connection is reversed, OL is displayed. Continuity WARNING TO AVOID ELECTRICAL SHOCK AND INJURY POWER OFF THE CIRCUIT AND DISCHARGE THE CAPACITANCE BEFORE MEASURING CONTINUITY. Rotate the probe knob clockwise to extend the probe from the Meter. Insert the black test lead or test clip in the COM jack. Set the rotary switch to the position. Press FUNC. to choose continuity test; appears on LCD. Connect leads to the circuit terminals. If continuity exists (i.e. resistance is less than 50 ), built-in buzzer will sound. If the result is an open circuit (or the circuit resistance measured is higher than 200 ) 0L is displayed. 15

Logic Test NOTE: The logic test will only work for 5V Signals. Make sure the retractable probe is stored back in the Meter. Insert the black test lead or test clip in the COM jack. Set the rotary switch to the LOGIC position. Connect the black test clip to the GND(-) of the circuits being measured. Hold the FUNC button and touch the probe tip to the circuit. Observe the logic state from LED indicator; Red LED light expresses high level/logic 1 and orange LED light expresses low level/logic 0. If the reading is between 1.5-3.5V, neither light will be on. You can also see or on the LCD display; expresses high level/logic 1 and expresses low level/logic 0. 16

Data Hold To hold the reading of a measurement, press DATAH button once. D.H will appear on the LCD, reading will be held. Press again to cancel holding value. Maximum and Hold To show the maximum value of the measurement and hold that value, press MAX.H button once. MAX.H will appear on the LCD, reading will be held. Press again to cancel holding maximum value. Auto Off When not in use, the Meter will automatically turn off after 15 minutes. After auto off, press any button to bring the power back on. The Meter will beep 5 times 1 minute before and a long beep right before it turns off. Hold DATA.H button followed by turning on the Meter to disable auto off. 17

Specifications General Specification Auto and Manual Range. Max. Voltage between Terminals and Earth Ground: 600V DC or AC Maximum Operating Altitude: 7000 Ft (2000m). Display: 0.79 In. (20mm) LCD Maximum Number: 1999 Polarity Indication: - Indicates negative polarity. Overload Indication: Display OL Sampling Time: Approx. 0.4 second/time Low Battery Indication: Auto Power Off: 15 min. Power Supply: 1.5V 2 AAA battery Operating Temperature: 32 F To 104 F(0 To 40 ) Storage Temperature: 10 F To 122 F(-10 To 50 ) Dimension: 8.2x1.5x1.14 in. (208 38 29mm) Weight: Approx. 3.9oz (110g) including battery 18

Technical Specification DC Voltage Range Resolution Accuracy 200mV 0.1mV 2V 0.001V 20V 0.01V ± (0.7% + 2 counts) 200V 0.1V 600V 1V Input Impedance: 10MΩ Overload Protection: o 200mV range: 250V DC or AC rms o 2V to 600V ranges: DC 600V or AC 600V rms Max. Input Voltage: 600V DC AC Voltage Range Resolution Accuracy 200mV 0.1mV 2V 0.001V ±(0.8% + 3 counts) 19

20V 0.01V ±(0.8% + 3 counts) 200V 0.1V 600V 1V ±(1.0% + 3 counts) Input Impedance: 10MΩ Overload Protection: o 200mV range: 250V DC or AC RMS o 2V-600V ranges: DC 600V or AC 600V rms. Frequency Range: 40 to 400Hz Response: Average (sine wave RMS) Maximum Input Voltage: 600V AC RMS DC Current Range Resolution Accuracy 20mA 0.01mA 200mA 0. 1 ma ±(1.5% + 3 digits) Overload Protection: Resettable fuse. 20

AC Current Range Resolution Accuracy 20mA 0.01mA 200mA 0. 1 ma ±(2.0% + 3 digits) Overload Protection: Resettable fuse. Frequency Range: 40 to 200Hz Response: Average Resistance Range Resolution Accuracy 200Ω 0.1Ω ±(1.0% + 3 counts) 2kΩ 0.001kΩ ±(1.0% + 1 counts) 20kΩ 0.01kΩ ±(1.0% + 1 counts) 200kΩ 0.1kΩ ±(1.0% + 1 counts) 2MΩ 0.001MΩ ±(1.0% + 1 counts) 20MΩ 0.01MΩ ±(1.0% + 5 counts) Open Circuit Voltage: 0.25V Overload Protection: 250V DC or AC RMS 21

Diode Resolution Function 0.001V reads diode forward voltage Forward DC Current: 1mA Reversed DC Voltage: 1.5V Overload Protection: 250V DC or RMS AC Continuity Function If resistance is lower than 50 built-in buzzer will make sound. Open circuit voltage: 0.5V Overload Protection: 250V DC or RMS AC Logic Test Range 0V 1.5V 3.5V 5V Low "0" High "1" Green LED on Green, Red LED off Input Impedance: approx. 1MΩ Overload Protection: 250V DC or RMS AC Red LED on 22

Maintenance and Repair Repair Please follow the steps closely if the Meter is not functioning properly: Check batteries; replace with new batteries if low battery indicator appears. Follow User s Manual to confirm all procedures. Before sending Meter back for repair, include a description of the problems encountered. Remove batteries and pack Meter well to avoid damage in delivery, Dawson does not cover damage due to delivery. Repair or service not covered in this manual should be performed only by the authorized service center or qualified personnel. 23

Test Leads Replacement WARNING REPLACE THE TEST LEADS WITH IDENTICAL OR COMPATIBLE LEADS. LEAD SPEC:600V 10A. Replace new leads if the current leads are worn. Replacing Batteries Follow these steps to replace batteries: Turn off the Meter. Loosen the battery compartment door screw, and remove the door from the case bottom. Remove the batteries and replace the batteries with new batteries. Reattach the battery compartment door to the case bottom and tighten the screw. 24

Contact Dawson Dawson Tools, Inc. 1142 S. Diamond Bar Blvd., #858 Diamond Bar, CA 91765 Phone: (310) 728-6220 www.dawsontools,com Do not recycle (Back page) Features 25 LCD Display Auto And Manual Range Auto Power Off Logic Level Test Diode Test Audible Continuity MAX Display Retractable Tip Data Hold Battery Low Indicator