Off-line filter / cooler unit FGSL

Similar documents
Oil/air cooler BLK. Fluidcontrol

Oil/air cooler BLK ATEX-3GD

Oil/air cooler BLK. Fluidcontrol

Oil / air cooler Series BLK-DC

Off-line filter / cooler unit BKF

Off-Line Filter BNF. FluidControl

Circulation pumps BFP-ATEX-T3/T4

Off-line filter units BNF. Installation and Operation Instructions. Original instructions. Fluidcontrol BE /2019

Oil/Air Cooler Units. Standard series EL Type. Test procedure certified following EN 1048

Oil/Air Cooler Units. Standard series OK-P type. Test procedure certified following EN

Feed Pumps VP / VPB / VPBM

Oil/Air Cooler Units. Compact application with AC Motor OK-ELC Type. Test procedure certified following EN 1048

Oil Filter Module Pi 8300

Oil/Air Cooler Units. Mobile series with DC motor OK-ELD Type. Test procedure certified following EN 1048

Duplex Filter Pi Features. Nominal pressure 10/16 bar (140/230 psi), nominal size 1250 up to 8000

Oil/Air Cooler Units. Compact application with AC Motor OK-ELC Type

Sample gas pumps P2.x ATEX

Off-line Oil Filter Module Pi 8400

Automatic back-flushing filter AutoFilt RF4

Sample gas pumps P 2.3, P 2.3C, P 2.83, P 2.4, P 2.4C, P 2.84

Oil Filter Module Pi 8300

Line filter Pi Features. Nominal pressure 16 bar (230 psi), nominal size 400 up to 6000

Process screen basket filter PRFS

OFFLINE SERIES GLOBAL STANDARD COOLER

Compact hydraulic power unit Type BKA

Air Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11

Suction Filter Pi 200

BYPASS SERIES GLOBAL STANDARD COOLER

GLOBAL STANDARD COOLER

Change-Over Pressure Filter DFDK

Change-Over Inline Filter RFLD Welded Version

Pressure Filter DF...K P, DF...M P, Flange Mounted

FNA 045 Operating pressure up to 7 bar / 101 psi Nominal flow rate up to 45 l/min / 12 gpm

Return Line Filter HF4R up to 450 l/min, up to 10 bar

A-L O C COOLING SYSTEM OLAER COOLERS. Olaer A-LOC with integrated circulation pump for industrial hydraulic systems

Automatic metal-edge filters AF 72 G

Process Inline Filter PLF1

Return line and Suction Boost Filter RKM

Inline Filters NF. Flow rates up to 3,500 l/min Pressure range 25 bar Material: Aluminium / Aluminium-Cast Iron

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

Duplex Filter Pi Features. Nominal pressure 40 bar (580 psi), nominal size up to 300

Automatic metal-edge filter AF 73 G/AF 93 G

Tank top return-line filter Pi 5000

Process Inline Filter Protective filter PLF2-9HF

FNA 008 FNA 016 Operating pressure up to 4 bar / 58 psi Nominal flow rate up to 16 l/min / 4.2 gpm

Return Line Filter RFM with 4-Hole Mounting

Automatic filter AF 173 G

Oil/Air Cooler Units

OFFLINE SERIES GLOBAL STANDARD COOLER. p f

Backflushing Filter AutoFilt RF3

Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF

Cooling Systems CC Series TT rail 20/30lpm

Filter cooler unit with inline filter according to DIN Type ABUKG. Contents. Features. RE Edition: Replaces: 50126

LKI LKI-HYD COOLING. Series. advanced quality customized designs made in europe. Oil/Air heat exchangers. Low noise level. High performance.

Air Cooler Mobile AC-LNH 8-14 with hydraulic motor

High Pressure Filter Pi 4230

Return Line Filter RF

Low Pressure Filter Pi 200

Automatic filter AF 172 G

Mobile Filter Units Pi 8100

Oil/Air Cooler Units. Mobile application and Hydraulic motor OK ELH Type. Test procedure certified following EN 1048

Backflushing Filter AutoFilt RF4

Low Pressure Filter Pi 200

GLOBAL STANDARD COOLER

Duplex Filter Pi Features. Nominal pressure 25 bar (360 psi), nominal size 800 and 1400

Duplex Filter Pi Features. Nominal pressure 40 bar (570 psi), nominal size 800 and 1100

Process Inline Filter Medium / High Pressure PFM / PFH

Automatic filter AF 113 G

Automatic filter AF 112 G

A complete line of pressure differential visual and electrical indicators are available with this series of filters.

NCF fans 50 Hz. Protection class IP 55

FILTERS. PUMP CARE - Suction filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW

Suction return line filter Pi 550

Oil / water cooler Series BWT

Pressure Filter DF Pressure Filter for Reversible Oil Flow DFF/DFFX

LMP series. 305 Low & Medium Pressure filters MULTIPORT. Maximum pressure up to 80 bar - Flow rate up to 200 l/min

Automatic filter AF 113 G

Suction Filter Pi 160

Return Line Filter RFM with 4-Hole Mounting

Process Multi-Rheo Filter PMRF

GLOBAL STANDARD COOLER

Inline filters NF NF 1350 NF 330 NF 750 NF 500 NF FILTER SPECIFICATIONS Nominal pressure

Filter module AF Features. MAHLE Industrialfiltration is now Filtration Group. For more information, visit

HEAT EXCHANGERS AIR/OIL TYPE LAC. - ATEX Version. Approved for applications where there may be an explosive environment above ground.

Inline Filter LPF D A Flange-Mounted up to 280 l/min, up to 25 bar

12CS Series. Coreless Spin-on Filter Max. 75 l/min - 35 bar. Environmentally friendly alternative for spin-in filtration.

Medium Pressure Filter Pi 340

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane

Duplex Filter Pi 4700

Low Pressure Filter/Suction Filter Pi 270

FA 016 FAPC 016. Oil Service Units. Description. Page 53

PS/PSL Centrifugal pumps

Suction Filter SF/SFM/SFF and Suction Filter Elements S/S..

IPVP High-pressure Internal Gear Pumps for Variable Speed Drives

Change-Over Inline Filter AFLD to API 614

Twin City Fan & Blower

High Pressure Filter Pi 422

Duplex Filter Pi 2100

VARIO. VARIO Separation of fine dust particles. The VARIO series is particularly suitable for separation of fine dust.

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T )

Transcription:

Fluidcontrol Off-line filter / cooler unit FGSL Coolers are used to stabilise the operating temperature in hydraulic and lubrication systems. This can be implemented particularly cost-efficiently by integrating the cooler in a bypass circuit. The required cooler size can be calculated much more accurately if the flow rate and cooling capacity specifications are definite. At the same time, the bypass circuit can also be used to integrate the working filter. The stable recirculated volumes and low system pressure allow the use of less expensive filter housings. Another advantage is easier maintenance. The filter element can be replaced without shutting down the entire system. The compact design of Bühler FGSL off-line filter units meet the requirements in application quite well and can also easily be retrofit in existing systems. Features Easy to maintain design Compact design Low noise emission Rugged cooling matrix Extensive accessories High suction pump Easy to integrate in existing systems Low pressure filter with a wide separation range and filtration capacity DE270001 03/2018 page 1 / 8 Bühler Technologies GmbH, Harkortstr. 29, D-40880 Ratingen Tel. +49 (0) 21 02 / 49 89-0, Fax: +49 (0) 21 02 / 49 89-20 E-Mail: fluidcontrol@buehler-technologies.com Internet: www.buehler-technologies.com

Introduction and description Why coolers? In many cases, installing an off-line cooler is not only an emergency solution, but often the best solution with respect to mechanics and economics. Off-line filtration can usually also be incorporated quite effectively. Since a bypass also always requires installing a separate circulation pump, it s reasonable to connect it to the existing fan motor. The FGSL series is a tiered line of oil/air coolers with directly flange-mounted circulation pump. The cooler size and pump flow rate are coordinated for performance grades compatible with the system. The gerotor pump ensures the entire unit is emits very little noise. Why Bühler? When we developed the BNK series, we incorporated our years of experience in designing and selling oil/air coolers and combined units. Especially the fatigue life of the cooling matrix was a focus during development. The cooling matrix can easily be removed from the fan case for maintenance without removing the fan or motor. If our comprehensive standard range of products does not include the right solution for your application, we will gladly find a solution specific to your needs. Use the data in this leaflet to find a unit suitable for your application. Construction and application The FGSL s consist of the following components: cooling matrix (1), fan case (2) with mounting rails (7), blower and pump unit consisting of three-phase motor (5), pump (6), fan (3), protective/mounting grate (4) and motor bracket (8), attached low pressure filter (9) with built-in bypass valve and mechanical/ visual contamination indicator (10). The cooling matrix and fan/pump unit can be removed from the fan case individually without having to remove other components. The cooling matrixes in the FGSL series are aluminium. The coolers are designed for use in hydraulic circuits. 2 Bühler Technologies GmbH We reserve the right to amend specification. DE270001 03/2018

Filtration We offer a wide range of filter elements to use in the filter housing. Contact us for an in-depth consultation. Equipment Expansion (upon request) We also offer cooling matrix versions with interior or exterior bypass and upgrades with various sensors. For example pressure gauge, pressure transmitter 4-20 ma, pressure switch, thermometer and temperature transmitter 4-20 ma, temperature switch, flow switch, flow meter, particle counters. Various electric switches can be added to indicate the filter contamination level. Device Modification (upon request) different RAL paint colour up to corrosion-protection class C5 ISO 12944, motor equipment, different IP rating, different voltage, approvals from licensing institutions, special sizes with different dimensions, Modification for installation in altitudes over 1000 m and different ambient temperatures. Planning information Set-up The unit must be set up so the air supply and exhaust will not be obstructed. The clearance to air obstacles at the front and back of the cooler should be at least half the cooler height (dimension B). Ensure adequate ventilation. When installing the unit, be sure the warm exhaust air or noise emitted will not cause problems. If the ambient air is dirty, excess deposit on the cooling matrix must be expected. This will reduce the cooling capacity. In this case, particularly in the case of air loaded with oil mist, the air ducts must be cleaned regularly. For outdoor installation, ensure the motor is adequately protected from the weather. Ensure easy access for inspection and maintenance. Mounting The units secure to the mounting rails with four screws. Be sure the support structure is sized adequately. Install in any position. Connecting the oil circuit The connection between the system and the cooling matrix should be stress and vibration free, which can be achieved by using conduit. Follow the relevant safety regulations to prevent environmental damage due to potential oil leaks (e.g. collection pans). DE270001 03/2018 We reserve the right to amend specification. Bühler Technologies GmbH 3

Technical data Technical Data Materials / surface protection Cooling matrix: Ventilation box, safety guard and motor brackets: Pump: Colour: RAL 7001 : painted aluminium plastic-coated steel anodised aluminium, sintered steel aluminium die casting, passivated, unpainted Operating fluids: Mineral oils per DIN 51524 Gear oil per DIN 51517-3 Operating pressure, static: Suction pressure: Operating oil temperature: max. viscosity: Ambient temperature: -15 to +40 C max. altitude: 16/29/42 L/min max. 6 bar 58/87 L/min max. 8 bar max. -0.4 bar/-0.6 bar temporarily max. 80 C (higher upon request) 100 cst medium viscosity (higher upon request) 1000 m Filter series: Filtration Group PI 200 Visual contamination indicator switching point: Δ P 2.2 bar +/-10 % Filter bypass valve opening pressure: Δ P 3.5 bar +/-10% Available filter fineness: 3 100 µm Seals: Electric motors (others available upon request) Voltage/frequency: NBR 220/380V 230/400V 240/415V 50Hz 460 60 Hz Thermal stability: Insulation class F, utilisation per Class B IP rating: The motors comply with standard IEC 60034. Electric per NEMA, with UL/CSA/EAC approval. Model key Pump output per litre IP55, see section "Filter Elements" 57 58 99 mechanical contamination indicator (standard) electric top for contamination indicator NO contact/nc contact Contamination indicator with LED ring and 2 switching points VSA 24-SM FGSL 30 / PI 2015-57 / BNK 2.4-30-0.75kW-IBx / 7680358 / 99 see BNK data sheet no. 360001 Frame size Number of motor contacts Pump output per litre Motor power AB IB ITB ATB external bypass / x Bypass value 2 bar, 5 bar, 8 bar internal bypass / x Bypass value 2 bar, 5 bar, 8 bar internal temperature-dependent bypass 2 bar / 45 C external temperature-dependent bypass 2 bar / 45 C Filter element, see section "Filter Elements" Expansion and modification per section "Equipment Expansion" 4 Bühler Technologies GmbH We reserve the right to amend specification. DE270001 03/2018

Basic Data Standard Models (for 50 Hz frequency) The standard model includes the installed filter housing with mechanical contamination indicator, without filter element. Item no. Cooler model spec. cooling capacity kw/k 27004124IE3 FGSL 15/PI 2008-57/ BNK 2.4-15-0.75kW-IE3 27004086IE3 FGSL 30/PI 2015-57/ BNK 2.4-30-0.75kW-IE3 27004084IE3 FGSL 15/PI 2015-57/ BNK 3.4-15-0.75kW-IE3 27004083IE3 FGSL 30/PI 2015-57/ BNK 3.4-30-0.75kW-IE3 27004144IE3 FGSL 40/PI 2015-57/ BNK 3.4-40-1.1kW-IE3 27004088IE3 FGSL 30/PI 2015-57/ BNK 4.4-30-0.75kW-IE3 27004186IE3 FGSL 40/PI 2015-57/ BNK 4.4-40-1.1kW-IE3 27004085IE3 FGSL 60/PI 2030-57/ BNK 4.4-60-1.5kW-IE3 27004232IE3 FGSL 60/PI 2030-57/ BNK 5.4-60-2.2kW-IE3 27004187IE3 FGSL 90/PI 2045-57/ BNK 5.4-90-2.2kW-IE3 27004141IE3* FGSL 60/PI 2030-57/ BNK 6.4-60-3kW-IE3 27004192IE3* FGSL 90/PI 2045-57/ BNK 6.4-90-3kW-IE3 Cooling capacity at ETD = 40 K (kw) max. circulation rate (L/min) *Item numbers for 50 Hz version only. 60 Hz versions available upon request. **DIN EN ISO 3744, Class 3, when operated at 60 Hz +3 db Filter Accessories Item no. Description 77536550 Electric top for contamination indicator NO/NC contact Motor power Number of motor contacts Rated current at 400 V Weight (kg) Volume (L) 0.09 3.6 16 0.75 kw/4/1.62 A 42 1.3 66 0.13 5.2 29 0.75 kw/4/1.62 A 43 1.3 66 0.15 6 16 0.75 kw/4/1.62 A 52 1.8 71 0.24 9.6 29 0.75 kw/4/1.62 A 53 1.8 71 0.27 10.8 42 1.1 kw/4/2.35 A 56 1.8 71 0.34 13.6 29 0.75 kw/4/1.62 A 58 2.3 73 0.39 15.6 42 1.1 kw/4/2.35 A 61 2.3 73 0.40 16 58 1.5 kw/4/3.17 A 71 2.3 73 0.52 20.8 58 2.2 kw/4/4.56 A 75 3.1 79 0.58 23.2 87 2.2 kw/4/4.56 A 75 3.1 79 0.92 36.8 58 3 kw/4/6.15 A 112 4.1 86 1.05 42 87 3 kw/4/6.15 A 112 4.1 86 1320099 VSA 24-DM contamination indicator with LED ring and 2 switching points Filter elements PS fibreglass filters are suitable for low viscosity oils and have a high dirt capacity. DRG wire mesh filter elements DRG are suitable for high viscosity motor and gear oils and have a low dirt capacity. They are more expensive than type PS, but can be cleaned. PS fibreglass filter elements 3 µm 6 µm 10 µm 25 µm PI 2008 PI 2015 PI 2030 PI 2045 Type: PI 2108 PS 3 PI 5108 PS 6 PI 3108 PS 10 PI 4108 PS 25 Item no.: 7680143 7943517 7680341 7680457 Type: PI 2115 PS 3 PI 5115 PS 6 PI 3115 PS 10 PI 4115 PS 25 Item no.: 7680168 7955099 7680358 7680473 Type: PI 2130 PS 3 PI 5130 PS 6 PI 3130 PS 10 PI 4130 PS 25 Item no.: 7680176 7955107 7680366 7680481 Type: PI 2145 PS 3 PI 5145 PS 6 PI 3145 PS 10 PI 4145 PS 25 Item no.: 7680184 7955115 7680374 7680499 Sound pressure level db(a)** DE270001 03/2018 We reserve the right to amend specification. Bühler Technologies GmbH 5

DRG wire mesh filter elements 10 µm 25 µm 40 µm 60 µm 100 µm PI 2008 PI 2015 PI 2030 PI 2045 Calculation example and nomenclature t ÖE [ C] t LE [ C] ETD [K] P spez [kw / K] P [kw] Q [l/min] C Öl [kj/kgk] Type: PI 8108 DRG 10 PI 8208 DRG 25 PI 8308 DRG 40 PI 8408 DRG 60 PI 8508 DRG 100 Item no.: 7718737 7680929 7680978 7681018 7681075 Type: PI 8115 DRG 10 PI 8215 DRG 25 PI 8315 DRG 40 PI 8415 DRG 60 PI 8515 DRG 100 Item no.: 7711120 7680945 7680994 7681034 7681083 Type: PI 8130 DRG 10 PI 8230 DRG 25 PI 8330 DRG 40 PI 8430 DRG 60 PI 8530 DRG 100 Item no.: 7718810 7680952 7718802 7681042 7689078 Type: PI 8145 DRG 10 PI 8245 DRG 25 PI 8345 DRG 40 PI 8445 DRG 60 PI 8545 DRG 100 Item no.: 7711179 7711187 7681000 76841059 7689094 Inlet oil temperature Inlet air temperature Temperature differential: ETD = t ÖE - t LE specific cooling performance (see performance curves): P spez = P / ETD Cooling performance in kw Oil flow rate ς [kg/dm ³ ] Gravity of oil 0.9 kg/dm ³ Calculation example Assumptions: Tank capacity (V) approx. 200 L Start up temperature of oil (T 1 ) 15 C ( 288 K) Oil heats up in approx. t = 25 min. (1500 s) to (T 2 ) 45 C ( 318 K) Required oil temperature (t ÖE ) 60 C Inlet air temperature (t LE ) 30 C Calculation: 1. Calculating P from the tank warming Specific heat capacity of the oil (approx. 2.0 kj / kgk) P V. ς. c Oil. 200 l. kg 0.9. kj 2. (T 2 - T 1) l kg. (318 K - 288 K) K = t = = 7.2 kw 1500 s 2. ETD = t ÖE - t LE = 60 C - 30 C = 30 K 3. Determining the cooler size: P spez = P / ETD = 7.2 kw / 30 K = 0.24 kw/k 4. Select a cooler from the basic data with P spez 0.24 kw/k. There is one option: BNK 3.4 with 30 L pump 6 Bühler Technologies GmbH We reserve the right to amend specification. DE270001 03/2018

Dimensions (mm) View A Item no. Cooler model A B C D E F G H J (Oil ON) 27004124IE3 FGSL 15/PI 2008-57/ BNK 2.4-15-0.75kW-IE3 27004086IE3 FGSL 30/PI 2015-57/ BNK 2.4-30-0.75kW-IE3 27004084IE3 FGSL 15/PI 2015-57/ BNK 3.4-15-0.75kW-IE3 27004083IE3 FGSL 30/PI 2015-57/ BNK 3.4-30-0.75kW-IE3 27004144IE3 FGSL 40/PI 2015-57/ BNK 3.4-40-1.1kW-IE3 27004088IE3 FGSL 30/PI 2015-57/ BNK 4.4-30-0.75kW-IE3 27004186IE3 FGSL 40/PI 2015-57/ BNK 4.4-40-1.1kW-IE3 27004085IE3 FGSL 60/PI 2030-57/ BNK 4.4-60-1.5kW-IE3 27004232IE3 FGSL 60/PI 2030-57/ BNK 5.4-60-2.2kW-IE3 27004187IE3 FGSL 90/PI 2045-57/ BNK 5.4-90-2.2kW-IE3 27004141IE3 FGSL 60/PI 2030-57/ BNK 6.4-60-3kW-IE3 27004192IE3 FGSL 90/PI 2045-57/ BNK 6.4-90-3kW-IE3 K (Oil OFF) L M N O 370 370 203 83.5 476 106 25 70 G1 1/4" G1" 125 118 30 212 370 370 203 83.5 474 106 25 70 G1 1/4" G1" 125 188 30 212 440 440 203 118.5 501 105 25 70 G1 1/4" G1" 150 156 30 247 440 440 203 118.5 499 105 25 70 G1 1/4" G1" 150 156 30 247 440 440 203 118.5 516 105 25 70 G1 1/4" G1" 150 156 30 247 500 500 203 148.5 524 104 25 70 G1 1/4" G1" 175 148 30 277 500 500 203 148.5 542 104 25 70 G1 1/4" G1" 175 148 30 277 500 500 203 148.5 610 104 25 73 G1 1/2" G1" 175 148 30 277 580 580 356 112 678 100 23.5 73 G1 1/2" G1" 200 153 30 317 580 580 356 112 713 100 23.5 73 G1 1/2" G1" 200 153 53.5 317 700 700 356 172 737 110 9.5 73 G1 1/2" G1 1/4" 225 151 30 377 700 700 356 172 772 110 9.5 73 G1 1/2" G1 1/4" 225 151 53.5 377 DE270001 03/2018 We reserve the right to amend specification. Bühler Technologies GmbH 7

Functional diagram Standard version BNK 2 Standard version BNK 3 to BNK 6 The oil inlet is on the left of the cooling matrix. The oil outlet is always on the opposite side. The oil inlet is on the bottom left of the cooling matrix. The second connection at the top must be closed. The oil outlet is always on the opposite side. Internal bypass IB/ ITB (BNK 3-6) External bypass AB/ATB (BNK 2-6) The oil inlet and outlet is always on the same side of the cooling matrix. The connection on the opposite side must be closed. The oil inlet is always at the bottom left of the cooling matrix. The second connection must be closed. The oil outlet is always on the opposite side. With bypass valve With temperature-dependent bypass valve 8 Bühler Technologies GmbH We reserve the right to amend specification. DE270001 03/2018