ZK2.5-D1-PE PI-Spring Terminal Blocks Double deck with 1 ground circuit

Similar documents
ZK4-PE PI-Spring Terminal Blocks Ground

ZK2.5-4P PI-Spring Terminal Blocks Feed-through with 4 connections

ZK6 PI-Spring Terminal Blocks Feed-through

ZK2.5-D-CH PI-Spring Terminal Blocks Component holder

ZK2.5-SP PI-Spring Terminal Blocks Disconnect with plug - with test sockets

ZS50-PE Screw Clamp Terminal Blocks Ground

ZS10-PE Screw Clamp Terminal Blocks Ground

ZK2.5-SF-R PI-Spring Terminal Blocks For 5x20 fuses - with blown fuse indicator

ZS6-3S Screw Clamp Terminal Blocks Feed-through with 3 connections

ZK2.5-PE-4P PI-Spring Terminal Blocks Ground with 4 connections

ZS4-D2-S-T Screw Clamp Terminal Blocks Double deck with 1 disconnect circuit with test socket screws and 1 feed-through circuit

ZS6-D1-PE Screw Clamp Terminal Blocks Double deck with 1 ground circuit

ZS4-PE Screw Clamp Terminal Blocks Ground

ZS35 Screw Clamp Terminal Blocks Feed-through

ZS4-D-CH Screw Clamp Terminal Blocks Component holder

ZS6 Screw Clamp Terminal Blocks Feed-through

ZK2.5-4P PI-Spring Terminal Blocks Feed-through with 4 connections

ZK4-4P PI-Spring Terminal Blocks Feed-through with 4 connections

ZS4-SF Screw Clamp Terminal Blocks For 5 x 20 fuses

ZS4-PE Screw Clamp Terminal Blocks Ground

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

ZS35-PEN Screw Clamp Terminal Blocks Ground + Neutral

ZS4-SF1 Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses

ZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

ZS4 Screw Clamp Terminal Blocks Feed-through

ZS10-S-R2 Screw Clamp Terminal Blocks Disconnect with lever

ZS6-4S Screw Clamp Terminal Blocks Feed-through with 4 connections

ZS4-T3 Screw Clamp Terminal Blocks Triple deck with 3 feed-through circuits

ZS10 Screw Clamp Terminal Blocks Feed-through

ZS10-ST Screw Clamp Terminal Blocks Test disconnect with sliding link

ZS4-S Screw Clamp Terminal Blocks Disconnect with blade

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator

ZS6 Screw Clamp Terminal Blocks Feed-through

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator

ZDP Pluggable Terminal Blocks Feed-through

ZP2.5-PE Spring Terminal Block Ground

ZP2.5-4P Spring Terminal Block Feed-through

DBL distribution blocks 3x1 pole

ZS4-SF1 Screw Clamp Terminal Block

Main catalog. SNK series Terminal blocks. Phone: Fax: Web: -

Main catalogue. SNK Series Terminal Blocks Accessories Marking Solutions

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

Electronic overload relay EF65, EF96 and EF146

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Electronic overload relays EF205 and EF370

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

Thermal overload relay TF140DU and TF140DU-V1000

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

Thermal Overload Relays

Thermal overload relay TF65 and TF96

Mini contactors B6, BC6 with 3 pole

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

Manual motor starter MS116

MS General Information Extended Product Type: MS

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Manual motor starter MS132

Manual motor starter magnetic only MO325

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

Manual motor starter MS116

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

DX³ RCCBs - ID 4P up to 100 A

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Manual motor starter MS132

RX 3 M.C.B A up to 63 A

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

Manual motor starter MS132

RX 3 M.C.B A up to 63 A

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

ABB i-bus KNX DG/S x DALI-Gateway Basic

Brochure. Motor protection and control DRAS enclosed direct-on-line starters

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

TX³ RCCBs 2P up to 100 A

Data sheet. W-Series WDU 4 SL/EN

up to 63 A (1 module per pole)

Voltage limiting device HVL

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

Voltage limiting device HVL

Overloadrelay,10-16A,1N/O+1N/C. Articleno

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

Phase + Neutral, neutral on left side

B Mini Contactor V Hz

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC mm

Data sheet... W-Series WPE 4

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1NQ

Deliveryprogramme. Overloadrelay,24-40A,1N/O+1N/C. Articleno CatalogNo. XTOB040DC1. Auxiliarycontacts. Short-circuitprotection

Transcription:

Technical Datasheet SNK6040D00 Catalogue Page SNK604S00 ZK.-D-PE PI-Spring Terminal Blocks Double deck with ground circuit Improve the safety of your installation in the event of a short-circuit thanks to our screwless rail contact: - Rail contact non operator dependent, - Performances above the requirements of the IEC 6047-7- terminal block standard, - Secured snap on or off the rail, - Profile aligned with ZK.-D. SNK6080V004 SNK0077F0000 3D CAD outline drawings available on "Control Product 3D" portal SNC7006 F0000 PI-Spring Terminal Blocks. mm² AWG Ordering Details Color Green-Yellow Green-Yellow. mm 0.0 in Spacing Type Order Code EAN Code Pack (ing) Weight ( pce) g ZK.-D-PE SNK700R0000 3477007 0.70 Declarations and Certificates CE CB RoHS USR CNR CSA EAC Ex ATEX IECEx USR CNR Haz Loc BV DNV ATEX Declaration

Declarations and Certificates CE CE SND0U0* CB CB SND60A0* RoHS RoHS SND303F0* USR CNR USR CNR SND60A0* SND60A0* CSA CSA SND604A0* EAC Ex EAC Ex ATEX ATEX SND600A7* IECEx IECEx SND600A7* USR CNR Haz Loc BV DNV Atex Declaration USR CNR Haz Loc BV DNV Atex Declaration SND604A0* SND603A0* SND603A0* SND08C0* Explosive Atmosphere: ATEX Classification Group Category IM II GD Ex eb I/IIC/IIIC Protection Method Ex e: increased security In the presence of explosive dust atmosphere, terminal blocks are to be installed in certified enclosure II D General Information The following information must be strictly adhered to in order to guarantee the terminal block electrical, mechanical and environmental performance. Protection Rail Wire stripping length IEC 6047- TH 3-7., TH 3- Denudage IP0 TH 3-7., TH 3- mm 0.433 in NEMA Operating tool Torque Flat screwdriver Screw clamp Flat screwdriver 3. mm 0.38 in Screw rail contact (Maximum value) Disconnect device Material Specifications Insulating material CTI Flammability Polyamide 600 V UL4 V0 NF F 60 IF Connecting capacity per clamp Rigid - Solid / Stranded conductor Flexible conductor Flexible conductor with non insulated ferrule Flexible conductor with insulated ferrule Gauge Ferrule maximum outer diameter or conductor insulation maximum outer diameter Needle flame testec 606-- Compliant PI Spring IEC6047-7- UL0 0.... 4 mm² 6... AWG IEC6047-7- 0..... mm² 0..... mm² 6... 4 AWG 0..... mm² 6... 4 AWG A /.3 mm Dia. IEC 6047- Ferrule 4.6 mm 0.87 in The "Connecting capacity with ferrule" data is guaranteed with ABB crimping tool PS-3 (crimping capacity up to 0 mm²). Technical Datasheet SNK6040D00 ABB

Multi Connecting capacity per clamp Rigid - Solid / Stranded conductors Flexible conductors Flexible conductors with twin ferrule Don't mix solid and flexible conductors in the same clamp Don't mix solid or flexible conductors of different sizes in the same clamp The "Connecting capacity with ferrule" data is guaranteed with ABB crimping tool PS-3 (crimping capacity up to 0 mm²) Cross section Rated cross section IEC6047-7-. mm² UL0 AWG Maximum Cross section 4 mm² AWG Electrical characteristics Current Rated current IEC6047-7- Field and factory wiring Cat. UL 0 Factory wiring Cat. UL 0 CSA-C-. n 8 Maximum Exe current IEC/EN 6007-7 Rated short-time withstand current s (Icw) IEC6047-7- 300 A Short-time withstand current Rated short-circuit withstand current Max. current (4 temperature increase) / Max. cross section (mm²) Maximum short circuit current (s) 0. s s 0 s 30 s min UL 0 36 A 300 A 4 mm² Short Circuit Current Rating (SCCR) SA UL 0 supplement SCCR UL 0 With the following configurations: Suitable conductor wire range Maximum voltage Fuse class / Max. amp. Rating J T RK RK G CC Voltage Rated voltage IEC 6047- Rated voltage UL 0 Use Group UL 0 B, C, D Rated voltage CSA-C-. n 8 Rated voltage Ex e IEC/ EN 6007-7 Rated impulse withstand voltage IEC 6047-8000 V Dielectric test voltage IEC 6047- Pollution degree IEC 6047-3 Overvoltage category IEC 6047- III ABB Technical Datasheet SNK6040D00 3

Temperature range Ambient temperature min/max Storage -... +0 C Installing -... +40 C Service -... +0 C -67... +30 F +3... +04 F -67... +30 F Current Derating curve for continuous service temperature Dissipated power Maximum dissipated power at rated current IEC 6047- Maximum dissipated power at maximum Exe current IEC 6007-7 Rated power dissipation at an ambient temperature of 3 C - IEC 6047-7-3 Separate arrangement / Overload and short-circuit protection Separate arrangement / Exclusive short-circuit protection fuse and 4 feed-through blocks Compound arrangement / Overload and short-circuit protection Compound arrangement / Exclusive short-circuit protection fuse blocks Environmental Characteristics Additional climatic tests Dry heat Cyclic damp heat Cold Damp heat steady state IEC 60068- Compliant Temperature 0 C Duration of test 6 h IEC 60068-30 Compliant Temperature C Relative humidity % Number of cycles ( cycle = 4h) IEC 60068- Compliant Temperature - C Duration of test 6 h IEC 60068--78 Compliant Temperature 40 C Relative humidity 3 % Duration of test 6 h Corrosion Salt mist IEC 60068- Compliant Duration of test 000 h Concentration % SO ISO 688 Compliant Duration of test 48 h Concentration 0. dm³ Flowing mixed gas corrosion test IEC 60068-60 Number of the test method Duration of test Compliant 3 j 4 Technical Datasheet SNK6040D00 ABB

Vibrations and shocks Sinusoidal vibrations Functional random vibrations Category Class B 3 axes Long life testing at increased random vibrations Category Class B 3 axes Shock Category Class B 3 axes IEC 60068--6 Compliant Frequency range... 00 Hz Number of cycles Acceleration 7 m/s² IEC 6373 Compliant Duration of test 0 mn Frequency range... 0 Hz Acceleration m/s² IEC 6373 Compliant Duration of test h Frequency range... 0 Hz Acceleration,7 m/s² IEC 6373 Compliant Duration of test 30 ms Acceleration G ZK.-D-PE Terminal Block Accessories Compatibility Some accessories may modify the terminal block's rating. See complete information in the accessories catalog page. Description Type Order Code Pack (ing) Weight pieces g ( pce) MG-CPM 3 SNB0470R0 60 0.36 3 4 6 6 7 8 8 End Sections End Stops Test Connectors Test Connectors Test Adapters Test Adapters Shield Connectors Tools Tools MC MC-YL MCPA PROCAP UMH SAT PR3.G PR4 PR PR30 PR3.Z PR0 EK.-D BAZH TC TC-R TP TP4 SHB PS-3 JB- JB-3 JB-4 JB- JB-0 JB-0 SNK40000R0000 SNK40004R0000 SNK4R0000 SNK0060R0000 SNK006R0000 SNK0064R0000 SNA64800R0300 SNA6800R00 SNA68700R00 SNA730R000 SNA74300R700 SNA78R0400 SNK7060R0000 SNK000R0000 SNK0000R0000 SNK000R0000 SNK0003R0000 SNK000R0000 SNK0060R0000 SNK0060R0000 SNK006R0000 SNK030R0000 SNK0303R0000 SNK0304R0000 SNK030R0000 SNK030R0000 SNK030R0000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 30 0.00.00 0.00 0.70 0.0 6.00 78.00.00 700 38.00 78.00 88.00 3.40 4.00.0.0.70.40 4.0 380.00.30.00.70 3.0 7.0 36.00 ABB Technical Datasheet SNK6040D00

Contact us ABB France Electrification Products Division PG Connection 3, rue Jean Perrin F-6687 Chassieu cedex / France Tel. +33 (0)4 7 7 Fax +33 (0)4 7 3 Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 0 ABB All rights reserved SNK6040D00 - PDF