www. ElectricalPartManuals. com outdoor oillnaken type GC aingle tank descrlpllve bullella page l 14.4 lev 100,380 and BOO mva 23 lev 280 mva

Similar documents
www. ElectricalPartManuals. com Westinghouse Single Tank Outdoor Oil Breaker Type GS 69 Kv

Westinghouse Electric Corporation Distribution and Control Business Unit Assemblies Division Bloomington, Indiana

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Horizontal Circuit Switchers

Horizontal Circuit Switchers

Typical Specification

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

SWITCHGEAR DIVISION PRODUCT PROFILES

www. ElectricalPartManuals. com INSTRUCTIONS "INERTEEN AND OIL INSULATED FEEDER SWITCHES DESCRIPTION INSTALLATION MAINTENANCE

www. ElectricalPartManuals. com

ABB Automation, Inc. Substation Automation & Protection Division Coral Springs, FL Allentown, PA

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

4.0 OPERATION Type ITH-T Relay

3.0 CHARACTERISTICS E Type CO-4 Step-Time Overcurrent Relay

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!

Three-Phase Pole Mounted Recloser

www. ElectricalPartManuals. com TRI-PAC circuit breakers current limiting protectors for. lighting, power and distribution circuits

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008

ichards MANUFACTURING COMPANY, SALES, INC. 517 LYONS AVENUE, IRVINGTON, NJ Phone Fax

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

Power & High Voltage Joslyn Hi-Voltage Overhead Reclosers & Switches H-220. Series HVI Hi-Velocity Interrupter Attachment

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

Publication No.: PSG

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

MAHALAKSHMI ENGINEERING COLLEGE TIRUCHIRAPALLI

ABB Power T&D Company Inc. Relay Division Coral Springs, FL Allentown, PA. Non-Directional, Single Phase Adjustable Time Delay Device No.

Indoor or Outdoor 2400 to 14,400 Volts 600 to 14,400 Kvac, 3 Phase, 60 Hz

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits.

EE 741 Over-voltage and Overcurrent. Spring 2014

www. ElectricalPartManuals. com lncoming-6900 through 69,000 volts Outgoing-2400 through 13,800 volts Ratings:

Sectionalizing. Rick Seeling. Pete Malamen. Introduction Philosophy. Three Phase Reclosers High-Side Protection Specific Applications

Pretest Module 29 High Voltage Unit 1

ABB. Type CRQ Directional Negative Sequence Relay for Ground Protection B 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION CAUTION

Type SOQ Negative Sequence Time Overcurrent Relay

University of Houston Master Construction Specifications Insert Project Name

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

A. Submit manufacturer's literature and technical data before starting work.

Descriptive Bulletin. R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Types VSA12, VSA12B, VSA16, VSA20, and VSA20A; three-phase; air-insulated; electronically controlled recloser

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

L. Photo. Figure 2: Types CA-16 Relay (rear view) Photo. Figure 1: Types CA-16 Relay (front view)

C1000 Series Automatic Cap Bank

Instructions for Installation, Operation and Maintenance of Low Voltage Power Circuit Breakers Types DSII and DSLII

SIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

IN2 Enclosed Switches and Circuit Breakers

Eaton s Cooper Power Systems catalog Medium-voltage vacuum circuit breakers

Figure 1. Type CWP-1 Ground Relay (Front View) Figure 2. Type CWP-1 Ground Relay (Rear View) E

1. Take the cover off the relay, taking care to not shake or jar the relay or other relays around it.

Switchgear Arrangement, Torque Requirements, Insulation Systems & Maintenance Intervals. Mike Schmaderer

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

2.0 CONSTRUCTION AND OPERATION 3.0 CHARACTERISTICS K. CO (HI-LO) Overcurrent Relay

Electropneumatic Timing Relays Series 7000 Industrial

SECTION MOTOR CONTROL

CA Breaker Instruction Manual

KFE10002-E. Reclosers. Type KFE and KFVE Electronically Controlled Vacuum Recloser Installation Instructions. Service Information

COOPER POWER CA280012EN

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

www. ElectricalPartManuals. com CPL Station Arrester Controlled Protective Level Page 1 Indoor-Outdoor Altitude 0-10,000 feet KV

Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana 47401

CLEAVELAND / PRICE INC. Type RL-C Side Break Switch kv A. Bulletin DB-104E12

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

33KV INDOOR SWITCHGEAR

COM Overcurrent Relay

www. ElectricalPartManuals. com Instructions for Load Break Air Switch, Type LBF, for Power Centers

Figure 1. HX cutout fuseholders.

CITY OF MARYVILLE ELECRIC DEPARTMENT Maryville, Tennessee SPECIFICATIONS FOR 15KV POWER CIRCUIT BREAKERS. September 2018

OTEC Transfer switch open transition

FULL VOLTAGE STARTERS z SIZE 8 SERIES B CONSTRUCTION

Product Specifications for Aluminum Vertical Break Switches

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

BGE STRATEGIC CUSTOMER ENGINEERING

Transfer switch OTEC open or delayed transition

AIR CORE REACTORS. Phoenix Electric Corporation

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

17.1. Low Voltage Switchgear. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

Figure 1. HX cutout fuseholders. Positive Interruption

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

www. ElectricalPartManuals. com INSTRUCTION BOOK h'o. AIR CIRCUIT BREAKER Types 50-DB-ISOE and 50-DB-2501 j,," ,,,,< W_,;wkiiii i!t;s..;._.:...:..,fk.

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:

Solid Dielectric, Single Phase Recloser

OHB Outdoor sulphur Hexafluoride circuit-breaker

Medium Voltage Metal-Enclosed Switches

SECTION PANELBOARDS

Switchgear. Low Voltage

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

A - Add New Information C - Change Existing Information D - Delete Information. Page 7. Delete the fourth paragraph beginning CAUTION

Underground Distribution Switchgear

Transcription:

October, 1959 supersedes db 33-ZSl dated November, 1956 mailed to: E/Z75,Z79/DB: D64-5C: CZ6-5Z,b :::....... outdoor oillnaken type GC aingle tank 14.4 lev 1,38 and BOO mva 23 lev 28 mva appucatioa descrlpllve bullella page l Westinghouse type GC outdoor oil filled circuit breakers combine efficient interrupting capacity with low maintenance and short arcing time. The three phases of these breakers are mounted on a common top and enclosed within a single tank. DE-ION grid control reduces fault clearance time, con tact burning and oil deterioration. High speed reclosing systems are available as optional equipment. advaatages single DE-ION grid per pole condenser bushings solenoid operating mechanism longer oil life low maintenance

page 2 deliga featares breaker with tank lowered for maintenance and inspection The type GC breaker is designed to provide large "power type breaker" features in a unit with distribution substation ratings. It is completely factory assembled, tested, and when shipped is ready for installation. DE-ION grid operation combines efficient interrupting capacity with low maintenance and short arcing time. 1 condenser bushings This design provides weatherproof construction with ample insulation, high mechanical strength, light weight. In each bushing the conductor through the center has a liberal current-carrying capacity. Around this are wound layers of treated paper interspersed with metal foil to form the condenser insulating member. After machining, the mounting flange is pressed on the condenser to form a rigid support. The outer end is protected from the weather by a single-piece porcelain. The porcelain is flexibly supr;orted at its base by a copper ring and at its top by a copper cap to permit normal expansion and contraction. Space inside the porcelain is filled with a soft plastic. All joints are sealed to assure a weatherproof casing. types condenser bushing The top casting forms one section of the two-piece clamp type terminal. This terminal will handle conductors from no. 2 wire to 1 MCM cable and also bolted on bus bar. bushing-type current s: Multi-ratio bushing-type current s with Hipersil cores meet all NEMA and ASA requirements for relay and indicating instrument applications. One per phase is supplied as standard on 14.4 breakers, two per phase can be supplied if required (two per phase are standard on 23- breakers). Single-ratio s with Hipernik cores are also available for metering applications which require greater accuracy. The s are mounted in the breaker top and leads are carried to the mechanism housing through a short connecting nipple. Pressure-type gas seal prevents breaker gas from entering the mechanism housing.

current characteristics maximum turn rating in ratio amperes 6 I ZOO 2 to 1 4 to 1 6 to 1 8 to 1 12 to I 4 to I 8 to 1 12 to I 16 to I 24 to I marked ratio polarity marks secondary taps 1 to 5 X1-X2 2 to 5 X3-X4 3 to 5 X2-X3 4 to 5 XI-X3 6 to 5 XI-X4 2 to 5 XI-X2 4 to 5 X3-X4 6 to 5 X2-X3 8 to 5 XI-X3 12 to 5 XI-X4 minimum primary amperes for relay+ pick-up 9 165 245 325 485 165 325 485 645 965 + minimum trip values based on one per phase with shunt trip or capacitor-trip and with type CO relay on the 4-ampere selling. 2 pressed steel breaker top: All phases are mounted in a common top, and enclosed in a single cylindrical tank. Pressed-steel breaker top supports the terminal bushings and contact assemblies and houses the operating shaft which connects the mechanism to the contact lift rods. A float-type oil gauge provides visual indication of the oil level, and a filling pipe provides a means for filling the tank with oil. 3 welded steel framework: Welded steel framework supports the circuit breaker and its operating mechanism housing. A removable tank lifter and pulleys are provided, by which the tank can be raised or lowered. 4 tank lifter: A portable windlass tank lifter is available to raise and lower the breaker tank for maintenance and inspection. Lifter may be operated by one man with a minimum of effort, outdoor oil breakers type GC single tank descriptive bulletin 33-251 14.4 1, 25 and 5 mva 23 25 mva page 3 S SAH-4 solenoid current terminal blocks Rectox and control panel control terminal blocks solenoid operating mechanism: Weatherproof mechanism housing mounted on the breaker framework encloses the operating mechanism and control relays. Reclosing equipment can be added to the mechanism on a swinging panel in front of the rectifier assembly, page 8. Swinging door, equipped with padlock latch, provides easy access to the mechanism. A heater prevents condensation of moisture. The hexagonal operating shaft enters the top of the housing through a sealed corrosion-resistant bearing. Type SAH-4 mechanism is mechanically trip-freebreaker can be tripped in any position whether closed manually or by the solenoid. Standard arrangement has cutoff switch, 9-pole rotary type auxiliary switch, 125-volt closing coil, shunt trip coil, and control relay panel. Mechanism can be furnished with four tripping coils, three for tripping from current s and one for shunt trip. Rectox rectifier: A plate-mounted selenium rectifier can be included for operation of the solenoid closing mechanism from an a-c supply. Shunt trip coil can be provided for 48 or 24-volt battery operation. capacitor trip device: When only a-c control power is available for both closing and tripping, a capacitor trip device can be supplied for operation of a shunt trip coil. Thus, the same flexibility of relaying may be obtained as with d-e shunt trip coil, which makes capacitor tripping superior to overload tripping.

page 4 deaipleatuea internal construction DE-ION grids a DE-ION grids: The use of a single DE-ION grid interrupter per phase results in several advantages, such as hinged moving contacts for double contact speed, simple operating linkage and greater electrical clearance between phases. The grid stacking and exhaust vent configuration controls the pressure and turbulence in the arcing zone which results in fault interruption times of less than 5 cycles over the complete range of interrupting currents. The grids, supported from the condenser bushings, consist of a stack of insulating plates which form oil pockets to de-ionize the arc quickly. While passing through the zero point in the current wave, the dielectric strength of the arc stream builds up so rapidly that the current remains at zero to interrupt the circuit. This fast arc extinction minimizes contact burning, oil deterioration, and breaker maintenance. The 23 breaker utilizes a slightly different interrupter. b hydraulic bumper: A single oil dashpot operated by the center lift rod lever absorbs the shock of opening and prevents rebound of the moving contacts. c lift rods: Micarta lift rods are operated by levers on the operating shaft. Because the moving contacts are held permanently in alignment, lift rod guides have been eliminated, and the opening in the DE-ION grid for the moving contact has been made smaller for more efficient arc control. d contacts: The moving contact consists of a hinged bridging member attached to the foot of the condenser bushing. Contact pressure at the hinge joint is maintained by the use of self-aligning cupped spring washers. A butt-type stationary contact is used which is backed up by heavy biasing springs in order to get good contact pressure and the fast contact parting time required for 5 cycle interruption. The moving and stationary contacts are both tipped with silver tungsten for good arc resistance combined with high conductivity. When 12 ampere continuous rating is required, an additional silver surfaced contact of the "tuning fork" type is mounted outside the interrupter. Sufficient contact area, mass, and pressure are used to keep operating temperatures within safe limits, c d

standard circuit breaker includes: W em co "C" oil welded structural steel frame six condenser bushings connecting nipple and pressure-type seal for leads oil drain valve, and filling pipe float-type oil gauge accelerating spring maintenance closing device (one per station) mechanism with weatherproof housing (see page 3) 3-multi-ratio bushing-type current s (6 standard on 23GC25) solenoid mechanism housing includes: swinging door equipped with padlock latch solenoid closing mechanism: 125 or 25 volt d-e, 23 volt a-c shunt trip coil: 48, 125, or 25 volt d-e or capacitor trip control relay panel necessary terminal blocks cutoff switch operation counter space heater fused knife switch for control circuit 9-pole rotary type auxiliary switch optional equipment available at extra cost: (for details see price list 33-24) reinforced grids for capacitor switching: see t.d. 33-63 extra creepage bushings high altitude bushings linear couplers for bus differential relaying metering accuracy bushing current s windlass-type tank lifter automatic reclosing equipment (see page 8) special relays, meters, instruments and cabinets type co relay cs t -? 1!rip COil '+-----+- to capacitor trip device or battery -o+--+-4 outdoor oil breakers type GC single tank 14.4 1, 25 and sao mva 23 25 mva ' sahematla dlagl'ams descriptive bulletin 33-251 page 5 diagrams in accordance with AEIC-NEMA industry standard Reclox close d c ll'ip l'eclosi 6 Reclox close d c ll'lp aoa nclosbat

page 6 l'atiags breaker maximum design.,.... rated voltage... insulation level ratings, 6-cycle 1 minute withstand. 1.5 x 4 impulse withstand. continuous current rating..... short time current ratings, momentary. four-second. interrupted ratings, rated three phase mva... ampere @ rated voltage. maximum amperes... minimum for rated mva... opening and closing times Time required to interrupt the circuit, measured from the instant the trip coil is energized with normal voltage to the final interruption, at 25 to 1 p'=!rcent of rated capacity (6-cycle timing wave)............. Time required to close the breaker at normal control voltage, measured from the instant the control switch contacts meet until the breaker arcing contacts meet (6-cycle timing wave). operating mechanism closing current of solenoid at 125 volts.... solenoid tripping current at 125 volts.... number of auxiliary switch contacts provided to c ren trip circuit. contacts contact travel...,....... break distance.... bushings... ::I phase spacing.... safe cantilever loading of bushing, installed.... external creepage distance, phase-to-ground... phase-to-phase... external striking distance, phase-to-ground... phase to-phase.... "' interrupting performance 3 u.. u 2.5 "' :a C> c.." I units mva cycles cycles lbs I breaker type 144GCIOOI 144GC25ol 144GC25j 144GC5ool 144GC5ooi 23GC25 15.5 14.4 5 llo 6 24 15 1 4 15 3.85 5 18 35 11 2 8 7 15Y2 1 11.5 23 6V,, 12% 15.5 14.4 5 llo 6 4 25 25 1 25 5.8 5 18 35 11 8 15Y, 1 ll.5 23 6V,6 12% 3-phase ungrounded tests :E 2 4 6 8 :o 12 :4 16 18 interrupted current cmps X 1 15.5 15.5 15.5 25.8 14.4 14.4 14.4 23 5 5 5 6 11 llo 11 15 12 6 12 6 4 4 4 19 25 25 25 12 25 5 5 25 1 2 2 63 25 25 25 12 5.8 11.6 11.6 12 5 5 5 5 18 18 18 18 35 35 35 35 11 11 11 11 2 2 2 2 8 8 8 BY., 7 7 7 7Y., 15% 15% 15% 16Y, 1 1 1 1 ll.s ll.5 ll.5 17 23 23 23 34 6% 6V,, 6V,6 lly., 12% 12% 12% 13% 2 22 24 26 www. ElectricalPartManuals. com

dimensions in four l in. bolls to project 2in. above floor. bolls not furnished by Westinghouse \t""'"'' space to E c D r 76t outdoor oil breakers type GC single tank 14.4 1, 25 and 5 mva 23 25 mva clamp type terminal for no. 2 wire to 1 MCM cable, or bollea on bus bar hand closing lever --15-75.!- I 2 3 poles breaker amp mva outline dimensions weight type bkr lbs A-1 A-2 B c D E F G H 144GC1 14.4 6 1 144GC2SO 14.4 6 25 144GC2SO 14.4 12 25 144GCSOO 14.4 6 5 144GCSOO 14.4 12 5 Z3GC2SO 23. 6 25 12% 28Y2 12% 9TVs 92 12 17Y, 8% ISYa 12% 28Y, 12% 97Vs 92 12 17Y:! 8% ISYa 12% 28Y, 12% 97Vs 92 12 17Y, 8% 15Ys 12% 28Y:! 12% 97% 92 12 11y2 8% 15Ys 12% 28Y:! 12% 97% 92 12 17Y:! 8% 15Ys 13% 31% 13% IOOY, 96 125 19Y,, 9' y,, 16% 244 244 25 244 25 254 descriptive bulletin 33-251 page 7 wt bkr oil less oil gals. lbs 21 45 21 45 216 45 21 45 216 45 22 4!:i

descriptive bulletin 33-251 page 8... t.aaatic outdoor oil breakers type GC single tank eclosiag equipment To restore service automatically after fault clearance, type GC circuit breakers may be equipped with an automatic reclosing package. Reclosing equipment is mounted on a hinged panel housed in the operating mechanism cabinet. Complete factory assembly, inspection and testing minimize installation time and expense. included in the standard automatic reclosing package Weatherproof cabinet mounted on the breaker frame contains the following apparatus, completely wired and tested: one type RC recloser in Flexitest case three type CO overcurrent relays in Flexitest cases three type RA-35 miniature ammeters (5 amperes full scale) one type W control switch two indicating l, red and green one two-pole fused knife switch one toggle switch for automatic operation cutoff terminal blocks type CO ground relay (optional) instantaneous trip on type CO relays (optional) instantaneous initial trip with time-delay, subsequent trip (optional) Westinghouse Electric Corporation Power Circuit Breaker Division printed in U.S.A. Trafford, Pa. miniature ammeters RC relay toggle switch type W switch CO ground relay optional CO relays operation type GC circuit breaker with reclosing mechanism The type RC recloser is normally arranged for a total of three reclosures. The first may be immediate or time-delay with automatic reset if the breaker stays in or lockout if the breaker trips immediately after th third reclosure. After lockout, the breaker will not reclose automatically and hence must be closed manually. If the breaker is tripped manually by the control switch, a contact in the control switch is opened and the breaker will not reclose automatically. Automatic operation is restored by manually closing breaker through the control switch. rating factors: All ratings are based on the standard duty cycle (2-C-15 sec.). For duty cycles other than standard, breaker should be derated in accordance with technical data 33-6. instantaneous initial trip: For instantaneous initial tripping followed by delayed subsequent tripping, an integral contact of the RC reclosing relay is used in conjunction with CO relays with instantaneous trip contacts brought out to separate studs. lurtlaer information prices: price list 33-22 price list 33-24