VADA - V75-S PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

Similar documents
VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

OWNER`S MANUAL SMH RANGE HORIZONTAL MULTISTAGE CENTRIFUGAL PUMPS SMH35 SMH45 SMH55 SMH75 SMH90

DRENOX SUBMERSIBLE SUMP PUMPS FOR DRAINING CLEAR WATER. Usage limitations

OWNER S MANUAL SINGLE STAGE STAINLESS STEEL CENTRIFUGAL PUMPS SSS SERIES. Installation / Operation / Troubleshooting SSS702 SSS2102 SSS2103 SSS3703

Installation and Operating Instructions for Davey HM Series Pressure Systems with Pressure Switch

OPERATION & MAINTENANCE INSTRUCTIONS

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105

OWNER S MANUAL. Horizontal Multistage Centrifugal Pumps. SMH Range

OPERATION & MAINTENANCE INSTRUCTIONS

StormPro BA Series Sump Pump

FOR NEW ZEALAND. T-604 WASTE DISPOSER B. HYDRAULIC CHARACTERISTICS &TECHNICAL SPECIFICATIONS. DECLARATION OF COMPLIANCE

Matala. VersiFlow Series. Instruction and Maintenance Manual

VERSION 2017 V.1.0

ESE Series Cast Iron Sewage Pumps

FARMMASTER. JJ & OJ Series

SUBMERSIBLE DIRTY WATER PUMP

Owner s Manual Drill and Light Weight Portable Utility Pumps

StormPro BCV400 Sewage Ejector Pump

OWNERS MANUAL ECODIVER

Submersible Pump Instructions. Safety Instructions

OWNER S MANUAL VF150 SUBMERSIBLE PUMP. An earth leakage or residual current protection device must be fitted to all installations.

Centrifugal Pumps (Part Nos. PS2SS PS73SS) PS2SS

1/2 HP SUMP PUMP OWNER'S MANUAL

OWNER`S MANUAL. 112/252, 14, 18 SERIES HI-FLO CENTRIFUGAL PUMPS High flow water transfer. Suitable for tank filling & irrigation.

SUBMERSIBLE WATER PUMPS

Installation and Operating Instructions. WHISPER Series, TYPHOON C & T-Series Swimming Pool Pumps

GeyserMax-Flow Series

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

Installation and Operating Instructions

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

COLLECTION STATIONS AND WASTE WATER LIFTING DESIGN SPECIFICATIONS

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

TPAK Series COOLANT PUMP

Installation and Operating Instructions for

INSTALLATION MANUAL. Installation Details Warranty Wolfen 122 Wall Bubbler Wolfen 90 Wall Bubbler Wolfen Hob Bubbler

Installation and Operating Instructions for Davey HP, HS & HM Pressure Systems with Presscontrol

SUBMERSIBLE WATER PUMP

77014 / Automatic Users Manual. Carefully read this entire Instruction Manual before using this product

Owners Manual: - Pumps

Sump Pump. Installation and Operating Instructions

SUBMERSIBLE WATER PUMP

ROCA KHROMA TOILET SUITE

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

INSTALLATION MANUAL. Installation Details Warranty Wolfen Hand Held Trigger Spray Assembly With Stop Tap

SUBMERSIBLE PUMPS HSE RANGE OPERATING & MAINTENANCE INSTRUCTIONS GC0514

ELECTRIC LIFTING HOIST

OMEGA UNDER COUNTER MECHANICAL BTW 4S CONCEALED CISTERN

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual WALRUS PUMP CO., LTD. ISO 9001 Certified NSF/ANSI 372

SUBMERSIBLE WATER PUMP

HIDEAWAY PLUS IN-WALL CISTERN (BACK TO WALL PAN)

INSTALLATION MANUAL Wolfen Cleaners Sink With Grate. Installation Details Warranty

INSTALLATION MANUAL. Installation Details Warranty Wolfen Folding Shower Seat 600mm Wolfen Folding Shower Seat 960mm

HALLMARK INDUSTRIES INC

Installation & Operating Manual

OWNER S MANUAL. Jet Assisted Pumps Series

Installation, Maintenance and Operation manual 4 Submersible sand fighter pump. Type: SSFP - Series

SUBMERSIBLE PUMP HSE RANGE

TPHK Series Immersible Pump

8000 / 10,000 / 12,000

SUBMERSIBLE WATER PUMP OPERATING & MAINTENANCE INSTRUCTIONS. Model Nos. CSE400A. Part No iss 2

ROCA THE GAP BACK TO WALL TOILET SUITE

SUBMERSIBLE PUMP HSE RANGE

Operating Instructions

SELF PRIMING CHEMICAL SERVICE PUMPS

Submersible Pump BIA-B10A BIA-B15A BIA-B25A BIA-B40A BIA-B42A BIA-B15VA BIA-B25VA BIA-B40VA BIA-B75A BIA-B75VA BIA-B75KA BIA-B120G

MP V 8A Electronic Smart Charger. Instruction and Information Manual

Installation & Operating Manual

ROCA DUO PLUS OVAL INSET BATH

ALAPE METAPHOR UNDERCOUNTER BASIN

1600 PSI ELECTRIC PRESSURE WASHER

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

MECHANICAL UNDER COUNTER 150 CONCEALED CISTERN (BTW)

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230

Installation and Operating Instructions for Davey HS20-65Y2 Multistage Pump

DOMINIQUE MKII wall hung vanity 900mm. Wall Hung Vanity 900mm (Left Hand Bowl) Cabinet Only - Front View Cabint Only - Side View

INSTALLATION MANUAL. Installation Details Warranty Wolfen Foot Operated Pedal Valve Wolfen Foot Operated Kit with Outlet

WATERPRESS BOOSTER SETS WITH 24L HORIZONTAL EXPANSION TANK. Design features

Domestic Water Supply Pressure Pumps

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

ROUND REMOTE BUTTONS AND PLATE (IN-WALL)

garden PUMP kit 1 Depth A & B must be less than 9m Max Depth C must be less than 9m Max GardenPump Inst 6/11/07 12:52 Page 1

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

INSTALLATION MANUAL. Installation Details Warranty Wolfen Pre Rinse Sink Mixer Wolfen Compact Pre Rinse Sink Mixer

MIZU QUICK CHANGE DUAL FILTER SYSTEM

GARDEN HOSE UTILITY PUMP

IT GB F D E NL SF P S RUS CZ SI SK HR SCG

DOMINIQUE MKII SEMI RECESSED vanity

ELECTRIC FOLDING BIKE OWNERS MANUAL. e-power 36v. Go City-Lite

SUPER PUMP OUT SYSTEM

Bianco RainsaverMK6 uses WaterMarked components and incorporates a dual check valve for back flow prevention for the mains water.

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

POND PUMP Model Nos:SPP3 & SPP6 0200

OWNER S MANUAL. Dominator Submersible Pump. For the Installation, Operation and Service of

June14. Type

AXA Cento semi wall basins with shelves

MINIPOND 700/900 Mk2 THE POND MASTERS GUIDE TO. Blagdon - The Pond Masters The name you can rely on

SS/SSH Submersible Pump. Owner s Manual

PRESSURE BOOSTER 150

SUNC3000 / Item #40885

Transcription:

PRODUCT OVERVIEW The VADA V75-S submersible pumps are suitable for installation in traditional wells, water deposits, collection tanks, clear watercourses, lakes etc. The V75-S provides a hydraulic system resistant to sand corrosive action. CONSTRUCTION Pump Body Suction Grid Base Impeller Diffuser Diffuser cap X5 CrNi 1810 (AISI 304) stainless steel X16 CrNi 16 (AISI 431) stainless steel Noryl Acetal resin Polycarbonate with ceramic insert in the point of wear Polycarbonate with stainless steel inserts in the point of wear Motor Shaft Hexagonal, in X10 CrNiS 1809 (AISI 303) stainless steel with ceramic insert at the point of wear. AISI 416 for the out of water parts. Mechanical Seal Counterface Power Cable Non-Return Valve Discharge Head Graphite Aluminium oxide 20m H07 RN-F Integrated - Plastic Noryl with 1 1/4 threaded insert Note - Thrust bearing ring inserted in every stage USAGE LIMITATIONS Type of liquid: clean water with no suspended solids or abrasive material Maximum liquid temperature: 40 O C Maximum submersion depth: 20m Minimum diameter of tank/well: 100mm (without float) MOTOR Dry motor with stainless steel casing cooled by pumped liquid Level of protection IP 68 Class F insulation Single phase power supply with capacitor permanently activated Thermal protection built into the motor winding Completely insulated cable connection chamber Self-lubricating ball bearings Speed of rotation 2850 rpm Suitable for continuous use WARRANTY You have purchased a quality product from Reece Australia. This product is covered by a 24 month warranty. This warranty covers faults in the product construction, material and assembly. Faulty products will be repaired or exchanged free of charge. Faulty items become our property. This warranty does not include faults caused by Unsuitable or improper use Incorrect installation Normal wear and tear Inadequate or complete lack of maintenance Chemical, electrochemical or electrical influences To the maximum extent permitted by law, Reece excludes all warranties other than those set out above. In the event of a warranty claim, we will replace or repair defective products, or pay for the cost of having defective products repaired or replaced, but will not be liable for any injury to any person, damage to any property, any indirect or consequential loss, or in any other respect.

TABLE OF HYDRAULIC PERFORMANCE 60 50 40 V75-S 30 20 10 Hm L / 1' Q m 3 / h 10 20 30 40 50 60 70 80 90 100 0,6 1,2 1,8 2,4 3,0 3,6 4,2 4,8 5,4 6,0 PUMP PERFORMANCE Model Absorbed Nominal power L/1 0 20 40 60 80 power No. Voltage Amp µf Stages Q HP kw HP kw m3/h 1.2 2.4 3.6 4.8 V75-S 0.8 0.6 1 0.75 1~220/240V 3.3 16 8 Discharge head in meters 56 49.8 38.1 19 OUTLET PORT A ØC PUMP DIMENSIONS Model Dimensions (mm) A Ø C Free Bore Outlet Port kg Weight V75-S 643 98 2mm 1 1/4 F 9.6

INSTALLATION Please pay careful attention to the following warnings signs and indications. Only qualified, licensed personnel should install pump. The electrical installation shall be in accordance with the national wiring rules (AS/NZS 3000) for class 1, IP44 rated products. These instructions are a guide only. Users not familiar with pumping equipment should seek advice from people experienced in pump equipment and installation. The pump is designed to be used with clean water in a residential application. Do not use it with alternative fluids, specifically abrasive, corrosive or explosive fluids. Do not install or operate your pump in an explosive enviroment or near combustible matter. Incorrectly installed or tested equipment may fail, causing severe injury or property damage. Freezing conditions will damage the unit, because when water freezes it expands. Ensure that the pump is located so that it is not prone to freezing, or ensure that the product is disconnected and dried of water during cold conditions. The pump is electrically connected. Ensure that it is isolated from electrical supply during installation and any subsequent service work. Fire and burn hazard. Modern motors run at high temperatures. To reduce risk of fire, do not allow leaves, debris, or foreign matter to collect around the pump motor. To avoid burns when handling the motor, let it cool for at least 20 minutes before trying to work on it. A thermal overload switch protects the motor for heat damage during operation. PREPARING FOR INSTALLATION Inspect your pump, ensuring that it is well packaged and has not been damaged in transport. If the pump is damaged, report it to the Reece branch where the pump was purchased. Warranty of these pumps is void unless they are operated in accordance with these instructions. PUMP PROTECTION Avoid using the electrical cable to lift or transport the pump.

GENERAL INSTALLATION 1. Fitting and Auto Pressure Control or Mains Water Switch Over Device If you are using a Vada Auto Pressure Control or Mains Water Switch Over Device with your pump, it needs to be mounted externally to the tank in a suitable position in line with the delivery piping. This can be achieved using a mounting bracket. The unit should be mounted vertically in a position which is out of the weather. Depending on the type of plumbing fitting used to connect to the inlet (underside) of the Auto Pressure Control or Mains Water Switch Over Device, the unit may not be clamped firmly to the bracket. We recommend a spacer is fitted where necessary. For further instructions on connecting these devices, please refer to the manual for your unit. Ensure that the power lead remains disconnected until you have completed the installation process. 2. Locating the Pump Using the anchor point at the top of the pump, connect a nylon rope (provided) or a stainless steel cable suitable to sustain it s weight. Anchor the other end of the rope or cable so that it balances the weight of the pump as it rests upright at the base of the tank/well. 3. Power Source Arrange for an electrician to install a 10A weatherproof outdoor power point near the pump if there is not one there already. 4. Suction It is advisable to fit an automatic level control/float switch to prevent the pump from running without fluids. The V75-S inlet is intentionally raised from the base to prevent the pumping of sediment. To raise this height further, use a length of 3 PVC pipe and insert it into the specially designed base of the pump. 5. Discharge It is advisable to fit a check valve on the discharge piping to prevent fluid from re-circulating when the pump has stopped. The length and diameter of the discharge hoses/pipes will affect the pressure and flow rate at which your pump operates. Pressure ratings of all components must exceed the maximum pressure of the pump by an appropriate safety factor. All pipe work should be supported independently of the pump. ELECTRICAL INSTALLATION In accordance with AS 3350.2.41 we are obliged to inform you that this pump is not to be used by children or infirm persons and must not be used as a toy by children The pump must be supplied by an outlet protected by a residual current device or earth leakage circuit breaker with a maximum rated residual current of 30mA The pump is supplied with: A fixed cable featuring a weatherproof IEC socket A separate power cable which features a weatherproof IEC plug and a standard Australian 10 amp plug. If connecting directly to a power outlet, simply connect the two supplied cords using the IEC socket and plug. If you are installing a Vada Auto Pressure Control or a Mains Water Switch Over Device, connect the IEC socket from the pump to the IEC plug cord on the device. Before plugging the power supply cord into the socket outlet, ensure that the socket outlet is supported by the delivery pipes at 3 meter intervals. Ensuring there are no water traces on the connectors push them firmly into each other to ensure intended splash (water) proof protection. This connection shall be separated again only for service purpose and only after the power supply is removed by unplugging the cord form the socket outlet. The socket outlet shall be in dry and flood free location; preferably do not use extension cords for this very reason and because they can cause voltage drop. Supply voltage outside limits specified in Model Data can cause motor overheat leading to overload tripping, reduced component life or seriously damage pump and voids warranty. For additional protection, the pump must be supplied from an outlet protected by a residual current device RCD (also known as an Electrical Leakage Circuit breaker ELCB) with a maximum rated residual current of 30mA.

OPERATION The pump operator or owner must be provided with this owner s manual. This must be read before operation, and followed during operation. DO NOT RUN PUMP DRY Ensure that your pump is submerged in water before operating. The pump is designed to be used with clean water in a residential application. Do not use it with alternative fluids, specifically abrasive, corrosive or explosive fluids. Do not install or operate your pump in an explosive enviroment or near combustible matter. START-UP/OPERATION Open all valves in the suction and discharge lines. When the power is turned on, the pump will start to pump water. Without an Auto Pressure Control or Mains Water Switch-Over Device, the pump will continue to operate until the power is switched off. Most applications will incorporate an Auto Pressure Control or Mains Water Switch-Over Device which will stop the pump as soon as it has pressurised the system it is connected to. For instructions on operating your pump with one of these devices, please refer to the manual that came with your unit. The system is now ready for use. If no water is delivered, check the troubleshooting section. SERVICE AND MAINTENANCE Pump should only be serviced by qualified personel. For best results, use only genuine service parts. Be sure to prime pump before starting. Liquid may be HOT, release pressure with care before servicing. To avoid dangerous or fatal electrical shock hazard, turn OFF power to motor and remove plug from power outlet before working on pump or motor. GENERAL CARE AND MAINTENANCE Under normal conditions V75-S pumps do not need any type of maintenance. In order to avoid possible failures, it is advisable to periodically check the pressure supplied and current absorption. A decrease in pressure is a symptom of wear. An increase in current absorption is a sign of abnormal mechanical friction in the pump and/or motor. If the pump is not going to be used for long periods of time it should be emptied completely, rinsed with clean water and put in a dry place. Cleaning the filter If the sucked water is not perfectly clean, it may be necessary to clean the filter with a steel brush to scrape the dirt accumulated on the external surface. It is also possible to clean the internal section of the filter. Loosen the screw that fixes the filter to the body of the electropump and remove it. Scrape the dirt with a steel brush and rinse it with clean water. If this is not sufficient, have the hydraulic parts cleaned by an authorised centre.

TROUBLE SHOOTING GUIDE Symptom Cause Remedy The motor will not start, no water is pumped No electricity Ensure that the pump is connected to a live outlet Motor protection tripped Defective condenser Verify the cause and reset the switch. If the thermal circuit breaker has tripped wait for the system to cool down Replace the condenser Shaft blocked Verify the cause and unblock the pump The motor runs but no water is pumped The pump is sucking air Makes sure that the joints are airtight Check that the level of liquid has not dropped below the minimum priming level. The pump rotates in the wrong direction Reset the direction of rotation Suction grid blocked Clean the suction grid Check valve blocked Clean or replace valve The pump stops after running for a short period of time because the thermal motor circuit breaker trips The power supply does not conform with the data on the nameplate A solid object is blocking the impellers The liquid is too thick Check the voltage on the power supply cable leads Call 1800 032 566 for your nearest Reece branch See your local Reece branch for an alternative pump