Neptune X6 12/24V SAE 316L Stainless Steel Low Profile Through-Hull Mounted Underwater LED Light Manual

Similar documents
Dr. LED: Dynamic Engineering Inc. d.b.a. Dr. LED US Federal Government CAGE Code: 636L3

Single Colour Light. TIX202 Interchangeable Flush Fit Thru-Hull Light. Installation and Operation Guide. Rev

The Dr. LED Story. How to contact Dr. LED:

The Dr. LED Story. How to contact Dr. LED:

Level One Electric Vehicle Charging Station FREE STANDING Product Guide

18 LED Thru-Hull SeaLite

Single Colour Light. TIX301 Interchangeable Flush Fit Thru-Hull Light. Installation and Operation Guide

SV10 LED. The US manufactured SV10 LED is. SV10 LED technical specifications

INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1107

Dyna Flood SO / HO. User guide

Dodge Ram 5.9L Cummins LOW FUEL PRESSURE ALARM LIGHT - Installation Manual -

SV14 technical specifications

37SCENE 46SCENE 79SCENE

Deluxe ASA Halogen Spot/Flood Light

Twin-Beam Spotlight 3,000,000 Power Series Corded Cordless Rechargeable

SOLAR PILING LITE 8 SOLAR PILING LITES. Lumens MODEL: LL-SPL-8-X-X. Phone: Fax:

ODY-17-1 DIGITAL COMPASS DISPLAY

TIX402 EOS Installation and Operating Guide

Serial Number Purchase Date

Installation and Operation Instructions Safety Director Arrow

Level One Electric Vehicle Charging Station Wall Mount Product Guide

SV38-250w. SV38 technical specifications

Installation and Operation Manual

IMPORTANT SAFETY INSTRUCTIONS

BEAMER MODEL VDC Spotlight with joystick control panel MODEL VDC Spot/flood light with joystick control panel

FOR ALL SINGLE MOTOR UNITS INSTALLATION AND OPERATING INSTRUCTIONS REV 12/15 89

SUNTURA SOLAR TRACKER

Air Curtain. Installation, Operating and Maintenance Instructions

M20 Warrior Tactical LED Flashlight

Part Number cc/min Water/Methanol Injection Flow Gauge

Spotlight 1,000,000 Power Series Cordless Rechargeable

CLEAN POWER TM CPS Series Operator s Manual

INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1032

ODY-19-1 AIR PRESSURE GAUGE

HARDWARE KIT INSTALLATION GLOVES

Internal PVC Rod-Style Fluid Level Sensor


Microscope light manual

Premium Supply. Tilt Deck. Models PCK-TD PCK-PTD CTD-310-K. Operator s Manual and Installation Instructions

- INSTALLATION INSTRUCTIONS -

Surface Mount e-lites

ActuLink ABS Module - ABS-MOD-400

Installation Instructions

Premium Supply. Tilt Deck. Models PCK-TD PCK-PTD. Operator s Manual and Installation Instructions

Flex Tube. User guide

Installation & Operation Instructions. Deluxe LED Spot Light

INSTALLATION AND OPERATING INSTRUCTIONS

HI-FLOW FUEL RAIL. Installation Instructions for Scion tc & xb AEM Fuel Rail AN Hose adaptor

Effective June 1, 2013 This guide supersedes all previous versions

RESPA -SD or Gideon HVAC Fresh Air Filtration System Installation Guidelines for John Deere 450J, 550J, 650J, 700J, 750J, 850J Crawlers

ROPE LIGHT ITEM # MODEL #UCL48L. Français p. 8. Español p. 15 ATTACH YOUR RECEIPT HERE. Purchase Date

LIGHTNING PLUS 120 WATT / 6 OUTLET VOLT POWER SUPPLY & STROBE LIGHT KIT 6 Different Light Patterns 8006 SERIES INSTALLATION INSTRUCTIONS

advanced FLOW engineering Instruction Manual P/N: &

ODY-04-1 or ODY-04-2 rev. B WATER TEMPERATURE GAUGE

LT-EL138 LED Flashlight

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

SUNTURA HD SOLAR TRACKER

RIVA YAMAHA GPR MECHANICAL TRIM-TAB SYSTEM PART # (RY2820) APPLICATIONS: GP1200R GP800R NOTICE :

Use and Care Guide. Part # SC SV-OS-BZ SC SV-OS-W Model #

Part# Accessory Power Distribution Module

Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.

Installation Instructions BULL BAR (Part # 51033&51034) SIERRA 1500 / SILVERADO 1500

Swing Arm Magnifying Lamp

Model Beretta Tactical Light. Users Manual. Beretta 1200 PF 12 Gauge Shotgun Protected by US. Patent 4,856,218 Revision D 7_1_97

SOLAR REGULATORY BUOY. Solar Powered Regulatory Buoy. Lumens. Model: LL-SBL-P MODEL: LL-BUOY-P

12 Volt Utility Controller for 4, 6 or 8 Brakes No P

GEN 3 LED LIGHT BAR INSTALLATION MANUAL Model 7840-A 44"

Operating and Installation Instructions

ALUMAREEL. Electrical Cord Reel. Model EC6 100 Model EC Operational, Maintenance and Installation Manual

Model Series. PumpAgents.com - buy pumps and parts online ELECTRIC BILGE PUMPS. Model Series FEATURES SPECIFICATIONS STANDARD MODELS

Use and Care Guide.

ODY-05-2 VOLTMETER FOR REMOTE MONITORING

10 Ch Peak & Hold Injector Driver PN

HD Cross Over Steering System. P/N: (XJ-TJ-ZJ) ( YJ)

SWIM PLATFORM BRACKET

ELECTROSTEER MODEL A FRESHWATER MODEL A SALTWATER

Part Number Analog EGT Gauge

Fig Series. Installation and Spare Parts Manual Pilot House Control Solar-Ray Sealed Beam 7 & 8 Searchlights

HANGING LANTERN ITEM # MODEL #CP199MBK. Français p. 9. Español p. 17 ATTACH YOUR RECEIPT HERE. Serial Number. Purchase Date

UL Ti MATE Range of underwater lights. (click on document required)

Oil Pressure Display Gauges Part numbers: Analog Oil/Fuel SAE Pressure Gauge psi Analog Oil SAE Pressure Gauge.

Model 318FG 618FG. Users Manual. Tactical Light. Remington Gauge Shotgun. Revision A

External Non-Contact Fluid Level Sensor

Installation Instructions / Warranty. Raindance Allrounder 28110XX1 Wall Outlet Adapter with Hose Connection 28108XX1

GDP STREET-GATE 38mm Wastegate System

INVERTER HARNESS INSTALLATION FOR FREIGHTLINER CASCADIA

CRD600 Automatic Fitting Inserter

UV-AIRE AIR PURIFYING SYSTEM

PREMIER, MARINE, & STANDARD

SOLAR DASH CHARGING SYSTEM USER GUIDE

MODELS: SPL-12W, SPL-12B, SPL-12C IMPORTANT! READ THESE INSTRUCTIONS BEFORE INSTALLING AND USING THIS PRODUCT.

advanced FLOW engineering Instruction Manual P/N: /

Installation Instructions Winch Quick Connect Kit Part # (8 ) Part # (24 )

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

MODEL AL ADJUSTABLE ALUMINUM BRACKET DESIGNED FOR AUXILIARY MOTORS UP TO 15HP INSTRUCTION MANUAL

In-Line Linear Actuator

INSTALLATION & OPERATION MANUAL

BEFORE YOU BEGIN LIST OF COMPONENTS. Isopropyl SWITCH SCOTCH-BRITE PAD ALCOHOL PREP PAD SWITCH HARNESS REVOLVER PCM COVER STICKER

Installation & Maintenance of the Fresh-Aire UV Airborne Duct System for Commercial HVAC Systems. Parts Included. Optional Parts

Transcription:

Neptune X6 12/24V SAE 316L Stainless Steel Low Profile Through-Hull Mounted Underwater LED Light Manual Thank you for purchasing Dr. LED s Neptune X6 underwater LED light. This 1500+ lumen Neptune X6 underwater light outperforms all underwater LED lights in the same category in lumens per LED per dollar. Six US made high-power CREE LEDs provide the highest lumen-per-watt underwater light ever made. Features: * Low profile 5mm (~0.2 ) protrusion and small footprint:100mm (~3.9 ) diameter on outer hull. * Replaces (same dimensions) our popular three LED aluminum Neptune Light. * High-intensity white LED light travels farther underwater for maximum visibility and truer colors. * Instant on, no warm-up of bulb needed. * SAE 316L stainless steel unibody design. No anodes required, as housing is corrosion proof. * Long service life, shock proof, ultra-rugged with no filament to burn out or break * Multi-voltage 12VDC or 24VDC. * Serviceable from inside the boat, if needed. * Non-Polarized Connection, Reverse Polarity Protected. * Under-Voltage and Voltage Spike Protected. * Electrically Protected Against RFI/EMC Interference. * Integrated Thermal Management. * Designed in the USA. * Compliance: NMMA, USCG, ISO 8846 & SAE J1171 Ignition Protection ABYC H-27 Side Load Test MIL-STD-810G Vibration & Shock Proof ASTM B117 Salt Spray (Fog) CE, FCC Part 15, RoHS, IP68 Part # Description Volts 9000487 Underwater thru-hull LED light, Cool White 1500+ Lumens 12/24 VDC 9000494 Underwater thru-hull LED light, Blue Light 300+ Lumens 12/24 VDC Specifications: Operating Temperature: -40 to +145 Degree F (withstands temperature extremes). White LED Color Temperature: Cool White 6,000 Degree Kelvin Input Voltage: 12/24 VDC Body, Body End Cap, Cable Gland Nut, & Body Lock Nut: Stainless Steel Lens: Toughened/Heat Treated Glass (10mm thick) Gasket: High Temperature (200 deg. C) Silicone Rubber Light Cable: High Temperature (200 deg. C ) Silicone Rubber Insulated Cable Weight: ~ 2 kg (~4.4 lb) M500-X6 V1.1 Release 201606 DoctorLED.com Page 1/5

Mechanical Installation: Installation must be carried out by a qualified technician. www.doctorled.com Please review drawings on the right and following pages. Please note that the maximum hull thickness shall not exceed 100mm (~3.9 ). Select a mounting location with desired visibility and a stable, sturdy mounting hull surface. The light may be placed up to 3 meters below the waterline. Make sure there is adequate access to the mounting area inside the hull before drilling. Drill a 68mm (~2 11/16 ) diameter hole in the hull (1 = 25.4mm). Make sure the outside surface and the thru-hull surface are clean and dry. Gently unscrew the Body Lock Nut, then remove the Stainless Steel Metal Back-Plate, and Silicone Gasket from the Light Body. Feed the Cable thru and then gently insert the Light Body thru the drilled hull. With a pencil, trace the Lens Bezel outline onto the hull and then gently remove the Light Body. Tape outside the outline to prevent excess sealant from coming into contact with the hull. Apply a generous amount of marine grade sealant to the outside surface and the drilled thru-hull surface. Drawing M500-2 Make sure the Light End Plate and the Cable Gland Nut are tightened as depicted in Drawing M500-1 on page 4. Make sure the underside of the Lens Bezel is clean then apply a generous amount of marine grade sealant to it as depicted in Drawing M500-2 on page 5. Gently insert the Light Body through the cut hull, pressing firmly. Check for a tight seal and wipe off excess sealant inside and outside. From the inside place the Silicon Rubber Gasket onto the Light Body. Then, slide the Stainless Steel Metal Back-Plate against the Rubber Gasket. Loosen the three Hex Bolt Lock Nuts and the three stainless Hex Bolts (expose at least 5 threads) on the large Body Lock Nut. Apply a small amount of grease onto the Light Body threads. Gently screw* the large Body Lock Nut onto the threaded Light Body until one of the Hex Bolts is touching the Metal Back-Plate. Adjust the three Hex Bolts to the contour of the hull then using a Allen wrench tighten them making sure that there is adequate compression of the Gasket for a watertight fit. Finally, using a nut wrench tighten the three Hex Bolt Lock Nuts. *BE VERY CAREFUL NOT TO DAMAGE THE BODY THREADS. (Inside hull curvature is exaggerated.) M500-X6 V1.1 Release 201606 DoctorLED.com Page 2/5

Electrical Wiring and Connections: All wiring must be carried out by a qualified technician. With low voltage DC wiring, the risk of fire may be present if wiring is not correctly installed (if in doubt, ask). It is critical that the wire gauge used be of sufficient size for the current draw. Make sure the correct size fuse is used (3A Slow Blow per light). The electrical connections are not polarized. Maintenance: Ensure the lens is kept clean at all times. Do not use abrasive or sharp objects to clean the glass lens. A plastic or rubber scraper may be used if necessary. Keep the lens clear of paint. Failing to do so will result in poor light performance. Carry out regular checks of the housing to ensure it is kept clear and clean. Carry out regular checks of wiring and connectors to ensure they are secured. Limited Warranty: Dr. LED products are warranted for one year against defects in material and workmanship. Any product developing such defect within this period will be repaired or replaced at our option providing it is sent to us, shipping charges prepaid, along with $20.00 to cover the cost of handling. This is not a repair charge. No additional charge will be made unless the warranty period has expired or servicing is made necessary for reasons beyond our control, in which case a charge will be applied. A Proof-of-purchase date to Dr. LED must accompany the return. This limited warranty does not cover damages to this product through accident or misuse, nor does it cover any incidental expense to the user resulting from a non-function or mal-function of this product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights. You may also have other rights, which vary from state to state. Under no circumstances is Dr. LED responsible for reimbursement of expenses related to vessel haul-outs, technician or yard personnel travel expenses, yacht storage, labor performed during removal and/or replacement of fixture, or expedited shipping costs for replacement parts. These are assumed liabilities of the customer and part of the terms of sale between Dr. LED and its customer. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. Warning or Disclaimer: Electric shock, extreme serious personal injury or death may result if not used or installed properly. Light unit may become HOT upon use. For handling by qualified adults ONLY. For use with rated voltage ONLY. Dr. LED is not responsible for any damage which may arise from improper use or tampering of this product. M500-X6 V1.1 Release 201606 DoctorLED.com Page 3/5

Drawing M500-1 M500-X6 V1.1 Release 201606 DoctorLED.com Page 4/5

Drawing M500-2 M500-X6 V1.1 Release 201606 DoctorLED.com Page 5/5