Cable Cubby 650 UT Installation Guide

Similar documents
Cable Cubby 1202 and 1402 Installation Guide

Cable Cubby 1200 and 1400 Installation Guide

Cable Cubby 500 and 700 Installation Guide

Retractor SM Installation Guide

AVEdge 100 Installation Guide

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

Specification Grade Contemporary Wall Mount/Technical Installation Data

Captivate Illuminated Mirror Light

SF 10C SUB Subwoofer Setup Guide

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

OSQ Series IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Area Light TO INSTALL:

PVM 220 Installation Guide

Acme Conduit Entry. String Combiner/Pass-Through. FOR PHOTOVOLTAIC INSTALLATION Installation Manual

PVM 220 Installation Guide

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

Installation Instructions

ebus Button Panel Decora Series Setup Guide

M9109-GGx-5 Series Proportional Electric Non-spring Return Actuators

OmniAire Omnitec Design, Manufacturing Air Purification Equipment Since 1988

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

Wet Rated Batten LED Luminaire

Installation Instructions

Tetra minimax. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide

VA-4233-AGx Series Electric Valve Actuators

INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing

ebus Button Panel EU and MK Series Setup Guide

MOONRING 1.5 MOONRING 3

Air Purification Unit. Operation and Maintenance Manual

(SB2) (SB1) (SB3) (SB5) (SB4) Cylindrical Installation Instructions. A. CHECKLIST (4 each AA Batteries Included) (SB1) (SB4) (SB2) (SB6) (SB6) (SB3)

M Remote Mounting Kit

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed

ED900. Low energy operator. Installation instructions: T/slide channel/pull arm mounting

Installation Instructions

System 350 S350C Temperature Slave Stage Module

Instruction Sheet ERK-XXXXKD SERIES KNOCKDOWN STANDALONE RACK

M Remote Mounting Kit

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

HOMELINK DOOR OPENER KIT

M9109-GGx-4 Series Proportional Electric Non-Spring Return Actuators

M9106-GGx-4 Series Proportional Electric Non-Spring Return Actuators

CSD Series Current Devices Split Core

INSTALLATION GUIDE FOR VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

M9106-AGx-2N0x Series Electric Non-Spring Return Actuators

Fan Relay Board (FRBii) Assembly

UNPACKING THE UNIT. Alcohol cleaning pad

M9300 Series Potentiometer Kits

WASP-P PRESSURE SENSOR

UB-2 2 Universal Button

Installation Instructions

M9109 Series Electric Non-spring Return Actuators

WARNING/AVERTISSEMENT. Coupez l alimentation électrique à la boîte de fusibles ou au disjoncteur avant servicing or installing product.

Installation Instructions

RAPID SHUTDOWN COMBINER

Installation Instructions

VA9905 Actuator and VG1600 Series Six-Way Valves

ELV1abbccd-e. Color Temperature: 30 = 3000K White 35 = 3500K White 40 = 4000K White 45 = 4500K White 50 = 5000K White

Installation Instructions

IMPORTANT: SAFETY INSTRUCTIONS

INSTALLATION INSTRUCTIONS

VWM SERIES U L R. Instruction Sheet. Vertical Wall Mount Rack LISTED

LS1 SERIES IMPORTANT: READ ALL INSTRUCTIONS THOROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF LINEAR SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE.

IMPORTANT: SAFETY INSTRUCTIONS Important: Instructions de securité

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

Lumination TM LED Luminaires Suspended LED Fixture (Series EP14)

MNBE-8D2x2 INSTRUCTIONS

M9102-AGA-3S and M9104-xGA-3S Series Electric Non-Spring Return Actuators

5300 Series Installation Guidelines

GETTING STARTED WITH IN-WALL DIMMER SWITCH

Electric Vehicle Supply Equipment

Installation Instructions RF4510-EA

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight

PVM 220 Installation Guide

Assembly and Operation Manual

VHM-P (Non-Locking) and VHM-PL (Locking) Variable Height Arm with Slide-In Mounting Plate

Chassis Hardware Kit: B D. Right Top Bracket. Top Bracket Qty: 1. Qty: 1. Qty: 2 13/16" 9/16" 25/64" 1" Hex. OPlastic Spacers. Qty: 4 0.

Air Purification Unit. Operation and Maintenance Manual

Lumination TM LED Luminaires LAL Series - Continuous Run Option

INSTRUCTION BOOK FOR. Tensioned Dual Masking Electrol

SOLA SM and SOLA SM 365 Light Engine Instruction Manual

IMPORTANT: SAFETY INSTRUCTIONS Important: Instructions de securité

WARNING / AVERTISSEMENT

LED Garage Light INSTALLATION INSTRUCTIONS. *Model number noted on carton label

poollux Power plx-pw60 & plx-pw100

LAL SERIES LED LUMINAIRE

M9300 Series Switch Kits

Installation Instructions

INSTALLATION INSTRUCTION Bollard Light 12V

Direct Communication Module

2-WAY REMOTE STARTING SYSTEM WITH 1 BUTTONS FOR AUTOMATIC TRANSMISSION RED301-2WAY / ANT-2WDSS. User Guide For Key

INSTALLATION INSTRUCTIONS

DPT-2015 Differential Pressure Transmitter for VAV Box Applications

FOR SIT-STAND WORKSTATION

Carousel Unit User Manual Replacing the Check Stand Motor

ALP/4500 FRONT APPLY SWING ARM. Revision A

Certification Exhibit FCC ID: SK9OW1 IC: 864G-OW1. FCC Rule Part: IC Radio Standards Specification: RSS-247. ACS Project Number:

100A 225A 400A PATENT PENDING

Transcription:

e NT: RTA.com for thtion O P IM tron talla w.ex uide, ins ations. o ww Go t te user g specific nd ple com ctions, a u instr Cable Cubby 650 UT Installation Guide This guide provides instructions for an experienced technician to install and connect the Extron Cable Cubby 650 UT. The Cable Cubby 650 UT units are under furniture mountable and are expandable for cable access, connections, and AC power. NOTE: This product is intended for use only with Extron UL 5V ~ A M A X TO TA L listed power modules (not included). Go to www.extron.com for recommended power modules. Planning Check with local and state regulations before starting the installation Ensure that the planned installation complies with national and local building and electrical codes. Ensure that the planned installation complies with the Americans with Disabilities Act or other accessibility requirements. Check all parts and equipment before installation Ensure that all parts are present in each kit. Ensure that necessary tools and equipment are available for the installation. Kit Contents Cable Cubby 650 UT Connectivity Bracket #4-40 Module Screws 4 #4-40 Module Screws AAP Frame Plate AAP Frame Plate Cable Grommet Plate Cable Grommet Plate 6 (/8"), (/4") Hole Plugs Hole Plugs Retractor racket Retractor Pin & Clip #6- Mounting screws and Star Washers Retractor Pin & Clip 4 #6 Pan-head Mounting Screws and Star Washers

Cable Cubby 650 UT Installation Guide (Continued) Preparing the Table Cut a hole in the surface where the enclosure will be installed. The size of the hole depends on the number of enclosures used (see Cut-out dimensions on the next page). Ensure the sides of the hole are smooth after cutting and finished before installing. Read the following information before making a cut. Determine the best location for the enclosure Ensure that the location where the Cable Cubby is to be installed is convenient for as many users as possible. Ensure that there is ample space under the table for cables. Allow at least 6 inches of cable loop for each cable (see Routing and Connecting Cables on page 7). When installing Retractors in the Cable Cubby, ensure that there is enough space for the Retractor assembly under the table or furniture. NOTE: To prevent objects from impeding cable retraction, allow at least inches of clearance from the exposed cable side of the enclosure (see the diagrams below). Excess cabling may cause clearance issues. Use zip ties to secure under-table cabling to prevent accidental contact or entanglement (see Routing and Connecting Cables). Table Top 9.0" (9 mm) 5.4" (85 mm) 9." (4 mm)." ( mm).0" (76 mm) Series/.95" (58 mm).8" (540 mm) 6.47" (67 mm).4" (57 mm) 8.95" (75 mm).0" (76 mm) Series/ XL 0 Series/ 0 Series/ XL

Cut the hole in the table and pre-drill mounting holes CAUTION: Wear safety glasses when operating power equipment. Failure to comply can result in eye injury. ATTENTION : Portez des lunettes de sécurité lorsque vous utilisez l équipement électrique. Ne pas respecter cela peut conduire à une blessure à l oeil. ATTENTION: The opening in the table for the Cable Cubby should be cut only by licensed and bonded craftspeople. Exercise care to prevent scarring or damaging the furniture. ATTENTION : L ouverture dans la table pour le Cable Cubby devrait être coupée seulement par des artisans autorisés et qualifiés. Faites attention à ne pas faire de marques sur le meuble et à ne pas l endommager. Cut-out dimensions For one or two enclosures, the cut-out dimensions and mounting hole locations are shown below. For more enclosures, multiply the length accordingly. If necessary, pre-drill into the furniture at the keyhole and mounting hole locations. 7" (78 mm).5" (8 mm).5" (8 mm) 5" (7 mm) 6.5" (65 mm) 6" (5 mm) " (76 mm) 4 /4" (08 mm) SURFACE CUT-OUT AREA - + /6 (.5 mm) 6.5" (65 mm) Keyholes () Mounting Holes (8) Keyholes (4).5" (8 mm).5" (8 mm) " (05 mm).0" (5 mm) 0" (54 mm) Mounting Holes (6) 6" (5 mm) 6.5" (65 mm) " (76 mm) 4 /4" (08 mm) SURFACE CUT-OUT AREA - + /6 (.5 mm).5" (9 mm) NOTE: Diagrams shown above are not drawn to scale. Dimensions and cut-out templates are available online at www.extron.com.

Cable Cubby 650 UT Installation Guide (Continued) Preparing the Cable Cubby Step (Only for multiple enclosures) Assemble Enclosures Before attaching the enclosure, ensure the keyhole mounting holes are orientated in the same direction. Attach the enclosures together with the four pan-head mounting screws and washers that were removed in step. Using a # screw driver, unscrew the four pan-head screws that attach the enclosure sides of the Cable Cubby together. Repeat this step on the corresponding side of the other enclosure. Detach side panels of both enclosures. Step Assemble Connectivity Modules Repeat steps and to add more enclosures to the extension. Connectivity modules allow you to populate the Cable Cubby enclosure with a combination of AAPs, cable pass-through, or Retractors. Follow the steps below to assemble the connectivity modules of your choice. Option : AAP Module Secure up to three single-space AAPs in the AAP plate. Secure the AAP plate on the connectivity brackets, using four of the provided module screws. #4-40 Nut with Captive Washer Insert cables through the bottom of the connectivity bracket. Connect cables to the AAPs. Option : Cable Pass-Through Module Option : Retractor Bracket Insert cables through the bottom of the connectivity bracket and into the holes of the grommet plate. Snap the included hole plugs into any unused holes. Secure the bracket using four of the provided pan-head mounting screws with star washers. Tighten the screws using a screwdriver. Secure the grommet plate on the connectivity bracket using four of the provided module screws. Insert the bracket as shown. The bracket may be installed on the left or right side of the enclosure and at the lowest height. NOTE: The opening of the bracket should be installed towards the outside of the enclosure. 4

Step Install the Modules Determine where the connectivity modules and/or power module will be installed in the Cable Cubby. The modules may be installed on the left or right side of the enclosure and at various heights. For the Power module: WARNING: Risk of Electric Shock. To ensure proper electrical grounding, use the provided #6- mounting screws with the star washers. AVERTISSEMENT : Risque de choc électrique. Afin d assurer une mise à la terre correcte, utilisez les fixations de mise à la terre #6- et les rondelles en étoile fournies. Secure the modules using four of the provided pan-head mounting screws and star washers. 5V~ A MAX TOTAL Insert the modules into the Cable Cubby. Mounting the Cable Cubby in the Table Align the enclosure with the pre-drilled holes under the furniture. Secure the enclosure with the appropriate screws (see Cut the hole in the table and pre-drill mounting holes on page ). Insert a mounting screw (provided) into each of the two holes. Tighten each screw until it protrudes /4 inch from the bottom of the table. Hook the Cable Cubby assembly onto the screws, as shown at right. Slide the Cable Cubby assembly into slot. 5V~ A MAX TOTAL Tighten the screws to secure the Cable Cubby assembly. 5V~ A MAX TOTAL Clearance Opening Drill pilot holes through the clearance openings on the Cable Cubby. Insert and tighten mounting screws (provided). 5

Cable Cubby 650 UT Installation Guide (Continued) Installing Retractors Follow the steps below to install Retractors. Before installing the Retractors, adjust the Retractors for horizontal or angular mounting, see the information below, then follow the installation steps below. Horizontal Mounting Cable Release Assembly Angular Mounting Remove the enclosure screws as shown on the left, then follow this step: Remove two enclosure screws (one on each side) from this position. Then, mount the Retractors as shown below. See the Cable Retractor Series/ Setup Guide, available on the Extron website, for additional steps. Move the cable release assembly upward until the angular mounting hole is visible. Reinstall the enclosure screws in this hole (both sides). NOTE: Extron recommends mounting the Retractor bracket so the release buttons for the Retractor are against the wall of the enclosure, to ensure adequate clearance below the Cable Cubby. Secure the clip on the pin. Insert the pin through the Retractor mounting hole on the side of the Cable Cubby and Retractor assembly. Insert Retractors into the Retractor bracket. 4 Secure the locking screw on each Retractor. Do not overtighten. 6

Alternative Retractor Configuration for Cable Cubby 650 UT Optional Double Retractor bracket mounting: Install brackets as shown below. Two double Retractor brackets can mount up to four Retractors. NOTE: Mount the Double Retractor bracket with the release buttons for the Retractor against the wall of the enclosure, opposite from each other, as shown below. DO NOT mount the Double Retractor bracket side by side. There is not enough space to insert the mounting pins side by side. E Secure the brackets using four of the provided pan-head mounting screws with star washers. Tighten the screws using a screwdriver. Side View Top View NOTE: Mount Retractors opposite each other (see images above). Insert the brackets as shown. The bracket may be installed on the left or right side of the enclosure and at the lowest height.. Routing and Connecting Cables CAUTION: Risk of Electric Shock. This equipment must be grounded. ATTENTION : Risque de choc électrique. Cet équipement doit être fixé au sol. Connect cables to the AV system and connect the AC power cord. Using zip ties, secure cables to the holes on the bottom of the Cable Cubby. For cable pass-through applications, allow at least 6 inches (0.9 m) of cable loop for each cable. NOTE: Ensure that there is no tension on the power cable. 7

Installation Checklist Planning (page ) Check with local and state regulations before starting the installation Check all parts and equipment before installation Determine number of enclosures to install Preparing the Table (page ) Determine the best location for the enclosure Verify sufficient space under furniture Cut a hole in the table and pre-drill mounting holes (page ) Preparing the Cable Cubby (page 4) If applicable, assemble enclosures Assemble connectivity modules Install the modules (page 5) Mounting the Cable Cubby in the Table (page 5) Mount the Cable Cubby under the table Installing Retractors (page 6) Remove Retractor screws for horizontal and angular mount applications Install Retractors into the bracket Routing and Connecting Cables (page 7) Dress cables under the table Connect cables to the AV system For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the Extron Safety and Regulatory Compliance Guide on the Extron website. 8 07-08 Extron Electronics All rights reserved. www.extron.com All trademarks mentioned are the property of their respective owners. 68-06-50 Rev. B 08 8