www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage

Similar documents
Power Break II Switchboard

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

Critical Power Switchboards. Selection and Application Guide

A. Submit manufacturer's literature and technical data before starting work.

ATLV MaxSG. Low Voltage Metal Enclosed Switchgear

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

Design Standard. Purpose: Design Standard:

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Power delivery for industrial facilities

WL Low Voltage Metal-Enclosed Switchgear

WL Low Voltage Metal-Enclosed Switchgear. Selection and Application Guide.

GE 8000-Line Motor Control Centers

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

Medium Voltage Metal-Enclosed Switches

Medium Voltage Equipment 5-15 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General

C1000 Series Automatic Cap Bank

Medium Voltage Metal-Enclosed Switches

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

SIMOVAC and SIMOVAC-AR. Medium-voltage controllers 2.3 kv kv. usa.siemens.com/simovac

University of Houston Master Construction Specifications Insert Project Name

SECTION LOW VOLTAGE MOTOR CONTROL CENTERS LINE WITH POWER MANAGEMENT. A. Low Voltage Motor Control Center with Power Management

Mar H: SUPPLEMENTAL PARALLELING GEAR (16315-H)

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

SafeGear TM Motor Control Center Arc resistant metal-clad construction

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

SWITCHGEAR DIVISION PRODUCT PROFILES

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

A. This section includes unit capacitors for power factor correction.

POWER-ZONE 4 Low Voltage Metal-Enclosed Drawout Switchgear with MASTERPACT NW Low Voltage Power Circuit Breakers

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

MaxSG Low Voltage Switchgear

University of Houston Master Construction Specifications Insert Project Name

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

Section 18. Medium Voltage Equipment. BuyLog Catalog 18-1

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

POWERCON CORPORATION

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

GE 8000-Line Motor Control Centers Mains, Feeders, Incoming Lines C-1

6/4/2017. Advances in technology to address safety. Thomas A. Domitrovich, P.E., LEED AP VP, Technical Sales Eaton

A. This section includes enclosed dry type transformers for lighting and power loads, with primaries and secondaries rated 600 volts and less.

Power/Vac OEM Express Switchgear

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

Basics of Medium Voltage Motor Control Starter Power Components & Starter Types

Selection and application guide

Tradition. Technology. Innovation.

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

16.13 Unit Substation to 15kV Construction Standards Page 1 of 7

Descriptive bulletin. ReliaGear ND ANSI narrow frame metal-clad switchgear

SIGNAL WORDS QUALIFIED PERSON

Zone Selective Interlock Module. For GE Circuit Breakers

Design Considerations to Enhance Safety and Reliability for Service Entrance Switchboards

GE Consumer & Industrial Electrical Distribution. Power Break II. Insulated Case Circuit Breakers

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

Specification Guide. for RMAX. Direct Replacement. AC Low Voltage. Power Circuit Breakers

A comparison of metal-enclosed load interrupter (ME) switchgear and metal-clad (MC) switchgear

Advance 27 ANSI 27 kv switchgear

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin

Model 6 Motor Control Centers Catalog 8998CT9701R07/ Class 8998

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

MV Metalclad Switchgear 4760V-15000V 20KA-63KA. AC Power Circuit Breaker Rating Structure. Test Procedures for Power Circuit Breakers

MOLDED CASE CIRCUIT BREAKER BASICS. David Castor, P.E.

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

MESG 12 / 17.5 / 24 / 36 KV

7. SERVICES OVER 600 VOLTS

GE Industrial Solutions. DEH Installation and Maintenance Manual AKD-20 AR / Entellisys AR Exhaust Plenum System

MEDIUM VOLTAGE AIS ANSI SWITCHGEAR Advance and Advance 27. Non-arc-resistant MV ANSI switchgear

Medium Voltage Equipment. Section 15.

4-Day Power System Analysis, Coordination, System Studies

SECTION LOW VOLTAGE SWITCHBOARDS - Spectra Bolt-On

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

AKD-20 Low-voltage Switchgear

BGE STRATEGIC CUSTOMER ENGINEERING

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

SECTION SWITCHGEAR. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

Quik-Spec Coordination Panelboard Specifications

BUSWAY Low Voltage (Pow-R-Flex)

Grounding Systems. Resistance. Resistance Grounding Systems Contents

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES

Solar Power Switchgear & Energy Storage Renewable Energy Systems

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

Transcription:

Switchgear Low Voltage Introduction...13-1 AKD-10 Low-Voltage Switchgear...13-3 AKD-20 Low-Voltage Switchgear...13-3 Low Voltage Switchgear GE low-voltage switchgear is heavy-duty equipment built to ANSI Standards. GE switchgear is designed to have more margin within its ratings and to provide maximum continuity of service for those applications subject to severe duty such as repetitive switching encountered with motor starting, power factor correction, demand control, and load shedding, etc. A major factor contributing to this extended continuity of service is the availability of renewal parts complete with detailed maintenance instructions and original equipment documentation. From a coordination standpoint, Air circuit breakers can provide full selectivity with each other and with other protective devices. The bus is thermally rated; i.e. based upon temperature rise, as opposed to switchboards where the bus may be sized on a current density basis. Switchgear also houses instrumentation and other auxiliary circuit protective devices. It is available in single or multiple source configurations and applied as a power distribution unit or as part of a unit substation in indoor or outdoor construction. Rev. 1/08 Publications and Reference: See Section 22 for a complete list of additional product-related publications www.geelectrical.com Section 13 Key Switchgear Features Full tin-plated copper bus Optional insulated/isolated bus bar system protects against accidental contact by people or foreign objects and inhibits the spread of any arcing faults. Breaker compartment doors without ventilating slots True closed-door draw-out added protection for operator Instrument panel for breaker control circuitry permits several maintenance functions without subjecting operators to energized primary circuits of an open breaker compartment door Optional shutters over primary disconnects provides personnel protection from energized disconnects Modular construction for greater installation flexibility 13-1

Switchgear Low Voltage Section 13 CSI Specifications Low Voltage Metal Enclosed 16400 Low Voltage Switchgear 26 23 00 Low Voltage Switchgear Low Voltage Switchgear One-Line 13-2 Ground Fault Detectors Motor Control Centers and Drives Medium Voltage Luminaires and Lamps GF M Switchgear and Switchboards Busway Reactor VFD M M M M Motors Lighting Controls Ballasts Secondary Substation Transformers Power Meters 1 FVNR 2 FVNR 4 FVNR TVSS Circuit Breakers High Pressure Contact Switches Capacitors and Harmonics Filters Voltage Regulators Paralleling Switchgear Automatic Transfer Switch M Network Design and Equipment Loadcenters and Metering Modules Ethernet Hub Δ Y UPS Distribution Transformers Panelboards and Lighting Panels Safety Switches Power Monitoring Software G G www.geelectrical.com Rev. 1/08

Switchgear Low Voltage AKD-10 and AKD-20 For pricing and application assistance, contact your local GE sales office. GE type AKD-10 low-voltage switchgear consists of WavePro power circuit breakers combined with the field-proven switchgear design features needed to meet today s exacting requirements for safety, reliability, maintainability, flexibility, convenience, economy and continuity of service. Integral to the WavePro low-voltage power circuit breaker is the Power+, enhanced MicroVersaTrip Plus or MicroVersaTrip PM solid-state, digital trip unit. The optional POWER LEADER Power Management System is available for applications requiring a completely integrated system including overcurrent protection, protective relaying and system monitoring. AKD-10 switchgear and WavePro circuit breakers meet or exceed industry standards including UL 1066 and 1558; CSA C22.2; NEMA SG-3 and SG-5; ANSI-C37.13 and C37.20.1. WavePro and EntelliGuard Low Voltage Power Circuit Breakers Time proven for trouble free performance Five cycle stored energy closing 6 frame sizes 800-5000 amps for application flexibility Interrupting ratings: 30kA-200kA Fully maintainable to assure operational readiness MicroVersaTrip solid-state protection trip unit with LCD increased flexibility and accuracy with true rms sensing for standard (s) and optional (o) time-current adjustments: Adjustable current setting (s) Adjustable long-time delay (s) Phase selectable digital rms ammeter (s) Adjustable instantaneous pick-up (s) Adjustable ground fault pick-up and adjustable ground fault delay with selectable I 2 t curve (o) Adjustable short-time pick-up and adjustable short-time delay with selectable I 2 t curve (o) Zone selective interlocking for improved selectivity on both short-time and ground-fault or ground-fault only (o) Defeatable GF (o) Switchable INST/ST and GF (o) Integrally fused breakers for high fault-current applications Rating plugs for added flexibility Power+ Trip unit with true rms sensing and rotary selection of pick-up and delay settings: Adjustable long-time pick-up and delay (s) Adjustable instantaneous pick-up (s) Adjustable short-time pick-up and delay with I 2 t in or out (o) Adjustable ground fault pick-up and delay with l 2 t in or out (o) Defeatable ground fault (o) Target module with LED trip indicators (o) Ground fault function contained within the rating plug Rev. 1/08 Publications and Reference: See Section 22 for a complete list of additional product-related publications www.geelectrical.com POWER LEADER Power Management System Section 13 A MicroVersaTrip PM trip unit on each breaker for overload, short-circuit and ground fault protection, with true rms sensing and an LCD for local metering. Trip unit mounted in the breaker escutcheon, providing convenient out front trip unit information on the LCD. A Modbus Monitor mounted on the switchgear with a display screen and keypad to display power systems data. A shielded, twisted pair communication bus that carries information between the POWER LEADER Monitor and breakers. A port for remote communication. All information can be transmitted to a host computer for metering, energy monitoring, load analysis and other functions using POWER LEADER Power Management Control System software. AKD-20 Low-Voltage Switchgear For Release 4Q 2008 For pricing and application assistance, contact your local GE sales office. GE type AKD-20 low-voltage switchgear consists of EntelliGuard G power circuit breakers and state-of-the art EntelliGuard TU digital trip unit that together provide enhanced protection, endurance and safety. The key features of the AKD-20 are the tried and true construction of the AKD family heritage, common transitions to older versions of AKD equipment, true closed door racking with remote racking devices, non vented circuit breaker panels, insulated and isolated bus construction and more. The product is fully rated to UL 1066 and 1558; CSA C22.2; NEMA SG-3 and SG-5; ANSI C37.13 and C37.20.1; Seismic ratings to IBC-2003 and IEEE-693-1997. Instructions/Maintenance Low Voltage Switchgear AKD-10 Application Guide WAVEPRO Low Voltage Power Circuit Breaker Application Guide User Publication Summary DET-196 DET-167 DEE-194 13-3

Switchgear Low Voltage Section 13 NOTES: 13-4 www.geelectrical.com Rev. 1/08

Entellisys 4.0 Low-Voltage Switchgear Entellisys 4.0 is the sensible choice to save you money over the lifetime of your system. Entellisys Low-Voltage Switchgear is the first system to provide the power of knowledge about the entire switchgear lineup. This power can be used: by the engineer to improve protection, by the installing contractor to shorten installation time, by the operator to stay out of the arc flash zone, by the maintenance personnel to save maintenance time and money, and by the owner to adapt the equipment to the dynamic needs of the facility. Entellisys helps to reduce costs, shorten schedules, and increase reliability throughout the process of designing, installing, maintaining, and owning your low-voltage power distribution switchgear. Rev. 1/08 Publications and Reference: See Section 22 for a complete list of additional product-related publications www.geelectrical.com Section 14 Entellisys is becoming the preferred solution in critical applications such as data centers, hospitals, petro/chem facilities and airports around the world. State-of-the-art protection, monitoring and control make it the intelligent choice to provide reliable power distribution now and in the future. Contact your account manager and request a financial savings report, customized for your application. Layout and sizing...14-2 14-1

Entellisys 4.0 Low-Voltage Switchgear Layout and Sizing Entellisys indoor low voltage switchgear height is 92" (97" over the top wiring trough and 103.5" over the optional breaker hoist). The available breaker stacking space is 84". Breaker frame size and type determine the width of the breaker sections and also the minimum depth of the switchgear line-up. Refer to tables below for properly sizing Entellisys line-ups. The depth of the entire line-up is determined by the deepest device in the line-up. For example, a line-up with an EGF-20 breaker with a fuse roll-out (depth 60") and EGF-08 breakers (depth 67") would be a minimum of 67" deep the EGF-08 being the deepest device. Also refer to the section arrangements on the following pages for available breaker stacking configurations. Switchgear Layout Considerations 1. Sections can be bussed together if there are matching bus levels in the adjacent sections. Refer to the sample Entellisys line-up. 2. Any breaker compartment shown on the section drawings can be made blank to provide additional space for mounting Entellisys devices. 3. The ampere ratings shown beside each breaker symbol indicate the range of frame sizes that are allowed in the particular section arrangement. This takes into consideration the temperature rise in the section due to breaker loading. Refer to ANSI C37.20.1-2002 para 8.4.2.3 for cumulative circuit breaker loading guidelines. 4. Devices cannot be mounted on breaker cubicle doors. 5. 3200A, 4000A, and 5000A fuse roll-outs are the same size as their respective breakers, therefore any compartment shown with a 3200, 4000, or 5000 amp breaker will also accommodate a fuse roll-out and vice versa. 14-2 www.geelectrical.com Rev. 1/08 Section 14 6. Front busway connections to a circuit breaker require a blank compartment above the breaker for busway above or a blank compartment below the breaker for busway below. 7. Use of fused breakers does not necessarily require 200kA bus bracing. Bus bracing should be based on the available short circuit current on the switchgear bus. 8. 200kA bus bracing can limit feeder breaker placement. 200kA bus bracing does not allow adjacent 22 inch wide sections. 9. Factory review of layout is required for bus bracing greater than 100kA 10. Some cable entrance designs are not suitable for service entrance. Consult the factory if service entrance is required for the incoming cable section. 11. Additional cable and conduit space is available by making breaker sections wider (22 inch wide to 30 inch wide or 30 inch wide to 38 inch wide) or by making the line-up deeper (7 or 14 inches). Refer to the tables below. Indoor Enclosure Depth Options Available Depth Options Front compartment 30" 37" Rear compartment (Std depth or 7" or 14" rear extension) 30" (std) 37" (7" ext) 44" (14" ext) 30" (std) 37" (7" ext) 44" (14" ext) Total depth 60" 67" 74" 67" 74" 81" Breaker Device Combination Frame Size Breaker Cubicle Minimum Section Minimum Equipment Depth Optional Equipment Type or Bus Rating (Amperes) Vertical Height (Inches) Width 3 (Inches) [Front/Rear Compt] (Inches) Depth (Inches) EGS-08 800 21 22 60 [30/30] 67/74 EGH-08 800 21 22 60 [30/30] 67/74 EGX-08 800 21 22 60 [30/30] 67/74 EGF-08 800 21 22 67 [37/30] 74/81** EGS-16 1600 21 22 60 [30/30] 67/74 EGH-16 1600 21 22 60 [30/30] 67/74 EGF-16 1600 21 22 67 [37/30] 74/81** EGS-20 2000 21 22 60 [30/30] 67/74 EGF-20 with fuse roll-out 2000 56 30 60 [30/30] 67/74/81 2 EGS-32 3200 35 30 60 [30/30] 67/74/81 2 EGH-32 3200 35 30 60 [30/30] 67/74/81 2 EGX-32 3200 35 30 60 [30/30] 67/74/81 2 EGF-32 with fuse roll-out 3200 84 38 67 [37/30] 74/81** EGS-40 4000 35 30 60 [30/30] 67/74/81 2 EGX-40 4000 35 30 60 [30/30] 67/74/81 2 EGF-40 with fuse roll-out 4000 84 38 67 [37/30] 74/81** EGS-50 5000 35 38 74 [37/37] 81** EGX-50 5000 35 38 74 [37/37] 81** EGF-50 with fuse roll-out 1 5000 35 38 74 [37/37] 81** 1600-4000A main bus rating 60 [30/30] 67/74/81 2 5000A main bus rating 67 [30/37] 74/81 2 1 Breaker and fuse roll-out must be mounted in separate vertical sections. 2 81" depth available only when these devices are used in a line-up with items identified with **. 3 Section width can be increased for additional cable / conduit space. 22" sections can be increased to 30" wide, 30" wide sections can be increased to 38" wide.