Liebert GXT-MT 1-3kVA UPS. Power Protection for Business Critical Continuity

Similar documents
TECHNICAL DATA SHEET KVA UPS Systemss

EFFEKTA Power Supplies

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

3 Uninterruptible Power Systems

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

ELEKTRA SERIES I.T GRADE ONLINE DOUBLE CONVERSION UPS 10KVA ~ 500KVA (3/3) Mission Critical & I.T Grade UPS

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Liebert NX TM. 250kVA kVA Transformer-free. High Efficiency, Scalable On-line UPS

SmartOnline 3-Phase In/Out 120/208V 20kVA 16kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, DB9 Serial, Hardwired

3 Uninterruptible Power Systems

Via Somalia, Cormano (MI) - ITALY Ph Fax:

Aurora Single Phase Emergency Lighting Inverters

Protection and conditioning against all forms of power anomalies.

Uninterruptible Power Supplies

» Sophisticated» Reliable» Intelligent

SENTINEL VA

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

True double-conversion online single-phase UPS. PowerValue 11 RT 1 10 kva Single-phase UPS for critical applications

Liebert NXC. 10kVA - 60kVA. Compact, Efficient, and Reliable Power Solution

Liebert GXT4. Intelligent, Reliable UPS Protection 5kVA - 10kVA

Phase Modular Finally the benefits of Modular ups are for all

3 Uninterruptible Power Systems

Est ComPower Mini UPS (3 Phase) CPX Mini 10 50kVA

Master DIALOG INDUSTRY RANGE

POWER kva

Liebert GXT4. Intelligent, Reliable UPS Solution 700VA - 3kVA

Uninterruptible Power Systems

Security Plus Online Uninterruptible Power Supply

Uninterruptible Power Supplies

PowerWAVE EL. Technical Specification. (Single phase 500 VA 30 kva. Three phase kva)

2 Uninterruptible Power Systems

Liebert GXT4. Intelligent, Reliable UPS Protection 5kVA - 10kVA

POWER kva

Liebert. FP 50Z kva

PowerValue 11/31 T kva

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms)

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

Est FlexiPower Mini UPS FPX Mini kVA

On-line, Single Phase, Double Conversion UPS

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

Technical Data Sheets

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

Modular UPS «AGIL» Stay on! Changing the rules for critical business continuity :

D Series: UPS UPTO - 300KVA - Three / Three Phase

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

S2000 PRODUCT RANGE. Ultra compact

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Three-phase UPS system. DPA UPScale ST kw Best-in-class modular UPS for maximum availability

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

Uninterruptible Power Systems

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Uninterruptible Power Systems

Technical Data Sheets

Power+ CLASSIC. 20/30 kva, 3x208 Vac

magellan commercial UPS solutions Magellan Power Modular - Flexible UPS

3 Uninterruptible Power Systems

3 Uninterruptible Power Systems

Technical Data Sheets

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

MKN-DSP SERIES - THREE PHASE

POWERTRONIX QUASAR 5-40 KVA

Series 120/120VAC Universal Tower/Rack Mount

Technical data sheets

Model ES VA to VA SINGLE PHASE UNINTERRUPTIBLE POWER SYSTEM

Technical Data Sheets

Master Plus kva

Three-phase UPS system DPA UPScale ST kw The modular UPS designed for lowand medium-power applications

ST1K series specification

YOUR POWER IN SAFE HANDS. E Series UPS

Liebert GXT VA RT230 Rack-Tower model GUIDE SPECIFICATIONS 1.0 GENERAL

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

Liebert GXT & 6000VA RT230 Rack-Tower models GUIDE SPECIFICATIONS 1.0 GENERAL

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

PowerScale TECHNICAL SPECIFICATIONS

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

Technical data sheets

Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA

PowerScale kva Technical Specifications

NterpriseIP Solution Adaptive, high-availability power system for IP Telephony. Business-Critical Continuity for Communications

Technical Data Sheets

Technical Data Sheets

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

ST6K(S) series specification

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

PRODUCT CATALOG (IEC) Low-power UPS. Low-power UPS

SINGLE-PHASE SOLUTIONS UNINTERRUPTIBLE POWER SYSTEMS

Liebert. PSI & PSI-XR 750VA - 3kVA & 1kVA-3kVA High Performance Power Protection for Servers and Networking Equipment

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

Onfiniti. 1 Phase UPS

Liebert. GXT4 700VA - 3kVA Fully Digital Dual DSP Controlled UPS

Transcription:

Liebert GXT-MT 1-3kVA UPS Power Protection for Business Critical Continuity

Trouble is Coming Down The Line And You Must Be Prepared Every operation in your business depends upon the instant, around-the clock availability of computers, servers and other electronic systems. If they aren t working, neither is your company. Every piece of this equipment your company possesses is subject to the whims of the electricity that powers it. The first step in taking control of this situation is to understand the threats to your system reliability and exactly what you can do about them. The Liebert GXT-MT True Online Double Conversion UPS With Extended Runtime Capabilities Liebert GXT-MT features a comprehensive specification, satisfies safety criteria and electromagnetic compatibility standards, and offers intelligent monitoring and network management functions. Liebert GXT-MT satisfies your requirements for high reliability and high availability of the AC power supply. Liebert GXT-MT is available in a compact Tower configuration making it easily deployed in an office or a light industrial application. Liebert GXT-MT long run model (L) deploys adaptive battery architecture to maximise your valuable rack space utilisation. Application specific battery configuration and placement ensures optimal performance. NOTE:- Liebert GXT-MT standard model is provided complete with internal battery. Liebert GXTL-MT (long back up model) application specific battery and cabinet available through your local Emerson Network Power representative.

Applications Features Small Size Data Center Telecommunication, VoIP Small Office Network Data Warehouses Medical Diagnostics Process Automation Equipments Extended Runtime Capabilities Flexible (Site Specific) Battery Configuration Compact Tower design. Generator Compatible Class B Electromagnetic interference (EMC) compatible Ultra wide input voltage range High capacity Battery Charger for GXTL High input power factor & low THDi Sourcing the Liebert GXT-MT Available from all Uptime Partners Email marketing@emersonnetwork-ap.com for your nearest Uptime Partner Liebert GXT - MT

True Online Double Conversion Excellent performance True Online Double Conversion UPS with Zero transfer time. The online design ensures no output interruption upon mains failure, ensuring maximum uptime. Ultra wide input voltage range: 110~300V minimizes the battery discharge frequency, protects the battery capacity, and offers a super output overload capability. The system can maintain the online operation for up to 30 seconds even at 150% overload. High Capacity battery charging capability: Liebert GXTL- MT is equipped with a 4Amp (1kVA unit) and an 8Amp (2 and 3kVA unit) charger to ensure fast battery recovery as well as enabling extended battery autonomy. Electro Magnetic Conduction (EMC) compliant to Class B delivers strong immunity protection levels. Liebert GXT-MT maintains a low level of Input current THD and highest possible Input power factor (up to 0.97), making it an energy efficient and conservative choice. High reliability Design Built-in automatic bypass assures power continuity during maintenance and system fault. The inverter uses advanced current limiting technology to protect the system against potential output short circuit.

Flexible Configuration Extended Run Time ready facilitated through a simple process of building up additional battery resources. Multiple AC output interfaces via IEC standard sockets Convenient maintenance Fault type is clearly displayed for fast troubleshooting. Battery Capacity Indicators LED display provides maximum operational convenience when managing the UPS. Intelligent Management functions Stronger Battery charger on the GXT L model for quick recharge Remote Monitoring is available through RS232, and optional via dry contacts and SNMP. The monitoring option software supports TCP/IP with event log and analysis function. Self-diagnosis and protection enable the auto shutdown of the client terminal or server under abnormal mains supply or when battery is over discharged.

True On-Line Double Conversion Technology: When Adequate protection is not enough Technical Specification, Liebert GXT-MT Mechanical Module W H D (mm) Weight (kg) Power module GXT1000-MT 145X220X400 14 Power module GXT1000L-MT 145X220X400 7 Power module GXT2000-MT 192X347X460 34.5 Power module GXT2000L-MT 192X347X460 15 Power module GXT3000-MT 192X347X460 35.5 Power module GXT3000L-MT 192X347X460 16 EMS Item Standard Level ESD immunity IEC61000-4-2 Level 4 RS immunity IEC61000-4-3 Level 3 EFTB immunity IEC61000-4-4 Level 4 Surge immunity IEC61000-4-5 Level 4 EMI Item (for GXTL models) Standard Level Limitation of emission of input harmonic currents EN61000-3-2 - Limitation of voltage changes, voltage fluctuations and flicker EN61000-3-3 - Conducted Emission EN50091-2 Class B Radiated Emission EN50091-2 Class B Environmental Item Ambient temperature Relative humidity Normal range 0 C~40 C Less than 90% Condensing Altitude Storage temperature Lower than 1000m; no derating; 1000~1500m; 1% derating for every 100m rise -0 C~40 C (excluding battery)

Electrical Model Rating Input Output Input system Rated voltage Voltage range Frequency Power factor Output system Power factor Voltage Line regulation Voltage harmonic distortion (rated input voltage, rated input frequency) Dynamic variation Frequency Frequency range Inverter overload capability (in Normal mode, 25 C) Inverter overload capability (in Battery mode, 25 C) Bypass overload capability Crest factor Bypass operating voltage Transfer time DC component GXT 1000-MT GXT 1000L-MT GXT 2000-MT GXT 2000L-MT GXT 3000-MT GXT 3000L-MT 1000VA/700W 2000VA/1400W 3000VA/2100W 1-phase, plus PE 220Vac / 230Vac / 240 Vac 1. 160~300 Vac full load 2. 110 Vac half load 50/60 Hz 0.97 (conditions: rated voltage, full pure resistive load, fully charged battery) 1-phase, plus PE 0.7 220Vac / 230 Vac / 240 Vac ±2% 2%(0~100% linear load) 3%(0 ~100% linear load) 6%(0 ~100% non-linear load) <5% in 20 ms 50 / 60 Hz ±0.2Hz 46-54 Hz / 56-64 Hz 108%~150% 30s >150% 300ms 108%~150% 30s >150% 300ms 300% for 5s 3:1 80~264V Normal< _ >Battery: 0ms 200mV 200% for < 60 mins External battery voltage 36Vdc 96Vdc Charging current 1A 4A 1A 8A 1A 8A Battery Qty. Volts. Capacity 3 12V 7.2Ah - 8X12X7.2Ah - 8X12X7.2Ah - Manufacturer / model Value added Optional parts: WEB/SNMP card AS400 CSB/GP1272F2 or Panasonic equivalent - CSB/GP1272F2 or Panasonic equivalent - CSB/HRL1234W F2 or Panasonic equivalent - Typical Autonomy Time 12 Minutes - 15 Minutes - 9 Minutes - Autonomy at Half Load 20 Minutes - 26 Minutes - 16 Minutes - Charging duration 80% of battery capacity in 4 hrs (standard type) Noise (within 1m) GXT1000L-MT, GXT2000L-MT, GXT3000L-MT: <45db Protection IP20(static state)

Emerson Network Power 1050, Dearborn Drive, P. O. Box: 29186 Columbus, Ohio - 43229 Tel.: 800.877.9222 (US & Canada Only) Tel.: 614.888.0246 (Outside US) Fax: 614.841.6022 Country Office Emerson Network Power (India) Private Ltd. Plot No. C-20, Road No. 19, Wagle Estate, Thane (w), Maharashtra - 400 604. India. Tel.: 91-22-25807000/ 2388 Fax: 91-22-25828358 Voice of Customers UPS Awards 2004-05 for Product Line & Customer Service Awards in IT, Telecom, Large Enterprise & Hospitals and Customer Service Leadership Award in BFSI City Offices West Zone Mumbai : 022-25002318/2294 Pune : 020-66235000 Baroda : 0265-2314296/2330383 Nagpur : 0712-5634997 Indore : 0731-4023806 Ahmedabad : 079-55228287 East Zone Kolkata : 033-40023100/01/90 Jamshedpur : 0657-2227678 Guwahati : 0361-2453270 Bhubaneshwar : 0674-2586003/3299872 North Zone New Delhi : 011-25824206/08 Chandigarh : 0172-5077531 Lucknow : 0522-2237174 South Zone Bangalore : 080-41135670/770/870 Secunderabad : 040-27806771/772 Cochin : 0484-2341985/86 Chennai : 044-28151063/28152596 Vishakapatnam : 0891-2505540 Best IT Hardware Company Maharashtra IT Award 2005-06 2005 R