Installation manual AUTOMATIC BACKUP UNIT

Similar documents
Installation Manual Retrofitting of the Option "Noise Reduction" SUNNY CENTRAL of the CP XT Series and SUNNY CENTRAL STORAGE

Installation Manual AUTOMATIC BACKUP UNIT

System description SMA FLEXIBLE STORAGE SYSTEM

Installation Manual 485 Data Module Type B

Installation Manual SMA POWER CONTROL MODULE

Installation Manual 485 Data Module Type B

Service Manual for Installers SUNNY TRIPOWER 5000TL/6000TL/7000TL/8000TL/9000TL/ 10000TL/12000TL

Multi-Function Interface MULTI-FUNCTION RELAY

System Description SMA FLEXIBLE STORAGE SYSTEM in the United Kingdom

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Operating Manual SUNNY BOY 3600 / 5000 SMART ENERGY BATTERY PACK SMART ENERGY

Micro Inverter with Communication Unit SUNNY BOY 240-US SUNNY MULTIGATE-US

Operating Manual NA-BOX 12

Accessories for power generation plants in Italy SMA GRID GATE

System description Off-Grid Systems with SUNNY ISLAND 4.4M / 6.0H / 8.0H

Installation Manual SUNNY CENTRAL 500CP XT/630CP XT/720CP XT/ 760CP XT/800CP XT/850CP XT/900CP XT/1000CP XT

System description Multicluster Systems with Stand-Alone Grid or Increased Self-Consumption and Battery-Backup Function

Service manual SUNNY TRIPOWER 5000TL / 6000TL / 7000TL / 8000TL / 9000TL

Service Manual SUNNY BOY 1300TL/1600TL/2100TL

PV Inverter SUNNY MINI CENTRAL 9000TL / 10000TL / 11000TL with Reactive Power Control

PV Inverter SUNNY BOY 3300/3800

System Monitoring SCHOOLMETERBOX AU

System Description SMA FLEXIBLE STORAGE SYSTEM with BatteryBackup Function

Operating Manual SUNNY TRIPOWER 15000TL / 20000TL / 25000TL

Operating Manual SUNNY BOY STORAGE 2.5

Operating Manual SUNNY ISLAND 3.0M / 4.4M / 6.0H / 8.0H SUNNY REMOTE CONTROL. SI30M-44M-60H-80H-BE-en-33 Version 3.3 SUNNY REMOTE CONTROL

Sunny Boy Accessories SUNNY BOY COMBINER BOX TLUS SBCBTL6

System Manual MEDIUM VOLTAGE STATION 600 / 1200 / 1800 for SUNNY TRIPOWER 60

PV Inverter SUNNY BOY 3300/3800

My Reserve 500 Install Guide

Accessories for Stand-alone inverter SUNNY ISLAND GENMAN

User Manual SMA FUEL SAVE CONTROLLER 2.0

Wind Power Inverter WINDY BOY 3600TL / 5000TL

Wind Power Inverter WINDY BOY 5000A/6000A

Central Inverter SUNNY CENTRAL 500CP-JP / 500CP XT / 630CP XT / 720CP XT / 760CP XT / 800CP XT / 850CP XT / 900 CP XT

Wind Power Inverter WINDY BOY 1200/1700

INSTALLATION MANUAL. Automatic Transfer Switch Battery Backup Distribution. FLEXIBLE STORAGE within Battery Backup Function

Installation Manual SMA SPEEDWIRE/WEBCONNECT DATA MODULE

Central Inverter SUNNY CENTRAL 500HE-20/630HE-20/720HE-20/ 760HE-20/800HE-20

Solar Inverter SUNNY BOY 5000US / 6000US / 7000US

Automatic Transfer Switch Battery Backup Distribution

Installation Manual SMA SPEEDWIRE/WEBCONNECT DATA MODULE

PV inverter SUNNY MINI CENTRAL 7000HV

Galaxy VM. Battery Breaker Box Installation 09/

SUNNY TRIPOWER 12000TL-US / 15000TL-US / 20000TL-US / 24000TL-US / 30000TL-US

User Manual. Solar Charge Controller 3KW

Off-Grid Inverter SUNNY ISLAND 4548-US/6048-US

Installation - Quick Reference Guide Off-Grid Systems

BYD Battery-Box HV User Manual Battery-Box H 5.1/6.4/7.7/9.0/10.2/11.5

User Manual SMA FUEL SAVE CONTROLLER 2.0

Technical Information Control of the Active Power Feed-In at the Grid-Connection Point with the SMA CLUSTER CONTROLLER

BYD Battery-Box LV User Manual Battery-Box L 3.5/7.0/10.5/14.0

Operating instructions. sonnenprotect for operators. KD-337 Part no Version X00.

DATA SHEET 3PH-Battery-Backup-Distribution for 1x Sunny Island incl. SMA ENERGY METER

Charge controller SUNNY ISLAND CHARGER

User Manual Solar Charge Controller 3KW

Installation Guide SUNNY TRIPOWER 60

Wind Power Inverter WINDY BOY 1100LV

IES GRID FEED-IN LIMITER

nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual

[RENEX] [İstanbul, Ekim 2011]

Instruction Manual. Blink HQ Charger. Charge on. a CarCharging Company

Operating Instructions (Translation)

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

500 / 630 / 720 / 760 / 800 / 850 / 900

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

Technical Information PV Inverters

System Monitoring SUNNY SENSORBOX

SMA Multicluster Technology

PV Inverter SUNNY BOY 2000HF-US / 2500HF-US / 3000HF-US

Installation manual. Modbus Interface DIII EKMBDXA7V1. Installation manual Modbus Interface DIII. English

Wind power inverter WINDY BOY 5000-US/6000-US WINDY BOY 7000-US/8000-US. 1 Notes on this addendum. 1.1 Validity. 1.2 Target group

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

Oil-free piston compressors KK and piston vacuum pumps KV

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

Manual. BlueSolar Grid Inverter 1500 / / / / / 230

Installation manual wall-mounted distributor

AIS and 40 kva 400 V. Site Preparation and Installation Manual

PV inverter SUNNY BOY 2100TL

Installation manual portable distributors

Galaxy VM. Modular Battery Cabinets Installation GVMMODBCW, GVMMODBCN 09/

TOD-BCU-PNUS2. Installation Manual. Connection Box for EIBS16GU2 or EIBS16GU2+ (Storage Battery System) For Installation Company Use

AUTOMOTIVE POWER INVERTERS INSTRUCTIONS. Item #31463, #31464, #31465

KeContact P20. User manual

Galaxy VM. Classic Battery Cabinet Installation GVMCBCWUE, GVMCBC2WUE, GVMCBC2WUF, GVMCBC3WUF 07/2017.

Transportation and Installation Requirements SUNNY CENTRAL 500CP XT/630CP XT/720CP XT/ 760CP XT/800CP XT/850CP XT/900CP XT/1000CP XT

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet.

Electric Vehicle Charging Station

SINAMICS G130. Motor reactors. Operating Instructions 05/2010 SINAMICS

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual

Sunny Central Accessories SUNNY CENTRAL STRING-MONITOR US

Battery Power Inverters

Version: 1.0 Mat.-Nr.: DBUS-WB50-80US

Installation Manual SUNNY TRIPOWER 5000TL / 6000TL / 7000TL / 8000TL / 9000TL

Operating Instruction for Downlights

Rooftop Solar PV System Designers and Installers. Training Curriculum. APEC Secretariat

Ex m Solenoid Operator Type 0519

Enelion Vertica. Installation manual. 22 kw. for the specialists

Transcription:

Installation manual AUTOMATIC BACKUP UNIT ENGLISH SBS-ABU-63-1-AU-10-IA-en-11 Version 1.1

Table of Contents SMA Solar Technology AG Table of Contents 1 Information on this Document... 3 1.1 Validity... 3 1.2 Target Group... 3 1.3 Levels of warning messages... 3 1.4 Symbols in the Document... 3 1.5 Typographies in the document... 4 1.6 Designation in the document... 4 2 Safety... 5 2.1 Intended Use... 5 2.2 Safety Information... 5 3 Scope of Delivery... 7 4 Product Description... 8 5 System Structure... 10 6 Mounting... 12 6.1 Requirements for Mounting... 12 6.2 Mounting the product... 12 7 Electrical Connection... 14 7.1 Overview of the Connection Area... 14 7.2 Inserting the Cables... 15 7.3 Connecting the communication cable of the battery inverter... 15 7.4 Connecting to utility grid and household distribution system... 17 7.5 Connecting the power cables of the inverter... 17 8 Commissioning the battery-backup system... 19 9 Technical Data... 20 10 Contact... 22 2 SBS-ABU-63-1-AU-10-IA-en-11 Installation manual

SMA Solar Technology AG 1 Information on this Document 1 Information on this Document 1.1 Validity This document is valid for: SBS-ABU-63.1-AU-10 (Automatic Backup Unit) 1.2 Target Group The tasks described in this document must only be performed by qualified persons. Qualified persons must have the following skills: Training in how to deal with the dangers and risks associated with installing, repairing and using electrical devices and installations Training in the installation and commissioning of electrical devices and installations Knowledge of all applicable laws, standards and directives Knowledge of and compliance with this document and all safety information 1.3 Levels of warning messages The following levels of warning messages may occur when handling the product. DANGER Indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING Indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE Indicates a situation which, if not avoided, can result in property damage. 1.4 Symbols in the Document Symbol Explanation Information that is important for a specific topic or goal, but is not safety-relevant Example Indicates a requirement for meeting a specific goal Installation manual SBS-ABU-63-1-AU-10-IA-en-11 3

1 Information on this Document SMA Solar Technology AG Symbol Explanation Desired result A problem that might occur 1.5 Typographies in the document Typography Use Example bold Messages Terminals Elements on a user interface Elements to be selected Elements to be entered > Connects several elements to be selected [Button] [Key] Button or key to be selected or pressed 1.6 Designation in the document Complete designation Automatic Backup Unit Connect the insulated conductors to the terminals X703:1 to X703:6. Enter 10 in the field Minutes. Select Settings > Date. Select [Enter]. Designation in this document Backup Unit, automatic transfer switch, product 4 SBS-ABU-63-1-AU-10-IA-en-11 Installation manual

SMA Solar Technology AG 2 Safety 2 Safety 2.1 Intended Use The Backup Unit is an automatic transfer switch. In the event of grid failure, the automatic transfer switch disconnects the PV system, loads and the Sunny Boy Storage from the utility grid and creates a battery-backup grid. The battery-backup grid supplies loads that should continue to be supplied with electricity in the event of grid failure. In the event of grid failure, the Sunny Boy Storage supplies the loads with energy after a short switching time. The PV system supplies additional energy that can be used to supply the loads and charge the battery. The product is certified for use with the following SMA inverters: SBS3.7-10 / SBS5.0-10 Use of the product with inverters of manufacturers other than SMA Solar Technology AG is not permitted. The product is suitable for indoor and outdoor use. The product may only be operated with one of the energy meters approved by SMA Solar Technology AG. An updated list of energy meters approved by SMA Solar Technology AG is available at www.sma-solar.com. The product is not suitable for supplying life-sustaining medical devices. A power outage must not lead to personal injury. All components must remain within their permitted operating ranges and their installation requirements at all times. Use this product only in accordance with the information provided in the enclosed documentation and with the locally applicable standards and directives. Any other application may cause personal injury or property damage. Alterations to the product, e.g. changes or modifications, are only permitted with the express written permission of SMA Solar Technology AG. Unauthorized alterations will void guarantee and warranty claims and in most cases terminate the operating license. SMA Solar Technology AG shall not be held liable for any damage caused by such changes. Any use of the product other than that described in the Intended Use section does not qualify as the intended use. The enclosed documentation is an integral part of this product. Keep the documentation in a convenient place for future reference and observe all instructions contained therein. The type label must remain permanently attached to the product. 2.2 Safety Information This section contains safety information that must be observed at all times when working on or with the product. To prevent personal injury and property damage and to ensure long-term operation of the product, read this section carefully and observe all safety information at all times. Installation manual SBS-ABU-63-1-AU-10-IA-en-11 5

2 Safety SMA Solar Technology AG DANGER Danger to life due to electric shock when live components or cables are touched Touching live parts and cables results in death or lethal injuries due to electric shock. Do not touch non-insulated parts or cables. Disconnect the system from voltage sources and make sure it cannot be reconnected before working on the device. Only disassemble the protective covers, if the product is disconnected from all voltage sources. Observe all safety information on components associated with the product. NOTICE Damage due to sand, dust and moisture ingress Sand, dust and moisture penetration can damage the product and impair its functionality. Only open the product if the humidity is within the thresholds and the environment is free of sand and dust. Do not open the product during a dust storm or precipitation. Close the product in case of interruption of work or after finishing work. The product must only be closed during operation. Close tightly all enclosure openings. Only use the supplied cable glands when inserting cables. 6 SBS-ABU-63-1-AU-10-IA-en-11 Installation manual

SMA Solar Technology AG 3 Scope of Delivery 3 Scope of Delivery A B C D E F G H I J K Figure 1: Components included in the scope of delivery L M N O Position Quantity Designation A 1 Automatic Backup Unit B 1 Switch cabinet key C 4 Wall bracket D 4 Hexagon wood screw E 4 Washer F 4 Screw anchor (10 mm) G 2 Cable gland M32 with counter nut H 3 Cable gland M25 with counter nut I 2 Cable gland M20 with counter nut J 1 Cable support sleeve K 1 Filler plug for cable support sleeve L 1 Sealing plug for cable gland M25 M 1 Sealing plug for cable gland M20 N 1 Warning label O 1 Installation manual Installation manual SBS-ABU-63-1-AU-10-IA-en-11 7

4 Product Description SMA Solar Technology AG 4 Product Description A B C Figure 2: Design of the Product Position A B C Designation Enclosure door Connecting plate Type label The type label clearly identifies the product. The type label must remain permanently attached to the product. You will find the following information on the type label: Device type (Model) Serial number (Serial No. or S/N) Date of manufacture Device-specific characteristics Symbols on the Product and on the Type Label Symbol Explanation Danger to life due to electric shock The product operates at high voltages. Prior to performing any work on the product, disconnect the product from voltage sources. All work on the product must be carried out by qualified persons only. Observe the documentation Observe all documentation supplied with the product. 8 SBS-ABU-63-1-AU-10-IA-en-11 Installation manual

SMA Solar Technology AG 4 Product Description Symbol Explanation CE marking The product complies with the requirements of the applicable EU directives. RCM (Regulatory Compliance Mark) The product complies with the requirements of the applicable Australian standards. Installation manual SBS-ABU-63-1-AU-10-IA-en-11 9

5 System Structure SMA Solar Technology AG 5 System Structure The system consisting of battery inverters, PV inverters and an automatic transfer switch must be set up in accordance with the following schematic diagram. At the same time, the local regulations and standards must be observed. BATTERY 1 BATTERY 2 BATTERY 3 PV GENERATOR + DC-In PE CAN1 + DC-In PE CAN2 + DC-In PE CAN3 SUNNY PORTAL / SUNNY PLACES ROUTER PV INVERTER max. 7.7 kw Power BLACKSTART SWITCH CAN4 RS485 BLACK- START SBSx.x-10 LAN1 LAN2 AC-out L N PE PROTECTICE DEVICE max. 40A SMA BACKUP UNIT CONTROLLER L N PE Battery Inverter L N PE PV Inverter CAN AUTOMATIC TRANSFER SWITCH Q1 U Grid Grid U Loads PE SMA ENERGY METER / SUNNY HOME MANAGER 2.0 PROTECTICE DEVICE with RCD max. 40A Grid L N PE GRID-CONNECTION POINT with energy meter of the electric utility company Loads L N PE HOUSE DISTRIBUTION BOARD WITH PROTECTIVE DEVICES TN system PROTECTICE DEVICE LOAD UTILITY GRID max. 63A DC+ cable DC cable Line conductor Neutral conductor Grounding conductor CAN Speedwire/Ethernet Control cable Radio Figure 3: System overview of the battery-backup system with Sunny Boy Storage 10 SBS-ABU-63-1-AU-10-IA-en-11 Installation manual

SMA Solar Technology AG 5 System Structure Delivery of overload and short-circuit current During ramp-up: delivery of overload current for a maximum of one minute Thereafter, the inverter shuts down. During operation: overload current for a maximum of 500 ms. Thereafter, the inverter shuts down. Automatic restart after shutdown: maximum of three reconnect attempts Waiting time between each reconnect attempt: 90 s Measures for guaranteeing the fail-safe operation in the battery inverter Insulation monitoring of the battery voltage Monitoring of the N-PE terminal of the battery inverter Redundant grid disconnection relays in the battery inverter Installation manual SBS-ABU-63-1-AU-10-IA-en-11 11

6 Mounting SMA Solar Technology AG 6 Mounting 6.1 Requirements for Mounting WARNING Danger to life due to fire or explosion Despite careful construction, electrical devices can cause fires. Do not mount the product in areas containing highly flammable materials or gases. Do not mount the product in potentially explosive atmospheres. Requirements for the mounting location The device must be mounted on a stable supporting surface, e.g. concrete or masonry. The mounting location must be suitable for the weight and dimensions of the product (see Section 9, page 20). The mounting location must be freely and safely accessible at all times without the need for any auxiliary equipment (such as scaffolding or lifting platforms). Non-fulfillment of these criteria may restrict servicing. The mounting location must not hinder access to disconnection devices. The mounting location must not be exposed to direct solar irradiation. Direct solar irradiation can cause the product to overheat. Climatic conditions must be met (see Section 9, page 20). The product may only be mounted in a permitted mounting position. 90 Figure 4: Permitted and prohibited mounting positions 6.2 Mounting the product Procedure: 1. Attach the wall bracket to the enclosure. 2. Mark the position of the drill holes and drill the holes (diameter: 10 mm). 12 SBS-ABU-63-1-AU-10-IA-en-11 Installation manual

SMA Solar Technology AG 6 Mounting 3. Attach the product to the wall using the fastening material provided. 4. Ensure that the product is securely in place. Installation manual SBS-ABU-63-1-AU-10-IA-en-11 13

7 Electrical Connection SMA Solar Technology AG 7 Electrical Connection 7.1 Overview of the Connection Area H I G F E D C B A J K Figure 5: Connection areas in the interior of the product Position A B C D E F G H I Designation Terminal blocks Grid for connection to the utility grid Terminal blocks Loads for connection to the household distribution system Terminal blocks Battery Inverter for connecting the battery inverter Terminal blocks PV Inverter for connecting the PV inverter (optional) Circuit breaker for connecting to the utility grid Circuit Breaker for connecting to the household distribution Circuit breaker for connecting the power cable of the battery inverter SMA Backup Unit Controller Jack -X2504 for connecting the communication cable to the battery inverter 14 SBS-ABU-63-1-AU-10-IA-en-11 Installation manual

SMA Solar Technology AG 7 Electrical Connection Position J K Designation Shield connection terminal Shield for the communication cable of the battery inverter Installation location for an energy meter (optional) 7.2 Inserting the Cables Always insert the cables into the product according to the following procedure. NOTICE Property damage due to dust intrusion and moisture penetration Dust intrusion or moisture penetration can damage the product. Protect the product against dust and moisture. Do not open the product at high humidity or high dust levels. Close the enclosure after performing any work on the product. Procedure: 1. Open the product using the switch cabinet key. 2. Unscrew the seven screws of the dead front using a flat-blade screwdriver (blade width: 5 mm to 8 mm) and then remove it. 3. Insert the cable gland from the outside into the enclosure opening and tighten it from the inside with the counter nut. 4. Route the cable into the inverter through the cable gland. If necessary, slightly loosen the swivel nut of the cable gland. 5. Ensure that the amount of conductor inserted is of a sufficient length for the selected terminal block. 6. Tighten the swivel nut of the cable gland. 7.3 Connecting the communication cable of the battery inverter Additionally required material (not included in the scope of delivery): One communication cable between inverter and automatic transfer switch Cable requirements: Twisted pair conductors Cable category: minimum CAT5e Shielding: yes Conductor cross-section: 0.25 mm² to 0.34 mm² Recommended number of conductor pairs: 4 External diameter: 6 mm to 8 mm Installation manual SBS-ABU-63-1-AU-10-IA-en-11 15

7 Electrical Connection SMA Solar Technology AG Maximum cable length between battery and inverter and, in battery-backup systems, between automatic transfer switch and inverter: 10 m UV-resistant for outdoor use. Comply with the requirements of the battery manufacturer. Terminal block Position Assignment A B C D E F A B C D E F Not assigned Enable GND CAN L CAN H +12 V Procedure: 1. Insert the communication cable (see Section 7.2, page 15). 2. Strip the communication cable 130 mm. 3. Trim the cable shield to a length of 20 mm and fold it over the cable sheath. 4. Strip the insulation on the insulated conductors each by 6 mm. The CAN L and CAN H must be a twisted pair. 5. If necessary, trim unused insulated conductors flush with the cable sheath or fold it over the cable sheath. 6. Connect the conductors of the communication cables to the 6-pole terminal block. Pay attention to the assignment of the terminal block and communication connection on the battery inverter and make sure that CAN L and CAN H consist of a pair of conductors. 7. Make sure that the conductors are plugged into the terminal points tightly by pulling slightly on the conductors. 8. Insert the terminal block for the communication connection into the jack X2504 on the Backup Unit Controller. 9. Connect the communication cable with cable shield to the grounding terminal. 10. Ensure that the rotary switches S2101 and S2100 is on position 0. 16 SBS-ABU-63-1-AU-10-IA-en-11 Installation manual

SMA Solar Technology AG 7 Electrical Connection 7.4 Connecting to utility grid and household distribution system Requirements: The connection requirements of the grid operator must be met. The grid voltage must be within the permissible range. Requirements on theac conductors: The maximum permitted temperature for the terminal block of the AC connection of 105 C must be observed. Maximum permissible conductor temperature class: 75 C and 90 C Conductor type: copper wire The conductors must be made of solid wire, stranded wire or fine stranded wire. When using fine stranded wire, bootlace ferrules must be used. Conductor cross-section: 0.5 mm² to 16 mm² Procedure: 1. Insert the cables (see Section 7.2, page 15). 2. Strip off the L, N and PE conductor insulation of the utility grid and the household distribution (see Section 9, page 20). 3. Connect the conductors L, N and PE of the utility grid to the terminal block Grid in accordance with the labeling. Insert and press down the screwdriver into the square-shaped opening of the terminal block. 4. Connect the conductors L, N and PE of the household distribution system to the terminal block Loads in accordance with the labeling. Insert and press down the screwdriver into the squareshaped opening of the terminal block. 5. Ensure that the conductors sit securely in the terminal point of the terminal block. 7.5 Connecting the power cables of the inverter Requirements on the AC conductors: Maximum permissible conductor temperature class: 75 C and 90 C Conductor cross-section: 0.5 mm² to 16 mm² Installation manual SBS-ABU-63-1-AU-10-IA-en-11 17

7 Electrical Connection SMA Solar Technology AG Conductor type: copper wire The conductors must be made of solid wire, stranded wire or fine stranded wire. When using fine stranded wire, bootlace ferrules must be used. Procedure: 1. Insert the inverter cables (see Section 7.2, page 15). 2. Strip off the conductor insulation of L, N and PE by 18 mm. 3. Connect the conductors L, N and PE of the battery inverter to the terminal blocks Battery Inverter. Insert and press down the screwdriver into the square-shaped opening of the terminal block. 4. Connect the conductors L, N and PE of the PV inverter to the terminal blocks PV Inverter. Insert and press down the screwdriver into the square-shaped opening of the terminal block. 5. Ensure that the conductors sit securely in the terminal point of the terminal block. 18 SBS-ABU-63-1-AU-10-IA-en-11 Installation manual

SMA Solar Technology AG 8 Commissioning the battery-backup system 8 Commissioning the battery-backup system 1. Attach the provided warning label with the information about the installed battery-backup system to the AC main distribution board. 2. Make sure that the product is correctly mounted and connected. 3. Insert the dead front and tighten the four screws using a flat-blade screwdriver (blade width: 5 Nm to 8 mm). 4. Lock up the product using the switch cabinet key. 5. Switch on the AC circuit breaker of the battery inverter and the PV system. 6. Commission the inverters (see inverter manual). 7. Configure the battery-backup system via the user interface of the battery inverter: Activate the battery inverter user interface. Log in as Installer. Start the installation assistant. Select [Start the installation assistant] in the context menu. Select [Save and next] up to the step Configure battery-backup system. 8. Carry out communication test. Installation manual SBS-ABU-63-1-AU-10-IA-en-11 19

9 Technical Data SMA Solar Technology AG 9 Technical Data Connection to utility grid and household distribution Rated grid voltage 230 V (240 V) Rated power frequency Maximum input and output current Maximum overcurrent protection of the upstream fuse or circuit breaker External diameter of AC cables Conductor cross-section Clamping range of terminals X1 and X2 Insulation stripping length L/N/PE Sheath stripping length Connection of battery inverters and PV battery inverters Maximum overcurrent protection of circuit breaker of battery inverter External diameter of the power cable Conductor cross-section Clamping range of terminals X3 and X4 Insulation stripping length L/N/PE Sheath stripping length 50 Hz 63 A 63 A 13 mm to 18 mm 0.5 mm² to 16 mm² 0.75 mm² to 16 mm² 18 mm 80 mm 40 A 9 mm to 18 mm 0.5 mm² to 16 mm² 0.75 mm² to 16 mm² 18 mm 80 mm General data Width x height x depth Weight without packaging Operating temperature range Degree of protection Grid configurations Approvals and national standards, as per 03/2018 400 mm x 500 mm x 155 mm approx. 15 kg -25 C to +50 C IP65 230 V (240 V) / TN grid CE, RCM Battery-backup system SBS3.7-10 SBS5.0-10 SBS6.0-10 Maximum overload current (root-mean-square value) 20 A 28 A 32 A Maximum residual output current (< 200 µs) 198 A 198 A 198 A 20 SBS-ABU-63-1-AU-10-IA-en-11 Installation manual

SMA Solar Technology AG 9 Technical Data Voltage against ground potential during delivery of short-circuit current Transient current load of the grounding conductor of the stand-alone grid (5s) Permanent current load of the ground conductor of the stand-alone grid Interval until deactivation when exceeding overload current Interval until deactivation when exceeding 55 A peak (short circuit) SBS3.7-10 SBS5.0-10 SBS6.0-10 < 20 V < 20 V < 20 V 240 A 240 A 240 A 63 A 63 A 63 A 80 ms 80 ms 80 ms 250 µs 250 µs 250 µs Installation manual SBS-ABU-63-1-AU-10-IA-en-11 21

10 Contact SMA Solar Technology AG 10 Contact If you have technical problems with our products, please contact the SMA Service Line. The following data is required in order to provide you with the necessary assistance: Device type Serial number Deutschland Österreich Schweiz France España Portugal SMA Solar Technology AG Niestetal Sunny Boy, Sunny Mini Central, Sunny Tripower: +49 561 9522 1499 Monitoring Systems (Kommunikationsprodukte): +49 561 9522 2499 Fuel Save Controller (PV-Diesel-Hybridsysteme): +49 561 9522-3199 Sunny Island, Sunny Boy Storage, Sunny Backup: +49 561 9522-399 Sunny Central, Sunny Central Storage: +49 561 9522-299 SMA Online Service Center: www.sma-service.com SMA France S.A.S. Lyon +33 472 22 97 00 SMA Online Service Center : www.sma-service.com SMA Ibérica Tecnología Solar, S.L.U. Barcelona +34 935 63 50 99 SMA Online Service Center: www.sma-service.com Belgien Belgique België Luxemburg Luxembourg Nederland Česko Magyarország Slovensko Türkiye Ελλάδα Κύπρος United Kingdom SMA Benelux BVBA/SPRL Mechelen +32 15 286 730 SMA Online Service Center: www.sma-service.com SMA Service Partner TERMS a.s. +420 387 6 85 111 SMA Online Service Center: www.sma-service.com SMA Service Partner DEKOM Ltd. Şti. +90 24 22430605 SMA Online Service Center: www.sma-service.com SMA Service Partner AKTOR FM. Αθήνα +30 210 8184550 SMA Online Service Center: www.sma-service.com SMA Solar UK Ltd. Milton Keynes +44 1908 304899 SMA Online Service Center: www.sma-service.com 22 SBS-ABU-63-1-AU-10-IA-en-11 Installation manual

SMA Solar Technology AG 10 Contact Italia United Arab Emirates ไทย SMA Italia S.r.l. Milano +39 02 8934-7299 SMA Online Service Center: www.sma-service.com SMA Middle East LLC Abu Dhabi +971 2234 6177 SMA Online Service Center: www.sma-service.com SMA Solar (Thailand) Co., Ltd. กร งเทพฯ +66 2 670 6999 South Africa SMA Solar Technology South Africa Pty Ltd. Cape Town 08600SUNNY (08600 78669) International: +27 (0)21 826 0600 SMA Online Service Center: www.sma-service.com Other countries International SMA Service Line Niestetal 00800 SMA SERVICE (+800 762 7378423) SMA Online Service Center: www.sma-service.com Australia India 대한민국 Argentina Brasil Chile Perú SMA Australia Pty Ltd. Sydney Toll free for Australia: 1800 SMA AUS (1800 762 287) International: +61 2 9491 4200 SMA Solar India Pvt. Ltd. Mumbai +91 22 61713888 SMA Technology Korea Co., Ltd. 서울 +82-2-520-2666 SMA South America SPA Santiago de Chile +562 2820 2101 Installation manual SBS-ABU-63-1-AU-10-IA-en-11 23

www.sma-solar.com