Report of Test LLIA000901 008B Integrating Sphere Report Performance Summary Voltage Current Power Frequency Power Factor Current THD Total Luminous Flux Efficacy Chromaticity (x,y) (u',v') Duv CCT CRI (Ra) R9 TM 30: Rf TM 30: Rg 120.0 Vac 0.6072 A 71.74 W 59.97 Hz 0.984 12.4 % 4399.0 lm 61.3 lm/w (0.4385, 0.4011) (0.2529, 0.5204) 0.0014 2948 K 70 91 102 Prepared For: Lumetta, Inc 33 Minnesota Avenue Warwick, RI 02888, USA Test date: 12/28/2017 Signed: Page 1 of 7 Report date: 01/12/2018 Page 1 of 7
0.9 0.8 CIE 11 (x, y) Diagram 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 Page 2 of 7 Page 2 of 7
0.5 CIE 11 (x, y) Diagram 0.45 0.4 0.35 0.3 0.25 0.3 0.35 0.4 0.45 0.5 Page 3 of 7 Page 3 of 7
Spectral Data Total Radiant Flux Total Luminous Flux 16.55 W 4399.0 Lm Chromaticity CIE 11 (x, y) (0.4385, 0.4011) Chromaticity CIE 1976 (u', v') (0.2529, 0.5204) Correlated Color Temperature (CCT) 2948 K Color Rendering Index (Ra) R1 94 R2 95 R3 94 R4 R5 R6 R7 94 R8 87 R9 70 R10 86 R11 R12 82 R13 94 R14 95 TM 30: Rf TM 30: Rg 91 102 Distance from Planckian Locus (Duv) 0.0014 Scotopic/Photopic Ratio * 1.369 Electrical Data Voltage Current Power Frequency Power Factor 120.0 Vac 0.6072 A 71.74 W 59.97 Hz 0.984 Current THD 12.4 % Page 4 of 7 Page 4 of 7
Spectral Power (mw) 380 385 390 395 400 405 410 415 420 425 430 435 440 445 450 455 460 465 470 475 Summary Spectral Power Distribution (wavelength nm, spectral power mw) 0.0015 480 0.017782 580 0.068360 680 0.054019 0.018372 0.020346 0.023407 0.027453 0.031858 0.070731 0.073402 0.076274 0.079267 0.082384 685 690 695 700 0.049152 0.044349 0.039767 0.035598 0.031523 0.036040 0.002192 0.002918 0.004643 0.009044 0.018263 0.028888 0.021232 0.013895 0.010529 0.010079 0.012401 0.016599 0.024790 0.036863 0.042616 0.034662 0.027092 0.023401 0.019681 485 490 495 500 505 510 515 520 525 530 535 540 545 550 555 560 565 570 575 0.040015 0.043625 0.046836 0.049869 0.052264 0.0546 0.056685 0.058418 0.060101 0.061516 0.063094 0.064628 0.066499 585 590 595 600 605 610 615 620 625 630 635 640 645 650 655 660 665 670 675 0.085163 0.087225 0.088617 0.089267 0.089074 0.088184 0.086540 0.084235 0.081158 0.077583 0.073529 0.068824 0.063825 0.058907 705 710 715 720 725 730 735 740 745 750 755 760 765 770 775 780 0.027824 0.024596 0.021536 0.018714 0.016300 0.014047 0.012070 0.010454 0.009144 0.007928 0.006858 0.005909 0.005062 0.004343 0.003733 0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 0.01 0 380 400 420 440 460 480 500 520 540 560 580 600 620 640 660 680 700 720 740 760 780 Wavelength (nm) Page 5 of 7 Page 5 of 7
IES TM 30 Summary Page 6 of 7 Page 6 of 7
Test Equipment Configuration: Test Temperature: Test Procedure: LightLab International Allentown 2m Integrating Sphere Measurements acquired using a Labsphere CDS 2600 spectroradiometer Testing was performed using 4π geometry 25.5 C Tested in accordance with the applicable sections of: LM 79 08, LM 78 07, LM 58 13, ANSI_ANSLG C78.377 2015, ANSI C82 77 10:2014, TM 30 15 Significance: Notes: The laboratory has not participated in the selection of samples to be tested. All testing is performed on the understanding that the significance of the report is limited to the extent that the test sample is representative of production units. The measurements and other derived quantities contained in this report are based on the absolute data as measured. Prorating the performance of the sample for the use of other component combinations (such as lamp / LED / Ballast / driver), or for use in different environmental conditions than that tested, may produce erroneous results. This report is free of erasures and corrections This report may contain data that are not covered by the NVLAP accreditation. Quantities marked with * are not covered. Page 7 of 7 Sphere Report Template V2 8 Page 7 of 7