Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Similar documents
Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Series Upflow/Horizontal Gas Furnace

Rheem Classic Series Upflow/Horizontal Gas Furnace

Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev.

W801T (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu (80% A.F.U.E. )

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

UPFLOW/ HORIZONTAL GAS FURNACE

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Downflow Gas Furnace

Rheem Classic Series Downflow Gas Furnace

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )

Ruud Ultra Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

Table of Contents GF801U Series

Rheem Classic Plus Super Quiet 80 Upflow/Horizontal Gas Furnace

Rheem Value Series Downflow Gas Furnace

Rheem Classic Series Two-Stage Upflow/Horizontal Gas Furnaces

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)

GAS FURNACES QUIET 80 80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

80% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES CLASSIC SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace

Rheem Value Series Upflow/Horizontal Gas Furnace

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

GAS FURNACES ACHIEVER SERIES SUPER QUIET % A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES

GAS FURNACES CLASSIC SERIES SUPER QUIET 80 80% A.F.U.E. DOWNFLOW GAS FURNACES

80 PLUS A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH

GAS FURNACES II 80.0% 81.4% A.F.U.E. UPFLOW/ HORIZONTAL GAS FURNACES SILHOUETTE

80% A.F.U.E. DOWNFLOW GAS FURNACES

Sample Residence HVAC Load Calculations

Cased/Uncased Coils For Gas And Oil Furnaces

Cooling Capacity CFM in. w.c. (125 Pa)

G8MVL. Product Specifications

Cased/Uncased Coils For Gas And Oil Furnaces

TECHNICAL GUIDE MODELS: P4HU 80 AFUE MULTI-POSITION GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger.

Rheem High Efficiency Air Handler

Rheem Air Handlers. RHLP- Standard Efficiency X-13 (ECM) Motor

Product Data. that this product meets the S 95% AFUE S Two -stage operation

GMS9/GCS9 SERIES 93% AFUE

TECHNICAL GUIDE MODELS: G8T-UP 80 AFUE UPFLOW/HORIZONTAL GAS-FIRED FURNACES DESCRIPTION WARRANTY FEATURES Rev.

TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE

Cased/Uncased Coils For Gas And Oil Furnaces

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

F8MTL. Product Specifications

VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input

FG7T (E and N Series)

KG7T (E and N Series)

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

Cooling Capacity CFM in. w.c. (125 Pa)

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

KG7S (A and K Series)

FG7S (C and L Series)

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

FG7T (A and K Series)

N9MSB. PS 92 Product Specifications. 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL /2/17

95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES

Cooling Capacity CFM in. w.c. (125 Pa)

UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS)

TECHNICAL GUIDE MODELS: P4DN 80 AFUE DOWNFLOW GAS-FIRED FURNACES DESCRIPTION. WARRANTY 20-year limited warranty on the heat exchanger.

TECHNICAL GUIDE 80 AFUE DOWNFLOW GAS-FIRED FURNACES MODELS: G8T-DN DESCRIPTION WARRANTY FEATURES Rev. B (0303)

KG7T (C and L Series)

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

This parts list is current as of the above revision date. See for the current revision.

FG7T (A and K Series)

A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN

Ruud High Efficiency Air Handler

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL

Cooling Capacity CFM in. w.c. (125 Pa)

95G1-E. Aluminized steel primary heat exchanger with crimped non-welded construction AL 29-4C Stainless steel secondary heat exchanger

TECHNICAL GUIDE. Echelon MODELS: FC8S GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

GMS8/GDS8/GHS8. Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

This parts list is current as of the above revision date. See for the current revision.

95% Gas Furnaces. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 95G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

G9MXE. Product Specifications

TECHNICAL GUIDE AFFINITY MODELS: PS8 GAS-FIRED HIGH EFFICIENCY SINGLE STAGE DOWNFLOW FURNACES 80% AFUE DESCRIPTION WARRANTY FEATURES

VMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

WFSR. Product Specifications 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

G9MXE. Product Specifications

TSTAT0101SC Recommended (sold separately)

WFAR. Product Specifications 92.1 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

80% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor

96G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

80% Gas Furnace. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 80G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNERS

PRODUCT SPECIFICATIONS GMS8/GDS8/GHS8 SERIES 80% AFUE MULTI-POSITION, SINGLE-STAGE/MULTI-SPEED GAS FURNACE

This parts list is current as of the above revision date. See for the current revision.

KG7T (C and L Series)

92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER CABINET DESIGN AIR DELIVERY SYSTEM CONTROLS VENTING

95% Gas Furnaces A95-1E. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits CONFIGURATIONS

N9MPD Product Specifications

93% Gas Furnaces Single Stage

Multi-Position, Multi-Speed Gas Furnaces

DM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h

Transcription:

Gas Furnaces Rheem Classic Plus Series Upflow/Horizontal Gas Furnace R801T- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-125 kbtu A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test procedures. 80% residential Gas Furnace CSA certified 3 way multi poise design UF / HZ PlusOne Diagnostics 7 Segment LED all units PlusOne Ignition System DSI for reliability and longevity Heat exchanger is removable for improved serviceability. Aluminized steel construction provides maximum corrosion resistance and thermal fatigue reliability. Solid doors provide quiet operation Solid bottom Insulated blower compartment Low profile 34" cabinet ideal for space constrained installations Blower shelf design serviceable in all furnace orientations Hemmed edges on cabinets and doors 1/4 turn door knobs for tool less access Integrated Control board features dip switches for easy system set up QR code for quick access to product information from your smart phone or tablet Constant Torque electrically commutated motor FORM NO. G11-544 REV. 1

Table of Contents TABLE OF CONTENTS Standard & Optional Equipment...3 Model Features/Physical Data & Specifications...4 Model Number Identification...5 Dimensional Data...6-7 Blower Performance Data...8 Accessories...9 Limited Warranty...10 2

Standard & Optional Equipment PATENTED HEAT EXCHANGER DRAFT INDUCER MOTOR IN-SHOT BURNERS DIRECT SPARK IGNITOR INTEGRATED FURNACE CONTROL STANDARD EQUIPMENT Completely assembled and wired; induced draft; pressure switch; redundant main gas control; blower compartment door safety switch; solid state time on/time off blower control; limit control; manual shutoff valve, pressure regulator for natural and L.P. (propane) gas; transformer; direct drive multi-speed blower motor. Furnaces are equipped with cooling/heating relay and transformer (40VA) ready for air conditioning applications. (Please note: a thermostat is not included as standard equipment.) Flame sensor diagnostics. CONSTANT TORQUE MOTOR OPTIONAL EQUIPMENT Side and bottom filter frame assembly. Return air cabinet for all sizes. NOTE: Furnace is not listed for use with fuels other than natural or L.P. (propane) gas. The complete terms of limited and other warranties are available at our sales office, or through local installer. All models can be converted by a qualified Rheem distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a Rheem parts distributor. For L.P. (propane) operation, refer to Conversion Kit Index Form. NOTE: For natural and L.P. (propane) gas models, direct spark ignition is 100% safety lockout type. WARNING THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR USE IN MOBILE HOMES 3

Model Features/Physical Data & Specifications Model Features 80% residential Gas Furnace CSA certified 3 way multi poise design UF / HZ PlusOne Diagnostics 7 Segment LED all units PlusOne Ignition System DSI for reliability and longevity Heat exchanger is removable for improved serviceability. Aluminized steel construction provides maximum corrosion resistance and thermal fatigue reliability. Solid doors provide quiet operation Solid bottom Insulated blower compartment Low profile 34" cabinet ideal for space constrained installations Blower shelf design serviceable in all furnace orientations Hemmed edges on cabinets and doors 1/4 turn door knobs for tool less access Integrated Controls board features dip switches for easy system set up QR code for quick access to product information from your smart phone or tablet Constant Torque electrically commutated motor Physical Data and Specifications MODEL NUMBERS R801T SERIES R801TA050314M*A R801TA075417M*A R801TA075421M*A R801TA100521M*A R801TA125524M*A Input-BTU/Hr [kw] ➁ 50,000 [15] 75,000 [22] 75,000 [22] 100,000 [29] 125,000 [37] Heating Capacity BTU/Hr [kw] ➀ 40,000 [12] 60,000 [18] 60,000 [18] 80,000 [23] 100,000 [29] Heat Ext. Static Pressure [kpa].10 [.025].12 [.029].12 [.029].15 [.037].20 [.05] Blower (D x W) [mm] 11 x 6 11 x 7 11 x 7 11 x 10 11 x 10 [279 x 152] [279 x 178] [279 x 178] [279 x 254] [279 x 254] Motor H.P. Speed PSC Type [W] 1/2-5 Spd Constant Torque [373] 1/2-5 Spd Constant Torque [373] 3/4-5 Spd Constant Torque [560] 3/4-5 Spd Constant Torque [560] 3/4-5 Spd Constant Torque [560] Motor Full Load Amps 6.2 6.2 8.1 8.1 8.1 Heating Speed Med-Low Med Med Med-Low Med Cooling Speed High High High High High Cooling CFM @ Rating Point [L/s] 1300 [613] 1450 [684] Max. E.S.P. (In. W.C.) [kpa] 0.9 [.22] 0.9 [.22] 0.9 [.22] 0.9 [.22] 0.9 [.22] Temperature Rise Range F [ C] Max. Outlet Air Temp. F [ C] Approx. Shipping Weight (Lbs.) [kg] 25-55 [13.9-30.6] 155 [68.3] 110 [50] 25-55 [13.9-30.6] 155 [68.3] 125 [57] 1600 [755] 25-55 [13.9-30.6] 160 [71.1] 140 [64] 1850 [873] 35-65 [19.4-36.1] 180 [82.2] 140 [64] 1950 [920] 35-65 [19.4-36.1] 165 [73.8] 150 [68] AFUE ➀ 80.0% 80.0% 80.0% 80.0% 80.0% NOTES: All models are 115V, 60HZ, 1 Ph. Gas connection size for all models is 1 /2" [12 mm] N.P.T. ➀ In accordance with D.O.E. test procedures. ➁ See Conversion Kit Index Form for high altitude derate. * S = Standard, X = Low Nox [ ] Designates Metric Conversions 4

Model Number Identification Model Number Identification R 80 1 T A 075 4 17 M S A Rheem 80 = 80% AFUE 1 = Single Stage T = Constant Torque Design Series A = 1st Design Input BTU/HR [kw] 050 = 50,000 [15] 075 = 75,000 [22] 100 = 100,000 [29] 125 = 125,000 [37] 3 = Up to 3 Ton 4 = 2 1 /2 to 4 Ton 5 = 3 1 /2 to 5 Ton Cabinet Width 14 = 14".0 17 = 17.5" 21 = 21".0 24 = 24.5" M = Multi X = Low NOx S = Standard Revision- Marketing (A First Time Release) [ ] Designates Metric Conversions 5

Dimensional Data Upflow Application Dimensional Data: Upflow Model REDUCED CLEARANCE (IN.) [mm] SHIP MODEL A B C D E F WGTS. R801T- LEFT RIGHT BACK TOP FRONT VENT SIDE SIDE (LBS.) [kg] 050 14 1 /2 [356] 12 27 /32 [326] 10 5 /8 [270] ➀ 11 1 /2 [292] 1 7 /8 [48] 0 4 [102] ➁ 0 1 [25] 3 [76] 6 [152] ➂ 110 [50] 075417 17 1 /2 [445] 16 11 /32 [415] 12 3 /8 [314] ➀ 15 1 /2 [381] 2 1 /2 [64] 0 3 [76] ➁ 0 1 [25] 3 [76] 6 [152] ➂ 125 [57] 075421/ 100 21 1 /2 [533] 19 27 /32 [504] 14 1 /8 [359] ➀ 18 1 /2 [470] 2 1 /2 [64] 0 0 0 1 [25] 3 [76] 6 [152] ➂ 140 [64] 125 24 1 /2 [622] 23 11 /32 [593] 15 7 /8 [403] ➀ 22 1 /2 [559] 2 1 /2 [64] 0 0 0 1 [25] 3 [76] 6 [152] ➂ 150 [68] NOTES: ➀ May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter. ➁ May be 0" [0 mm] with type B vent. ➂ May be 1" [25 mm] with type B vent. Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and in accordance with local codes. [ ] Designates Metric Conversions 6

Dimensional Data Horizontal Application WARNING THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR INSTALLATION ON ITS BACK, WITH ACCESS DOORS FACING UPWARDS. Dimensional Data: Horizontal Model REDUCED CLEARANCE (IN.) [mm] SHIP MODEL A B C D E F WGTS. R801T- LEFT RIGHT BACK TOP FRONT VENT SIDE SIDE (LBS.) [kg] 050 14 1 /2 [356] 12 27 /32 [326] 10 5 /8 [270] ➀ 11 1 /2 [292] 1 7 /8 [48] 0 4 [102] ➁ 0 1 [25] 3 [76] 6 [152] ➂ 110 [50] 075417 17 1 /2 [445] 16 11 /32 [415] 12 3 /8 [314] ➀ 15 1 /2 [381] 2 1 /2 [64] 0 3 [76] ➁ 0 1 [25] 3 [76] 6 [152] ➂ 125 [57] 075421/ 100 21 1 /2 [533] 19 27 /32 [504] 14 1 /8 [359] ➀ 18 1 /2 [470] 2 1 /2 [64] 0 0 0 1 [25] 3 [76] 6 [152] ➂ 140 [64] 125 24 1 /2 [622] 23 11 /32 [593] 15 7 /8 [403] ➀ 22 1 /2 [559] 2 1 /2 [64] 0 0 0 1 [25] 3 [76] 6 [152] ➂ 150 [68] NOTES: ➀ May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter. ➁ May be 0" [0 mm] with type B vent. ➂ May be 1" [25 mm] with type B vent. Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and in accordance with local codes. [ ] Designates Metric Conversions 7

Blower Performance Data Blower Performance Data AIR FLOW PERFORMANCE - (-)801T (Upflow) SERIES MODELS MODEL (-)801TA050314MSA (-)801TA075417MSA (-)801TA075421MSA (-)801TA100521MSA (-)801TA125525MSA MOTOR H.P. [W] BLOWER SIZE IN [mm] 1/2 [373] 11 x 6 [279 x 152] 1/2 [373] 11 x 7 [279 x 178] 3/4 [559] 11 x 7 [279 x 178] 3/4 [559] 11 x 10 [279 x 254] 3/4 [559] 11 x 10 [279 x 254] Note: Bold data is factory heating tap. SPEED TAP CFM [L/s] AIR DELIVERY EXTERNAL STATIC PRESSURE INCHES WATER COLUMN [kpa] 0.1 [.02] 0.2 [.05] 0.3 [.07] 0.4 [.10] 0.5 [.12] 0.6 [.15] 0.7 [.17] 0.8 [.19] 0.9 [.22] LOW 894 775 655 595 533 496 462 423 357 MED. LOW 971 912 875 839 804 758 713 684 644 MEDIUM 1117 1081 1051 1024 995 973 938 908 878 MED. HIGH 1326 1291 1275 1240 1204 1171 1144 1114 1077 HIGH 1440 1432 1405 1382 1353 1322 1305 1272 1251 LOW 1208 1141 1103 1057 1008 966 916 869 818 MED. LOW 1363 1318 1275 1230 1189 1129 1091 1053 1012 MEDIUM 1447 1417 1366 1329 1288 1250 1215 1176 1137 MED. HIGH 1553 1521 1478 1444 1407 1372 1332 1259 1264 HIGH 1616 1574 1547 1508 1478 1438 1402 1375 1341 LOW 1176 1133 1095 1048 1000 951 908 861 810 MED. LOW 1353 1312 1267 1236 1186 1149 1106 1079 1016 MEDIUM 1400 1346 1307 1276 1225 1181 1145 1103 1069 MED. HIGH 1568 1537 1498 1468 1433 1399 1353 1320 1287 HIGH 1785 1775 1736 1704 1673 1629 1608 1573 1550 LOW 1277 1211 1164 1103 1035 967 861 800 740 MED. LOW 1556 1498 1456 1409 1353 1308 1254 1198 1125 MEDIUM 1644 1597 1554 1511 1463 1400 1358 1304 1253 MED. HIGH 1879 1842 1785 1729 1692 1674 1621 1579 1537 HIGH 2071 2025 1992 1948 1902 1872 1840 1795 1750 LOW 1398 1338 1278 1232 1177 1130 1041 975 909 MED. LOW 1593 1546 1495 1454 1414 1342 1304 1251 1190 MEDIUM 1878 1844 1807 1753 1714 1675 1634 1578 1536 MED. HIGH 2025 1967 1931 1886 1856 1812 1748 1721 1668 HIGH 2165 2124 2082 2047 2012 1973 1934 1894 1859 [ ] Designates Metric Conversions 8

Accessories BOTTOM RETURN FILTER RACK FOR UPFLOW APPLICATION: RXGF-CB SIDE RETURN FILTER RACK: RXGF-CD MODEL R801TA050 R801TA075417 R801TA075421/ R801TA100 R801TA125 4" FLUE ADAPTER: RXGW-C01 FILTER RACK FILTER SIZES* INCHES [mm] INDOOR COIL CASINGS RXGF-CB (UPFLOW/ HORIZONTAL) 12 1 /4 x 25 [311 x 635] 15 3 /4 x 25 [400 x 635] 19 1 /4 x 25 [489 x 635] 22 3 /4 x 25 [578 x 635] MODEL NUMBER RXBC-D14AI RXBC-D17AI RXBC-D21AI RXBC-D21BI RXBC-D24AI RXGF-CD (UPFLOW) SIDE RETURN 15 3 /4 x 25 [400 x 635] 15 3 /4 x 25 [400 x 635] 15 3 /4 x 25 [400 x 635] 15 3 /4 x 25 [400 x 635] WARNING: IMPORTANT NOTICE A SOLID METAL BASE PLATE (SEE TABLE) MUST BE IN PLACE WHEN THE FURNACE IS INSTALLED WITH SIDE AIR RETURN DUCTS. FAILURE TO INSTALL A BASE PLATE COULD CAUSE PRODUCTS OF COMBUSTION TO BE CIRCULATED INTO THE LIVING SPACE AND CREATE POTENTIALLY HAZARDOUS CONDITIONS. FURNACE SOLID BASE BASE WIDTH BOTTOM PLATE NO. PLATE SIZE IN. [mm] KIT NO. IN. [mm] 14 1 /2 [356] RXGB-D14 AE-61874-01 11 5 /8 x 23 9 /16 [295 x 598] 17 1 /2 [445] RXGB-D17 AE-61874-02 15 1 /8 x 23 9 /16 [384 x 598] 21 1 /2 [533] RXGB-D21 AE-61874-03 18 5 /8 x 23 9 /16 [473 x 598] 24 1 /2 [622] RXGB-D24 AE-61874-04 25 5 /8 x 23 9 /16 [651 x 598] FOR HIGH ALTITUDES: OPTION CODE FOR HIGH ALTITUDE: U.S. None required for high altitudes. HIGH ALTITUDE CONVERSION KITS: U.S. None required for high altitudes. 80+ HIGH ALTITUDE INSTRUCTIONS CAUTION: Always follow National Fuel Gas Code (NFGC) guidelines when converting for high altitudes. High altitude option codes are not required for these models. However, the burner orifice size needs to be recalculated and verified at elevations above 2000 ft. See Installation Instructions for more information. [ ] Designates Metric Conversions 9

Limited Warranty GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate. Conditional Parts* (Registration Required)...Ten (10) Years Heat Exchanger...Twenty (20) Years 10

Notes 11

The new degree of comfort. In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Heating, Cooling & Water Heating P.O. Box 17010 Fort Smith, Arkansas 72917 www.rheem.com Rheem Canada Ltd./Ltée 125 Edgeware Road, Unit 1 Brampton, Ontario L6Y 0P5 PRINTED IN U.S.A. 12/14 QG FORM NO. G11-544 REV. 1