Container Fountain Kit with LED Light

Similar documents
Container Fountain Kit

Natural Fiber Planter Fountain

Premium Pond Pump 330 Gallons Per Hour

Submersible Waterfall Pump 1200 Gallons Per Hour

Low-Water Auto Shutoff Pump 420 Gallons Per Hour

Premium Waterfall Pump 1200 Gallons Per Hour

Submersible Pond Pump with UV 800 Gallons Per Hour

Mechanical Filter Pump Kit Up to 500 gallons

Submersible Waterfall Pump 1250 Gallons Per Hour

Mechanical Filter Box Kit

Low-Water Auto Shutoff Pump with Light 300 Gallons Per Hour

Illumifalls Patio Pond

Complete Pond Kit REMINDER CALL BEFORE RETURNING TO STORE. PLEASE CALL BEFORE RETURNING TO THE STORE.

Submersible Waterfall Pump 3600 Gallons Per Hour

Submersible Waterfall Pump 3600 Gallons Per Hour

Illumifalls Kit REMINDER CALL BEFORE RETURNING TO STORE.

Pressurized Pond Filter Up to 850 gallons

Submersible Pond Pump with UV 800 Gallons Per Hour

USE AND CARE GUIDE TIERED POTS FOUNTAIN

USE AND CARE GUIDE TEAL GLAZED POT FOUNTAIN

Installation, Operating and Maintenance instructions for Hydro-Air pumps

AUTOMATIC SUBMERSIBLE UTILITY PUMP

INSTALLATION & OPERATING INSTRUCTIONS: REVOLUTION SPINEBOARD ATTACHMENT WARNING

POST LANTERN ITEM # MODEL #39434 ATTACH YOUR RECEIPT HERE. Serial Number. Purchase Date

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Cleaning & Sanitizing Instructions

5 Gallon Tall Tea Dispenser 3 Gallon Tall Tea Dispenser TALL TEA DISPENSERS. Cleaning & Sanitizing Instructions

SUBMERSIBLE SUMP PUMPS

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

37SCENE 46SCENE 79SCENE

DWS404 DWS524 DWS654 DWS684 DWS694. DWS SERIES INSTALLATION/OWNER'S MANUAL Car Audio Speakers

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English...

SUNC3000 / Item #40885

To assemble your equipment read entire manual and follow all instructions.

GARDEN HOSE UTILITY PUMP

SUBMERSIBLE SUMP PUMPS

POST LANTERN ITEM # MODEL #39487 ATTACH YOUR RECEIPT HERE. Serial Number. Purchase Date

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

SUBMERSIBLE MINI-PUMP

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

OWNER S MANUAL. Submersible Sump Pumps Models: XQS33 (1/3 HP Sump Pump) XQS50 (1/2 HP Sump Pump) Suzhou Xin Qi Electric Co.,ltd

Installation & Operators Manual

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.

Operating Instructions & Parts Manual. Oil Control Gun. Models 48UJ82, 48UJ83, 48UJ84, 48UJ85 and 48UJ86

Read all instructions before installing and using. Installer: This manual must be delivered to the end user.

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

TWO HANDLE LAVATORY FAUCET

OWNER S MANUAL INSTALLATION AND OPERATION INSTRUCTIONS

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

AXS609 AXS612 AXS514 AXS SERIES. INSTALLATION/OWNER'S MANUAL Car Audio

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

PVI 60KW, PVI 82KW, PVI 95KW

MaxLite LED Linear HighBay Fixtures

SUBMERSIBLE POND PUMP

DM1016S INSTALLATION/OWNER'S MANUAL 10" Marine DVC Subwoofer

13101 / / and Installation Instructions

EZR7 Universal 7-Pin Heavy Duty Plug Installation Instructions and Product Warranty Professional Installation Required

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Firstmate Installation Manual and User's Guide May, 2003

11202 INSTALLATION INSTRUCTIONS

RipTide. Brewing Pump. Assembly, Operation, & Maintenance

Installation and Operation Instructions Safety Director Arrow

Series 2100 Operating Instructions

Single-Position Detent Clutch DC Series. (i) MTY (81) MEX (55) QRO (442)

Do not install and/or operate this safety product unless you have read and understand the safety information contained

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

26-GALLON AIR COMPRESSOR Owner s Manual

Terms and Conditions

IMPORTANT INFORMATION PARTS IDENTIFICATION. Assembly Instructions for Model Number 158WEX

Powerful & Intelligent Submersible Pumps

Fission. Nano-Protein Skimmer. Instructions for Model#8100

AEROMOTIVE Part # GM LS1 Fuel Rails INSTALLATION INSTRUCTIONS

PRE-PLUMBED SEWAGE SYSTEM

18660, 18661, & Stealth Fuel Cell INSTALLATION INSTRUCTIONS

ATD Gallon Pressurized Oil Drain Owner s Manual

Drip-n-Gro Dual Top Feed Drip System Instruction Manual

AEROMOTIVE Part # A2000 Fuel Pump Kit INSTALLATION INSTRUCTIONS

User s Manual and Operating Instructions

Nilfisk-CFM SS Vapor Vacuum Instructions for Use and Spare Parts Manual

END USER TERMS OF USE

Limitation of warranties and other warranty terms and state law rights:

ALLEN GROUP INT L INC

AEROMOTIVE Part # Street Rod Fuel Pump System INSTALLATION INSTRUCTIONS

Woolich Racing. Bike Harness Installation Instructions Suzuki Harness Type 4a GSX1300R (Hayabusa)

TYPE F-YRD. Operator s Manual

Serial Number Purchase Date

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.

AEROMOTIVE Part # Generic EFI Fuel System INSTALLATION INSTRUCTIONS

PR 20/20. WARNING Buyer/User assumes all responsability for safety and proper use not in accordance with the directions and sately labels.

3-LIGHT VANITY BAR ITEM # MODEL #34674 ATTACH YOUR RECEIPT HERE. Serial Number. Purchase Date

8-GALLON AIR COMPRESSOR Owner s Manual

AEROMOTIVE Part # Fuel System Prime Kit INSTALLATION INSTRUCTIONS

User Manual. Posture+ Adjustable Base. For customer service call:

Installation/Fonctionnement/Pièces. Pour plus de renseignements concernant l utilisation, l installation ou l entretien, Composer le 1 (800)

Read and follow all instructions. Safety can only be ensured if the walker is assembled and operated according to these instructions.

PART NUMBER: F-706RLSS REVOLUTION LIFT: SLING-SEAT OPTION

Transcription:

Container Fountain Kit with LED Light REMINDER CALL 1-888-755-6750 BEFORE RETURNING TO STORE. PACKAGE CONTENTS Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-888-755-6750, 8 a.m.-6 p.m., EST, Monday-Friday, or email us at customercare@thepondboss.net. Or visit our website www.thepondboss.net. ITEM #DCFKL Part Description Quantity A Pump with filter and LED light 1 B Extensions 4 C Extension tubes 1 D Waterspray nozzle 1 E Waterbell nozzle insert 1 F Trumpet nozzle insert 1 G Lower fountain head nozzle 1 H Epoxy putty (part A) 1 I Epoxy putty (part B) 1 J Cord holder 1 A E B C H I J D E F G WARNINGS AND CAUTIONS WARNING Risk of electrical shock. This pump is supplied with a grounding conductor and grounding type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle. Do not exceed the voltage shown on the pump. Always disconnect pump from the power source before beginning any maintenance or work on the pump. Inspect cord for damage before installation and/or maintenance. Replace the entire pump assembly if damage is found. Do not remove the grounding pin from the power cord plug. To reduce the risk of electric shock, use only on portable, self-contained fountains no larger than 5 ft. in any dimension.

Risk of electrical shock This pump has not been investigated for use in swimming pools or marine areas. CAUTION This pump has been evaluated for use with water only. Use a proper power source as indicated on the pump label. Keep the cord away from high temperatures or other heat sources. Do not pump heated liquids. Do not let the pump run dry. Pump must be completely submerged for proper operation and cooling. Operate in freshwater only. Avoid heavily chlorinated water and water with high ph levels. Do not lift the pump by its power cord. PREPARATION Before beginning assembly or operation of product, make sure all parts are present. Compare parts with package contents list and diagram above. If any part is missing or damaged, do not attempt to assemble, install or operate the product. Contact customer service for replacement parts. Estimated Assembly Time: 30 minutes Tools required for assembly: container, plastic liner or sealant, drill, 1-1/4 drill bit, silicone caulk, latex gloves. OPERATION INSTRUCTIONS 1. Connect the extension tubes to the pump. Fig. 1 Fig. 1 2. Choose a fountain head for the desired water effect, and assemble your choice as shown in Fig. 2. E F D G G C C C Fig. 2

3. Choose a container for your fountain kit. Fig. 3 Fig. 3 4. If the container is not already watertight, use a plastic liner. Or if a clay pot is used, spray the inside of the pot with a clear acrylic sealant. Be sure to use a sealant that is safe for clay pots. Wait 24 hours for the sealant to dry before filling the container with water. Fig. 4 Liner Fig. 4 5. Test fit the assembled container fountain kit in the container. For installing the fountain with the pump cord over the side of the container (recommended), proceed to step 9. For having the pump cord comes out through the container wall, proceed to the next step. Fig. 5 Cord Fig. 5 6. Select a spot on the container wall that is the least visible from normal viewing for the cord exit. Drill a hole in appropriate 1 1/4 in. diameter. Fig. 6 NOTE: Appropriate safety equipment should be used. Fig. 6

7. Place the pump inside the container and run the cord though the newly drill hole. Seal the hole around the cord with epoxy putty and allow it to harden. Fig. 7 NOTE 1: Wearing gloves when mixing the putty is recommended. NOTE 2: For best adhesion, clean and roughen bond area. NOTE 3: Cut off required epoxy putty. Twist and knead until a uniform color is achieved (no streaks). Apply to the hole around the cord. Working time is 15 minutes until hardening begins. After approximately 1.5 hours the epoxy putty will fully harden. 8. Test fit the assembled container fountain kit in the container. Fill the container with water, 2/3 up to the top. Fig. 8 Epoxy Putty Epoxy Putty Fig. 7 9. If needed, attach the extensions to the bottom of the filter box. Fig. 9 Fig. 8 10. Connect the pump to a proper power source. Fig. 10 Fig. 9 GFCI Fig. 10

11. Use the cord holder to tie a loop in the cord. This will help the pump stay in place. Fig. 11 Fig. 11 MAINTENANCE PROCEDURE 1. Unplug the pump, and remove it from the container. Fig. 12 Fig. 12 2. Remove the fountain head and extension tube. Turn over the filter box assembly. Open the filter housing by pushing on the sides of the housing. As you press on the sides of the filter housing, the top and bottom will unlock. Fig. 13 Fig. 13 3. Pull off the cover and remove the filter pad. Rinse the filter pad to remove any debris. Fig. 14 Fig. 14

4. Disassemble the pump and clean the internals of the pump. Fig. 15 Fig. 15 5. Reassemble the pump and filter box kit. Fig. 16 Fig. 16 CARE AND MAINTENANCE Regular cleaning of the pump may be necessary depending upon the environment in which it is operated. Clean the pump when it is visibly soiled or when a drop in performance is detected. Before cleaning, always disconnect the pump from the power source. Remove all parts from the pump and clean in warm, soapy water. Disassemble the front cover and remove the impeller cover to expose the impeller assembly. Use a soft cloth or brush to clean the impeller assembly and the inside of the impeller housing. Refer to the diagram in the replacement parts list. TROUBLESHOOTING If the pump fails to operate: Check to make sure the power cord is plugged in and the pump is getting power. Check the pump outlet and any tubing, fountains, spitters etc. for kinks or obstructions. Remove the inlet screen and/or front cover, and impeller cover to expose the impeller. Turn the impeller to ensure that it is not broken or jammed. If the performance of the pump is not satisfactory or the pump does not flow evenly: Check to make sure the pump is completely submerged in water. Check to make sure the impeller and the impeller housing are clean.

REPLACEMENT PARTS LIST For replacement parts, call our customer service department at 1-888-755-6750, 8 a.m.-6 p.m., EST, Monday- Friday, or email us at customercare@thepondboss.net. Part B C D E F G H I J K L M N O P Description Extensions Extension tubes Waterspray nozzle Waterbell nozzle insert Trumpet nozzle insert lower fountain head nozzle Filter cover Pump with LED light Base plate Filter block Impeller cover O-ring Shaft support Shaft Impeller assembly H J I K C B D E F G P N O M N L Printed in China

LIMITED WARRANTY All pumps and electrical products are warranted to the user against defective material and workmanship, under normal working conditions. This warranty period begins on the date of purchase by the original purchaser. Unless otherwise specified all pond boss electrical products are warranted to the user against defective material and workmanship, under normal working conditions for 1 year from the date of purchase. Pond and Waterfall pumps are warranted for 3 years. All pond boss liners are warranted to the user against defective workmanship, under normal working conditions for 20 years from the date of purchase. All other pond boss products are warranted to the user against defective material and workmanship, under normal working conditions for 90 days. Application Warranty covers only properly installed and maintained units. Any damage to the cord or modification to the unit will invalidate the warranty. Pump warranty is limited to applications pumping fresh water in a pond or fountain only. Other liquid applications or extreme temperature uses must be approved in writing by the manufacturer. Receipt and product date code are required for warranty claims. Warranty Claim Warranty claims must be made by calling customer service (at 1-888-755-6750). If the item is determined to be defective, you will be given authorization to return the defective part(s), freight pre-paid, along with proof of purchase. Disposition The manufacturer will make a good faith effort for prompt disposition regarding all warranty claims. Returned product will be inspected to determine cause of failure before warranty is applied. Warranty does not cover any costs associated with the shipping, handling, installation or removal of products or parts subject to this warranty. For products damaged in transit, a claim should be filed with the carrier. Disclaimer Any oral statements made about the product by the seller, the manufacturer, the representatives, or any other parties do not constitute warranties, should not be relied upon by the user, and are not part of the contract for sale. The seller s and manufacturer s only obligation, and buyer s only remedy shall be for the manufacturer to either replace and/or repair at the manufacturer s sole discretion, the product as described above. Neither seller nor the manufacturer shall be liable for injury, loss or damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss arising from any cause whatsoever, no matter whether based upon warranty, contract, negligence or other misuse, and the buyer and user agree that no other remedy shall be available to them. Before using, the buyer and user shall determine the suitability of the product for the intended use, and assume all risk and liability whatsoever in connection therewith. The warranty and remedy described in this limited warranty is an exclusive warranty and remedy in lieu of any other warranty or remedy expressed or implied. All other warranties and remedies are hereby expressly excluded, including but not limited to any implied warranty of merchantability of fitness for any particular purpose. This warranty gives the buyer and user specific legal rights, and buyer and user may also have other rights which vary from state to state. Some states do not allow exclusions or limitations of incidental or consequential damages, so the above limitations or exclusions may not apply to you. REMINDER CALL 1-888-755-6750 BEFORE RETURNING TO STORE.