A flexible, reliable and affordable drive for 1/4 through 2 HP DC applications

Similar documents
DC3N Non-Regenerative DC Drives

MaxPak Plus Analog DC V S Drive

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

DC1 V*S DRIVES. D a1 =-=- v_e_s DC1 V*S DRIVES. REL.IANCEll'II ELECTR1c o. EFFECTIVE July 1,

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

Applications: Conveyors, machine tools and other applications requiring adjustable speed. Mult. Sym.

Fincor Series 2230 MKII/2240

1/6 through 5 HP Adjustable Speed, DC Motor Controllers

CONTROL FEATURES AVAILABLE OPTIONS

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

Applications: General purpose industrial use with permanent magnet or shunt wound DC motors. Description

WARNER ELECTRIC. Bronco II 160 Series DC Drives SUPPORTED BY DANA CORPORATION

SERIES 2335 SINGLE-PHASE ADJUSTABLE-SPEED DC MOTOR CONTROLLERS (1/6-2 HP)

Installation & Operation Manual

Boston Gear Ratiotrol DC Motor Speed Control

Series 2330MKII. Single-Phase. Adjustable-Speed. DC Motor Controllers (1/6 3 HP) BOOK 0958-B

1/4HP - 7.5HP 120/240/277 VOLTS 50/60HZ

Boston Gear Ratiotrol

TABLE OF CONTENTS SPECIFICATION CHART...8 RATIOPAX DCX/DCXplus BETA II BETAplus VEplus

DC3E Non-Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC M/N DC3N-12D AI M/N DC3N-12D-4X-010-AI

SERIES 2600/2610 SINGLE-PHASE ADJUSTABLE-SPEED DC MOTOR CONTROLLERS (1/6-5 HP)

5001TCP SPEED CONTROLLER

Graham. Vari Speed S1000 Instruction Manual. TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual

DC3R Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC

5001TCP SPEED CONTROLLER

RCP200 Series Motor Controls. Instruction Manual Model RCP Model RCP Model RCP202-BC1 Model RCP202-BC2 Model RCP205-BC2

Boston Gear Ratiotrol

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

CTi Automation - Phone: Fax: Web:

DC Variable Speed Drive Panel

SAFTRONICS DF8 PLUS SERIES

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

Boston Gear Ratiotrol DC Motor Speed Control


Installation and Operation Manual. *See page 6 for CE Information

MX1S Matrix Converter

Boston Gear Ratiotrol

Softstarters. Softstarters Power electronic brakes Type PEB

SOLSTART Instruction Manual

Description 1/8-7.5HP

Dimensions WxHxD [mm] Weight [kg]

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

REGAL-BELOIT SpinMaster AC Adjustable Speed Drives

INSTALLATION AND OPERATING INSTRUCTIONS REGENERATIVE DRIVE MODEL KBRG-255 (5HP) KB Part No FULL WAVE 4 QUADRANT FWD ACCEL REV ACCEL FWD CL

BRONCO VFD. October

DUAL SWIVEL REEL OPERATING INSTRUCTIONS

BLDC SPEED CONTROL INSTRUCTION MANUAL Line voltage Brushless DC control

INSTALLATION AND OPERATING INSTRUCTIONS REGENERATIVE DRIVE FULL WAVE 4 QUADRANT REV S/LT NLT R33 AC LINE FUSE ARMATURE F2 FUSE TB2

SECTION MOTOR CONTROL

DO NOT INSTALL, REMOVE, OR REWIRE THIS EQUIPMENT WITH POWER APPLIED.

Copyright 2013 Automationdirect.com Incorporated All Rights Reserved

Temperature Controllers

Crane Control Class 5010

Boston Gear Ratiotrol

Temperature Controllers

Focus 3N ¼ to 5HP Single Phase, Uni-Directional Non-Regenerative DC Drive

Boston Gear Ratiotrol

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

Boston Gear Ratiotrol DC Motor Speed Control

MELLTRONICS DRIVES. Single Phase Regenerative DC Drives ¼ HP TO 7½ HP INSTALLATION OPERATION MAINTENANCE

1333 (SERIES B & C) TROUBLESHOOTING GUIDE

Super Calendar. Heated rolls

WARNER ELECTRIC. Quadraline 7000 DC Drives SERVO CONTROLS STEPPER CONTROLS VOLTAGE CONDITIONING ENGINEERED SYSTEMS AC/DC DRIVES

Super Calendar. Heated rolls

BC141, BC142, BC142-5 & BC142-6 DC Control

Boston Gear. Adjustable-Speed Regenerative DC Motor Controllers. Installation and Operation Manual. Doc. No RBA-RG VEA-RG Series

56 FRAME & 56C FRAME FRACTIONAL MOTORS From WorldWide Electric

RVS-DN Digital Reduced Voltage Motor Starter

INSTALLATION AND OPERATION MANUAL SUPPLEMENT KBPC-225 (PART NOS & 9392)

User s Manual. SCR, Adjustable Speed Drives for DC Brush Motors

17429X.00 SERIES MODELS:

RBD Series. Installation and Maintenance Manual. An Altra Industrial Motion Company

CABINET REEL OPERATING INSTRUCTIONS

DC Drive Selection Guide

WDC CONTROL SERIES. Instruction Manual. Variable Speed DC Control

KBWS WHISPER DRIVE PULSE WIDTH MODULATED (PWM)

Center Winder Specification

KBPC-240D (Part Nos and 9342) Installation and Operation Manual Supplement

SECTION VARIABLE FREQUENCY DRIVE UNITS

RVS-AX Instruction Manual

SECTION MOTORS AND VARIABLE FREQUENCY DRIVES

Snap-Trol 183 Nema 1 Series

J1000 D E F I 1000 J1000 J1000 J1000 J1000

Series 5 Inverter OPEN CHASSIS MOUNT - SINGLE PHASE INPUT. For Catalog Nos. ID56F50-CO, ID5601-CO & ID5602-CO

GS2 Series - Introduction

Boston Gear RB Series

An American Control Electronics Brand RG500 SERIES USER MANUAL RG500UA RG500UA-PCM RG500A RG510UA RG510UA-PCM RG510A.

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

TABLE OF CONTENTS WARRANTY. 1 INTRODUCTION. 2 CONTROL FEATURES. 2 HEATSINK DIMENSIONS. 2 SPEEDPOT KIT ASSEMBLY. 3 MOUNTING PROCEDURE.

Power electronic brakes

KBIC SCR DC Motor Speed Controls

GS10 Series MODELS: GS10 GS10-R NEMA 4X SCR MOTOR CONTROLS. User s Manual

A6Z OPERATING MANUAL

Adjustable Torque Controls

RVS-DX Digital Reduced Voltage Motor Starter

WarninG TraDeMarkS Copyright 2013, 2018 Automationdirect.com Incorporated All Rights Reserved

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

TA-05/C. Instruction and Operation Manual. valid for art.-no.: F-TA-05/C-ISO. (start at modification No. 1601)

team master medium voltage solid state starters

Transcription:

A flexible, reliable and affordable drive for 1/4 through 2 HP DC applications DC2 drives combine application flexibility, compact size and reliability into an affordable adjustable speed package that delivers the performance you need for a wide range of industrial applications. The DC2 drive is equipped with a range of application adjustments including a single jumper reconnection to quickly and easily match the drive to incoming power. Motor horsepower selection, the choice of either armature voltage or speed feedback signals, and the choice of 7 VDC or 20.8 VDC/1000 RPM tachometer feedback is just as simple. Other application adjustments allow you to tailor drive performance to meet your requirements. A number of standard model number drives are available, which provide features for specific applications. These specific features include reversing, run/jog, process signal input of either 4-20 ma or 0-10 volts or a torque regulator to control shaft torque or web tension. STANDARD FEATURES Available in either open chassis, totally enclosed NEMA 12 or NEMA 4/4X construction. Operates from either local or remote operator controls for added mounting flexibility. (1) All circuitry - sequencing, regulator and terminals - packaged on a single, accessible surface mount design printed circuit board. Jumper reconnections adapt standard drives to match: - Line voltage, either 115 or 230 VAC, 50 or 60 Hz - Motor horsepower, from 1/4 through 2 - Desired feedback, either armature voltage or motor driven DC tachometer for nonreversing models only - Tachometer requirements: 7 VDC or 20.8 VDC per 1000 RPM designs - S curve or linear acceleration - Zero speed operation Application adjustments tailor drive performance to your needs: - Separately adjustable maximum and minimum speeds set speed limits - Adjustable current limit protects machinery, wiring and drive - Adjustable IR drop compensation improves speed regulation when using armature voltage feedback - Adjustable acceleration and deceleration rates for smooth starts, stops and speed changes Armature voltage, tachometer or armature current feedback 20:1 constant torque speed range 30:1 constant torque speed range with tachometer feedback Power cube contains all power semiconductors for reliability and improved maintenance time Full-wave, half-control power conversion with back diode for efficient power conversion, smooth armature current waveforms and cool motor operation over wide operating speed ranges Built-in half-wave field supply for operation of wound field motors Built-in surge suppressor helps protect semiconductors from line transients for better reliability Relay in control circuit prevents automatic restarting after power outage Run/Off switching arrangement allows positive disconnect of the motor from the plant line on a Stop command Two years from date of manufacture/one year in service full exchange warranty eliminates troubleshooting and returns you quickly to operation NEMA 4 s are F.D.A./U.S.D.A. approved, white epoxy finish on drive and motor (1) Reversing units are local control only D-115

DC2 DRIVES FOR SPECIFIC APPLICATIONS Standard model numbered DC2 drives provide just the right drive for those special applications. SERVICE CONDITIONS Elevation: Up to 3300 feet (1000 meters) Ambient Temperature - Enclosed Models: 32ºF to 104ºF - (0ºC to 40ºC) ADJUSTMENTS Maximum Speed (Percent of rated): under 50 to 100% Minimum Speed (Percent of rated): under 5 to 50% AC Drives Models DC2-40, DC2-50, DC2-70, DC2-80, DC2-90 and DC2-95 come with start/stop and speed input capability for basic applications. Model DC2-71 and DC2-91 come complete with forward-dynamic braking-reversing switch for simple reversing applications. Instrument Interface Models, DC2-42, DC2-52, DC2-72, DC2-82, DC2-92 and DC2-97 feature automatic/manual operation from either a grounded or ungrounded 4-20 ma or 0-10 volt DC reference (automatic) or speed potentiometer (manual). - Chassis Models: 32ºF to 131ºF (0ºC to 55ºC) AC Line Voltage Variation: +10% rated voltage AC Frequency: 48 to 62 Hz Atmosphere: Non-Condensing Relative Humidity 5 to 95% APPLICATION DATA Service Factor: 1.0 Maximum Load: 150% for 1 minute Current Limit (Percent of rated): adjustable to 150% Acceleration Rate: 0.3 to 40 seconds linear Deceleration Rate: 0.3 to 40 seconds linear IR Drop Compensation: 5 to 10% Digital DC Drives Analog DC Drives Model DC2-43 provides torque control using armature current feedback for applications requiring control of applied torque or tension. Models DC2-54 and DC2-74 combine torque control with instrument interface capabilities. Models DC2-40, DC2-50, DC2-80 and DC2-99 feature a basic speed control with start/ stop and run/jog. Model DC2-98 combines basic speed control with start/stop, run/jog and forward-dynamic braking-reversing capability. Speed Regulation: - Voltage Feedback: 2-5% (95% load change) - Tachometer Feedback: 1% (95% load change) Speed Range: 20:1 with armature voltage Feedback: 30:1 with tachometer feedback Feedback and reference potentiometer circuits are not isolated from main power. Isolation transformers are mandatory for tachometer feedback operation using a type RE020 20.8 VDC/1000 RPM tachometer (Model R20E8000). Consult instruction manual D2-3231 for other recommended or mandatory uses of isolation transformers and complete application information. Options & Accessories D-116

Drive Ratings Motor HP 1/4 1/3 1/2 3/4 Rated AC Line (Amps) (1) Input KVA 115 VAC INPUT 230 VAC INPUT DC Armature Voltage Rated Armature Current (Amps) Available Field Voltage Rated Field Current (Amps) 3.1 0.36 90 2.5 50 2 4.2 0.48 90 3.7 50 2 6.2 0.71 90 5 50 2 3.1 0.71 180 2.5 100 2 9.4 1 90 7.5 50 2 4.7 1 180 3.7 100 2 1 (2) 12.5 1.4 90 10 50 2 6.2 1.4 180 5 100 2 1-1/2 9.4 2.2 180 7.5 100 2 2 (2) 12.5 2.9 180 10 100 2 (1) Includes motor field current (2) DC2 Series 50 designs must be mounted to a metal plate 18 x 18 to meet 1 HP @ 115 VAC and 2 HP @ 230 VAC, or an optional heat sink (HS1-50) can be purchased. APPLICATION MATRIX Here are some basic guidelines for selecting an appropriate DC2 drive based on the type of application involved. Application Agitators Enclosure Chassis NEMA 12 NEMA 4/4X/12 Bottling Machines Conveyors Exercise Machines Extruders Feeders Indexers Material Handling Metering Pumps Mixers Ovens Packaging Machines Printing Presses Processing Machines Pumps Robotics Screen Presses Take-Ups Tapping Machines Welding Positioners All dimensions in inches (mm) D-117

Enclosed Design (DC2 Series 70, 80 and 90) Open Chassis Design (DC2 Series 40) Digital DC Drives Options & Accessories Analog DC Drives AC Drives Plate-style Open Chassis (DC2 Series 50) HS1-50 Heat Sink (For DC2 Series 50 Drives) D-118

PRICING (1) (3) 1/4-1 HP @ 115 VAC 90 VDC ARMATURE, 50 VDC FIELD (1) (3) 1/2-2 HP @ 230 VAC 180 VDC ARMATURE, 100 VDC FIELD Regulator Type Less Fuse Kit Normally carried in stock Open Chassis Basic Regulator with Linear Accel. Model Number Plate ler (3) NEMA 12 Enclosure With Operator Easy Clean NEMA 4/4X/12 Enclosure Without Operator With Operator List DC2-40U DC2-50U DC2-70U DC2-80U DC2-90U Basic with Run/Jog and Linear Accel. Model Number $330 $275 $375 $375 $395 List DC2-40U DC2-50U N/A DC2-80U DC2-99U Basic and Reversing with Linear Accel. Model Number $330 $275 $375 $450 List N/A N/A DC2-71U (4) N/A DC2-91U (4) Basic Instrument Interface with Linear Accel. and Decel. Model Number (2) $485 $510 List DC2-42U DC2-52U DC2-72U DC2-82U DC2-92U Basic and Reversing with Run/Jog and Linear Accel. $405 $300 $460 $460 $510 List N/A N/A N/A N/A DC2-98U (4) Torque Regulator with Linear Accel. Model Number List DC2-43U N/A N/A N/A N/A $370 Torque Regulator and Instrument Interface with Linear Accel. and Decel. Model Number (2) List N/A DC2-54U DC2-74U N/A N/A $300 $520 Note: Conduit hole plugs are standard on NEMA 12K designs. Conduit hubs are standard on NEMA 4/12 designs only. Conduit hubs for either design can be ordered through Renewal Parts by referencing Reliance Part Number 608826-2A. MODIFICATION/KITS Customer-Installed Fuse Kits The DC2 product line as standard comes without line fuses. If they are not to be supplied by the user, order the model number Fuse Kit below to match the DC2 drive you have selected. Drive DC2 Series Kit Model Number Kit List Open Chassis 40 F1DC2000 $65 Plate Chassis 50 F2DC2000 100 NEMA 12K 70 F2DC2000 100 NEMA 4/12 80, 90 F2DC2000 100 (1) Jumper selection for 115 VAC / 90 VDC or 230 VAC / 180 VDC. (2) Instrument Interface units also provide auxiliary control relay contact rated 0.6 Amps @ 125 VAC for customer use. (3) DC2 Series 50 Drive must be mounted to a metal surface 18 by 18 to meet 1 HP @ 115 VAC and 2 HP @ 230 VAC or an optional heat sink (HS1-50) can be purchased. (4) Switch reversing DC2 models include as standard an installed line fuse. Heat Sink Kit For DC2-50 Series HS1-50 List $100 Isolation Transformers $550 See page D-188 for selection and pricing of isolation transformers. Note: A transformer is mandatory for tachometer feedback operation using the Type RE-020 20.8 VDC/1000 RPM tachometer (Model Number R20E8000). The Type RE-007 (Model Number R07E1210) fully-isolated 7 VDC/1000 tachometer does not require an isolation transformer. Consult Instruction Manual D2-3231 for other recommended and mandatory use of isolation transformers. Remote Operator s Reliance offers a variety of remote operator control stations. Refer to page D-185 for selection and pricing information. PRODUCT PUBLICATIONS Data Sheets DC2 Drive: D-2885 Instruction Manual All DC2 Drives: D2-3231 Fuse Kit: D2-3250 DISCOUNT VS-3DC D-119