PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved

Similar documents
VDE tested single cores according to EN (H05Z-K & H07Z-K) for more demanding requirements

ÖLFLEX CLASSIC 110 H Info Benefits

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V

ÖLFLEX CLASSIC 130 H - halogen-free control cable, HFFR and flexible for various applications, U 0 /U: 300/500V

ÖLFLEX CLASSIC 110 CY

ÖLFLEX CLASSIC 115 CY

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall braid minimises electrical interference Multifunctional application possibilities

VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

PRODUCT INFORMATION. UNITRONIC SPIRAL LiF2Y11Y. Info New: the unscreened spiral cables with small cross section High restoring forces PUR outer sheath

PRODUCT INFORMATION. ÖLFLEX HEAT 180 SiF. Info Flexible fine-wire copper conductor

PRODUCT INFORMATION. ÖLFLEX HEAT 180 SiF

USA: UL-listed (MTW), Canada: CSA (TEW), Europe: <HAR> H07V-K (depending on cross s.), tin-coated strands

PRODUCT INFORMATION H07V-K

PRODUCT INFORMATION MULTI-STANDARD SC 2.1. U.I. Lapp GmbH

SKINTOP ST-M, increased oil-resistant plastic cable gland with variable clamping ranges, permanent vibration protection, for offshore platforms

Power & Control Cable IEC

Data sheet. Connection cable M12 jack straight - free line end 8-pole, X-coded 0.5 m. Illustrations P/N 142M2X20005 EAN

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia

Technical Data Sheet Shielded (CY) PVC Control Cable

Technical Data Sheet Shielded (CY) PVC Control Cable

FR-N1X1G1. Low voltage - Energy, cabling, signalling and control

Cables for Railway Technology

INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS

14 HH EAC/CTP CE RoHS-II conform

Selection table for heat-resistant cables

ENERGY. TECSUN(PV) PV1-F Cables for Photovoltaics

THE WORLD OF LAPP. Products for photovoltaic 2016/17

20 HUBER+SUHNER RADOX SOLAR

SABIX Ultra. Standards: EN EN Cat C or D IEC (halogen-free)

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

ENERGY. TECSUN(PV) PV1 F Cables for Photovoltaics

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY

SKINTOP ST-M, increased oil-resistant plastic cable gland with variable clamping ranges, permanent vibration protection, for offshore platforms

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY

Power & Control Cable IEC

Data sheet Connection line M12 plug straight - RJ45 plug straight 8-pole, X-coded 5.0 m

Power & Control Cable IEC

Data sheet E-DAT Industry patch cord V6 IP67 - RJ m

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING S ULTRA CONTINUOUSLY FLEXIBLE WITH HIGHEST FIRE PROTECTION

Technical attributes

Data sheet. Connection line M12 4-pole D-coded 1.0 m. Illustrations P/N 142M1D11010 EAN Product specification. Page 1/

THE WORLD OF LAPP. Food & Beverage

Data sheet chainflex CF6

Data sheet chainflex CF240

Data sheet Connection line M12-RJ45 4-pole D-coded AWG m

BS 6724 Armoured Power Cables, 600/1000V

Technical Data Sheet Shielded (CY) PVC Control Cable

0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR

Technical data sheet LÜTZE SUPERFLEX PLUS (C) PUR FEEDBACK Encoder cables for Siemens and other systems For highest requirements in drive technology

CAN-Bus cable. CAN-Bus cable Can-Bus / Field-Bus cable for medium to maximum load requirements. chainflex cable. Overview. igus e-chainsystems

Data sheet Connection line M12-RJ45 4-pole D-coded AWG m

Technical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable

Installation cable, PVC insulated. Characteristics Properties Unit. Power cables < 1 kv House wiring cable

TRATOS OIL&GAS NEK606

Data sheet chainflex CF140.UL

MOTOR, SERVO, & FEEDBACK CABLES

Item Description Page. Halogen-free wiring cable with improved fire performance and extended temperature range 300/500 V, CE...

Data sheet chainflex CF210.UL

0.6/1KV FLAME RETARDANT UNARMORED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR CROSS-LINKED POLYETHYLENE (XLPE) IEEE 1580 COLOR CODE 3.

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable

Data sheet chainflex CF310.UL

FTG10OM1-0,6/1KV. 50 N/mm 2 of copper section max for fixed layings

Data sheet chainflex CF881

BlueLine Cables for Shipbuilding

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E

600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC

Technical Data Sheet Unshielded (YY) PVC Control Cable

ENERGY. Solar Cables

Data sheet chainflex CF886

BETAtherm BETAflam High-quality industrial cables

Data sheet chainflex CF5

Item Description Page. Halogen-free single conductor with improved fire performance and extended temperature range 300/500 V, CE...

Conductor: plain wire, fine stranding as per VDE 0295 class 6 from 50 mm² fine stranding according to VDE 0295 class 5

Conductor: Fine-wire strand consisting of bare copper wires (following DIN EN 60228). Mechanically high-quality TPE mixture. (see colour code table)

Data sheet chainflex CF8821

ENERGY. TECWATER EMV-FC S1BC4N8-F 0,6/1 kv. Screened Cable for Water Application

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING.

CF270.UL.D.

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores)

ZHPCG CK0226 POWER CABLE WIRE & CABLE

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI

Data sheet chainflex CF10

Photo: HELUKABEL. Trailing Cables G 1

Approvals (Norm references)

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables

DNV-GL HH CE RoHS-II conform

Power & Control Cables. U o. /U 0.6/1 kv - IEC


PROTOLON(FL)-LWL (N)TSFLCGEWOEU 3,6/6 kv: medium voltage flat reeling cable with fibre-optics

Data sheet chainflex CF886

Data sheet chainflex CF270.UL.D

Electrical connection systems

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue

Data sheet chainflex CFSOFT1

INFORMATION. Hybrid cables. Description

RFOU 0.6/1kV Power Cable

Data sheet chainflex CF340

Transcription:

Electron beam cross-linked cables for more demanding application requirements - halogen free shielded control cable with GL certificate, special fire performance, IEC 60332-3, suitable for +125 C Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved UV-resistant Temperature-resistant Interference signals Oil-resistant Mechanical resistance Halogen-free Suitable for outdoor use Flame-retardant

Cold-resistant Benefits For safety in areas with high density of people Reduction of flame propagation, density and toxicity of smoke gases in event of fire Minimises damage to buildings and equipment caused by the formation of toxic acid fumes in fires Certified for maritime applications Copper braiding screens the cable against electromagnetic interference Application range For outdoor applications For the wiring and connection of lighting, heating appliances, control cabinets, and distributors in mechanical and plant engineering For use in traffic regulation systems and outdoors Coil winding, electromagnets, pumps, electrical systems Heat treatment plants, pressure die casting, heating and cooling technology Product features Fire behaviour: - Halogen-free (IEC 60754-1) - No corrosive gases (IEC 60754-2) - Low smoke density (IEC 61034-2) - Flame-retardant (IEC 60332-1-2, NF C 32-070 (C1) and NF-F 16-101 (Class C)) - Low toxicity (EN 50305) No flame-propagation according to IEC 60332-3-22, IEC 60332-3-24 and IEC 60332-3-25 (Flame spread on vertical cable bundle) Oil-resistant acc. IEC 60227-1 (ST9) and EN 50264-1 (EM104) UV-resistant according to ISO 4892-2 Ozone-resistant according to EN 50396 Norm references / Approvals GL - Germanischer Lloyd approved Based on EN 50525-3-21 and EN 50525-3-41 Product Make-up Fine-wire, tinned-copper conductor Electron beam cross-linked polyolefin copolymer insulation Cores twisted in layers Tinned-copper braiding Outer sheath: electron beam cross-linked polyolefin copolymer, black Technical Data Classification ETIM 5: Classification ETIM 6: Core identification code: ETIM 5.0 Class-ID: EC000104 ETIM 5.0 Class-Description: Control cable ETIM 6.0 Class-ID: EC000104 ETIM 6.0 Class-Description: Control cable Colour-coded according to VDE 0293-308, refer to Appendix T9

Specific insulation resistance: or black with white numbers refer to article table >2 TOhm x cm Conductor stranding: Fine wire according to VDE 0295, class 5/IEC 60228 class 5 Minimum bending radius: Nominal voltage: Test voltage: Protective conductor: Occasional flexing: 15 x outer diameter Fixed installation: 5 x outer diameter Up to 1.0mm² U0/U 300/500 V From 1.5mm² U0/U 450/750 V 0.6/1kV from 1.5 mm² in the case of fixed and protected installation C/C 4000 V, C/S 2500 V G = with GN-YE protective conductor X = without protective conductor Temperature range: Occasional flexing: -35 C to +120 C Fixed installation: -55 C to +125 C Temporary (3.000h): up to +145 C Note Unless specified otherwise, the shown product values are nominal values. Detailed values (e.g. tolerances) are available upon request. Copper price basis: EUR 150/100 kg. Refer to catalogue appendix T17 for the definition and calculation of copper-related surcharges. Please find our standard lengths at: www.lappkabel.de/en/cable-standardlengths Packaging size: coil 30 kg or 250 m, otherwise drum Please specify the preferred type of packaging (e.g. 1 x 500 m drum or 5 x 100 m coils). Photographs and graphics are not to scale and do not represent detailed images of the respective products. Prices are net prices without VAT and surcharges. Sale to business customers only.

Powered by TCPDF (www.tcpdf.org) Article number Number of cores and mm² per conductor 300/500 V - colour-coded Outer diameter [mm] Copper index (kg/km) Weight (kg/km) 1024400 2 X 0.5 6.8 41 45 1024401 3 G 0.5 7.1 45.5 59 1024407 2 X 0.75 7.2 46 79 1024408 3 G 0.75 7.6 57.9 96 1024409 4 G 0.75 8.4 64 116 1024410 5 G 0.75 9.1 77.4 139 1024415 2 X 1.0 7.4 56 90 1024416 3 G 1.0 8 65.3 104 1024417 4 G 1.0 8.6 78.1 129 1024418 5 G 1.0 9.6 89.4 153 450/750 V - colour-coded 1024423 2 X 1.5 8.6 65 114 1024424 3 G 1.5 9.1 83 132 1024425 4 G 1.5 10 100 163 1024426 5 G 1.5 11.1 125 200 1024433 2 X 2.5 10 112 157 1024434 3 G 2.5 10.7 146 198 1024435 4 G 2.5 11.6 167 236 1024436 5 G 2.5 12.9 200 287 1024441 4 G 4.0 13.7 237 317 1024446 4 G 6.0 15.1 318 404 1024451 4 G 10.0 19.3 558 669 300/500 V - Black with white numbers 1024480 2 X 0.75 7.2 46 79 1024481 3 X 0.75 7.6 57.9 96 1024482 4 X 0.75 8.4 64 116 1024411 7 G 0.75 10 102 186 1024483 7 X 0.75 10 102 186 1024412 12 G 0.75 13.4 177 219 1024484 2 X 1.0 7.4 56 90 1024485 3 X 1.0 8 65.3 104 1024419 7 G 1.0 10.3 113.3 211 1024420 12 G 1.0 14 188.1 266 PRODUCT INFORMATION

Powered by TCPDF (www.tcpdf.org) Powered by TCPDF (www.tcpdf.org) Article number Number of cores and mm² per conductor 450/750 V - Black with white numbers Outer diameter [mm] Copper index (kg/km) Weight (kg/km) 1024486 2 X 1.5 8.6 65 114 1024487 4 X 1.5 10 100 163 1024427 7 G 1.5 12 149 273 1024488 7 X 1.5 12 149 273 1024428 12 G 1.5 16.3 280 371 1024489 3 X 2.5 10.7 146 198 1024490 4 X 2.5 11.6 167 236 1024437 7 G 2.5 14.4 288 385 1024438 12 G 2.5 19.3 477.3 569 PRODUCT INFORMATION