Version: 1.0 Mat.-Nr.: DBUS-WB50-80US

Similar documents
Wind power inverter WINDY BOY 5000-US/6000-US WINDY BOY 7000-US/8000-US. 1 Notes on this addendum. 1.1 Validity. 1.2 Target group

Wind Power Inverter WINDY BOY 5000A/6000A

PV Inverter SUNNY MINI CENTRAL 9000TL / 10000TL / 11000TL with Reactive Power Control

Wind Power Inverter WINDY BOY 1200/1700

Wind Power Inverter WINDY BOY 1100LV

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

PV Inverter SUNNY BOY 3300/3800

PV Inverter SUNNY BOY 3300/3800

Multi-Function Interface MULTI-FUNCTION RELAY

PV inverter SUNNY MINI CENTRAL 7000HV

WINDY BOY. Grid Connection of Small Wind Turbine Systems

Operating parameters WINDY BOY

Operating instructions. sonnenprotect for operators. KD-337 Part no Version X00.

System Description SMA FLEXIBLE STORAGE SYSTEM in the United Kingdom

PV inverter SUNNY BOY 2100TL

Wind Power Inverter WINDY BOY 3600TL / 5000TL

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

Aurora Wind Interface Box

Sunny Boy Accessories SUNNY BOY COMBINER BOX TLUS SBCBTL6

OPERATING MANUAL. Wind / Solar Hybrid - Charge Controller 24V 1000w. i/hcc Charge Controller

Electric Networks/Ina Lehto Updated Original 12/2011

M u l t i P o w e r. CM MultiPower. Installation and Operating Manual

DER Commissioning Guidelines Community Scale PV Generation Interconnected Using Xcel Energy s Minnesota Section 10 Tariff Version 1.

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Unit Protection System for Pumped-Storage Power Stations

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

9.1.4 Troubleshooting of Faults in LCD Screen

Technical Information Control of the Active Power Feed-In at the Grid-Connection Point with the SMA CLUSTER CONTROLLER

Operating manual UPS - System

Combiner Manual #OMBINER #OMBINER < 2* )NSTALLATION 7(&+12/ i 62/$5

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

8 Troubleshooting and Maintenance

System description Off-Grid Systems with SUNNY ISLAND 4.4M / 6.0H / 8.0H

Technical Information Temperature Derating for Sunny Boy and Sunny Tripower

Installation - Quick Reference Guide Off-Grid Systems

User Manual SMA FUEL SAVE CONTROLLER 2.0

System Monitoring SCHOOLMETERBOX AU

User s Manual. Automatic Switch-Mode Battery Charger

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 03

Advanced Hybrid Wind / Solar Charge Controller. User Manual

Whad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF

System description Multicluster Systems with Stand-Alone Grid or Increased Self-Consumption and Battery-Backup Function

Energy storage kits for residential and commercial customers. Ken Hobbs Technical Director, CCL Components Dean Kalek Technical Trainer, SMA Solar UK

Accessories for power generation plants in Italy SMA GRID GATE

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 01

Charge controller SUNNY ISLAND CHARGER

Modular Standardized Electrical and Control Solutions for Fast Track Projects

SBCB-6, SCCB-12, 28, 52 6 to 52 Circuit Combiner Boxes

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

SINAMICS GM150 IGCT version

Technical Information SUNNY BOY / SUNNY TRIPOWER Temperature Derating

BMW i. Freude am Fahren. BMW i Wallbox Plus. Instructions for use

Accessories for Stand-alone inverter SUNNY ISLAND GENMAN

Operating Manual SUNNY ISLAND 3.0M / 4.4M / 6.0H / 8.0H SUNNY REMOTE CONTROL. SI30M-44M-60H-80H-BE-en-33 Version 3.3 SUNNY REMOTE CONTROL

User Manual. Hybrid PV Inverter. Version: 2.1

INTRODUCTION. Specifications. Operating voltage range:

Regenerative Utility Simulator for Grid-Tied Inverters

4.2 Component Identification

Central Inverter SUNNY CENTRAL 500CP-JP / 500CP XT / 630CP XT / 720CP XT / 760CP XT / 800CP XT / 850CP XT / 900 CP XT

Manual. EN Appendix. Lynx Ion BMS 400A / 1000A

BMW i. Freude am Fahren. BMW i Wallbox Plus. Owner's manual

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

SimpliPhi Power PHI Battery

User Manual. 3kW Hybrid PV Inverter HX-3000

Inverter / Charger Accessory for Steca Solarix PLI Phase / Parallel Kit. Installation and operating instructions Z01 17.

Integrated Plant Control and Q on Demand 24/7 SUNNY TRIPOWER

Technical Manual Electrical Power Supply System T4002

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

Foreword

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

Central Inverter SUNNY CENTRAL 500HE-20/630HE-20/720HE-20/ 760HE-20/800HE-20

Automatic Genset Controller, AGC-4 Display readings Push-button functions Alarm handling Log list

BMW i. Freude am Fahren. Wallbox PURE. Installation instruction

USER MANUAL. 10 January Certification of constancy of performance CNBOP No CPR-0454 Certificate of admittance CNBOP No.

DEEP SEA ELECTRONICS PLC DSE3210 Configuration Suite Software Manual

DC-PMM/24V Power Management Modul für Positionier-Motor POSMO A Power Management Module for Positioning Motor POSMO A

HANGKAI GROUP HOYMILES MICRO-INVERTER MI-250

SUNNY BACKUP System. Solar Power Even in the Event of Grid Failure

PV Master OPERATION MANUAL

Trusted technology for maximum power yield SINAMICS W180 siemens.com/sinamics-w180

Pulsar EXtreme 2200C / 3200C

User Manual SMA FUEL SAVE CONTROLLER 2.0

Static frequency converter couples US paper mill s 25-Hz and 60-Hz electricity grids

Sunny Island 3324/4248 User Manual

Operating Instructions

Wilo-Control SC-Fire Jockey

Technical Explanation for Inverters

Pulsar Evolution 1500 / 1500 Rack 1100 / 1100 Rack 800 / 800 Rack 500 Rack

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Micro Inverter with Communication Unit SUNNY BOY 240-US SUNNY MULTIGATE-US

Models DP10 & DP20 Series Low Voltage Disconnects User s Manual Rev. 1.1 October 31, 2007

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

.3 Section Waste Management and Disposal.

RENEWABLE ENERGY TRAINER

MODEL 233P/111P/233P-1.5

Armature Reaction and Saturation Effect

RT2DB Excitation and voltage regulation system for synchronous generators

GloboFleet. User Manual EAN / GTIN GloboFleet Downloadkey II

Transcription:

WINDY BOY 3000-US / 5000-US / 6000-US / 7000-US / 8000-US Addendum operating requirements Version: 1.0 Mat.-Nr.: DBUS-WB50-80US 1 Notes on this addendum 1.1 Validity This addendum does not replace the attached Sunny Boy installation guide. Pay attention to all operation and safety instructions listed in the Sunny Boy installation guide. The Sunny Boy installation guide is delivered with the Windy Boy inverter. This addendum describes necessary confingurations for operating a Windy Boy in combination with a small wind turbine system. This addendum is valid for the following Sunny Boy installation guides: Sunny Boy 3000-US Sunny Boy 5000-US Sunny Boy 6000-US Sunny Boy 7000-US Sunny Boy 8000-US The listed types of inverters are referred to in the following as Windy Boy. 1.2 Target group This addendum is for qualified personnel. Qualified personnel have received training and have demonstrated skills and knowledge in the construction and operation of this device. Qualified personnel are trained to deal with the dangers and hazards involved in installing electric devices. 1.3 Appropriate usage Use the Windy Boy only in combination with a small wind turbine system having a permanet magnet generator. Do not operate the Windy Boy without using a rectifier with overvoltage protection like the Windy Boy Protection Box. Do not use the Windy Boy for purposes other than those described here. Alternative uses, modifications to the Windy Boy or the installation of components not expressly recommended or sold by the manufacturer void the warranty claims and operation permission. Addendum operating requirements 1/12 DBWB50-80US-UUS101710

Electrical connection Concept of a wind turbine system using this Windy Boy When designing the wind turbine system, ensure that the values comply with the permitted operating range of all components at all times. The manufacturer of the wind turbine must have approved the turbine for use with the Windy Boy. 2 Electrical connection 2.1 Safety precautions DANGER Risk of electric shock due to high voltages inside the Windy Boy. Death or serious injuries will result. All work on the Windy Boy must only be carried out by qualified personnel. All work on the Windy Boy must only be done as described in this manual. Pay attention to all safety instructions. NOTICE Electrostatic discharges possible when components are touched. Damage to components will result. Follow ESD protective provisions. Remove existing electrostatic charges by touching a grounded metal surface (e.g. housing). Addendum operating requirements 2/12 DBWB50-80US-UUS101710

Electrical connection 2.2 Load disconnection unit DANGER Risk of electric shock due to missing protective function on the line circuit breaker. Death or serious burn injury will result. When a generator and a consumer are connected to the same line circuit breaker, the line circuit breaker loses its protective function. The current from the inverter and the grid can add up to overcurrent which is not detected by the line circuit breaker. Never connect loads between the inverter and the line circuit breaker without protection. Always install separate fuses for loads. Use only line circuit breakers as load disconnection units! A screw type fuse element, e.g. D system (Diazed) or D0 system (Neozed) is not a circuit breaker, and thus must not be used as a load disconnection unit. When disconnecting under load, the fuse element may be damaged or its functionality may be impaired by contact burning. It only acts as cable protection. Detailed information and sample designs of a line circuit breaker can be found in the Technical Information "Line circuit breaker" in the download section of www.sma-america.com. 2.3 Connecting the turbine to the rectifier For proper connection refer to the installion guides of the wind turbine system and the attached Sunny Boy installation guide. 2.4 Connecting the rectifier to the Windy Boy For proper connection refer to the attached installion guide of the Sunny Boy and the rectifier. Addendum operating requirements 3/12 DBWB50-80US-UUS101710

Turbine operation 3 Turbine operation The Windy Boy is a single phase inverter that converts DC current into AC current and feeds the energy generated by a wind turbine system into an existing power supply system. The Windy Boy inverter has a special operating mode for wind generators (see figure below). That allows performance adjustment to the characteristic curves for generators of many different manufacturers. In this way maximum yields can be obtained from your wind turbine system. The mechanical power of the wind turbine is delivered to the Windy Boy in the form of a direct, rotational-speed variable DC voltage (RPM) and current intensity (torque). Most small wind turbine systems have a permanent magnet generator. For converting the variable frequency AC generator voltage into DC current a rectifier like the Windy Boy Protection Box is needed. If a different operation mode is displayed: Activate the operating mode Turbine by using Sunny Data Control. If problems occur contact the SMA-Service. 3.1 Characteristic curve function The "Turbine" operating mode of the Windy Boy uses a programmable characteristic curve to regulate the input current depending on the generator voltage. A characteristic of wind turbine systems is that for every rotational/wind speed there is a different optimal working point for voltage and current. This behavior is not linear. The Windy Boy approaches this non-linearity using an approximation composed of a number of connected linear functions. These can be programmed by the user to correspond closely to the behavior of the small wind turbine system and thus provide performance adaptability. The illustration on the next page shows the connected linear functions of a typical characteristic curve for the Windy Boy. It shows feed-in AC power of the Windy Boy as a dependent variable of the DC input voltage. The adjustable parameters UPV Start, UDCWindStart and UDCWindMid, UDCWindMax and Pmax are used to adapt the power/voltage curve of the Windy Boy to the particular wind turbine system. Addendum operating requirements 4/12 DBWB50-80US-UUS101710

Turbine operation The correct configuration of the parameters shown in the diagram is absolutely necessary to guarantee optimal performance with wind generators from different manufacturers. The Windy Boy also has a soft-start parameter P-Wind-Ramp. This parameter protects the mechanical components of your wind turbine system and thus contributes to a longer system life. Other adjustments are possible to optimize the maximum performance of the Windy Boy with a particular small wind turbine system, by adjusting the regulation speed and also by setting the switch off and switch-on times ( T-Stop, T-Start ). 3.2 Characteristic curve operation The characteristic curve of the Windy Boy only approximates the actual characteristics of a real small wind energy system. Consult the manufacturer of your wind generator for its typical characteristics before changing the curve parameters. Switch-on procedure During the startup phase, the small wind energy system is running almost load-free. The Windy Boy only requires the power needed to supply the on-board electronics. If enough on-board power is available, this operating status is indicated by simultaneous lighting-up of the three light-emitting diodes (LEDs) on the cover. As soon as the DC input voltage defined in the parameter UPV-Start is reached, the Windy Boy begins a number of self tests, measurement processes and synchronizes with the grid. This status is indicated by a blinking green LED. If the self tests are successfully completed, and the DC input voltage remains above the value defined in UPVStart for the time defined in T-Start, the Windy Boy connects to the grid. This status is indicated by a continuosly lit green LED. Addendum operating requirements 5/12 DBWB50-80US-UUS101710

Turbine operation The inverter then switches into characteristic curve operation and regulates the input current based on the voltage of the wind turbine system. The power defined in the characteristic curve for the wind turbine system is thus fed into the grid. This status is indicated by a continuosly lit green LED. Here you should be able to abserve that, as the inverter switches into characteristic curve operation, the small wind energy system is placed under load, i.e., the rotational speed and the DC input voltage should fall. The amount by which the input voltage decreases depends on the small wind energy system being used. Characteristic curve operation As soon as the DC input voltage reaches the value defined in UDCWindStart, the Windy Boy begins feeding power into the grid. As you can see from the characteristic curve, the power fed into the grid rises with the DC input voltage. UDCWindStart can be set to be less than UPV Start. This makes mains feed-in possible at low DC input voltages. However, this setting depends on the voltage level of the grid. As soon as the DC input voltage reaches the value defined by the parameter UDCWindMid, the output power reflects the value set by the PWindMid parameter. If the voltage increases further, then the power increases according to characteristic curve region II. In order to reflect the typical behavior of a real small wind energy system, characteristic curve region II is steeper than characteristic curve region I. As soon as the DC input voltage reaches the value defined in the parameter UDCWindMax, the Windy Boy feeds the grid with the maximum possible power. If the input voltage continues to rise, the Windy Boy continues to feed the grid at maximum power. The maximum power reflects the maximum AC power of the Windy Boy, but this can be reduced using the Pmax parameter. The characteristic curve ends at the maximum permissible input voltage of the Windy Boy, which must never be exceeded. Shutdown If the wind strength is so low that the DC input voltage falls below the internally calculated minimum operating value of Umin, then thewindy Boy ceases feeding power into the grid for the period defined in T-Stop. If the DC input voltage increases again, then the T-Stop timer is deleted and the Windy Boy will operate according to the characteristic curve again. If the DC input voltage remains below Umin for the time defined in T-Stop then the Windy Boy switches off. If the DC input voltage is no longer sufficient to supply the on-board electronics, then the Windy Boy switches off immediately. After the switch-off, the whole process begins anew. Addendum operating requirements 6/12 DBWB50-80US-UUS101710

Turbine operation 3.3 Changing the power characteristic curve In order to configure the Windy Boy, a DC input voltage - within the MPP range of the Windy Boy - is needed. In addition, the Windy Boy must be connected to the grid voltage. Ensure that the operating mode Turbine is activated. In addition to the communications possibilities described in the attached Sunny Boy installation guide, you can also implement a simple parameter setting using an optional "USB service interface". This special cable allows communication between a PC and a single Windy Boy. The USB service interface can only be used by opening the Windy Boy. Observe the safety instructions in the operating and installation manuals for your Windy Boy. You need to install the Sunny Data Control software on your PC, which is available from the download area at www.sma-america.com. The Sunny Data Control software is a PC program for direct monitoring and configuration of your Windy Boy, which also allows visualization and logging of various system parameters. Once you have finished setting the parameters, the service interface must be removed and the Windy Boy must be closed. The connection is therefore not suitable for permanent installation. Addendum operating requirements 7/12 DBWB50-80US-UUS101710

Turbine operation 3.3.1 General setting example The following example represents a starting point for the operation with a wind generator. Contact the manufacturer of your wind generator for information on its typical properties (voltage/power characteristic). UPVStart is set to approx. 20 % above the lower limit of the MPP range of the Windy Boy: This achieves an early switch-on of the Windy Boy. UDCWindStart is set to the lower limit of the MPP range of the Windy Boy: This achieves an early grid feed-in. P-Wind-Mid is set to approx. 1 / 5 of the maximum AC power of the Windy Boy. UDCWindMid is set to the upper third of the voltage range between UDCWindStart and UDCWindMax. The selection of this point separates the characteristic curve into weak and strong wind regions and this is decisive in achieving optimum power adjustment for your small wind turbine system. It should be noted that the characteristic curve is shallow in the weak wind region and much steeper in the strong wind region. The flat characteristic curve in the weak wind region avoids a "braking" effect on the wind turbine system caused by extraction of too much power, and this provides good startup characteristics. The steeper region of the characteristic curve leads to a more rapid increase in the power extracted at higher DC input voltages. This behavior reflects the typical properties of small wind energy systems. UDCWindMax is initially set to approx. 10 % below the maximum MPP voltage of the Windy Boy: Once the properties of the wind generator are known, then the reduction of the UDCWindMax parameter may be necessary in order to extract the maximum power from the wind generator even at low DC input voltages (low wind speeds). The increase in the second characteristic curve region thus becomes even steeper. Pmax is set to the maximum output power of the small wind energy system: This allows the maximum AC power of the Windy Boy to be ideally tuned to suit the wind turbine being used. This avoids the wind turbine system being overloaded through extraction of too much power. T-Stop is set to the maximum value: The Windy Boy remains connected to the grid even at low DC input voltage levels waiting for the next gust of wind. This delays an early switch-off of the Windy Boy. T-Start is set to the minimum value: This achieves a reduction of the switch-on time (observe the regulations of the grid operator in charge). Addendum operating requirements 8/12 DBWB50-80US-UUS101710

Commissioning 4 Commissioning 1. Check the following requirements before commissioning: Correct mounting and correct connection of the inverter. Correct layout of the line circuit breaker. Correct grounding of the small wind turbine system according to the manufacturer's instructions. Rectifier and overvoltage protection (e.g. Windy Boy Protection Box) between the small wind turbine system and the inverter have been installed. 2. Commission the small wind turbine system according to the instructions of the manufacturer. The green LED glows or blinks: commissioning has been successful. or The red or yellow LED glows or blinks: an error has occurred. Object A B C Description Green LED: Operation Red LED: Ground fault Yellow LED: Disturbance Addendum operating requirements 9/12 DBWB50-80US-UUS101710