MIRRORLITE RECESSED EMERGENCY LIGHTING

Similar documents
IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Installation Instructions Central Battery Units

Concealite Life Safety Products Model: R4000 Series (120/277 VAC Powered R4000 Remote Fixtures) Save These Instructions

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

DeSoto NEMA 4X EMERGENCY LIGHTING UNIT. U.S. Versions: 6V- DM90X618 / DM90X654 12V- DM90X1254 / DM90X12100 INSTALLATION INSTRUCTIONS

DeSoto EMERGENCY LIGHTING UNIT. U.S. Versions: 12V- DM (P2 & P3) / DM / DM INSTALLATION INSTRUCTIONS

Self-Testing Industrial Series

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

Spectron Industrial Series

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

Installation Instructions & Users Manual IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

IMPORTANT SAFEGUARDS

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

SURE-LITES FBP140XLP Instruction Manual

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

Prestige Series Edge-Lit LED Sign IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

GUARD-LITE SERIES EMERGENCY UNIT EQUIPMENT

Concealite Life Safety Products Model: F5000 Series. Save These Instructions. Read and Follow All Safety Instructions

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS!

Installation Instruction

UFO-RP3 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING:

UFO-RP2 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

Installation and Operation Instructions 10/04/13

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination

MAINTAINED LED DOUBLE SIDED SUSPENDED CEILING MOUNTED EMERGENCY LIGHT

Sure-Lites. Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. IB505037EN Important Safeguards

Installation And Operation Instructions For FHSCP-UNV Series Emergency LED Drivers Models: FHSCP-UNV-5WL, 7.8WL, 10.7WL, 13.

UL AND CODE COMPLIANCE

3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

SAVE THESE INSTRUCTIONS

KT-EMRG-1400-SL /B. 3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

Cat# DC LED Array Emergency Driver

EMIU 720W Mini Inverter

MAINTAINED LED EMERGENCY CEILING MOUNT SPOTLIGHT

Installation And Operation Instructions

LIGHTPLANE 1 RECESSED - LP1R

INSTALLATION AND OPERATING INSTRUCTIONS

MAINTAINED LED CIRCULAR EMERGENCY CEILING LIGHT

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

Round or Square Type Low-Profile Housing with Toroidal Transformer for Flangeless Trims E3_LF-HDSM-WR_ 1.0

MaxLite LED UTILITY WRAP FIXTURES

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

BAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by:

Ivalo Finiré 3 LED Recessed Lighting Installation Instructions

When using electrical equipment, basic safety precautions should always be followed including the following:

SAVE THESE INSTRUCTIONS

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

LED Recessed Troffer Retrofit Kit

FLUORESCENT EMERGENCY BALLAST Lumens. When using this lighting device safety precautions should be followed at all times

Installation And Operation Instructions

D3 INSTALLATION GUIDE

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

Installation Instructions and User Manual For. 100 Watt Inverter Power System

SAVE THESE INSTRUCTIONS

Sure-Lites LPXC SERIES. Input Voltage Input Power 19 3/4" " /8" /8" 54 13" /2" 191

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

INSTALLATION INSTRUCTION W Track Recessed 120V Flangeless

Cordless Sweeper. OWNER S MANUAL Model: CFT Volt DC. Made Exclusively for ALDI Inc. Batavia, IL.,

MODEL ELC-12/40-CVM-D BATTERY CHARGER

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

Florham Park, NJ USA Call (ASCO) for sales or service

Round or Square Chicago Plenum Hi-lume Wall Wash Housing with LED Lamp for Flanged Trims E3_F_-L_WC-HL 1.0

LiteBox /FireBox / Operating Instructions. (Rechargeable) 99 Washington Street Melrose, MA Phone Toll Free

Installation Instructions: External-Driver SEP T8 LED Tube Lamp

Prismpack V, Prismalume V, Large Prismpack, Large Prismalume

Schaltgeräte GmbH GmbH Geschäftsbereich Leuchten

TOYOTA RAV TVIP V3

Dry Contact Closure Interface

82V LITHIUM-ION BATTERY CHARGER GC 400

SAVE THESE INSTRUCTIONS

NON MAINTAINED TWIN SPOTLIGHT WALL MOUNT LED EMERGENCY LIGHT

Installation And Operation Instructions

Electric Vehicle Charging Station

Zip FlushMaster Solo Water Saver Urinal Flushing System Keeps Urinals Clean & Reduces Water Wastage

Installation Instructions & Users Manual

Service Manual. Model Number: DF2426GB DF2426SS DF2550 DF2562. UL Part Number to 500

PIL0478 ISSUE 01/ 07/16

Lumencia. LLMPS SERIES Micro Power Systems. Multi-Unit Residential Lighting. Job Name: Type:

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

UV8 & UV90 SERIES INSTALLATION INSTRUCTIONS

Round or Square Type Non-IC Adjustable Housing with Toroidal Transformer for Flangeless Trims E3_L_-HANM_ 1.7

Installation Instructions BLTR and 2BLTR Relight Assembly

FUNTRONIX SCORE-N-TIME TM ULTRA-LARGE PORTABLE BASEBALL SCOREBOARD OPERATING MANUAL. Model SNT-800BB

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

Single Unit Rapid Charger FOR RECHARGEABLE TWO-WAY RADIO BATTERIES

VECTRIX VX-2 SERVICE MANUAL. Version 1.0/May 2011 VECTRIX, LLC

CODE MANDATED INTERIOR EMERGENCY LIGHTING:

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Touchstone TB130 DC Output UPS

Installation Instructions 4 Gravity Enhanced Color Adjustable

FHSCP-UNV-10P-L-SD INSTALLATION INSTRUCTIONS

Optimal Series. Automatic Transfer Switch. Installation and User Manual for the OPT2225 Automatic Transfer Switch. Full Version

INTEGRID TRACK (120V) SPECIFICATIONS

Transcription:

1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. MIRRORLITE RECESSED EMERGENCY LIGHTING INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS Before wiring to power supply, disconnect power at fuse or circuit breaker. Disconnect A.C. power before servicing. Refer to wiring instructions sheet for proper connections. Consult your local building code for approved wiring and installation. Do not use outdoors. Do not mount near gas or electric heaters. Equipment should be mounted in locations and at heights where it will not readily be subject to tampering by unauthorized personnel. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. Caution: Halogen cycle lamps are used in this equipment. To avoid shattering: Do not operate lamp in excess of rated voltage, protect lamp against abrasion and scratches and against liquids when lamp is operating, dispose of lamp with care. Halogen cycle lamps operate at high temperatures. Do not store or place flammable materials near lamp. Do not use this equipment for other than intended use. Servicing of this equipment should be performed by qualified service personnel. SAVE THESE INSTRUCTIONS 3161 State Road Bensalem PA 19020 U S A Telephone: (215) 244-4204 Fax: (215) 244-4208 www.evenlite.com

BACKBOX INSTALLATION DO NOT INSTALL SHELF INTO BACKBOX UNTIL WIRING IS COMPLETE MOUNTING BRACKET (4) BAR HANGERS TELESCOPING BAR HANGER (2 sets) Assemble telescoping Bar Hangers as shown. Both Notches on the same end. (8) (8) (4) (4) CARRIAGE BOLT Notch is near outside flange (4) B-CLIP HARDWARE KIT Wire Nut (3) (2) BAR HANGER MOUNTING CHANNEL ROUGH-IN CEILING MOUNT Bar Hangers are adjustable from 13-1/2" to 30 SUPPORTING MEMBERS MUST BE ABLE TO SUPPORT A LOAD OF AT LEAST 50 LBS. Attach Bar Hangers to backbox sides or top/bottom using carriage bolts and wing nuts supplied. Wing nuts should be inside backbox if height adjustment will be necessary from below ceiling. If access for height adjustment will be available from above, wing nuts should be outside backbox. B-Clip T-Bar or Angle Mtg. Bracket Screwed or nailed to Joist Wing Nut Mtg Brackets can be used with hanger bars to span any width up to 30 on top/bottom or sides of Back Box Pipe Hanger Supplied by Others Suspended Ceiling Support WOOD JOIST Attach Mounting Brackets directly to Back Box or if additional length required, to Bar Hangers as shown and adjust Bar Hangers to fit against joists. Fasten to joists with nails or screws SUSPENDED CEILINGS Attach Mounting Brackets and B-clips to Bar Hangers as shown and fasten securely to T-bars, angles, or pipe hangers.

ROUGH-IN WALL MOUNT Attach Bar Hangers to backbox top and bottom using carriage bolts and wing nuts supplied. Wing nuts should be inside backbox. Align backbox so lamphead opening is flush, or slightly behind inner surface of wall material. WOOD STUDS: Fasten Mounting Brackets to ends of Bar Hangers as shown and adjust to fit against studs. Secure with nails or screws supplied by others. METAL STUDS: Installation is the same as for wood studs except that sheet metal screws (supplied by others) should be used to fasten the hanger brackets to the studs. These screws should have a minimum pullout rating of 50 pounds. CLOSE-IN CEILING OR WALL MOUNT DRY WALL: Cutout hole in ceiling material should be 13-1/2" by 6-3/4". Align backbox so lamphead opening is flush, or slightly behind lower ceiling surface. WET WALL: Plaster flush up against lamphead opening. Lamphead wall opening Mtg. Bracket Screwed or nailed to stud WIRING INSTRUCTIONS DE-ENERGIZE BRANCH CIRCUIT AT BREAKER PANEL Select and remove desired knockout(s) for AC power input with at least 12" of AC power leads extending into inside of backbox. Secure cable with approved wire clamp and make connections using wire nuts supplied. Connect wires per local codes. Connect to transformer as follows: BLACK Lead for 120V or ORANGE Lead for 277V (CAP UNUSED LEAD) WHITE Lead for Neutral Connect GREEN/YELLOW Lead for GROUND. Dress AC and Ground wires down to bottom of backbox. DO NOT REAPPLY POWER UNTIL FINAL SETUP Back Box Rear View Back Box Shelf Ground Wire Remote Connection Knockout AC Input Knockouts INSTALL BACK BOX SHELF Feed transformer secondary cable (with connector) through hole in shelf and insert shelf into backbox with position of front and top indicated by label. Snap shelf into retaining slots in backbox. See MAINTENANCE for instructions on removing backbox shelf. Transformer Secondary Cable Note: Notches must be toward opening Back Box Internal View Transformer Primary Wires Back Box Shelf Installed Location

BATTERY INSTALLATION THIS PRODUCT IS SUPPLIED WITH A CHOICE OF 3 TYPES OF BATTERY SOURCES: SEALED LEAD CALCIUM (LC) NICKEL CADMIUM (Ni-Cd) NICKEL METAL HYDRIDE (Ni-MH) Sealed Lead Calcium Battery Depending on the product wattage and run-time ratings, there may be 1, 2 or 3 Batteries used. Insert Battery(s) ( TERMINALS OR CONNECTORS FACING OUT) through Lamphead opening. Allow Transformer Cable to extend out through Lamphead opening. Red Blk Red Blk Red Blk Battery(s) should be fully bottomed on Back Box Shelf. Attach Battery Cable to Battery(s) ensuring that proper polarity is observed. To PC Board Battery Connector Transformer Cable Battery Cable NOTE: Disconnected Battery must be recharged within 120 days. Nickel Cadmium or Nickel Metal Hydride Battery LAMPHEAD INSTALLATION Attach left side Lamphead Retaining Clip (viewed from Lamphead opening) into slots in Lamphead Frame, ensuring that Lamphead is oriented so company logo is closest to Battery. Allow right side of Lamphead to remain free for access to cable connections. Connect 3 pin Transformer Cable and 2 pin Battery Cable to matching sockets on Printed Circuit Board. NOTE: Once Battery is connected, unit must be energized within 30 days. Battery Cable Attach right side Lamphead Retaining clip into slots in Lamphead Frame. Access to retaining clip is through right side door. Door may be either manually opened (against spring pressure), or by pushing and holding the TEST button. TEST button must be held for 4 seconds (until the doors begin to open). The TEST button method is active only when AC power is not connected. Transformer Cable Slots in Lamphead Frame

ON-SITE PAINTING The doors and frame have been factory painted. If a new finish is applied, extreme care should be taken that a seal is not formed between the door frame and doors, which may hinder the free operation of the door mechanism. If the finish is sprayed on, we suggest that a thin cardboard or plastic strip be inserted between the doors and frame to prevent a paint seal. The indicator light, test switch and I.R. sensor should also be masked. After the new finish is applied, a sharp edge such as a single edge razor or utility knife should be inserted in the opening between the doors and frame, and run around the doors to ensure no seal is formed. Remove paint seal if new finish is applied SETUP AND OPERATION REAPPLY POWER AND NOTIFY THE AUTHORITY HAVING JURISDICTION ALLOW BATTERIES TO CHARGE FOR AT LEAST 72 HOURS BEFORE OPERATING UNIT. STATUS INDICATOR The STATUS indicator showing RED indicates that the Batteries are being charged. The indicator showing GREEN indicates fully charged Batteries. Infra Red Sensor Test Switch Status Indicator TEST SWITCH The TEST SWITCH is used to simulate failure of AC power. It can perform a USER test for 30 seconds or 90 minutes. By pushing the Switch for 1 second, the Doors will open and the Lamps will illuminate for 30 seconds. If the Switch is pushed for 4 seconds, and the STATUS indicator shows GREEN indicating fully charged Batteries, the Doors will open and the Lamps will illuminate for 90 minutes. If the Batteries are not fully charged, the 30 second test will run. In either mode, the USER test can be cancelled by pushing the switch again. INFRA RED REMOTE TESTING The USER test can be performed up to 50 feet away, by using the INFRA RED REMOTE TESTING TRANSMITTER. By aiming the TRANSMITTER at the SENSOR window and pushing either the 30 SECOND or 90 MINUTE button for 1 second, all the TEST SWITCH functions can be performed. RETRANSFER DELAY A 15 minute retransfer delay is available as a factory option. This option will keep the unit operating on battery backup for 15 minutes after power is restored. This feature allows HID lamps to warm up before the emergency lights are extinguished. FUSED REMOTE OUTPUT LEADS FUSED REMOTE OUTPUT LEADS can be installed as a factory option. These allow the use of remote 12 volt lampheads. The remote lamphead wattage added to the internal lamp wattage must not exceed the Output Load rating of the unit. Contractor will access leads through knockout in Backbox and make splice connections to leads. Remote Indicator REMOTE INDICATOR DISPLAY For applications where it is undesirable to have the indicator on the Lamphead, a Remote Indicator Display is offered as a factory option. The indicator is mounted in a switchplate panel which can be mounted in a standard 2 Switch Box supplied by others. Interconnecting wires should be AWG 22 or larger with a maximum run of 100 feet. Suitable cable would be UL Type CL2 Thermostat Cable.

LAMP ADJUSTMENT MIRRORLITE Model MIR-SD has 2 sets of 4 fixed lamp positions, which combined with adjustable mirrored door angles, provide optimum lighting patterns. Fixed lamp positions ensure that lighting patterns are not disturbed by relamping. Lampholder position is changed by squeezing Lampholder Bracket to release, and replacing in new position. CEILING MOUNT The product has been shipped with the lampholders installed in Lamp Position #1. This Lamp Position provides lighting patterns for most ceiling mount applications in which the fixture is on the same axis as the path of egress. The lighting pattern from one or both lamps can be shifted off-axis by changing one or both lampholders into Lamp Positions #2 or #3. Lamp Position #1 Squeeze Bracket to Release Lamp Position #3 For Off-axis beam WALL MOUNT Lamp Position #2 is used for Wall Mount applications where the path of egress is adjacent to the mounting wall. For applications where the path of egress is away from the mounting wall, the lampholders can be changed into Lamp Position #4. Lamp Position #2 For Off-axis beam Lamp Position #2 Standard Wall Mount Position For Longer Throw Lamp Position #4 DOOR ANGLE ADJUSTMENT Door angle adjustment is accomplished by turning the door adjustment screw. Door angle is adjustable between 65 and 85 degrees. The closer the door angle is to 85 degrees, the shorter the throw of the beam. If desired, each door angle can be adjusted independently, providing a non-symmetrical beam pattern. To access the door adjustment screw, the door may be manually opened (against spring pressure). If AC power is disconnected, the TEST button may be pushed and held for 4 seconds to open the doors. Door Angle Adjustment Screw Turn screw clockwise to adjust door angle Toward 85 degrees for short throw beam.

SELF-TESTING / SELF-DIAGNOSTIC This unit meets the requirements of NFPA 101 for Periodic Testing of Emergency Lighting Equipment. It provides visual indication of unit malfunctions including: Battery Fault Charger Fault Transfer Fault Lamp Fault Door Fault An automatic self-test and diagnostic function will be performed every 28 days. The doors will open for approximately 1 second and then close, without the lamps turning on. Following this, a load test will be performed for 29 minutes checking for a lamp, battery or transfer fault. This test will be performed only if the battery is fully charged. If not, the test will automatically reschedule. The charger function is monitored continuously. A manual user test can be performed for 30 seconds or 90 minutes. By pushing the TEST Switch for 1 second, the Doors will open and the Lamps will illuminate for 30 seconds. If the Switch is pushed for 4 seconds, and the STATUS indicator shows GREEN indicating fully charged Batteries, the Doors will open and the Lamps will illuminate for 90 minutes. If the Batteries are not fully charged, the 30 second test will run. In either mode, the user test can be cancelled by pushing and holding the TEST Switch for 1 second after the lamps come on. The manual user tests can also be initiated by the INFRA RED REMOTE TESTING TRANSMITTER. STATUS DISPLAY SIGNALS FUNCTION ACTION Continuous Green Battery in Float/Trickle Charge None Continuous Red Battery High Charging Wait for Green Status Flashing Green In Test Mode Wait for Test to Complete Alternate Red and Green Insufficient Charge for User Test Wait for Full Charge Red - One Blink ON / Pause Transfer System Failure Factory Service Red - Two Blinks ON / Pause Battery Failure Check Connections / Replace Battery Red - Three Blinks ON / Pause Charger Failure Factory Service Red - Four Blinks ON / Pause Door Failure Check for Paint Seal Red - Five Blinks ON / Pause Lamp Failure Replace Lamp

MAINTENANCE MIRRORS When required, clean with WINDEX glass cleaner or equivalent, using lint-free non-abrasive soft cloth. REMOVAL OF BACKBOX SHELF Press in locking tabs to remove shelf Backbox shelf can be removed from backbox by pressing in 2 locking tabs on either the front or rear face of backbox and sliding shelf toward lamphead opening. LAMP REPLACEMENT Before replacing lamps, disconnect power at breaker panel and allow lamps to cool. Push and hold TEST switch for 4 seconds (until doors begin to open). Grasp socket so aiming position is not disturbed. Be sure replacement lamp is totally seated in socket. Refer to replacement lamp part number. Use only specified replacement lamps. The self-diagnostic system learns the lamp wattage when the unit is initially powered. It is therefore necessary to replace the lamps with the same wattage as was initially learned, or else the system will report a defective lamp. If it becomes necessary to change the lamp wattage, within the ratings of the unit; this can be accomplished by disconnecting power at the breaker panel and unplugging the Battery Cable. When power at the breaker panel is reconnected and the Battery Cable is replugged, the system will learn the new lamp wattage. BATTERY The battery supplied in this unit requires no maintenance. However, it should be periodically tested (see TEST) and replaced whenever it will no longer operate the emergency lamps for the durations specified. Replace using the BATTERY INSTALLATION procedure. Refer to replacement battery part number. Use only specified replacement batteries. Used batteries may not be disposed of in the municipal solid waste stream. Arrangements for recycling Sealed Lead Calcium batteries can be made at 1-323-278-1900. For information on local recycling drop off points for Nickel Cadmium and Nickel Hydride batteries, call 1-800-BATTERY. Z410027