Installation Instructions

Similar documents
INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight

Specification Grade Contemporary Wall Mount/Technical Installation Data

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing

MOONRING 1.5 MOONRING 3

Captivate Illuminated Mirror Light

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

NL-FTPR150, FUNCTIONAL TRAINER ASSEMBLY INSTRUCTIONS

Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame

VWM SERIES U L R. Instruction Sheet. Vertical Wall Mount Rack LISTED

Cable Cubby 1202 and 1402 Installation Guide

MAXLITE RKT LED Retrofit Kit

HOMELINK DOOR OPENER KIT

SF 10C SUB Subwoofer Setup Guide

Cable Cubby 650 UT Installation Guide

LED DayLite WireLess Mini

CSD Series Current Devices Split Core

INSTALLATION INSTRUCTION Bollard Light 12V

UB-2 2 Universal Button

LED DayLite Micro. User Guide Ver

Fan Relay Board (FRBii) Assembly

LS1 SERIES IMPORTANT: READ ALL INSTRUCTIONS THOROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF LINEAR SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE.

Instruction Sheet ERK-XXXXKD SERIES KNOCKDOWN STANDALONE RACK

Installation Instruction

LAL SERIES LED LUMINAIRE

Wet Rated Batten LED Luminaire

Installation And Operation Instructions For FHSCP-UNV Series Emergency LED Drivers Models: FHSCP-UNV-5WL, 7.8WL, 10.7WL, 13.

P78 Series Controls for Dual Pressure Applications

Lumination TM LED Luminaires LAL Series - Continuous Run Option

INSTRUCTION BOOK FOR. Tensioned Advantage Deluxe Electrol

2-WAY REMOTE STARTING SYSTEM WITH 1 BUTTONS FOR AUTOMATIC TRANSMISSION RED301-2WAY / ANT-2WDSS. User Guide For Key

Have a bright day! Nicholas Harmon President, Verilux, Inc.

Cable Cubby 1200 and 1400 Installation Guide

GETTING STARTED WITH IN-WALL DIMMER SWITCH

M Remote Mounting Kit

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

BEDIENUNGSANWEISUNG KD KD KD KD KD KDEM KDEM mit Montageanweisungen

Cable Cubby 500 and 700 Installation Guide

OSQ Series IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Area Light TO INSTALL:

Have a Bright Day! Nicholas Harmon President, Verilux, Inc.

INSTALLATION INSTRUCTIONS

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS!

RSA-MRZ Installation Instructions

VA-4233-AGx Series Electric Valve Actuators

Certification Exhibit FCC ID: SK9OW1 IC: 864G-OW1. FCC Rule Part: IC Radio Standards Specification: RSS-247. ACS Project Number:

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed

INSTALLATION INSTRUCTION Bliss - Vanities & Wall Sconces WS-79622

RSA-MRZ Installation Instructions

Sure-Lites. Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. IB505037EN Important Safeguards

WARNING / AVERTISSEMENT

INSTALLATION INSTRUCTIONS

POOL BOY Powered Solar Blanket Reel

M9300 Series Switch Kits

M9300 Series Potentiometer Kits

Installation Instructions

KT-EMRG-1400-SL /B. 3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

Spun Bay Installation Standard Version (non dimmable), Hook Mount

M Remote Mounting Kit

INSTRUCTION BOOK FOR. Tensioned Dual Masking Electrol

ChlorSM Series SALINE CHLORINATOR. Installation, Operation, and Maintenance Manual

Retractor SM Installation Guide

3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

Mobile Crane/Grue mobile LTM

INSTALLATION INSTRUCTION Oculux 3.5" Architectural Downlight R3CRN-11, R3CSN-11

M9109-GGx-5 Series Proportional Electric Non-spring Return Actuators

IMPORTANT SAFEGUARDS

(SB2) (SB1) (SB3) (SB5) (SB4) Cylindrical Installation Instructions. A. CHECKLIST (4 each AA Batteries Included) (SB1) (SB4) (SB2) (SB6) (SB6) (SB3)

Assembly and Operation Manual

Air Purification Unit. Operation and Maintenance Manual

INSTRUCTION BOOK FOR. Tensioned Advantage Electrol

IMPORTANT: SAFETY INSTRUCTIONS Important: Instructions de securité

Air Purification Unit. Operation and Maintenance Manual

Eaton 9395 High Performance* Sync Installation Controland Operation Manual

IMPORTANT SAFETY PRECAUTIONS

INSTALLATION INSTRUCTION Vanities & Wall Sconce WS-85618

Installation Instructions

MNBE-8D2x2 INSTRUCTIONS

System 350 S350C Temperature Slave Stage Module

Algae Control System. SEE INSTRUCTIONAL VIDEOS: sonicsolutionsllc.com

97Ti, 95Ti, 93T Treadmills Assembly Instructions

POOL. Manual. PBBP001R2

2200C. Operation and Maintenance Manual. HEPA Air Filtration Machine BY OMNITEC DESIGN, INC. BY OMNITEC DESIGN, INC. BY OMNITEC DESIGN, INC.

Lumination TM LED Luminaires Suspended LED Fixture (Series EP14)

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

Safety, Installation and Operating Instructions Instructions importantes concernant la sécurité

INSTRUCTION BOOK FOR. Boardroom Electrol

Letter Band Phonics Jam

VA2202-xxx-2 Series Electric Spring Return Valve Actuators

Instruction Guide 325/326/327

ELV1abbccd-e. Color Temperature: 30 = 3000K White 35 = 3500K White 40 = 4000K White 45 = 4500K White 50 = 5000K White

Solid Clamps Raccords orientables

INSTRUCTION BOOK FOR. Dual Masking Electrol

2000C. HEPA Air Filtration Machine. Operation and Maintenance Manual

Troubleshooting Guide

P78 Series Controls for Dual Pressure and Hazardous Location Applications

Transcription:

Installation Instructions FHEZ10A24 FHEZ17A48 Page 1 of 7

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 1. Do not mount near gas or electric heaters. 2. Do not attempt to service the battery. Replace entire Battery Unit when necessary. Contact the manufacturer for information on service. 3. Equipment should be mounted in locations and at heights where it will not be subjected to tampering by unauthorized personnel. 4. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. 5. Do not use this equipment for other than its intended use. SAVE THESE INSTRUCTIONS GARANTIES IMPORTANTES LISEZ ET SUIVEZ TOUTES LES INSTRUCTIONS DE SÉCURITÉ. 1. Ne pas monter près de radiateurs à gaz ou électriques 2. N'essayez pas de réparer la batterie. Remplacez la batterie entière lorsque nécessaire. Contactez le fabricant pour obtenir des informations sur le service. 3. L'équipement doit être monté à des endroits et à des hauteurs où il ne sera pas possible être soumis à des altérations par du personnel non autorisé. 4. L utilisation d équipements accessoires non recommandés par le fabricant peut provoquer une condition dangereuse. 5. N'utilisez pas cet équipement pour un usage autre que celui auquel il est destiné. CONSERVEZ CES INSTRUCTIONS Maximum mounting height / Hauteur maximale de montage: a) For 2 ft version 20ft for FHEZ10y24 b) For 4 ft version 25ft for FHEZ17y48 Page 2 of 7

1. Locate and gather the necessary Tools and Contractor Supplied Materials: A. Lineman, Wire Splicers, Flat Head Screwdriver B. 8 Wirenuts, Supporting materials for the driver. a. Driver can be installed different ways to meet each individual need: Surface mounted to a beam or wall Supported to ceiling drop wire with the (2) caddy clips supplied using (2) ¼-20 machine screws and hex nuts to bolt the driver to the caddy clips when secured to the drop wire. Supported to (2) T-Grid Standoffs by installing the T-Grid Standoffs to the top of the grid and using (2) ¼-20 Machine Screws and Hex Nuts to bolt the fixture to the standoffs. 2. Locate the location where the EZ EXIT luminaire will be installed and remove the surrounding ceiling tiles. 3. Identify your power source and junction box for the driver and extension harness; be sure the junction box is within the given distance of the extension harness. 4. Using your flat head screwdriver, pry the tabs apart on each end of the piece of grid you are removing. A. Be sure when you remove this piece you leave the tabs from the opposite grid pieces in place; this will help align your EZ Exit luminaire and keep it straight for the existing tiles. Page 3 of 7

5. Unbox your EZ EXIT luminaire and remove your 2 or 4 fixture and place it in the ceiling where the grid piece was removed, or the new fixture is to be installed. Line up the L bracket at the end of the EZ Exit luminaire with the tab of the opposite grid. See photos below. 6. Use the two of the provided short tek screws to secure the luminaire to the grid by using one screw on each side Page 4 of 7

7. Take the 10 extension harness and plug in the WAGO Quick Connect to the end coming off the fixture. Run the 10 extension harness to your junction box location. In route to the junction box you can utilize the caddy clips to support the wire above the ceiling. Note: Extension harness is to be mounted at least 6in away from the EZ luminaire, and Emergency Driver. Page 5 of 7

8. Open the junction box with your emergency power circuit and identify the circuit you will be using is turned off at this time. 9. Remove (2) ½ knockouts from your junction box. One will be used for the ½ 2-screw connector with the low voltage wires from the luminaire. The second knockout will be for the flex whip from the driver. 10. Mount the driver in one of the three mounting types and make sure it is secure. Fasten the flex connector in the junction box and identify your wires. 11. For wiring instructions please reference the Wiring Diagram Bellow. EZ Exit Wiring Diagram Test Switch TOP VIEW EZEXIT LED Test Switch LED Module WIRE EXTENSION Inverter Connector Cap Unused Leads To Unswitched AC Power Yellow/Black Yellow Violet Brown White/Black Blue White(Common) Black TOP VIEW FHSCP-UNV Page 6 of 7

12. Connector the two-battery quick connects together and close the junction box. 13. Restore power to the circuit. Verify the red Test button is illuminated and test the fixture by pushing the test button to illuminate the fixture. Turn the power off and verify the fixture turns on when power is lost. Note: Please make sure that all electrical connections conform to National Electrical Code and local regulations. 14. Re-install all ceiling tiles, and the install is complete. Page 7 of 7