UV16 vandal resistant, wet/damp location emergency lighting

Similar documents
exit signs solid state lighting emergency lighting wayfinding signage ballasts & controls central systems

LED EXIT SIGN WITH REMOTE CApability

A R C H I T E C T U R A L LO W L E V E L F LO O D L I G H T S E R I E S

Luxray LED Series Low-Profile, Slim Look Light Fixture

Project: 1 IP65 Rated fixtures are rated for use outdoors where exposed directly to water from rain or irrigation.

LUMENTON. including poured concrete. Suitable for installation within 4 feet of ground. Product specifications subject to change without notice.

A R C H I T E C T U R A L WA L L L U M I N A I R E S E R I E S

L Listed FEATURES. Series Lamps Wattage # of Lamps ICR= remote fixture 7= 7.2 watts. L Listed. Phantom TM FEATURES

Lumencia. LLMPS SERIES Micro Power Systems. Multi-Unit Residential Lighting. Job Name: Type:

FCW3043 ADA FCW3045 ADA FCW3042 ADA FCW3040 ADA

AFL FLOODLIGHT SERIES

Fixed Head Emergency Lights

PGL350P W PS Wallpack

LED STEP LIGHT LED Forms

20W LED Strip Light for Hazardous Location Lighting - 24" Surface Mount Bar - Class 1 Division 2

4" (10cm) 15H1-250W 18F1/F1E - 62W K 18H1-300W. Standard 120V (leave blank) 2 230V 50Hz 3 277V 60Hz. 14" (36cm)

3900 BOLLARD SERIES.

High-Performance Industrial Emergency LED Lighting LHP & LHPR SERIES

Saturn Cutoff. Order Code: Pole Order Code: Series Height Finish Options. Customer: Date: Project: Qty: Type: SAC Saturn Cutoff SAC

CODE MANDATED INTERIOR EMERGENCY LIGHTING:

16 Watt White LED Strip Light for Hazardous Location Lighting - 24" Surface Mount Bar - C1D2

OUTDOOR TRACK. LABELS Assembled in America

Laredo Decorative Wallpack Family

Weather Protective Devices

Introduction. Porcelain 4KV pulse rated medium/mogul base socket Silicone gasket

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

DELUGE FAMILY. Wet Location Emergency Units RPN CRPN RMN EBN

Laredo - Decorative Wallpack Family

SPECIFICATION SHEET :FH6-DUAL-3000L. Project Type Model # Remarks

UL AND CODE COMPLIANCE

Perimaliter Wallpacks

LITON FLOOD / SPOT O U T D O O R A D J U S T A B L E L I G H T I N G

Emergency Lighting. Not Available in Canada. CE 464 CC 465 CCE 466 CEL 467 CEW 468 CWC 469 CSR 470 RME 471 CIR 472

BAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by:

Low Bay LED Light - 250W Metal Halide Equivalent - 12 LEDs - 40 Watt High Output LEDs

The Noah Emergency Lighting Wet Location Family RMRN PRMRN SWN SLBN

Project: Type: Qty: Height Lamping Finish Voltage Options. Series MTRQ /8" (1252mm) /16" (551mm) Options

Pole Series. Series Reflector Lens Mounting Lamping Finish Voltage. S w S w S w S w

220/230/240V Watt High Pressure Sodium - Hazardous Location Lighting - C1D2 - Pole Mount

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

VINCI-LED Wall/Area/Flood Lighting

36 Watt LED Wall Pack Light 250W Metal Halide Equivalent Watt LEDs - 2' Cord w/ 5-15 Plug

Perimaliter Wallpacks

Code Master Incandescent Factory Sealed Luminaires Explosionproof, Dust-Ignitionproof For use with threaded metal conduit.

DLTC. lighting controls. transfer circuit for use with low-voltage down-lighting. features

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination

1000 Watt Metal Halide Flood Light - 110,000 Lumens - Slipfitter Mount - 120~277 Volts AC

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination

18 Watt LED Fixture for Industrial Lighting - Aluminum Housing 120/277 or 12/24VDC - IP65 Waterproof

31 Watt Low Voltage LED Fixture for Industrial Lighting - Adjustable Trunnion U-Bracket Mount

Industrial & Harsh Environment - Battery Units

S HINE V ENTURE L IGHTING S LED LAMPS. Quality retrofit LED lighting products from a leader in the lighting industry. Full range dimming

Low brightness and uplighting combine to create a pleasing visual environment. Softbay Series

TRAILBLAZER LIGHTING TRAILBLAZER LIGHTING

20W LED Strip Light for Hazardous Location - 24" Surface Mount Bar - Motion, Day/Night Sensor - C1D2

DURAGUARD ELECTRONIC HID LIGHTING


Lighting: Fluorescent Lighting FL Series: Light Duty Nonmetallic Fluorescent Lighting Fixtures, Standard and Emergency Battery Back-Up Zone 2 & 22

Everline LED Fixtures & Retrofit Kits

Specification Sheet: EcoPark LED Parking Garage Fixture. Indoor/Outdoor

Catalog # Project. Comments. Prepared by. 11" [279mm] 8-3/4" [222mm] ESCUTCHEON PLATES. 2-5/8" [67mm] 3/4" [19mm] Dia. Hole. 3" [77mm] 1-1/2" [39mm]

Series Optics Mounting Lamping Finish Voltage. H039T6 1 39wT6 H w. H w. (T6 only available with MA and MS refractors) 12 3 /8" (314mm)

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:


For complete photometric data, refer to the back cover of this brochure.

ENERGY SAVING PRODUCTS LIGHTING

Magnetic Mount 60 Watt Low Profile LED Flood Light - Glare Shield - 10' Cord V AC

Applications. Illustrated Features

Luminaires - LED High Bay

1000W High Intensity LED Crane Light - 110,000 Lumens V AC - Stainless Steel Bracket

HAZARDOUS LOCATION CLASSIFIED AREAS LW1 AND LW2 SERIES DOWN OR UP OPTICS

ROOF. design: Laura Andreini

LEDWP LED Wall Pack Light - 400W Metal Halide Equivalent - 12 LEDs - 10ft Cord High Output

Height Finish Pole Options. Mounting Lamping Finish Voltage. Metal Halide. Single. H w H070 70w H w H w 15 1 /4" (387mm) 15 3 /4"

PRIMUS I PRIMUS II. Primus - Downlight. Primus - Wall Wash SPEC SPEC. Trim Options

7 Watt Compact Aluminum LED Fixture for Hazardous Area Location Lighting - No Mounting Bracket

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

Hubbell Lighting Expressline Family 2009

Induction Compact Fluorescent HID LPQ. Canopy Luminaire

Quick Facts LED RECESSED LUMINAIRES

9 4 L I N E R E C E S S E D S T E P & A I S L E L I G H T I N G


Applications. Standard Materials

P hoenix Products introduced loading dock lighting to the


Exit and Emergency Lighting Products PRODUCT CATALOG

Industrial luminaires

18 Watt LED Industrial Light Fixture - Day/Night Sensor - Aluminum V AC - IP65 Waterproof

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens

HALO H1499T. 4" RECESSED DOWNLIGHTING Incandescent

Industrial luminaires

LAD8 8 LED Architectural Downlight

Taxonomies, Classifications, and Categories LED FLOODLIGHTS, WALLPACKS, BOLLARDS & LANDSCAPE LIGHTING

The Induction Cobrahead Series can be used in a variety of roadway lighting applications. All of the

NRM2-511 / NRM2-512 / NRM2-518

LightWave Lighting Technology

COMPLETE OFFERING - 2 nd EDITION

LCD6 6 LED Commercial Downlight

LCD8 8 LED Commercial Downlight

Transcription:

UV16 vandal resistant, wet/damp location emergency lighting 120/277 VAC, 60 Hz dual voltage input Maintenance-free, sealed lead calcium battery Molded from high-impact polycarbonate Simplified installation with snap-together backplate/housing Illumination is supplied with two high-performance, 5.5 watt, 6 VDC, fully adjustable MR16 halogen lamps UL 924 listed UL Damp Location listed, UL Wet Location listing optional NFPA 101, NEC, BOCA, OSHA and IBC illumination standards Meets ADA specifications for wall mounted lighting fixtures Input power requirements 120 VAC: 0.05 A, 0.30 A with heater option 277 VAC: 0.02 A, 0.13 A with heater option Damp Location: 50 F (10 C) to 104 F (40 C) Wet Location: 41 F (5 C) to 104 F (40 C) Wet Location with Heater: -4 F (-20 C) to 104 F (40 C) Electronics - three years full; Battery - one year full, four years pro-rata 7.66 (19.46 cm) 3.72 (9.45 cm) 8.67 (22.02 cm) UV16 L SERIES UV16 = Unison Vandal L = Lead Calcium Series, 11 Watt BATTERY HOUSING COLOR LOCATION LISTING W = White B = Black Blank = Damp Location WL = Wet Location HR = Wet Location w/ Battery Heater T15TPTOOL = Tamperproof Tool 27

Exterior AC/Emergency Fixtures decorative emergency lighting units 120/277 VAC, 60 Hz dual voltage input 4 or 6 volt operation Maintenance-free, sealed nickel cadmium battery Low temperature ballast available on select models Constructed of impact-resistant polycarbonate Illumination is accomplished with compact fluorescent lamps in AC operation and wedge base incandescent lamps in emergency operation NFPA 70 and NFPA 101, NEC, BOCA, OSHA and IBC illumination standards Input power requirements at 120 VAC C30SEM: 0.15 A, 17 watts; C300EM: 0.15 A, 17 watts C300WEM: 0.15 A, 17 watts C1200EM: 0.30 A, 34 watts 20 F (-7 C) to 95 F (35 C) Electronics - three years full; Battery - five years full, five years pro-rata C30S 8.8 (22.4 cm) 2.5 (6.4 cm) SERIES 1 LENS TYPE HOUSING C30SEM C300EM C300WEM C1200EM C = Clear Prism O = Opal White WH = White BR = Bronze (see color chart) Note: If product will be controlled by either lighting contactor, photocell or time clock, please consult factory to ensure compatibility. Housing Color Availability SERIES BLACK WHITE BRONZE C30SEM C300EM C300WEM C1200EM 1.8 (4.6 cm) 4.3 (10.9 cm) 10.1 (25.7 cm) 9.8 (24.9 cm) 2.4 (6.1 cm) 4.8 (12.2 cm) 0.8 (2.0 cm) 3.4 (8.6 cm) 6.3 5.8 (16.0 cm) (14.7 cm) 3.0 (7.6 cm) C300 4.8 (12.2 cm) OPTIONS 5.9 (15.0 cm) 5.6 (14.2 cm) TP = Tamperproof (requires T15TPTOOL) Z = Cold Weather Ballast (AC only) Conduit Connections 2 CT = Top Conduit Connection CB = Bottom Conduit Connection CR = Right Conduit Connection CL = Left Conduit Connection Note: 1) Matching non-emergency fixtures are available. Consult factory. 2) Not required for C30S - five knockouts already provided. C300 and C300W suit able for 1 /2" or 3 /4" conduit. Specify conduit location relative to front view of luminaire. 2.1 3.1 (5.3 cm) 8.7 (22.1 cm) (7.1 cm) 1.0 (2.5 cm) C300W 1.1 (2.8 cm) C1200 11.1 (28.2 cm) 3.1 (7.1 cm) 8.8 (22.4 cm) 10.3 (26.2 cm) 9.1 (23.1 cm) 12.0 (30.5 cm) 12.0 (30.5 cm) 5.8 (14.7 cm) 3.1 6.1 (15.5 cm) 12.0 (30.5 cm) 4.6 (11.7 cm) 28

Outdoor Remote Lamp Heads MR16 and lamp assemblies Die Cast Aluminum MR16 Remote Lamp Head (LEF) 12 volt, 20, 35 or 50 watt MR16 lamps available Constructed of durable die cast aluminum Available in black or bronze Single or double mounting plates available LEF SERIES NUMBER OF HEADS TYPE OF MOUNTING PLATE COLOR MR16 LAMP TYPE LEF = Decorative Outdoor Remote Head 1 = Single Remote Head 2 = Double Remote Head 7.8 (19.81 cm) R = 4 Round Mounting Plate S = Single Gang Rectangular Mounting Plate 20WF = 12 Volt, 20 Watt Wide Flood 40 35FL = 12 Volt, 35 Watt Flood 25 35WF = 12 Volt, 35 Watt Wide Flood 40 50FL = 12 Volt, 50 Watt Flood 25 50WF = 12 Volt, 50 Watt Wide Flood 40 6.5 (16.51 cm) ORBBK = Outdoor 4 Round Surface Mount Junction Box, Black ORBBZ = Outdoor 4 Round Surface Mount Junction Box, Bronze OSBBK = Outdoor Single Gang, Surface/Recessed 2 3 /4 x 4 1 /2 Junction Box, Black OSBBZ = Outdoor Single Gang, Surface/Recessed 2 3 /4 x 4 1 /2 Junction Box, Bronze 4.1 (10.41 cm) 1.6 (4.06 cm) (7.11 cm) 4.5 (11.43 cm) 2.1 (5.33 cm) Die Cast Aluminum MR16 Recessed Lamp Head (LRE) 12 volt, 20, 35 or 50 watt MR16 lamps available (order as a separate item) Constructed of durable die cast aluminum Available in black or bronze Masonry, concrete or deck mounting only 5.38 (13.67 cm) 1.63 (4.14 cm) 4.69 (11.9 cm) HOW TO ORDER LREBK = Outdoor Remote Head Recessed, Black LREBZ = Outdoor Remote Head Recessed, Bronze 2.0 (5.08 cm) 29 HOW TO ORDER 12MR20WFL = 12 Volt, 20 Watt, 40 Beam Spread 12MR35FL = 12 Volt, 35 Watt, 25 Beam Spread 12MR35WFL = 12 Volt, 35 Watt, 40 Beam Spread 12MR50FL = 12 Volt, 50 Watt, 25 Beam Spread 12MR50WFL = 12 Volt, 50 Watt, 40 Beam Spread 1.8 (4.57 cm) Glass Cover

NightWatch LED Bollard outdoor general/emergency LED lighting Premium die cast aluminum light engine, fiberglass-reinforced polymer bollard, stainless steel exposed hardware Standard powder coat finishes include black, bronze and white, with custom finishes also available Energy-efficient, long-lasting, high-intensity, white LEDs offer even illumination Each light engine utilizes three high-performance, white LEDs and can be applied from one to all four sides of the bollard The bollard can be readily affixed by an anchor base, lag bolts or direct burial The NightWatch Power System provides normal and emergency power support, sold separately (see page 72) ETL listed to UL 1598 and 1838 standards Input power requirements: 10 watts per LED light engine Standard: -31 F (-35 C) to 104 F (40 C) Electronics - three years full 36.187 (91.91 cm) 5.0 (12.7 cm) Poured Concrete Footer, By Others NW SERIES BOLLARD FINISH BASE TYPE # LUMINAIRES & ORIENTATION LUMINAIRE FINISH INPUT VOLTAGE NW = NightWatch Bollard Series XX = Custom A = Anchor Base D = Direct Burial L = Lag Bolt NWPS1 = NightWatch Low Voltage Power System for Normal and Emergency Power Support (compatible with 12 VAC/VDC models only) 190 = (1) @ 90 Degrees 290 = (2) @ 90 Degrees 390 = (3) @ 90 Degrees 490 = (4) @ 90 Degrees 2180 = (2) @ 180 Degrees WH = White XX = Custom 1 = 12 VAC/VDC 2 = 120 VAC 30

Eclipse outdoor forward throw cutoff luminaire with integral remote emergency lamp 120/208/240/277 VAC, 60 Hz, multi-tap input wiring AC only or emergency operation Constructed of premium die-cast aluminum with a powder coat finish Stainless-steel torx head T25 tamperproof hardware included Easy installation with pre-mountable wall box with integral splice chamber, built-in bubble level and a polarized low-voltage emergency power connector supplied with a 10 foot interconnect Illumination is accomplished with one 100 watt, high-pressure sodium lamp or one 100 watt, metal halide lamp combined with a polished specular aluminum reflector with type 4 distribution Normally on illumination may be switched or photocell controlled Emergency illumination is accomplished with a 35 watt, instant strike Xenarc lamp powered from a remote emergency battery unit Emergency units require a remote 12 VDC power source such as LightGuard's LPM50LWDLTD (indoor/outdoor recessed ceiling mount) or V1250SCTD (indoor surface mount), sold separately Wet Location listed ETL listed to UL 924 and 1598 standards, CSA C22.2 No 141-02 and CSA C22.2 No 250.0-04 standards NFPA 101, NEC, BOCA, OSHA and IBC illumination standards 120/208/240/277 VAC, 60 Hz, multi-tap input wiring, 130 watts power consumption Wet Location: -40 F (-40 C) to 104 F (40 C) Five years (excludes lamps) 17.0 (43.2 cm) 9.25 (23.5 cm) 7.25 (18.4 cm) FTCL SERIES AC LAMP TYPE EMERGENCY FUNCTION 1 HOUSING COLOR FTCL = Forward Throw Cutoff Luminaire 1H = 100 Watt, High-Pressure Sodium Lamp 1M = 100 Watt, Metal Halide Lamp Blank = AC Only Fixture, No Emergency Lamp EM = 35 Watt, Instant Strike Xenarc Lamp BZ Note: 1) Requires a remote emergency power source of 12 VDC and at least 35 watts and TD to cover re-strike period. Xenarc is a registered trademark of Osram Sylvania 31