MSR01. Water heating controller with solar panel support

Similar documents
Industrial Power Supplies

COMPONENTS FOR SOLAR THERMAL SYSTEMS

Rod thermostat with micro switch

COMPONENTS FOR SOLAR THERMAL SYSTEMS

Electronic circuit breaker EBU10-T

Installation & Operation Manual

Automatic Transfer System - ATS

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

MA-4025 Solar Charger Patent pending

HIGH POWER SOLENOID DRIVER 1

201A-9 INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 01/2010

Operating Instructions for Polysulfone Paddle Monitor. Model: PPS-..

CORNERING LIGHTING MODULE CLM02-CAN INSTALLATION MANUAL

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

CTU 02. Thyristor switching module for fast PF compensation. User manual

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S

LBC S102G 8000 W Ethernet CAN bus on request. LBC S101G W CAN bus Ethernet on request

MODEL POWER BATTERY VOLTAGE COMMUNICATION. LBC SxxxG* 8000 W 110 V CAN or Ethernet. LBC SxxxG* W 110 V CAN or Ethernet

Electronic Ballast EVG 2000-T

TRACTION BATTERY CHARGER

Explanation 1 Input External Switch 2 Input Hipot Safety Switch

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

OPERATING MANUAL. Wind / Solar Hybrid - Charge Controller 24V 1000w. i/hcc Charge Controller

Part 2 Functional Description

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

ON/OFF zone valves (PN 16) AMZ 112, AMZ 113

EM DC Multi-Function DC Energy Meter

ChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves

Current Automation Catalogue

Hub-4 / grid parallel - manual

EVG1200W/10A PHplus-R3

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis

M u l t i P o w e r. CM MultiPower. Installation and Operating Manual

General Description. BADICHEQ 3000 (Battery Diagnostic & Charge Equalizing) The compact solution for perfect battery management

Residential Energy Storage System SH 5K

SAVER DSP SERIES. 3-10kVA USER MANUAL

FIREMAN'S MICROPHONE POWER SUPPLY FOR THE VOICE ALARM SYSTEMS 24V

DeltaSol AX. RESOL DeltaSol AX * * Mounting Connection Operation Application examples. manual

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

Functional Safety Plant Safety and Personal Security. SIL 3, PL e

SCCP PWM Charge Controller/Load Manager Owner s Manual

:43 1/13 Victron & BYD B-Box

GFS - New Charging Technology

Operating Instructions Bedienungsanleitung Mode d emploi EWB EWB

PCT-3001 plus. Display LCD

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

Manual. EN Appendix. Lynx Ion BMS 400A / 1000A

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75

Fuse state indicator MEg72. User manual

Air Flow Controller M1compact Type-Summary FKM 130

PV Master OPERATION MANUAL

DC Energy Measurement for EV Charging Stations

Operation Instructions

MCD 200 Series Soft Starters

Technical Data Sheets

Technical Data Sheets

GENERALITIES TECHNICAL FEATURES

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

EVSE Wallbox. datasheet

Logic module. Brief description. Features. Block structure. Data Sheet Page 1/5

SolarMax P series The power package for residential solar plants

1 EASY COMMISSIONING GUIDE FRONIUS PV-SYSTEM CONTROLLER

OPERATIONAL MANUAL EMBC-8025 INTELLIGENT BATTERY CHARGER. Version 1.5

CODE MODEL TYPE PRESS GW 605 T80

Installation Instructions

Enclosed changeover switches Automatic operation ATSE * - Automatic equipment from 40 to 3200 A Integrated products

LDX-C120 Series is a 120 W integrated DIN Rail Battery Charger / DC UPS Power Supplies, suitable for wide variety of industrial applications.

Electro-hydraulic actuators for valves

Remote on/off switch Connector for remote on/off switch available on all models. DIP switch for 50/60Hz selection (48/350 model only)

POWERTRONIX QUASAR 5-40 KVA

Motor Starter Reverse MSR22-FBP

CASE STUDY APPLICATIONS OF THE DC300

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

APPLICATION OF SYSTEM 8

AIR VOLUME TRANSMITTER / CONTROLLER IML

TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT

User Manual Solar Charge Controller 3KW

Digital Time Switches

DC POWER SUPPLY SYSTEMS

TM Intelligent battery charger for Car- System

Installation Manual. Integrated Prepaid Keypad Meters. For HXE34-KP Meters(CT & CTPT Connection) Hexing Electrical Co., Ltd. [2013.

Local Control Network - building controls in perfection

Instruction Manual. Duo-battery Solar Panel Controller EPIP20-DB series For Both 10 and 20 amp. Controllers (for use with solar panels only) + -

Uninterruptible Power Supplies

Technical Data Sheets

Instruction of Solar Charge Controller. User s Manual

Intelligent Lift Control Valve with Electronic Card

EMIU 720W Mini Inverter

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

SD Series Non-Fused Load Switches

ED900. Low energy operator. Customizing Features: Book 3 of 3

SAILMON SYSTEM LOAD CELL BOX MANUAL. Sailmon LoadCellBox Manual V1.0 Page 1

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

3 Uninterruptible Power Systems

:34 1/15 Hub-4 / grid parallel - manual

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Transcription:

MSR01 Water heating controller with solar panel support version 1.4 trading Czech Republic Czech Republic 1

Content 1. Device description...3 2. Device interface...3 2.1. Inputs...3 2.2. Low tariff...3 2.3. Outputs...3 3. Adjustable parameters...3 4. Functions...4 5. Device connection...5 6. Working status and error indication...6 7. Technical features...7 trading Czech Republic Czech Republic 2

1. Device description MSR01 is designed for water heating control in hot water cylinder with immersion heater and solar panel support. The device controls cylinder charging according to actual temperature in solar panel and according to requested temperature in the cylinder. Electrical charging process can be controlled by centralized telecontrol signal. Device has implemented functions, which control cylinder charging optimally according to set conditions. Functions for service, easy start and system component function test are available, too. Device is in the one module design for DIN rail mounting. 2. Device interface 2.1. Inputs To the regulator all needed sensors are delivered. Ts input for temperature sensor of water in solar panel. Tb input for temperature sensor of water in electric boiler. C common terminal of temperature sensors. H input for centralized telecontrol signal (CRC centralized ripple control). A1, A2 device power supply 100 230 VAC. 2.2. Low tariff MSR01 detects low tariff signal sent via network (centralized telecontrol of load). This signal can be used for blocking the cylinder charging by electrical energy during high tariff period. Device will allow cylinder charging by electrical energy only during low tariff period. Important In order to block centralized telecontrol signal (CRC) the connection between the CRC terminal and A2 must be realized. For application where CRC signal is not present it should be done automatically. For application where user wants to have possibility start electric heating even in high tariff is present it should be realized by switch. 2.3. Outputs Output relays are realized by changeover contacts 240 VAC / 16 A. Rs (terminals No.: 15, 18) relay which controls solar pane valve. Rb (terminals No.: 25, 28) relay for switching electrical heating of cylinder. 3. Adjustable parameters Values and functions are set by rotary buttons. tb setting of requested temperature in cylinder. Δt Temperature difference setting between water temperature in solar panel and actual water temperature in cylinder. Solar panel water must have higher set value than water in cylinder, otherwise it is considered that solar panel does not supply needed caloric and MSR01 will prefer charging by electrical energy. tr Recharging time. It is time counted in hours when it is presumed that solar panel will supply caloric again (for example night). If solar panel does not start to supply caloric within this time, electrical energy charging will be used. This value is valid only with appropriate functions. trading Czech Republic Czech Republic 3

4. Functions OFF Device is disconnected. F1 it charges cylinder by solar panel and electrical energy. Heating is automatically switched between the solar panel and electrical energy. F2 it charges cylinder by solar panel and electrical energy. It is expected that after cylinder discharging, solar panel heating will be available and it waits for this for set time tr. Automatic charging with solar panel priority. F3 it charges cylinder by solar panel and electrical energy. It is expected that after cylinder is discharged, solar panel heating will be available and it waits for this for set time tr. Automatic charging with solar panel has priority with ensured minimum water heating in cylinder on temperature 40 C. Setting of requested temperature tb (water temperature in cylinder) has to be higher than 40 C. F4 it charges cylinder by electrical energy only. F5 it charges cylinder by solar panel only. S6 service start of solar panel circuit pump. S7 service start of cylinder electric heating. S8 service test of solar panel sensor. S9 service test of cylinder sensor. Hysteresis for cylinder charging is fixed on 2 C. Charging finishes when tb is reached. It starts again if water temperature in the cylinder decreases under tb - 2 C. Charging from solar panel starts if hysteresis condition for cylinder charging and also following formula: ts > tb + Δt (solar panel temperature is higher than real water temperature in cylinder plus set Δt) are fulfilled. Charging from solar panel stops if hysteresis condition for cylinder charging or formula: ts < tb + Δt/3 (solar panel temperature is less than real water temperature in cylinder increased by one third of set Δt) are not fulfilled. This hysteresis keeps the relay bouncing off at the limit values of measured temperatures. Picture 1 Switching process of water circulating pump for solar panel heating trading Czech Republic Czech Republic 4

5. Device connection Picture 2 Schematic diagram Picture 3 Connection diagram trading Czech Republic Czech Republic 5

6. Working status and error indication Green LED Yellow LED Description ON OFF Rs disconnected HDO low tariff detected ON blink Rs connected, charging by solar panel Rb disconnected HDO tariff detection without usage ON ON Rs disconnected Rb connected, charging by electrical energy HDO low tariff detected blink OFF Rs disconnected HDO high tariff detected blink blink Rs disconnected Rb disconnected tr recharge timing connected HDO tariff detection without usage blink ON Rs disconnected Rb connected, charging by electrical energy HDO high tariff detected Table 1 Device operating states Green LED Yellow LED Description OFF OFF Fatal error OFF blink Temperature sensor error Table 2 Device error states Green LED Yellow LED Description ON OFF Sensor OK OFF ON Short circuit on sensor OFF blink Sensor connection interrupted Table 3 Device error states during the sensor S8, S9 service test trading Czech Republic Czech Republic 6

7. Technical features Parameter Value Supply voltage: 100... 230 VAC Supply terminals: A1, A2 Centralized telecontrol signal terminal: H Power consumption: max. 1,5 VA Supply voltage indication: green LED Operation status indication: yellow, green LED Cylinder temperature setting range: 10... 90 C Temperature difference setting range: 5... 15 C Recharging time setting: 8... 17 hours Output parameters: Number and type of contacts: 2 x switching contact Nominal current: 16 A Switching power: max. AC 4000 VA Trigger current: 30 A Nominal voltage / max. switching voltage: 250 VAC / 440 VAC Mechanical lifetime: 3 x 10 6 Electrical lifetime: 1 x 10 4 250 VAC, 8 A Others: Working temperature: -20... +55 C Storage temperature: -40... +70 C Working position: any Mounting: IEC 60715 (DIN 35) Protection degree: IP 40 on panel / IP 20 terminals Electrical strength: 4 kv Input wire diameter with / without cavern: max. 2 x 1,5 mm 2 ; 1 x 2,5 mm 2 / max. 2 x 1,5 mm 2 ; 1 x 2,5 mm 2 Weight: 75 g Dimensions: 90 x 18 x 65 mm Standards: IEC 60255-6, IEC 61010 trading Czech Republic Czech Republic 7