BAE Secura Solar Made in Germany Solar Wind Hydropower Biomass Batteries for Renewable Energy Applications
BAE Secura Solar Batteries for Renewab Applications Type PVS Cells PVS Block PVV Cells Technology Maintenance Nominal capacity (100 h) Nominal voltage Positive electrode Container (UL-94 rating) Electrolyte Water-refilling-interval 1) Typical discharge time Pole bushing Cycles IEC 60896-11/-21 Charge voltage at cyclic operation (V/cell) Float voltage at non cyclic operation (V/cell) 140 4,940 Ah SAN (HB) > 1,500 70 420 Ah 1, 6 V SAN (HB) > 1,200 140 4,940 Ah Reference temperature: 20 C 1) Reference values. The real water-refilling-interval for vented batteries depends on many factors, e.g. ambient temperature and specific battery operation. ABS (HB/V-O) > 1,500
le Energy Applications PVV Block PVSM Cells PVSM Modules PVVM Cells PVVM Modules 70 1,260 Ah 180 900 Ah 180 900 Ah 140 700 Ah 140 700 Ah 1, 6 V, 24 V, 48 V 24 V, 48 V SAN/ABS (HB/V-O) > 1,500 > 1,000 > 1,000 1,000 1,000 2.30-2.40
BAE Secura Solar Quality Made in Germany BAE solar batteries are used in renewable energy applications such as photovoltaic power generation. They are used in hybrid applications as well as in stand-alone photovoltaic systems, which include a very wide range of sizes and application fields. So BAE solar batteries have been proven in industrial energy systems even under extreme conditions as well as in private households, e.g. to increase the content of self consumed solar PV energy. Solar photovoltaic industrial system BAE offers low maintenance VLA batteries with liquid electrolyte as well as maintenance free batteries in VRLA- technology. Due to the high cyclic requirements batteries with positive tubular plates are used only. Moreover BAE is able to supply tailor-made solutions. BAE solar batteries reflect outstanding quality by: long cycle life approved acc. to IEC 61427 fully insulated battery design to ensure touch protection very good recharge behaviour excellent deep discharge capability perfect reliability due to absolute tight pole bushing external intercell connector design for all solar block batteries easy access for measurements of e.g. voltage via service ring and/or pole screw Installed maintenance free VRLA- BAE PVV battery system The company BAE is certified in accordance with international quality and environmental standards. Top quality and reliability are the core elements of the success of our products. BAE solar batteries fulfill national and international battery standards as given below: BAE Secura PVS Solar BAE Secura PVSM Solar IEC 60896-11 IEC 61427:2005 BAE Batterien GmbH Wilhelminenhofstraße 69/70 12459 Berlin GERMANY Tel.: +49 (0) 30 53001-661 Fax: +49 (0) 30 53001-667 E-mail: info@bae-berlin.de www.bae-berlin.de ISO 9001:2008 Quality Management by ISO 14001:2009 Environmental Management by BAE Secura PVV Solar BAE Secura PVVM Solar IEC 60896-21 IEC 61427:2005 OHSAS 18001:2007 Health and Safety Management by 08/2013 480 4900 Technical details may be subject to alterations. www.filusch-fiore.de
BAE SECURA PVS CELL solar Technical Specification for Vented Lead-Acid Batteries (VLA) 1. Application BAE PVS cell solar batteries are low maintenance and used to store electric energy in medium and large solar photovoltaic installations. 2. Technical data (Reference temperature 20 C) Type C 1 h C 10 h C 20 h C 72 h C 100 h C 120 h C 240 h R i 1) I k 2) Length Width Height Weight Weight Ah Ah Ah Ah Ah Ah Ah m ka mm mm mm (dry)kg(filled)kg Ue (100 %)/Vpc 1.65 1.80 1.80 1.80 1.80 1.80 1.80 Ue (80 %)/Vpc 1.74 1.91 1.91 1.91 1.91 1.91 1.91 4 PVS 280 101 201 234 279 285 288 295 0.95 2.16 105 208 420 12.5 17.0 5 PVS 350 129 258 300 358 367 370 381 0.76 2.70 126 208 420 15.2 21.0 6 PVS 420 158 318 368 444 454 458 472 0.63 3.24 147 208 420 17.8 25.0 5 PVS 550 213 371 414 476 488 496 530 0.70 2.90 126 208 535 20.0 27.0 6 PVS 660 266 469 524 604 620 630 672 0.58 3.48 147 208 535 22.8 32.0 7 PVS 770 309 543 608 700 719 729 777 0.50 4.06 168 208 535 26.4 37.0 6 PVS 900 363 671 752 907 933 945 976 0.47 4.32 147 208 710 32.7 46.0 8 PVS 1200 499 932 1,046 1,260 1,300 1,320 1,368 0.35 5.76 215 193 710 44.6 64.0 10 PVS 1500 595 1,090 1,228 1,476 1,520 1,536 1,588 0.28 7.20 215 235 710 54.3 75.9 12 PVS 1800 721 1,330 1,492 1,792 1,850 1,872 1,934 0.23 8.64 215 277 710 63.4 89.7 12 PVS 2280 890 1,670 1,868 2,188 2,250 2,292 2,397 0.22 9.18 215 277 855 75.4 110 16 PVS 3040 1,150 2,140 2,380 2,786 2,870 2,904 3,048 0.17 12.24 215 400 815 117 150 20 PVS 3800 1,483 2,790 3,120 3,643 3,760 3,816 4,008 0.14 15.30 215 490 815 127 187 22 PVS 4180 1,632 3,070 3,420 4,010 4,130 4,200 4,392 0.12 16.83 215 580 815 141 205 24 PVS 4560 1,830 3,480 3,900 4,572 4,710 4,788 5,016 0.11 18.36 215 580 815 146 218 26 PVS 4940 1,928 3,620 4,040 4,737 4,880 4,956 5,184 0.10 19.97 215 580 815 156 231 BAE SECURA PVS CELL solar batteries as dry charged version are marked with "TG". E.g. 4 PVS 280 TG 1) R i and 2) I k values according to IEC 60896-11 3. Terminal position 4 PVS 280 to 6 PVS 900 8 PVS 1200 to 12 PVS 2280 16 PVS 3040 20 PVS 3800 to 26 PVS 4940 Terminals are designed as female poles with brass inlay M10 for insulated solid copper connectors with cross-section 90, 150 or 300 mm 2 or flexible insulated copper cables with cross-section 25, 35, 50, 70, 95 or 120 mm 2. E N E R G Y F R O M B A T T E R I E S
Technical Specification of BAE SECURA PVS CELL solar 4. Design positive electrode tubular - plate with a polyester gauntlet and solid grids in a corrosion-resistant PbSb1.6SnSe - alloy negative electrode grid - plate in a low antimony alloy with long life expander material separation microporous separator electrolyte sulphuric acid with a density of 1.24 kg/l at 20 C container high impact, transparent SAN (Styrol-Acrylic-Nitrile), UL-94 rating: HB lid high impact, SAN in dark grey colour, UL-94 rating: HB plugs labyrinth plugs for arresting aerosol, optional ceramic plugs or ceramic funnel plugs according to DIN 40740 pole-bushing 100% gas- and electrolyte-tight, sliding, plastic-coated Panzerpol kind of protection IP 25 regarding DIN 40050, touch protected according to VBG 4 5. Installation BAE SECURA PVS CELL solar batteries are designed for indoor applications. 6. Maintenance every 6 months every 12 months every 3 years check battery voltage as well as temperature check of mechanical and electrical connections, record battery cell voltage as well as temperature average water-refilling interval (depending on utilization and ambient temperature) 7. Operational data depth of discharge (DOD) restricted to 80 % according to final voltage per cell and discharge time as per Item 2, deep discharges of more than 80 % DOD have to be avoided charge current may vary from 5 x I 10 down to 0.01 x I 10 charge voltage restricted from 2.30 V to 2.40 V per cell DOD per day < 20 % C 10 2.30 V 2.35 V per cell DOD per day > 20 % - 30 % C 10 2.35 V 2.40 V per cell DOD per day > 30 % C 10 to prevent electrolyte stratification, a gassing recharge must be carried out according to BAE operating instructions adjustment of charge voltage no adjustment necessary if battery temperature is between 10 C and 30 C in the monthly average, otherwise U/ T = -0.003 Vpc/K recharge to 100 % within a period of one up to 4 weeks IEC 61427 cycles test is still running, currently 2100 cycles (A+B) reached operational temperature -20 C to 55 C, recommended temperature range 10 C to 30 C self-discharge approx. 3 % per month at 20 C 8. Number of cycles as function of DOD (Depth of discharge) 16500 15000 13500 12000 10500 Cycles 9000 7500 6000 4500 3000 1500 0 0 10 20 30 40 50 60 70 80 90 Depth of discharge (DOD) 9. Transport Batteries are not subject to ADR (road transport), if the conditions of special rule 598 (chapter 3.3) are observed. 10. Standards Test standard IEC 60896-11, IEC 61427 Safety standard, ventilation EN 50272-2 BAE Batterien GmbH Wilhelminenhofstraße 69/70 12459 Berlin Germany P.O. Box 9 12442 Berlin Tel. +49 30 53001-0 Fax +49 30 5354949 E-mail: info@bae-berlin.de www.bae-berlin.de 08/2008 4805220 Technical details may be subject to alterations.