Mid-Power Remote Unit (MRU) SISO Outdoor Enclosure Assembly Quick Installation Sheet

Similar documents
Mid-Power Remote Unit (MRU) Outdoor Enclosure MIMO Assembly Quick Installation Sheet

Cellwatch Electrical Installation

Installing Power Components

Sentinel Field Satellite Controller

Singlemode Fused Coupler LGX Module (832 Series)

BLACK BOX. Fully assembled, ready-to-use wallmount cabinets. Elite Wallmount Cabinet User s Manual. Customer Support Information

Product Specification Sheet #3LD2.1

AIS and 40 kva 400 V. Site Preparation and Installation Manual

Outdoor Enclosure Power System ENC X100MP48F20-AC6

PowerWorx DSX Series GMT Fuse Panel User Manual

Fiber Optic Above-Ground) Cross-Connect Enclosure (ACE) Model ACE-200DS Installation Guide)

Enclosed Rotary Switch Product Specification Sheets Table of Contents

HP BladeSystem c7000 Carrier-Grade Options Installation Guide

Installation Instructions for Eaton Surge Protective

Outdoor Enclosure Power System ENC X100MP48F20

*Phillips Screwdriver *10mm Nut Driver *10mm Socket *Ratchet *Three Inch Putty Knife *Panel Removal Tool *10mm Wrench CONTENTS:

AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS

GMT Fuse Panel Installation Guide

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

VERTIV XTE 401 SERIES. Ordering Guide

ANZI Transfer Switch and Generator Wiring Installation Addendum

SAVE THESE INSTRUCTIONS

WLP Series Wall Mounts (WLP Series Low Profile Wall Mount Enclosure) Installation Instructions

MA-5200 Series MA-5300 Series

TPM Fuse Panel Installation Guide. Document INS-727XXXXXXX This manual covers the following part numbers- Trimm 727XXXXXXX Family

E.S.P. Embedded Sensing Probes for Motor Brushes

ROUSH Active IO Exhaust. Installation Instructions P/N: (R LITE) Fastback GT Convertible GT V8

AMP NETCONNECT 19 NETWORK AND SERVER RACK SYSTEM.

Quick Connection Panel (QCP) Installation Guide

Total Front Access Wall Mount Fuse Panel Installation Guide. Document INS This manual covers the following part numbers

Operation & Maintenance Manual

PVM 220 Installation Guide

Cabinet and Rack Installation

I-BFV.KIT Butterfly Valve Gear Operator Replacement

Owner's/Installation Manual

Fiber Connector Shelf (CCS)

ChargePoint Gateway Installation Instructions

Control Panel Interface Upgrade Installation Guide For Model 200i and 250i Motorcycle Dynamometers Serial Number 202xxxx.

PowerWorx Power Distribution Products Select Series Circuit Breaker for ±24 or ±48 Vdc User Manual

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

poollux Power plx-pw60 & plx-pw100

Raritan PX. Power Cord Installation Guide. Safety Guidelines. Safety Instructions

DCCB-L DCCB-L-175 DCCB-L-250. Owner s Guide. Sine Wave Plus DC Conduit Box Long

Cabinet and Rack Installation

Fully assembled, ready-to-use custom cabinets.

INSTALLATION INSTRUCTIONS FOR EGA AND EGH SERIES ELECTRIC HEATERS IN V OR H SERIES UNITS

VD0C06N908C July 1998 Raleigh, NC, USA. Instruction Bulletin ALTIVAR 66, ALTIVAR 58, ALTIVAR 18. Dynamic Braking Resistor Kit User s Manual

MODEL CMA-44 PARTS MANUAL Rev 2.13

DM-100 Creep Detection System Installation Manual

M100F Incremental Motor Actuator R81F Interface Board

50A Dual-Feed 5/5 GMT Total Front Access Fuse Panel

Alcatel-Lucent 7310 DC Metro Cell AWS (B4) Kit MC-DBR1, MC-DBR2, MC-DBR3, MC-DBR4, MC-DBR5. Installation Manual

Instructions for 2-row monitoring only

Cantilever Series Mounting Instructions Chevy Express (AD) present

Instructions for 2-row monitoring only

2-row and All-row systems included.

5-Slot and 2-Slot Panels Installation Guide

Environmental Distribution Center (EDC-06P-NH)

Technical Manual. DLM Module. This manual should remain with the unit.

Z22C-** Preconfigured Network Zone System

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

INSTALLATION INSTRUCTIONS AM rev. A

CTFRP Series Power Supplies

installation manual imagine the possibilities Accessory Heat Kit For V-AHU VHK- A Thank you for purchasing this Samsung product.

E Series Enclosures Installation Instructions (UL /UL2416 E Series Equipment Cabinet/Rack)

Chapter 3. Installing Equipment

INSTALLATION GUIDE. For Carrier/Bryant Residential Power Systems

Installing and Removing Power Supplies

PVM 220 Installation Guide

Installation Instructions for John Deere cotton picker models: 9986 & 2-row and All-row systems included.

Westell Boxer BXM1019 NHE3 & BXM1019 NHE3G Outdoor Cabinets with 24VDC/ 48VDC Heat Exchanger

AMP NETCONNECT 19 NETWORK AND SERVER RACK SYSTEM.

PBA Series Prelube Controls

Safety Products. Safety Products. HS5E Series. HS5E Series Miniature Solenoid Locking Switch

Enclosure for AMP1 Series Energy Meters with Swing Panel Kit

IMPORTANT SAFEGUARDS

Installation and Operation Guide. Tundra HD 2500 Power Inverter. for the. Webasto BlueCool Truck System

ROADRELAY 5 Installation Guide

*Phillips Screwdriver *10mm Nut Driver *8mm Nut Driver*10mm Socket *Ratchet *Three Inch Putty Knife*Panel Removal Tool *10mm Wrench

Date: Order No.: Supersedes: Group:

CON EDISON EQUIPMENT

LED Downlight Ceiling Fixtures

MNBRATKIT MidNite Brat Solar Charging Kit

Florham Park, NJ USA Call (ASCO) for sales or service

MaxDim Installation Instructions

SED2 Variable Frequency Drive Electronic Bypass (E-Bypass) Options

5300 Series Installation Guidelines

8300 Series Installation Guidelines

Boxer BXM05V19 NMT Sealed Outdoor Cabinet with Vertical 5 RU Rack

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHR18 THRU 60* WARRANTY

HS1E Series Full Size Solenoid Locking Switches

Recommended Tools: Phillips Screwdriver, Flat Blade Screwdriver, 13mm and 10mm Wrench, 5/16 nut driver,

Pretium Wall-Mountable Housing (PWH-02P/-04P/- 06P/-12P and FZB-02P-JB)

Company Switch Installation Instructions and User Manual

DCS-400 Measuring Chains with LIN-340 Signal Conditioner and 10m Triaxial Cable Front End Installation Manual

INSTALLATION INSTRUCTIONS

TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

MGB Alternator Conversion Installation Instructions For MGA & 1962 to 1967 MGB

Motorized Stainless 2-Way Valves

Transcription:

Mid-Power Remote Unit (MRU) SISO Outdoor Enclosure Assembly Quick Installation Sheet CMA-437-AEN 1. KITS REQUIRED FOR INSTALLATION GENERAL INFORMATION 1. Additional relevant documentation: MRU quick installation sheet provided with the unit (or download from Corning partner portal: CMA-398-AEN) Purcell FlexSure 12-GR487 installation manual provided with the cabinet 2. Only trained and qualified personnel should be allowed to install, replace, or service this equipment. 3. Corning recommends using the Mean Well SDR-140-48 DIN rail AC/DC converter or equivalent. 4. The MRU connections are performed after the chassis is installed in cabinet. This document provides instructions on how to install the Corning optical networks evolution (ONE ) solutions mid-power remote (MRU) into a Purcell cabinet (FlexSure 12RU outdoor GR-487 enclosure) and perform external alarm connections between the unit and the enclosure. The following kits are required for installing the MRU in the outdoor enclosure. Each kit is ordered separately. Kit Item Quantity FLX12-GR487 Enclosure Purcell FlexSure 12U Outdoor GR-487 Enclosure for single MRU installations SISO cabinets: Purcell 2000004343 FLX12-GR487-R, 39W/C HEX, right-hinge door Purcell 2000004344 FLX12-GR487-L, 39W/C HEX, left-hinge door 1 MRU-E-XXXXX-AC/DC Mid-Power Remote Unit 1 AK-MRU-DCA-CBL AK-FLX1216-POLE-MK (optional) AK-FLX12-WALL-MK (optional) Table 1. Required Kits External Alarms Cable; DB9 male open wire cable for external alarm connections Platform Pole-Mountable Kit for FLX12 and FLX16 outdoor enclosures Purcell P/N: 2000003986 Wall-Mountable Kit for FLX12 outdoor enclosures and assemblies P/N 2000003985 1 1 1 Quick Installation Sheet CMA-437-AEN Page 1

2. ADDITIONAL REQUIRED ITEMS (NOT SUPPLIED) Standard electrician tools (including ratchet wrench with extension bar and 8-mm socket) for tightening self-drilling screws securing MRU chassis to cabinet rails Assorted cable ties 90-degree right-angle 4.3-10 type male connector coax cables one for antenna connection and one for external 2.5 GHz RF source connection (if relevant) Recommended Flexible cable conduits for routing connection cables through cabinet knockouts; refer to Figure 2 for relevant knockouts. Following are recommended Heyco part numbers for flexible conduits (or equivalent): Manufacturer Part Number Description 8406 HFC 1 Conduit Fitting with 8467 nut, 1-in thread, black 8453 HF2 1 Tubing, 100-ft coil, black 8456 HFC 2 Tubing, 50-ft coil, black 8642 HFC 2 Conduit Fitting, 2-in thread, black Table 2. Recommended Conduits Sealing material for knockouts if not using conduits Recommended DIN rail power supply for MRU AC models Mean Well SDR-120-48 or equivalent; Input: 100-240 V AC; 1.4 A 50/60 Hz; Output: 48 V; 2.5 A DIN rail TS-35/7.5 or 15 cut to the length between the enclosure internal upright brackets; used for mounting DIN rail power supply Slotted 4-mm screwdriver for SDR wiring Quick Installation Sheet CMA-437-AEN Page 2

3. PRE-INSTALLATION PROCEDURES Step 1: Step 2: Remove each rack ear and reassemble according to position shown in Figure 1. Referring to Figure 2 for relevant knockouts, use appropriate knockout tools to punch out knockouts for routing connection cables. Figure 1. Required Position of MRU Rack Ears Figure 2. Required Knockout Positions ATTENTION! In the event that a PAM or the OPTM needs to be removed from the chassis, make sure to first press the release button on the module and then pull out using the handle (see Figure 3). Any attempt to pull out the module without first releasing may cause damage. Corning will not be liable for damage of products resulting from improper handling during installation or repair. Figure 3. Extraction of PAM/OPTM Quick Installation Sheet CMA-437-AEN Page 3

4. INSTALL MRU IN CABINET Step 1: Carefully lay cabinet on backside (so door faces upward) and open door. ATTENTION! Make sure that the door hatch locks into the door rail in order to avoid closing of door while installing the chassis. See Figure 4. Note: Push hatch inward towards the door to release and close the cabinet. Step 2: Insert one 8-mm self-tapping screw (provided with the cabinet) halfway into the bottom hole of each rail. Refer to Figure 5. Note: An extension bar may be required to access the screws due to narrow space between chassis and cabinet rails. Step 3: Step 4: Position the bottom-half slots of the MRU rack ears onto the protruding screws and tighten the screws using a ratchet wrench. Refer to Figure 6. Insert at least two additional screws into each of the cabinet rails to safely secure MRU and tighten. Figure 4. Opening Cabinet Door and Locking in Place 5. (OPTIONAL) INSERT CONDUITS IN KNOCKOUTS Insert the appropriate conduits in each of the punched-out knockouts. Figure 5. Inserting Self-Tapping Screw in Each Rail Figure 6. Securing MRU to Cabinet Rails Quick Installation Sheet CMA-437-AEN Page 4

6. GROUND CABINET AND MRU Step 1: Step 2: Ground cabinet refer to the manufacturer s installation guide for instructions on cabinet grounding. Using one of the grounding cables provided with the cabinet, ground the MRU chassis via the two-hole, standard-barrel grounding lug located on the front panel to one of the cabinet grounding bolts. Refer to Figure 7. 7. CONNECT RF ANTENNA COAX Figure 7. Grounding MRU to Cabinet For both 4.3-10 Type ANTENNA PORT and 2.5 GHz INPUT PORT route coax cable (with 90-degree right-angle connector) through its designated knockout (see Figure 2) behind and above the MRU chassis and connect to the corresponding RF port. Refer to Figure 8. 8. ROUTE FIBER AND POWER CABLES IMPORTANT! If cables are routed without the use of conduits, the knockouts must be sealed using appropriate sealing materials. Route optical fiber from path panel and power cable through designated knockouts (see Figure 2) and connect according to instructions in MRU quick installation sheet. Refer to Figure 8. Note: For DC power connections, route DC power cable with open wires (without connector) and then wire according to instructions in MRU quick installation sheet (CMA-398-AEN). Figure 8. Example of Routed Connection Cables Quick Installation Sheet CMA-437-AEN Page 5

9. INSTALL AND CONNECT DIN RAIL POWER SUPPLY (RECOMMENDED FOR MRU AC MODELS) Recommended DIN rail power supply: Type: Mean Well SDR-120-48 or equivalent Input: 100-240 V AC; 1.4 A 50/60 Hz Output: 48 V; 2.5 A Recommended fuse and maximum number of SDR-120 PSUs for a 230 V circuit breaker: Fuse Circuit Breaker C16 D16 T4A / L250V 7 14 Step 1: Secure the DIN rail to the upright brackets in the enclosure. IMPORTANT! Make sure to install the DIN rail so that there is equal space above and below the power supply to be mounted. This is required to ensure sufficient airflow. Figure 9. Installation Location of DIN Rail Power Supply Step 2: Mount the DIN rail power supply onto the right side of the installed rail, as shown in Figure 9. Wiring requirements: Use copper wires only. Use wires that can withstand a minimum temperature of 80 C (e.g., UL1007). Recommended wire strapping length = 0.197 in (5 mm). Recommended wires: AWG 18 16 14 12 10 Rated Current of 6 6-10 13-16 16-25 25-32 Equipment (Amp) Cross-Section of Lead (mm 2 ) 0.75 1.00 1.5 2.5 4 Notes: When using five or more wires connected to the unit, the current of each wire should be derated to 80 percent of the recommended current above. The maximum allowable cross-sectional area of the wire for the SDR terminal is 12 AWG/2.5 mm 2 Figure 10. Overview of Recommended SDR Connections Step 3: Using 3 A gauge wires, connect pair of DC wires from the -V and +V terminal block connectors to the socket box on the right of the enclosure. Quick Installation Sheet CMA-437-AEN Page 6

Step 4: Using 2 A gauge double-insulation wire, connect SDR to AC inlet power. See Figure 11 for illustration of connections between external enclosure and DIN rail power supply. IMPORTANT! Make sure that all strands of each stranded wire enter the terminal connection and the screw terminals are securely fixed to ensure good contact. If the power supply consists of multiple output terminals, make sure each contact is connected to wires to prevent excess current stress on a single contact. 10. PERFORM EXTERNAL ALARMS CONNECTIONS BETWEEN MRU AND CABINET Note: Also refer to relevant section of the cabinet installation manual (i.e., Connecting Optional Custom Alarms ). Step 1: Connect the external alarms cable (ordered separately) to the chassis DB9 External Alarms connector. The connector provides indications for door opening, heat exchanger (HEX), and one additional input for future use. Refer to Table 3 and Figure 11 for MRU External Alarms connector pinout and location. Pin Description 1 Common 2 Not connected 3 Not connected 4 Not connected 5 Not connected 6 Door alarm 7 HEX alarm 8 Future alarm 9 Exist indication (indicates existing connection of alarm cable) Figure 11. Location of External Alarms Connector and Cabinet Alarms Block Table 3. MRU External Alarms Connector Pinout Description Quick Installation Sheet CMA-437-AEN Page 7

Step 2: Route the cable alarm wires to the alarm block, located on the cabinet s upper right corner Step 3: Connect the external alarm connections to the cabinet according to Table 4. Color Red Green Brown Black White Description +48 V_COMMON -48 V_EXIST INDICATION -48 V_DOOR ALARM -48 V_HEX ALARM -48 V_FUTURE ALARM Table 4. External Alarms Cable Wiring Description Refer to Table 5 for wiring description of MRU external alarms connector and to Figure 12 for examples of the upper and lower cabinet block wiring connections. External Alarms Connector Pin No. 1 Common 6 Door Alarm 2 NC 7 HEX Alarm 3 NC 8 Future Alarm 4 NC 9 Exist Indication 5 NC Note: NC = Not Connected Table 5. External Alarms to Cabinet Block Wiring Quick Installation Sheet CMA-437-AEN Page 8

Figure 12. Example of External Alarm Wiring Connections (with DIN Rail Power Supply) 11. VERIFY NORMAL OPERATION. Step 1: Step 2: Verify that fans are operational. Refer to status LEDs on the inside of the cabinet door and verify that all show green. Figure 13. Cabinet Status LEDs Quick Installation Sheet CMA-437-AEN Page 9

NOTES Quick Installation Sheet CMA-437-AEN Page 10

NOTES Quick Installation Sheet CMA-437-AEN Page 11

NOTES LLC PO Box 489 Hickory, NC 28603-0489 USA 800-743-2675 FAX: 828-325-5060 International: +1-828-901-5000 www.corning.com/opcomm reserves the right to improve, enhance, and modify the features and specifications of products without prior notification. A complete listing of the trademarks of is available at www.corning.com/opcomm/trademarks. All other trademarks are the properties of their respective owners. is ISO 9001 certified. 2015, 2017. All rights reserved. CMA-437-AEN / August 2017 P/N 709C01802 Rev A00