2.2.88 DESCRIPTION The Cruze ST LED series combines latch-less design, matte white paint after fabrication and frosted acrylic lens to deliver architectural appeal at unmatched price. This high performance LED troffer is constructed with 's the latest solid-state technology platform and delivers unprecedented energy savings, visual comfort and aesthetics at an incredible value. Cruze ST offers premium finishes and clean lines making it an ideal choice for commercial office spaces, schools, hospitals, and retail merchandising areas. Catalog # Project Comments Prepared by Metalux Date SPECIFICATION FEATURES Construction Die formed of code gauge prime cold rolled steel with full length die-formed stiffeners Unibody endplates attached with interlocking tabs and screws Hemmed side flanges Four auxiliary fixture end suspension points Integral rid-lock feature for endplates for added safety Optional earthquake clips Integrated Controls -V dimming to 1% standard WaveLinx sensor compatible for IoT capability LumaWatt Pro sensor compatible for IoT capability SVPD sensor compatible for out of the box functionality DLVP sensor and driver compatible for low voltage applications DALI 2., Lutron, and stepdimming LED and Light Engine LED s in 3K, 3K, 4K, or K at 8 CRI minimum and 9 CRI minimum TM21 life at 6, hours up to L94 and calculated L7 exceeds 29, hrs Drivers in 12-277V and 347V Color Tuning options with 's Vividtune Emergency Battery Options Optional 12-277V emergency battery in 7W or 14W 9-minute backup period for code compliance Test switch with laser pointer and testing from floor feature for ease of use EZ Key feature prevents accidental discharge during construction enerator transfer options Finish Multistage, iron phosphate pretreatment 9% reflective, matte white enamel finish Full fixture housing painted after fabrication Shielding Ribbed acrylic frosted lens standard Optional smooth acrylic frosted lens (S) Optional metal perforated acrylic lens (RDP) Compliance IC rated for insulation contact culus listed for damp locations RoHS compliant Tested to IESNA LM-79 and LM-8 Stated life tested to TM21 standards Can be used for State of California Title 24 high efficacy luminaire Warranty Five year warranty standard. Cruze ST 14CZ2 LED 1' X 4' LED TROFFER Specification rade Troffer 2-1/4" [6mm] * 11-11/16" [297mm] *Battery option increases total height by 1 inch. MOUNTIN DATA California Title 24 Non-Residential Compliant 11-11/16" [297mm] 4-1/2" [11m] 47-3/4" [1213mm] 2" [8mm] LOAD DATA (STOCK PRODUCT) CEILIN COMPATIBILITY Thd 6% Power Factor.99 Weight 9.9 lbs. Low Temp. Start -2ºC rid/lay-in Standard Concealed T Slot rid Ceiling Trim Exposed rid Standard Concealed T Standard Slot rid Standard Flange * *See Drywall Frame Kit Accessory in Ordering Information Section Safe and convenient means of disconnecting power
14CZ2 LED ORDERIN INFORMATION SAMPLE NUMBER: 14CZ2-39HE-UNV-L83-CD1-U Rating [Blank]= Standard ATW-SW4= Chicago Rated Cruze ST Series 14CZ2=1x4 Cruze ST High Efficacy Lumen Output 39HE=38 Lumens (7) 48HE=48 Lumens (7) 6HE=6 Lumens (7) Standard Efficacy Lumen Output 2=2 Lumens 2=2 Lumens 29=29 Lumens 3=3 Lumens 39=39 Lumens 44=44 Lumens Shielding [Blank]=Ribbed Frosted Acrylic Lens (standard) S=Smooth Frosted Acrylic Lens RDP=Smooth Lens with Round Pattern Insert Voltage (2) UNV=Universal Voltage 12-277 347V=347 Volt () 48V=48 Volt Low-voltage (Class 2) (C) Driver CD=-V Dimming Driver (1%-% Dimming) SR=Sensor-ready Dimming Driver for LWIPD1 option (1%-% Dimming) (B) LTD=Fifth Light DALI Driver (%-% Dimming) (E) LTHD=Fifth Light Dimming Driver (1%-% Dimming) (E) LV1=DLVP Dimming Driver (%-% Dimming) (C) SD=Step Dimming Driver (% or % Dimming) Options Emergency [Blank]=No emergency EL7W=7-watt, 12V-277V emergency battery pack installed (3) EL14W=14-watt 12V-277V emergency battery pack installed (3) ELV7W=7-watt, DLVP-compatible low voltage emergency battery pack installed (C) ELV14W=14-watt DLVP-compatible low voltage emergency battery pack installed (C) TR2=enerator Transfer Relay (4) ETRD=Emergency Transfer Relay with dimming control (4) CRI/ L83=8CRI, 3K L83=8CRI, 3K L84=8CRI, 4K L8=8CRI, K L93=9CRI, 3K L93=9CRI, 3K L94=9CRI, 4K L9=9CRI, K L83=8CRI 3K-K White Tuning (6) L93=9CRI 3K-K White Tuning (6) L8276=8CRI 27K-6K White Tuning (6) L9276=9CRI 27K-6K White Tuning (6) Flex [Blank]=No Flex A3/8-4/18DIM=3/8" Flex with -V Dimming Leads A3/8-2/18=3/8" Flex with line and common A3/8-/18DIM=Flex with -V Dimming leads and Blue for alternate wiring See below for details. Number of Drivers 1=1 Driver 2=2 Drivers LH=Lutron HiLume (LDE1 series) 1%-% EcoSystem Driver with Soft-on Fade to Black dimming (F) L=Lutron Series (LDE-Series) %-% EcoSystem Driver (F) W2A=White Tuning, 2 ch, Analog -V Intensity and Control (6) Integrated Sensing Systems [Blank]=No Sensor SWPD1=WaveLinx Wireless Integrated Sensor (A) (A), (8) SDWPD1=WaveLinx Wireless Integrated Sensor Dual Band LWIPD1=LumaWatt Pro Wireless Integrated Sensor (B) LDWIPD1=LumaWatt Pro Wireless Integrated Sensor Dual Band LWTPD1=LumaWatt Pro Wireless Tile-mount Sensor (B) SLVPD1=DLVP Low-voltage Integrated Sensor (C) (C), (8) SDLVPD1=DLVP Low-voltage Integrated Sensor Dual Band SVPD1=-V Stand-alone Integrated Sensor (D) (D), (8) SDVPD1=-V Stand-alone Integrated Sensor Dual Band (B), (8) Packaging U=Unit Pack PAL=Job Pack, out of carton PALC=Job Pack, in carton ACCESSORIES CZ2-EQCLIP-U=Cruze Plus "CZ2" Earthquake Clip Kit (4 clips per bag kit) (1) DF-14-W=1' x 4' Drywall Frame Kit SK-14-WT=1' x 4' Tall Surface Mount Kit ISHH-1=Programming Remote for Integrated Sensor (D) ISHH-2=Personal Control Remote for Integrated Sensor (D) NOTES: (1) An EQ rid Clip is recommended for all 9/16" ceiling systems. Four required per fixture. (2) Products also in non-us voltages and frequencies for international markets. (3) With integral test switch/indicator/laser test. For approximate delivered lumens multiply the lumens per watt of the desired fixture by the wattage of the emergency battery pack ( lm/w x 7=7 lumens). IES-format photometry for luminaire under emergency operation. Battery option increases total height by 1 inch. (4) Used to bypass local control during outage. Must be used in conjunction with UL 8 device (provided by others). TR2 option includes 2 relays on fixtures with dimming drivers. ETRD option only requires one relay when used on a dimming fixture. Must specify voltage as 12V or 277V when ordering these devices. 347 not. () 347 versions 6 lumens and below are with emergency options, LTHD and step-dim options or sensors are not. (6) White tuning provides correlated color temperatures () between 3K (warm) to K (cool) or 27K (warm) to 6K (cool). Must be used in conjunction with W2A driver only. Must be used with two (2) V dimming control channels, 1 color, 1 intensity. Not compatible with other control or sensor options. (7) White tuning not with this model. (8) Required for use with sensors and emergency options. Provides blank band on opposite side from sensor band to provide symmetric appearance. Integrated Sensing and Control System Options NOTES: Integrated options must be used in conjunction with the associated system and may not be compatible with other options or accessories. Please refer to the following: (A) Consult WaveLinx system pages for additional details and compatibility. (B) Consult LumaWatt Pro system pages for additional details and compatibility. (C) Consult DLVP system pages for additional details and compatibility. (D) Consult SVPD series system pages for additional details and compatibility. (E) Consult Fifth Light system pages for additional details and compatibility. (F) Consult Marketplace Options - Lutron system pages for additional details and compatibility. Compatible only with driver series shown, and may require two or more drivers. Requires field commissioning to operate or dim. Contact Lutron at www.lutron.com. Flexible Metal Conduit Options Flex options for -V dimming control, DALI dimming control, emergency and night light functions. 72-inch factory-installed and pre-wired to driver, fitted to luminaire housing access plate with 9 enclosed FMC connector. Not all options may be combined and installation ratings vary by type. A3/8-4/18DIM series notes: Factory installed dimming option 3/8 flexible metal conduit with 2-#18 power and ground wires and 2-#18 UL-listed jacketed -V +/- control wires. Meets UL 66, 83, 1479, 169, 181, 26. NEC 2.118, 3.22(C), 392, 396, 33, 1, 2, 3, 3, 4,, 18, 2, 3, 64, 72; Federal Specification A-A-944 (formerly J-C-3B); all applicable OSHA and HUD Requirements. UL Classified 1-, 2-, and 3-hour through penetration with applicable fire stop product (not included). May be surface mounted, fished and/or embedded in plaster. Cable tray and approved raceway rated, install per NEC ; Environmental Air-Handling Space Installation per NEC 3.22(C ). Specifications & Consult your Representative for availability and ordering information. SHIPPIN DATA Pallet Size Wt. 2"L x 49"W x 3."H 1' x 4' 22 lbs. 32
ENERY AND PERFORMANCE DATA BY CATALO NUMBER Standard Efficacy Versions Catalog Number Lumens Watts lm/w 14CZ2-2-UNV-L83-CD1-U 28 16.3 123 14CZ2-2-UNV-L83-CD1-U 2473 2. 121 14CZ2-29-UNV-L83-CD1-U 2879 24.3 119 14CZ2-3-UNV-L83-CD1-U 34 31.2 114 14CZ2-39-UNV-L83-CD1-U 3931 32.3 122 14CZ2-44-UNV-L83-CD1-U 411 38.3 118 High Efficacy Versions Catalog Number Lumens Watts lm/w 14CZ2-39HE-UNV-L83-CD1-U 396 29.3 13 14CZ2-48HE-UNV-L83-CD1-U 4823 36.9 131 14CZ2-6HE-UNV-L83-CD1-U 621 48.3 12 SHIELDIN LUMEN CALCULATOR Lumen Adjustment Factors S LUMEN MAINTENANCE RDP 1.6.6419 Multiplier 8 CRI 9 CRI 3K.994.83 3K 1..84 4K 1..84 K 1.6.82 Example of Lumen Adjustment Calculation 14CZ2-3-UNV-L93-CD1-U at 9CRI at 3K Lumen Adjustment Factor =.84 Total Light Output = 3,4 lm x.84 = 2,996 lm Efficacy = 2,996 lm 31.2 W = 96.1 lm/w 14CZ2 LED PHOTOMETRICS Version TM-21 Lumen Maintenance (6, hours) Theoretical L7 (hours) Standard > 8% > 131, High Efficiency > 94% > 29, 216 433 649 86 14CZ2-2-UNV- L83-CD1-U Dimming Driver Linear LED 3K Spacing criterion: (II) 1.19 x mounting height, ( ) 1.28 x mounting height Lumens: 249 Input Watts: 2.W Efficacy: 12 LPW Test Report: 14CZ2-2-UNV- L83-CD1-U.IES Coefficients of Utilization Effective floor cavity reflectance 2% Candlepower Angle Along II 4 Across 1 2 2 3 3 4 4 6 6 7 7 8 8 9 863 863 863 861 84 89 844 841 849 818 819 831 782 79 88 739 73 777 689 712 74 636 666 699 76 616 63 1 63 66 4 7 3 386 41 497 323 392 439 28 331 374 19 269 298 128 2 197 72 1 9 2 2 12 rc 8% 7% % 3% % % rw 7 3 7 3 3 3 3 RCR 1 2 3 4 6 7 8 9 2 3 9 8 7 6 4 119 119 119 119 116 116 116 116 111 111 111 6 6 6 2 2 2 9 4 96 6 2 98 94 97 94 91 93 91 88 9 88 86 84 99 9 83 77 96 88 82 77 8 79 7 81 77 73 78 7 71 69 9 79 71 64 87 77 7 64 74 68 62 72 66 61 69 64 6 8 82 7 61 4 8 69 6 4 66 9 3 64 7 2 61 6 2 49 7 62 3 47 73 61 3 46 9 2 46 7 4 49 4 43 7 6 47 41 68 47 4 3 46 4 2 4 4 44 39 37 64 1 42 36 63 42 36 48 41 3 47 4 3 46 39 3 33 6 46 38 32 8 46 37 32 44 37 32 43 36 31 42 36 31 29 6 43 34 29 42 34 29 41 34 28 4 33 28 39 33 28 26 3 39 31 26 1 39 31 26 38 31 26 37 3 26 36 3 26 24 22 4 7 7 14CZ2-29-UNV- L83-CD1-U Dimming Driver Linear LED 3K Spacing criterion: (II) 1.19 x mounting height, ( ) 1.27 x mounting height Lumens: 2863 Input Watts: 24.3W Efficacy: 117.8 LPW Test Report: 14CZ2-29-UNV- L83-CD1-U.IES Coefficients of Utilization Effective floor cavity reflectance 2% Candlepower Angle Along II 4 Across 1 2 2 3 3 4 4 6 6 7 7 8 8 9 4 4 4 1 994 983 979 988 92 93 967 911 919 94 861 877 94 82 829 862 739 77 813 672 716 762 61 64 74 26 91 64 42 2 79 37 46 9 31 386 437 227 313 348 11 231 226 82 129 7 28 23 14 rc 8% 7% % 3% % % rw 7 3 7 3 3 3 3 RCR 1 2 3 4 6 7 8 9 2 3 9 8 7 6 4 119 119 119 119 116 116 116 116 111 111 111 6 6 6 2 2 2 9 4 96 6 2 98 94 97 94 91 93 91 88 9 88 86 84 99 9 83 77 96 88 82 77 8 79 7 81 77 73 78 7 71 69 9 79 71 64 87 77 7 64 74 68 62 72 66 61 69 64 6 8 82 7 61 4 8 69 6 4 66 9 3 64 7 2 61 6 2 49 7 62 3 47 73 61 3 46 9 2 46 7 4 49 4 43 7 6 47 41 68 47 4 3 46 4 2 4 4 44 39 37 64 1 42 36 63 42 36 48 41 3 47 4 3 46 39 3 33 6 46 38 32 8 46 37 32 44 37 32 43 36 31 42 36 31 29 6 43 34 29 42 34 29 41 34 28 4 33 28 39 33 28 26 3 39 31 26 1 39 31 26 38 31 26 37 3 26 36 3 26 24 Zonal Lumen Summary Zone Lumens % Fixture -3 663 26.9-4 8 43.9-6 1913 77.8-9 249. -18 249. Luminance Data Angle in Deg 4 6 7 8 -Deg 4-Deg 9-Deg 196 2143 236 1811 2116 2332 1643 28 2381 1331 279 248 772 618 371 Zonal Lumen Summary Zone Lumens % Fixture -3 771 26.9-4 127 43.9-6 2227 77.8-9 2863. -18 2863. Luminance Data Angle in Deg 4 6 7 8 -Deg 4-Deg 9-Deg 474 4978 38 4241 4926 433 3833 4916 6 314 483 47 1729 142 86
INTERATED SENSOR 14CZ2 LED The Cruze ST with Integrated Sensor technology provides automatic energy savings without sacrificing performance. Traditionally, these types of energy savings required coordination between the luminaire and a lighting control system. The Cruze ST delivers superior lighting with integrated occupancy and daylighting controls. Capture the benefits of traditional lighting controls, without complicated coverage planning or special wiring. Ideal for new construction or retrofit, the Cruze ST delivers automatic ON to an energy saving light level, while ensuring lighting is turned OFF when the space is unoccupied. The integral daylight sensor reduces the need for special daylight zone planning. Each luminaire will automatically adjust the light level based on reflected light beneath the sensor in a closed loop method. The integral sensor can be offered in both standalone (SVPD1) and networked (SWPD1, LWIPD1, and SLVPD1) for application versatility. We make connections work Coverage Top View C L 3.3m [ ft.] Side View m [ ft.] m [ ft.] m [ ft.] EATON POWER Unparalleled knowledge of electrical power management LIHTIN Advanced LED fixtures CONNECTIVITY Communications & sensing technology Physical devices & controllers APPS Software applications Data accumulation & analysis Major Motion Reccomended Mounting Height 8 12 ft. Installation of integrated sensors within 3-ft (1m) of HVAC air vents is not recommended. Systems comparison chart provides many lighting system solutions designed to satisfy code requirements and meet the unique needs of any project. Distributed Low-Voltage Power System WaveLinx LumaWatt Pro Space type Interior Interior/Outdoor Any Stand-alone or Network Stand-alone Both Network Need-based feature progression Basic compliance only Occupancy sensing Daylight harvesting Zone control Scheduling -V dimming Individual fixture control Retrofit+Building Integration Total wireless connectivity A/V integration BMS integration UI options (touchscreen, apps, etc.) Enterprise level building integration Facility management & tools Floor plan & reporting tools Value-added services Asset tracking API integration Analytics/higher problem solving
14 Cruze ST LED with VividTune Tunable White VividTune tunable white luminaires from deliver high-quality light in a broad range of continuously variable color temperatures and intensities. Create a dynamic environment by adjusting the ambient light warmer or cooler to influence mood, support the task at hand, or create a dramatic ambience. The ability to control correlated color temperature and intensity separately using simple controls is the next evolution of LED lighting for the commercial, educational, healthcare and hospitality space. The unparalleled flexibility and number of lighting environments enable users to find the right light with tunable white. Performance Data* Tunable White - Lumen Adjustment Factors 3K-K 27K-6K 8 CRI 9 CRI 8 CRI 9 CRI 27K - -.93.771 Setting 1' x 4' Cruze ST LED - Example of Approximate Lumen Calculation Standard Catalog # VividTune 8 CRI Catalog # VividTune 9 CRI Catalog # 14CZ2-3-UNV-L83-CD1-U 14CZ2-3-UNV-L83-W2A1-U 14CZ2-3-UNV-L93-W2A1-U 3K.929.76.928.81 3K.983.836.961.842 4K 1.33.93.981.868 4K 1.42.918.999.891 K 1.42.918 1.13.99 3K - 3294 2712 3K 34 3486 2963 4K - 366 32 4K - 369 32 K - 369 32 6K - - 1.28.933 Controlling VividTune Tunable White VividTune luminaires make tunable white more accessible by using simple and familiar controls. From wall dimmers to wireless controls, VividTune tunable white luminaires are compatible with industry standard -V dimming controls. A single -V dimming input is used to control intensity (brightness) while a second -V dimming input is used to adjust. For suggested control configurations, go to for tunable white application guides. Example of Lumen Adjustment Calculation 14CZ2-3-UNV-L83-W2A1-U at 8 CRI tuned to 3K Adjusted Lumen = published lm x adjusted lm factor warm 27K -V cool 6K Adjusted Lumen = 34 x.983 Adjusted Lumen = 3486 lm warm 3K -V cool K * Lumen adjustment factors are for reference and may be different for each product selected. Refer to IES files for actual performance data on each. % % Intensity -V