Project Number Date 17.01926 7/17/2017 Test Sample Description Catalog Number: Description: P90310927K9 Med Flex Head, Single Arm Gimbal Design Track Lighting Lab 1 Sphere Photometry Test Method: Preburn Time: Time To Stabilize: Total Operating Time: Input Voltage (Volts) : Input Current (Amps) : Input Wattage (Watts) : Ambient Temp ( C) : Sphere IES LM-79-08 10 Test Method: IES LM-79-08 9.1 & 12.1 00:05 Preburn Time: 1:00 0:75 Time To Stabilize: 0:48 2:04 Total Operating Time: 1:48 120.1 Input Voltage (Volts) : 120.0 0.057 Input Current (Amps) : 0.057 6.6 Input Wattage (Watts) : 6.6 24.4 Ambient Temp ( C) : 24.8 Hubbell Lighting, Inc. 701 Millennium Boulevard Checked (sphere) : Checked (photometry) : Approved: B. LEE D. ROBBINS D. BLACK TESTING NVLAP LAB CODE: 201003-0 This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. Page 1 of 8
Test #: 17.01926 Date: 7/17/2017 Lamp Cat#: Lamp Desc: Driver Desc: BXRE-27G0800-B 1 - Bridgelux 2700K LEDs N/A Efficacy: 66.8 LPW S/P Ratio: 1.3 LM'/LM Spectral Results Name Value Unit Φ 1.53 watts Φ(v) 441 lumens Φ(v') 588 lm' Chrom x 0.4536 Chrom y 0.4075 Chrom u 0.2599 Chrom v 0.3501 Duv 0.0008 Chrom u' 0.2599 Chrom v' 0.5252 CCT 2763 K Purity 58.5 % λ (dom) 584.1 nm FWHM 141 nm λ (peak) 620 nm λ (center) 608.0 nm λ (centroid) 596.7 nm SDCM Cool White RA 91 Corr. Coef. 0.000644301 Correlation 0.0054 R1 90.8 R2 97.6 R3 96.0 R4 88.5 R5 91.0 R6 96.8 R7 87.9 R8 75.8 R9 50.2 R10 93.8 R11 88.8 R12 83.8 R13 92.7 R14 98.7 Spectral Radiant Flux (W) Spectral Distribution of Radiant Flux 1.00E-02 9.00E-03 8.00E-03 7.00E-03 6.00E-03 5.00E-03 4.00E-03 3.00E-03 2.00E-03 1.00E-03 0.00E+00 350 450 550 650 750 850 Wavelength (nm) This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. Page 2 of 8
REPORT NUMBER: 17.01926 PAGE: 3 OF 8 LUMINAIRE: Med Flex Head, Single Arm Gimbal Design Track Lighting LAMP CAT. NO.: BXRE-27G0800-B LAMP: 1 - Bridgelux 2700K LED MOUNTING: Ceiling / Track NOTE: DATA SHOWN IS ABSOLUTE FOR THE SAMPLE PROVIDED.
REPORT NUMBER: 17.01926 PAGE: 4 OF 8 DEG CANDELA LUMENS 0 1233 5 1128 95 15 403 118 25 182 86 35 147 84 45 13 19 55 3 3 65 0 0 75 0 0 85 0 0 90 0 ZONAL LUMEN SUMMARY ZONE LUMENS %FIXT 0-30 299 73.8 0-40 382 94.6 0-60 404 99.9 0-90 404 100.0 90-180 0 0.0 0-180 404 100.0 EFFICACY = 59.0 lm/w CIE TYPE - DIRECT LUMINAIRE SPACING CRITERION = 0.40 PLANE : 0-DEG 90-DEG SHIELDING ANGLES : 90 90 LUMINOUS DIAMETER: 2.250 LUMINANCE DATA IN CANDELA/SQ M ANGLE AVERAGE IN DEG 45 7167. 55 2039. 65 0. 75 0. 85 0. 450 900 1350 90 75 60 45 0 15 30
REPORT NUMBER: 17.01926 PAGE: 5 OF 8 CANDELA DISTRIBUTION 0.0 1233 2.5 1208 5.0 1128 7.5 961 10.0 768 12.5 570 15.0 403 17.5 295 20.0 233 22.5 200 25.0 182 27.5 169 30.0 161 32.5 154 35.0 147 37.5 119 40.0 78 42.5 37 45.0 13 47.5 9 50.0 6 52.5 4 55.0 3 57.5 2 60.0 1 62.5 0 65.0 0 67.5 0 70.0 0 72.5 0 75.0 0 77.5 0 80.0 0 82.5 1 85.0 0 87.5 0 90.0 0
REPORT NUMBER: 17.01926 PAGE: 6 OF 8 5-DEGREE ZONAL LUMEN SUMMARY 0-5 28 5-10 67 10-15 67 15-20 50 20-25 43 25-30 43 30-35 45 35-40 38 40-45 15 45-50 4 50-55 2 55-60 1 60-65 0 65-70 0 70-75 0 75-80 0 80-85 0 85-90 0 10-DEGREE ZONAL LUMEN SUMMARY 0-10 95 10-20 118 20-30 86 30-40 84 40-50 19 50-60 3 60-70 0 70-80 0 80-90 0
REPORT NUMBER: 17.01926 PAGE: 7 OF 8 COEFFICIENTS OF UTILIZATION - ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0.20 RC 80 70 50 30 10 0 RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 0 119119119119 116116116116 111111111 106106106 102102102 100 1 114112109107 112109107106 105104102 102100 99 98 97 96 95 2 109105101 98 107103100 97 100 97 95 97 95 93 94 92 91 89 3 104 99 94 91 102 97 93 90 95 91 88 92 89 87 90 88 86 84 4 100 93 88 84 98 92 87 84 90 86 83 88 85 82 86 83 81 80 5 96 88 83 79 94 87 82 79 85 81 78 84 80 77 82 79 77 75 6 92 84 78 74 90 83 78 74 81 77 74 80 76 73 79 75 73 71 7 88 80 74 70 87 79 74 70 78 73 70 77 73 70 75 72 69 68 8 84 76 70 67 83 75 70 67 74 70 66 73 69 66 72 69 66 65 9 81 72 67 64 80 72 67 64 71 67 63 70 66 63 69 66 63 62 10 78 69 64 61 77 69 64 61 68 64 61 67 63 60 67 63 60 59 ALL CANDELA, LUMENS, LUMINANCE, AND VCP VALUES IN THIS REPORT ARE BASED ON ABSOLUTE PHOTOMETRY. THE COEFFICIENT OF UTILIZATION VALUES ARE BASED ON THE TOTAL ABSOLUTE LUMEN OUTPUT OF THIS TEST SAMPLE.
Project Number Date 17.01926 7/17/2017 Goniophotometer Calibration Calibration Lamp : GE 1000W, 120V, T6, CL (FEL) Lamp Number: ITL78966-1000-38 Calibration Current: 8.300 Amps DC Total Luminous Flux: 25889.0 Lumens Calibration Date: 07/10/2017 Test Equipment Used Instrument Manufacturer / Model S/N Calibration Due: Goniophotometer ITL/HLI LAB 1 - Test Distance: 31.74' N/A N/A Power Analyzer Yokogawa / WT 332 C2QA27071V 11/2/2017 Power Source Voltage-Regulated House Power N/A N/A Thermometer National Instruments / USB-TC01 176F4EB 11/7/2017 Sphere Calibration Calibration Lamp: EIKO 28V75W/E10 Lamp Number: SCL-1400-J136 Calibration Current: 2.679 Amps Total Luminous Flux: 1427 Lumens Test Equipment Used - Color & SPD; THD & Power Factor Instrument Manufacturer / Model S/N Calibration Due: 3-Meter Sphere Labsphere / LMS-3M N/A Calibrated Weekly Thermometer National Instruments / USB TC01 1912751 11/2/2017 LAMP Power Meter Yokogawa / WT332 C2QA27075V 11/1/2017 Power Supply Chroma / 61602 616020002113 N/A Aux Lamp Supply Labsphere / LPS-100-0833 031159372 10/31/2017 Cal Lamp Supply Labsphere / LPS-150-0268 1218148505 12/1/2017 Spectrometer Labsphere / CDS 1100 0624117792 N/A Hubbell Lighting, Inc. 701 Millennium Boulevard This report shall not be used to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. Page 8 of 8