Standard Grade Power Module

Similar documents
XQ2000 SOUND ATTENUATED POWER MODULE

Caterpillar 1500kW XQ1500

Dual XQ350 Rental Package

CMEC POWER GENERATION. PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET WHERE THE WORLD TURNS FOR POWER FEATURES

STANDBY 650 ekw 812 kva 60 Hz 1800 rpm 480 Volts

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 415 Volts

X Q I P P. POWER MODULE PRIME 1825 kw CONTINUOUS 1640 kw 60 Hz Optimized. With DEIF CONTROLLER FEATURES

STANDBY 720 ekw 900 kva 50 Hz 1500 rpm 400 Volts

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

STANDBY 240 ekw 300 kva 50 Hz 1500 rpm 400 Volts

PRIME 365 ekw 456 kva 60 Hz 1800 rpm 480 Volts

STANDBY 250 ekw 313 kva 60 Hz 1800 rpm 208 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1500 ekw 1875 kva 50 Hz 1500 rpm 400 Volts

PRIME 508 ekw 635 kva 50 Hz 1500 rpm 400 Volts

STANDBY 600 ekw 750 kva 50 Hz 1500 rpm 400 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

RENTAL XQ400 SOUND ATTENUATED. 50/60 Hz FEATURES

XQC1600 Power Module POWER MODULE. 50/60Hz Switchable Rating FEATURES REDUCED ENVIRONMENTAL IMPACT SINGLE SOURCE SUPPLIER SOUND-ATTENUATED ENCLOSURE

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

X Q R E N T A L

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 415 Volts

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 4160 Volts

DIESEL GENERATOR SET FEATURES

STANDBY 2480 ekw 3100 kva 50 Hz 1500 rpm 400 Volts

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

XQ2000 SOUND ATTENUATED POWER MODULE

PRIME 920 ekw 1150 kva 50 Hz 1500 rpm 400 Volts

PRIME. 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

X Q R E N T A L

STANDBY 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts

X Q R E N T A L

STANDBY 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME 808 ekw 1010 kva 50 Hz 1500 rpm 415 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME 2260 ekw 2825 kva 50 Hz 1500 rpm Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 415 Volts

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

UTILITY POWER MODULE DUAL VOLTAGE DUAL FREQUENCY SOUND ATTENUATED 400 V, 50 Hz, 2000 KVA (1600 EKW) 480 V, 60 Hz, 1825 EKW

PRIME 591 ekw 739 kva 60 Hz 1800 rpm 480 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

CONTINUOUS 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 880 ekw 1100 kva 50 Hz 1500 rpm 400 Volts

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

MISSION CRITICAL STANDBY. 50 Hz 1500 rpm Volts DIESEL GENERATOR SET FEATURES

STANDBY 200 ekw 250 kva

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 600 Volts

PRIME 725 ekw 906 kva 60 Hz 1800 rpm 480 Volts

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

CONTINUOUS 1250 KW POWER MODULE

PRO Rental Product Range. PRO275-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

PRO Rental Product Range. PRO100-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

PRIME 1360 ekw 1700 kva 50 Hz 1500 rpm 400 Volts

Standby 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

DIESEL FEATURES GENERATOR SET

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

STANDBY 200 ekw 250 kva

C13. STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

C18. STANDBY 560 ekw 700 kva 50 Hz 1500 rpm 400 Volts

1000 kva POWER MODULE UTILITY SWITCHGEAR C32 ACERT TECHNOLOGY 50 / 60 Hz CONVERTIBLE SOUND ATTENUATED ISO 20 FT. CSC CERTIFIED

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 440 Volts

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

STANDBY 600 ekw 750 kva 60 Hz 1800 rpm 220 Volts

TECHNICAL OFFER. 1. CATERPILLAR PACKAGE OVERHAULED GENSET TYPE: C175-16, 2725KVA Prime Power, Build 2007, Original, Serial Number WYB00115, SMU 9725

Standby 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 400 Volts

60 Hz FEATURES. Exclusively from your Caterpillar dealer

MISSION CRITICAL 800 ekw 1000kVA 60 Hz 1800 rpm 480Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

Mission Critical Standby 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 80 ekw 100 kva PRIME 72 ekw 90 kva

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

Standby kw (kva) 480V 60 Hz Rating

PRO Rental Product Range. PRO60-2 (R96 EUIIIa Equivalent) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR)

STANDBY 300 ekw 375 kva 60 Hz 1800 rpm 480 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm Volts

STANDBY 350 ekw kva 60 Hz 1800 rpm 480 Volts

STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

P R I M E e k W k V A 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

CONTINUOUS 1230 ekw 1538 kva 60 Hz 1800 rpm 480 Volts

CONTINUOUS 728 ekw 910 kva 50 Hz 1500 rpm 400 Volts

XQ 200 R E N T A L. STANDBY 200 kw PRIME 182 kw. POWER MODULE 60Hz 1800 rpm 480V FEATURES

Specifications. Cat XQP150 Rental Generator Set. Prime 120 kw, 150 kva 50/60 Hz Switchable EU Stage IIIA. Prime kw (kva)

PRIME 292 ekw 365 kva 50 Hz 1500 rpm 400 Volts

Rating Definitions and Conditions

PRIME 225 ekw 281 kva

STANDBY 300 ekw 375 kva 60 Hz 1800 rpm 480 Volts

Standby kw Prime kw

STANDBY 700 ekw 875 kva 60 Hz 1800 rpm 600 Volts

MISSION CRITICAL STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

Transcription:

Standard Grade Power Module Using Cat Diesel Engine Generator Sets FEATURES CAT DIESEL GENERATOR SETS Factory designed, certified prototype tested with torsional analysis. Production tested and delivered to you in a package that is ready to be connected to your fuel and power lines. EPG Designer computer sizing available. Supported 100% by your Caterpillar dealer with warranty on parts and labor. Extended warranty available in some areas. The generator set was designed and manufactured in an ISO 9001 compliant facility. Generator set and components meet or exceed the following specifications: AS1359, AS2789, ABGSM TM3, BS4999, DIN6271, DIN6280, EGSA101P, JEM1359, IEC 34/1, ISO3046/1, ISO8528, NEMA MG1-22. CATERPILLAR SR4B GENERATOR Single bearing, wye connected, static regulated, brushless permanent magnet excited generator designed to match the performance and output characteristics of the Caterpillar diesel engine that drives it. RELIABLE, FUEL EFFICIENT DIESEL The compact, four-stroke-cycle diesel engine combines durability with minimum weight while providing dependability and economy. The fuel system operates on a variety of fuels. CATERPILLAR COOLING SYSTEM Sized compatible to rating with energy efficient fan and core. CATERPILLAR SWITCHGEAR Single unit or optional paralleling components. Circuit breakers, bus bars, and connection panel ready to connect. EXCLUSIVE CATERPILLAR VOLTAGE REGULATOR Three-phase sensing and 1:1 or 2:1 Voltsper-Hertz regulation give precise control, excellent block loading, and constant voltage in the normal operating range. ISO CONTAINER For ease of transportation and protection. Meets ISO/TC104 and ANSI/MH5.1.

STANDARD EQUIPMENT Engine Air cleaner, with service indicator Batteries Battery charger, heavy duty Charging alternator Filters; fuel, LH with service indicators; lubricating oil Fuel-water separator system Insulated muffler PSG governor, installed on 3412 Pump, fuel priming Radiator Service meter Standard jacket water heaters Sump pump 2301A governor installed on 3500s load share in switchgear Generator SR4B brushless, 480 volt, PM excited three-phase with voltage regulator, space heater Container Air intake louvers Bus bar access door Fuel tank w/gauge Steel deck floor galvanized 24 VDC lighting Switchgear Automatic start/stop with cycle cranking and cooldown timer Auxiliary power connections for jacket water heater, battery charger, space heaters Battery charger, heavy duty 20A Circuit breaker, manually operated Connection terminals, 3-phase and neutral Synch lights and reverse power relay 20-foot module, EMCP II generator mounted 40-foot module, floor standing with EMCP II components OPTIONAL EQUIPMENT Container Cold weather packages Custom decals Larger fuel tanks Motorized louvers Sound attenuation 72 dba at 50 feet 85 dba at 50 feet Undercarriage OPTIONAL EQUIPMENT (Continued) Generator Digital voltage regulator 2:1 volts per hertz VR3 Optional voltages 600-4160 Mil Std 461B, VDE 875 Level N Temperature rise detectors Switchgear (40 ft) CIM, CCM, remote annunciation Circuit breaker, electrically operated Meters: power factor, KVAR, WM, W/WHM, synchroscope Paralleling: semiautomatic or fully automatic Protective Relays: 27, 59, 40, 46, 810, 81 V Engine Fuel transfer system Oil fired jacket water heaters Oil level makeup system Special radiators for high or low ambients CATERPILLAR 3412 Engine V-12, Four-Stroke-Cycle Diesel Bore mm (in)... 137 (5.4) Stroke mm (in)... 152 (6.0) Displacement L (cu in)...27.0 (1649) Aspiration...Turbocharged-Aftercooled CATERPILLAR 3508, 3512 and 3516 ENGINES V-8, V-12, & V-16, Four-Stroke-Cycle Diesel Bore mm (in)... 170 (6.7) Stroke mm (in)... 190 (7.5) Displacement L (cu in)..v-8...34.5 (2105) V-12...51.8 (3158) V-16...69.0 (4210) Aspiration...Turbocharged-Aftercooled CATERPILLAR SR4B GENERATOR Type...Static regulated brushless PM excited Construction... Single bearing, close coupled Three phase... Wye connected 6 lead Insulation...Class H 2 extra dips and bakes on random wound units Enclosure...Drip proof Alignment...Pilot shaft Overspeed capability...130% Voltage regulator...3-phase sensing with Volts-per-Hertz Voltage regulation...less than ± 1% Voltage gain...adjustable to compensate for engine speed droop and line loss Wave form... Less than 5% deviation TIF...Less than 50 THF...Less than 3%

TECHNICAL DATA Prime +10% 60 Hz 600 EkW 900 EkW 900 EkW 1250 EkW 1750 EkW 2000 EkW Rating Information 50 Hz 520 EkW 800 EkW 800 EkW 1120 EkW 1600 EkW 1800 EkW 50 Hz 650 kv A 1000 kv A 1400 kv A 2000 kv A 2000 kv A 2250 kv A Engine and Engine Model 3412 3508 3508 3512 3516 3516 Container Container size 20 ft 20 ft 40 ft 40 ft 40 ft 40 ft Information Container dimensions* A A C C C C Fuel Capacity 660 gal (2500 L) 25 16.4 Hours of Standard 20 ft operation at 60% 1250 gal (4732 L) 31 23 17 15 load factor** Standard 40 ft 2500 gal (9464 L) 62 46 33 30 Optional 40 ft Approximate Including kg 9750 13 400 17 250 19 250 22 000 24 040 Weight (Dry) Container Ib 21 500 29 500 38 000 42 500 48 500 53 000 Container with Generator Set With kg 12 250 15 900 20 000 22 000 25 700 27 670 and Switchgear Undercarriage Ib 27 000 35 000 44 000 48 500 56 500 61 000 Rear Axle With kg 8850 11 800 12 700 14 300 19 300 18 600 Shipping Weight Undercarriage Ib 19 500 26 000 28 000 31 500 42 500 41 000 **Maximum standby rating at 1800 rpm W *Container Dimensions A 20 ft STD CAP L 610 cm (240 in) W 244 cm (96 in) H 1 259 cm (102 in) 381 cm (150 in) H 2 L H1 H2 L W H 1 H 2 C 40 ft HI CAP 1219 cm (480 in) 244 cm (96 in) 290 cm (114 in) 411 cm (162 in) NOTE: The container meets or exceeds the following standards and regulations. ISO/TC 104 Requirements for Cargo Containers ANSI/MH5.1 Basic Requirements for Cargo Containers ANSI/MH5.1.1 Requirements for Closed Van Containers The power module must have support under the center when set on the ground. The 3516 requires tri-axle chassis or options in price list. Maximum allowable weight (rear axles) on interstate highways is 34 000 lb for a two-axle chassis and 43 500 lb for three-axle chassis. Typically, a 3516 Power Module has a rear axle weight of 42 500 lb. An empty two-axle chassis weighs 6000 lb (gross) and a three-axle chassis weighs 8200 lb (gross).

STANDARD CONTROLS 12 m (40 ft) containers 480 V/60 Hz, 400 V/50 Hz) Floorstanding switchgear includes the following functions and features: Electronic Modular Control Panel (EMCP II) Components Generator Set Control (GSC) Monitoring Sequentially rotating, backlit LCD display of engine hours, engine rpm, DC battery voltage, oil pressure, and water temperature. Includes pushbutton to hold display on any single parameter. Protection Shutdowns: Overspeed, overcrank, high water temperature, low oil pressure, and emergency stop. With LED indicator for each condition. Alarms: Low coolant level AC Metering Three-phase volts (L-L), amperes and frequency with phase select pushbutton, on backlit LCD. Metering accuracy is 0.5%. Control Automatic starting with field adjustable cycle crank, failure to start (overcrank), and cooldown timer. Programming and Diagnostics Includes field programmable set-points for engine control and monitoring variables and self diagnosis of EMCP II system component and wiring failures. Alarm Module Flashing LED warnings for: low coolant temperature, high coolant temperature (pre-alarm), low oil pressure (pre-alarm), engine control switch not in automatic, and low DC voltage. Includes alarm horn and acknowledge pushbutton. Engine Control Switch Snap action rotary switch, four-position off/reset, automatic, manual, stop/cooldown. Off/reset for engine shutdown and resetting faults, automatic remote starting by customer contact closure, manual for local starting and manual paralleling, stop/cooldown for manual operation cooldown. Alarm Acknowledge/Lamp Test Switch Three-position, spring return to center switch for alarm acknowledge and lamp test of all discrete indicating lamps. Lamp test shall also sound the alarm horn. Annunciation Circuits Upon receipt of an alarm or shutdown condition, the horn shall sound and an LED shall flash. Upon acknowledgement from alarm acknowledge/lamp test switch, the horn shall be silenced and the lamp steadied. LED shall be extinguished when ECS is placed in the off/reset position if the alarm condition has been corrected. Circuits are recurring such that the LED shall flash and the horn sound, should another fault occur even prior to correction of the initial fault. Emergency Stop Pushbutton Mushroom head, twist to reset, causes engine shutdown and tripping of the generator circuit breaker. Prevents engine starting when depressed. Manual Paralleling Controls consisting of reverse power relay, synchronizing lights, and switch. Reverse power condition causes tripping of the generator circuit breaker, immediate engine shutdown, flashing of indicating lamp, and sounding of alarm horn. Circuit Breaker Fix mounted, three-pole, manually operated, molded case circuit breaker with solid state trip unit for overload (time overcurrent) and fault (instantaneous) protection. Includes DC shunt trip coil activated on any generator set monitored fault. Circuit breaker is sized for full load capacity of the generator set at 0.8 power factor. Load Share Governor Electronic load sharing governor with speed adjust potentiometer, idle/rated switch, and isochronous/droop switch.

STANDARD CONTROLS (Continued) Voltage Regulator Standard Caterpillar generator-mounted VR3 voltage regulator with voltage adjust rheostat mounted in the floorstanding switchgear. Current Transformers (3) Five-ampere secondary with shorting terminal strips Potential Transformers (3) 120VAC secondary with primary and secondary fuse protection, two connected to the generator side of the circuit breaker, one connected to the load side of the circuit breaker. Bus Bars Three-phase plus fully rated neutral bus bars with NEMA standard hole pattern for connection of customer load cables and generator cables. Bus bars are sized for full load capacity of the generator set at 0.8 power factor. Also includes ground bus, connected to the generator frame ground and container frame with holes for connection of field ground cable. Bus bars are accessible from outside of the power module via hinged, lockable cable access door. Accessory Power 3500 Power Modules Three 120VAC (60 Hz units) or 230VAC (50 Hz units) shore power connections for jacket water heaters, generator space heater, and battery charger. Battery Charger 24VDC/20A battery charger with float/ equalize modes and charging ammeter. 4160V or 3300V Power Modules Similar to 480 V and 400 V units except for the following: All bus bars are silver plated copper Generator circuit breaker, 3-pole, vacuum type, manually operated with 24VDC shunt trip. Sized for generator voltage and current ratings. Includes draw-out overcurrent relay, with instantaneous setting, ANSI device 50/51. 6 m (20 ft) containers 480 V/60 Hz, 400 V/50 Hz) Standard generator mounted Electronic Modular Control Panel II (EMCP II) with the following features: Electronic Modular Control Panel (EMCP II) Components Generator Set Control (GSC) Monitoring Sequentially rotating, backlit LCD display of engine hours, engine rpm, DC battery voltage, oil pressure, and water temperature. Includes pushbutton to hold display on any single parameter. Protection Shutdowns: Overspeed, overcrank, high water temperature, low oil pressure, and emergency stop. With LED indicator for each condition. Alarms: Low coolant level AC Metering Three-phase volts (L-L), amperes and frequency with phase select pushbutton, on backlit LCD. Metering accuracy is 0.5%. Control Automatic starting with field adjustable cycle crank, failure to start (overcrank), and cooldown timer. Programming and Diagnostics Includes field programmable set-points for engine control and monitoring variables and self diagnosis of EMCP II system component and wiring failures. Alarm Module Flashing LED warnings for: low coolant temperature, high coolant temperature (pre-alarm), low oil pressure (pre-alarm), engine control switch not in automatic, and low DC voltage. Includes alarm horn and acknowledge pushbutton.

STANDARD CONTROLS (Continued) Manual Paralleling Controls consisting of reverse power relay, synchronizing lights, and switch. Reverse power condition causes tripping of the generator circuit breaker, immediate engine shutdown, visual indication, and sounding of alarm horn. Current Transformers (3) Governor 2301A electronic speed control with 3500 power modules, mounted in EMCP II with speed adjust potentiometer PSG governor, speed raise-lower switch with 3412 power modules Circuit Breaker Generator mounted, three-pole, manually operated, molded case circuit breaker with solid state trip unit for overload (time overcurrent) and fault (instantaneous) protection. Includes DC shunt trip coil activated on any generator set monitored fault. Circuit breaker is sized for full load capacity of the generator set at 0.8 power factor. Accessory Power 3400 Power Modules (60 Hz units) One 240 VAC shore power connection for jacket water heater One 120 VAC shore power connection for generator space heater and battery charger (50 Hz units) Two 230 VAC shore power connections for jacket water heaters, generator space heater, and battery charger. Bus Bars Three-phase plus fully rated neutral bus bars with NEMA standard hole pattern for connection of customer load cables. Bus bars are sized for full load capacity of the generator set at 0.8 power factor. Also includes ground bus, connected to generator frame ground and container frame with holes for connection of field ground cable. Bus bars are accessible from outside of the power module via hinged, lockable cable access door. Battery Charger 24 VDC/20A battery charger with float/equalize modes, charging ammeter and battery voltmeter. Well mounted within the power module. Materials and specifications are subject to change without notice. The International System of Units (SI) is used in this publication. LEHX7305-01 Printed in U.S.A. 1997 Caterpillar Inc. Supersedes LEHX6113 All rights reserved.