FILTERS. PUMP CARE - Suction filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW

Similar documents
FILTERS. TANK CARE - Return filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW

RETURN FILTERS. MATERIALS Head: Aluminium alloy Spin-on cartridge: Steel Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass

RETURN FILTERS. MATERIALS Head: Aluminium alloy Cover & bowl: Polyammide Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass

FPG-MDS PRESSURE FILTERS MATERIALS PRESSURE BYPASS VALVE WORKING TEMPERATURE COMPATIBILITY (ISO 2943) HYDRAULIC DIAGRAM.

PRESSURE FILTERS. BYPASS VALVE Setting: 170 kpa (1,7 bar) ± 10% WORKING TEMPERATURE From -25 to +110 C

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

D e s c r i p t i o n

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T )

FILTERS. TANK CARE - Return filters TECHNICAL DATA DOUBLE PORT MODEL ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES

SPIN-ON FILTER - LOW PRESSURE LINE

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

Pressure: Max working 110 bar (1600 psi) (acc. to NFPA T ) Burst 330 bar (4800 psi) (acc. to NFPA T ) Wire mesh µm

Connection Ports: 3/4 1 1/4 BSP (other thread options on request)

Connection Ports: 3/4 1 1/4 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

Connection Ports: 1/2 1 1/2 BSP (other thread options on request) aluminium alloy NBR (FKM on request)

SERIES SF2-250 SUCTION FILTER. Flow rate to 45 gpm

A complete line of pressure differential visual and electrical indicators are available with this series of filters.

Pressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi)

Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T ) Burst 840 bar (12200 psi) (acc. to NFPA T )

MPS/MST SERIES SPIN - ON FILTER SUCTION - RETURN. Maximum working pressure 12 bar. Flow rates to 300 l/min

Pressure: Max working 160 bar (2300 psi) (acc. to NFPA T ) Burst 480 bar (6900 psi) (acc. to NFPA T )

Filtrec elements are tested also according to ISO 2942, ISO and ISO 3968

SERIES SF2-500 SUCTION FILTER. Flow rates to 225 gpm

Pressure: Max working 420 bar (6000 psi) (acc. to NFPA T ) Burst 1260 bar (18300 psi) (acc. to NFPA T )

Pressure: Max working F280 D12x port size 1/2 & 3/4 : 420 bar (6000 psi) Burst F280 D12x port size 1/2 & 3/4 : 1260 bar (18000 psi)

A complete line of pressure differential visual and electrical indicators are available with this series of filters.

D e s c r i p t i o n

SRK-COMBO. Return & Suction Filters Low Pressure Filter In-Tank up to 10 bar. Filter Elements Emergency Suction

Low Pressure Filters

THE IMPORTANCE OF AN EFFICIENT FILTRATION

FBK-FRCA. Return Line Filters Low Pressure Filters In-Line up to 10 bar. Mix&Match to Get What You Need

MPF filters within this range are suitable for flow rates up to 750 l/min.

In line high pressure filters. HF 725 series

Fluid Cooling Industrial COLW Series

In line high pressure filters. HF HF 761 series

Series PD directly operated solenoid valves

LMP series

Return Line Filters. Section Index

In line high pressure filters. HF 735 series

HIGH PRESSURE FILTERS

22PD/32PD Series High Pressure Duplex Filters Max 260 l/min bar

LS 025 LS 035 In-line mounting Connection up to G¾ / -12 SAE Nominal flow rate up to 33 l/min / 8.7 gpm

ES 134 ES 144 Tank top mounting Connection up to SAE 1½ Nominal flow rate up to 130 l/min

The range of products is completed by a number of accessories, including:

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

Series PD directly operated solenoid valves

FILTERS. Accessories. CFA - Filling plugs. CBA-CBB - Air breathers. CSF - Filling plugs with threaded air filter. CLA - Visual level indicators

High Pressure Filters. 15P/30P Series. MAX 200 I/min bar. High pressure filters

HIGH PRESSURE FILTERS

ES 074 ES 094 Tank top mounting Connection up G1¼ Nominal flow rate up to 80 l/min

Type EV224B. Servo-operated 2/2-way solenoid valves for high pressure air. Data sheet

Series RFL In-Line Filter

Servo-operated 2/2-way solenoid valves for high pressure

Series RFLD Duplex In-Line Filter

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM

SPIN-ON FILTERS & ELEMENTS

Return Line Filter RFM with 4-Hole Mounting

HIGH PRESSURE FILTERS

PUMP SIZE Flow rate at 1500 rpm lt/min Operating pressures bar

Servo-operated 2/2-way solenoid valves Type EV220A

HIGH PRESSURE FILTERS HF4P Series Inline Filters 5000 psi up to 120 gpm

LMP series. 305 Low & Medium Pressure filters MULTIPORT. Maximum pressure up to 80 bar - Flow rate up to 200 l/min

LDP & LDD series Filter element according to DIN Maximum working pressure up to 6 MPa (60 bar) - Flow rate up to 330 l/min

PRESSURE FILTER Series HPV DN 25 PN 420

Duplex Pressure Filters

THE IMPORTANCE OF AN EFFICIENT FILTRATION

HIGH PRESSURE FILTERS DFFX Series Reverse Flow Differential Pressure Optimized Filters 6090 psi up to 160 gpm

FHF325 series. Filter housing according to SAE J2066 for HF4 filter elements. High Pressure fi lters

HIGH PRESSURE FILTERS

RF2 Maximum pressure 20 bar F l o w r a t e s t o l / m i n

Low Pressure Filters

DIN Filter element according to DIN Low & Medium Pressure filters. Maximum pressure up to 60 bar - Flow rate up to 330 l/min

LOW PRESSURE FILTERS RF Series In-tank / Inline Filters 360 psi up to 400 gpm

DG 023 DG 024 DG 025 DG 041 DG 042. Clogging Indicators

CLOGGING INDICATORS SUMMING-UP DESCRIPTION

525 Stainless steel high pressure filters. FZP series. Maximum pressure up to 420 bar. Stainless steel high pressure fi lters

Servo-operated 2/2-way solenoid valves with isolating diaphragm Type EV222B

Inline filters NF NF 1350 NF 330 NF 750 NF 500 NF FILTER SPECIFICATIONS Nominal pressure

Return Line Filter HF4R up to 450 l/min, up to 10 bar

Block mounting filter, for vertical flange-mounting

Return / Suction fi lters In-line. LMP 124 series MULTIPORT. Maximum pressure up to 80 bar - Flow rate up to 200 l/min. Return / Suction fi lters

In-Line Filters. Section Index. High FPK

VPPM /110 ED VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

Return Line Filter RF

HIGH PRESSURE FILTERS Series HF2P

Angle Seat Valve /2" up to 3"

High Pressure fi lters. FHP series. Maximum pressure up to 420 bar - Flow rate up to 750 l/min. High Pressure fi lters

Inline Filter DMG DMG 080 DMG 045 DMG FILTER SPECIFICATIONS. Temperature range -10 C to +100 C Material of filter housing

Line filter with filter element according to DIN 24550

HYDRAULIC AND LUBE OIL FILTERS RFM Series

LOW PRESSURE FILTERS RFM Series In-Tank Return Line Filters 145 psi up to 224 gpm

FMP IN-LINE FILTER SERIES. Maximum working pressure 250 bar. Flow rate to 500 l/min

Return Line Filter RFM with 4-Hole Mounting

SINGLE ACTING METRIC RANGE

FNA 045 Operating pressure up to 7 bar / 101 psi Nominal flow rate up to 45 l/min / 12 gpm

Suction Filter SF/SFM/SFF and Suction Filter Elements S/S..

MEDIUM PRESSURE FILTERS

Transcription:

FILTERS HYDRAULIC DIVISION - Suction filters SD TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW SPARE PARTS ORDERING INFORMATION DINSIONS OF THE FILTER ELENT

FILTERS HYDRAULIC DIVISION SD MATERIALS Cover & housing Bypass valve Seals Indicator housing COMPATIBILITY Anodized aluminium alloy Polyammide Nitrile NBR (FKM - on request fluoroelastomer) Brass Full with fluids: HH-HL-HM-HR-HV-HG (according to ISO 6743/4). For fluids different than the above mentioned, please contact our Sales Department. PRESSURE 6 R A/F 3 mm Indicator port Collapse, differential for the filter element BYPASS VALVE Setting 145 (1 bar) 5 (.35 bar) +/-1% H1 H7 H2 H4 D1 D 3 H5 H6 H3 WORKING TEMPERATURE From -15 to +23 F E1 D5 D4 9 D2 D1 D2 D3 D4 D5 E1 H1 H2 H3 H4 H5 H6 H7 R Weight Ibs FRD 11 1/2 3.74 3.29 3.54.22 1.69 6.3 2.46 3.78 1.24.16.12 3.78 4.13 2.7 FRD 21 3/4 5.43 4.76 5.4.26 4 7.52 4.13 3.94 2.5.24.12 5.7 4.33 5.5 FRD 31 1 6.6 5.31 5.79.26 2.64 9.84 5.51 4.61 2.48.31.16 7.75 6.1 7.8 FRD 41 1 1/2 7.9 6.38 6.85.33 3.23 12.72 6.97 6.1 3.23.31.16 1.59 9.45 13.7 FRD 51 2 1/2 1.83 9.33 1..41 4.63 14 8.58 7.56 3.58.39.31 12.59 1.83 3. FRD 61 3 1/2 1.83 9.33 11.81.57 7.1 2 = 9.76.39.2 = 2.67 13.6 Tank cut out = D3 + 1mm.

ORDERING AND OPTION CHART S D F FILTER COMPLETE FAMILY NOMINAL SIZE & LENGTH ELENT FAMILY SIZE & LENGTH E S D PORT TYPE B = BSP thread N = NPT thread S = SAE thread F = SAE flange 3, metric screws D = SAE flange 3, UNC screws PORT SIZE 4 = 1/2" 6 = 3/4" 8 = 1" 12 = 1" 1/2 2 = 2" 1/2 28 = 3" 1/2 BYPASS VALVE W = without A = 5 (,35 bar) SEALS N = nitrile NBR F = FKM Fluoroelastomer FILTER DIA = metal wire mesh 6 = metal wire mesh 9 = metal wire mesh 25 CLOGGING INDICATOR 8 = 1/8" seat, plugged 11 = vacuum gauge, bottom connection 9 = vacuum switch, N.O. contacts 9 9 9 9 9 9 91 = SPTD, vacuum switch 91 91 91 91 91 91 92 = vacuum switch, N.C. contacts 92 92 92 92 92 92 X ACCESSORIES X = no accessory available SEALS N = NBR F = FKM FILTER DIA = w. mesh 6 = w. mesh 9 = w. mesh 25 CLOGGING INDICATORS 1. ø 1.57 A/F 24 mm 3.22 PG9 A/F 27 mm A/F12 mm 1/8 BSP 1/8 Ø.87.12.39 1/8 1 4 2 Series 11: vacuum gauge Series 9 (N.O. contacts) Series 92 (N.C. contacts) vacuum switch - max voltage 22V ca 5-6 Hz max current.5a resistive,.25a inductive switching power 1VA, setting 4.4 (.3 bar) Series 91: SPDT, vacuum switch max voltage 25V - 5Hz max current 6A resistive,1a inductive protection IP65 setting 2.9 (.2 bar)

PRESSURE DROP ( p) CURVES The Assembly Pressure Drop ( p) is obtained by adding the pressure drop values of the Filter Housing and of the Clean Filter Element corresponding to the FILTER HOUSING PRESSURE DROP (mainly depending on the port size) considered Flow Rate and it must be lower than.4 (.3 bar)..4.6.3.4.2.3 1/2" 3/4" FSD 11-21-31 1".4.6.3.4.2.3 1 1/2" FSD 41-51-61 2 1/2" 3 1/2".1.2.1.2 13 26 4 53 66 79 53 15 159 21 263 316 CLEAN FILTER ELENT PRESSURE DROP (depending both on the internal diameter of the element and on the filter media).4.6.3.4 ESD 11.4.6.3.4 ESD 21.4.6.3.4 ESD 31.2.3.2.3.2.3.1.2.1.2.1.2 4 8 12 16 2 24 4 8 12 16 2 24 13 2 26 33 4.4.6.3.4.2.3.1.2 ESD 41.4.6.3.4.2.3.1.2 ESD 51.4.6.3.4.2.3.1.2 ESD 61 13 26 4 53 66 79 26 53 79 15 132 159 N.B. All the curves have been obtained with mineral oil having a kinematic viscosity 3 cst and specific gravity.9 ; for fluids with different features, please consider the factors described in the first part of this catalogue. 53 15 159 21 263 316 When selecting the filter size, these curves must be taken into account if it is foreseen that any flow peak is to be absorbed by the bypass valve, it also BYPASS VALVE PRESSURE DROP must be of proper configuration to avoid pressure peaks. The valve pressure drop is directly proportional to fluid specific gravity..6 FSD 11.6 FSD 21-31.6 FSD 41.6 FSD 51-61.45.45.45.45.3.3.3.3.15.15.15.15 4 8 12 16 2 24 13 2 26 33 4 13 26 4 53 66 79 53 15 159 21 263 316 N.B. All the curves are obtained from test done at the UFI HYDRAULIC DIVISION Laboratory, according to the specification ISO 3968. In case of discrepancy, please check the contamination level, viscosity and features of the fluid in use.

CROSS FUNCTIONAL VIEW STRONG CONSTRUCTION The strong filter housing makes the FSD filters particularly suitable for applications where each component must provide the highest reliability. CLOGGING INDICATOR A visual or electrical indicator allows monitoring of the element condition, and gives an indication of the proper time for replacement. The port for the indicator is a standard feature. FLEXIBILITY OF ASSEMBLING A second inlet port, supplied plugged, permits you to easily solve special installation needs. NO LEAKS The end caps with captive O-ring ensure a perfect sealing between filter element and housing. SPARE PARTS ORDERING INFORMATION (from the code of the complete filter, fill the digits corresponding to the boxes) C Filter housing B S D XX X Cover S S D X X X X X XX Head S S D X XXXXX Seal kit S S D X X X X X XXXXX A B B A DINSIONS OF THE FILTER ELENTS Type ERD 11 ERD 21 ERD 31 ERD 41 ERD 51 ERD 61 A B C 2.5 3.9 1.1/.94 1.34 1.34 2.1 2.91 2.91/ 3.35 3.35 8.31 9.88 19.69 Area (in 2 ) Media M+ 38. 71.3 114.7 361.2 517.7 1528.3 Technical data subject to variations without prior notice.sd - USA - 7/25 UFI Universal Filter International - Hydraulic Division: 9337 Ravenna Road, Unit G - Twinsburg, OH 4487 Phone (33) 4518 - Fax (33) 45181 - E-mail: ufifilters@uhiltd.com UFI HYDRAULIC DIVISION - PLANET FILTERS S.p.A. via S.Chierico, 24-246 Bolgare BG - Tel. 35 4493831 - Fax 35 843743 e-mail: info@ufifilter.it - http://www.ufifilter.com