Control Valves, Fittings and Accessories

Similar documents
Control Valves, Fittings and Accessories

wd-2

Commercial Softeners

Superior Water And Air OWNER S MANUAL Model 32-CL770 & 48-CL770

Specifications. Autotrol 255 Valve. Autotrol 255 Series Valve Specifications. Flow Rates (Valve Only) Regeneration Operation

Water Specialist WS1 and WS1.25 Drawings and Service Manual 1 Control Valve Series Model: WS Control Valve Series Model: WS1.

255 Valve Specifications

Water Specialist 1 Control Valve Series Model: WS1TC 1.25 Control Valve Series Model: WS1.25TC

Water Specialist 1 Control Valve Series Model: WS1CS 1.25 Control Valve Series Model: WS1.25CS

Water Specialist WS1 and WS1.25 Drawings and Service Manual 1 Control Valve Series Model: WS Control Valve Series Model: WS1.

Water Specialist 1 Control Valve Series Model: WS1CI 1.25 Control Valve Series Model: WS1.25CI

Water Specialist 1 Control Valve Series Model: WS1EI 1.25 Control Valve Series Model: WS1.25EI

COMMERCIAL / INDUSTRIAL WATER SOFTENERS

Water Specialist WS2H and WS3 Control Valve Drawings and Service Manual

WS1 & 1.25 Man u al. Introduction. The following general warnings and the specifications in Table 1 must appear in the OEM s System Manual.

Water Specialist 1 Control Valve Series Model: WS Control Valve Series Model: WS1.25

Water Specialist 1 & 1.25 Motorized Alternating Valve

Water Specialist 1.5, 2 and 2 QC Control Valve Drawings and Service Manual

Water Specialist EE Control Valve Programming and Cover Drawing Manual

Water Specialist WS1TT Drawings and Service Manual

5600 Control Valve. Bypass Piping Boss Inlet & Outlet. Distributor Tube and basket. Brine Well. Brine Line. Over-Flow (Optional) $1.

Water Specialist 1.5" CC Control Valve Programming and Drawings Manual

Motorized Alternating Valve

Performa Valve Specifications. 263 and 268 Configurations. imagination at work

Consumer s Filter Manual. ProMate 6.0 Iron Curtain Junior Filter Manual

Iron Blaster System Owner s Manual

7-LX B 7-LX B 7-LX B 7-LX B 7-LX B

Magnum Cv Valve Specifications. Magnum IT and Standard Configurations. imagination at work

TECHNICAL SHEET AUTOTROL PERFORMA CV CONTROL VALVE - LOGIX SERIES WATER PURIFICATION VALVES - AUTOTROL

Water Specialist WS2H and WS3 Control Valve Manual

Superior Water And Air

Water Specialist igen Control Valve Programming and Cover Drawing Manual

Water Specialist WS1TT Drawings and Service Manual

Installation Instructions & Owner s Manual LINDYSPRING LCR Series II Water Conditioners

Water Specialist CK and EQ Control Valve Programming and Cover Drawing Manual

Control Valves - Fleck, Autotrol, Clack, AquaMatic & Others

OWNER S MANUAL FOR ALL GREENSAND SYSTEMS

TABLE OF CONTENTS JOB SPECIFICATIONS

Water Specialist PR Control Valve Programming and Cover Drawing Manual

Water Specialist CI Control Valve Programming and Cover Drawing Manual

Water Specialist EI Control Valve Programming and Cover Drawing Manual

COMMERCIAL CONTROL VALVES. Magnum Control Valve

TTV Series. Softening Water System. Installation, Operation and Maintenance Manual. Revised 01/17/13

TotalCare Series. Water Conditioners

SIMPLEX PREMIUM WATER SOFTENER INSTALLATION AND USER GUIDE

FLECK 2850S SERVICE MANUAL. waterpurification.pentair.com

Water Specialist 1 Control Valve Series Model: WS Control Valve Series Model: WS1.25

FLECK 2900S SERVICE MANUAL. waterpurification.pentair.com

PRESSURE GAGES AND TEST TAPS

Watco Pro Series Water Conditioner

STORM. ProMate-6.0 Iron Curtain Storm Series

Pre-Treatment Control Valve (Fleck 2850s) & Timer (Fleck SXT)

FLECK 2850 CONTROL VALVE

INSTALLATION, OPERATING AND SERVICE MANUAL ELECTRONIC WATER SOFTENER TIME CLOCK MODEL FEATURING THE 2002S VALVE

Control Valves - Fleck, Autotrol, Clack, Aquamatic & Others

NUGEN Pure Water Systems Fusion XT. Installation Instructions and Owners Manual

WS1TC Series Installation and Operation Manual

Water Specialist 1 Control Valve Series Model: WS Control Valve Series Model: WS1.25

ADVANCE. Backwashing Filters and Tannin Filter. Installation Instructions & Owner s Manual

Owner s Filter Manual. ProMate 6.0 Iron Curtain Junior Filter Manual

FLECK 2750 DOWNFLOW SERVICE MANUAL. waterpurification.pentair.com

7-LXC-50B 7-LXC-75B 7-LXC-100B 7-LX-75B 7-LX-100B 7-LX-150B 7-LX-200B 7-LX-300B

OZONE ZENTEC CAPSULATE FILTER INSTALLATION AND USER GUIDE

Model WS1 Demand. Operation & Maintenance Manual. 114 Vista Parkway Avon, IN New Aqua L.L.C.

Owner s Manual HELLENBRAND, INC.

CAT231.1 PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø OPERATING CONDITIONS 25 TO 100 PSI 100 F MAX IMUM TEMPERATURE SERIES METER

AQT-56SE ELECTRONIC SERIES PROGRAMMING MANUAL CONTROL VALVES

TNT SERIES WATER CONDITIONERS

INDUSTRIAL GRADE WATER SOFTENERS LWTS INDUSTRIAL SERIES

CAT231.1 SHUT OFF KIT (SOK) TO PREVENT BYPASS PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø

Installation and Service Manual Backwash Filter Systems

SmartChoice. Gen II itwin. Water Conditioning System. Installation, Operation, and Maintenance Manual. Installation, Operation, and Maintenance Manual

FLECK 2750 DOWNFLOW SERVICE MANUAL.

Fleck 2510 & 2510 Econominder

General Operation. To set Time of Day. To set Time of Regeneration / Backwash

ProFloSE. Downflow Brining Service Manual. IMPORTANT: Fill in pertinent information on page 2 for future reference.

Model 5600SXT Downflow

AQT-56 POWERFLO SERIES SERVICE MANUAL CONTROL VALVES

Model 5600SXT Upflow. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference

Owners Manual Installation Instructions. For Models PTCF PTCF PTCF

INDUSTRIAL GRADE WATER SOFTENERS LWTSF INDUSTRIAL SERIES

INSTALLATION, OPERATING AND SERVICE MANUAL ELECTRONIC WATER FILTER TIME CLOCK MODEL FEATURING THE 2002F VALVE

Rayne Guardian Water Conditioner This manual contains information on setting the controller and normal operating maintenance required by the owner

Service Manual SXT Upflow Control Valve for Water Conditioning and Treatment Purposes

WATER SOFTENER WITH MICROPROCESSOR INSTALLATION & OPERATING INSTRUCTIONS

STORM. ProMate-6.0 Iron Curtain Storm Series

AQUAMATIC CONTROL VALVES, STAGERS AND CONTROLLERS

Impression Plus Series

Manual for Operation & Maintenance Of Metered Carbon Filter

Sanitizer Plus Series

AQT-275 SERIES SERVICE MANUAL CONTROL VALVES

Sanitizer Plus Series. Water Conditioners

3200ET TIMER. Service Manual. IMPORTANT: Fill in pertinent information on page 2 for future reference.

FLECK 5800 LXT DOWNFLOW/UPFLOW SERVICE MANUAL

Impression Plus Series

MGTE Series 1 1/2 Metered & Time Clock

Iron Gate Air Pump System Manual

Problem and Solutions Manual

UF Series. Membrane Filtration System. Model CCUF-844

Installation / Operation Manual

Transcription:

Control Valves, Fittings and Accessories NOW WITH BATTERY PACK OPTION WS1EE TWIN ALTERNATING CONTROL VALVE 28 gpm WS2H 125 gpm WS 250 gpm WS1.5EE WS1.5SD/SP 70 gpm WS2EE WS2SD/SP 115 gpm WS2EE/QC* WS2SP/QC* 125 gpm WS1.25* WS1.25CS* 4 gpm WS1.25EE* WS1.25SD/SP* 4 gpm WS1.25TC* 4 gpm WS1* WS1CS* WS1EE* WS1SD/SP* WS1TC* *valves shown with optional accessories

WS1EE TWIN ALTERNATING CONTROL VALVE WATER SPECIALIST CONTROL VALVE Service flow 28 gpm, backwash flow 15 gpm with meter and bypass installed Solid state microprocessor with easy access front panel settings Front panel display for time of day, days until next regeneration, volume remaining, current flow rate and total volume used (Totalizer), and Tank in Service Indication Four methods to initiate regeneration; meter immediate, meter delayed, time clock delayed or pressure differential Optional double backwash feature offers optimum regeneration, cleaning ability and efficiency Adjustable cycle times with 6-cycle control delivers controlled backwash, downflow brining/slow rinse, second backwash, fast rinse, refill and downflow service Coin Cell Lithium battery back-up with a 8 hour carry over Backwash and brining ability to 21 diameter tanks Downflow or upflow brining regeneration 12-volt output AC Adapter provides safe and easy installation Treated/Soft water post fill and regeneration cycles Patented one piece expanding seal spacer stack assembly U.S. Patent 6,402,944 Patented linearly reciprocating piston operation U.S. Patent 6,444,127 Reliable and proven DC drives

Water Specialist 1 EE Twin Alternating Specifications Inlet/Outlet Fittings... ¾" to 1.5 NPS Cycles... up to 6 Valve Material... Noryl (1) or equivalent Regeneration... downflow FLOW RATES Service @15 psi drop (includes bypass and meter)... 28 gpm Backwash @ 25 psi drop... 15 gpm Cv Service... 7.28 Cv Backwash... 2.96 OPERATING PRESSURES Minimum/Maximum... 20 psi 125 psi OPERATING TEMPERATURES Minimum/Maximum... 40º 110º F METER Accuracy... ± 5% Flow Rate Range... 0.25 0 gpm Gallon Range... 20 1,500,000 gallons Totalizer... 1000-9,999,000 gallons DIMENSIONS & WEIGHT Distributor Pilot... 1.050" OD Pipe (¾" NPS) Drain Line... ¾ or 1 Male NPT Brine Line... /8 or ½ OD Poly Tube Compression Mounting Base... 2 ½ - 8 NPSM Height From Top Of Tank... 7 /8 Weight... 16 lbs. ELECTRICAL SPECIFICATIONS AC Adapter U.S. International Supply Voltage... 120V AC... 20V AC Supply Frequency...... 50 Hz Output Voltage...... Output Current...... TANK APPLICATIONS Water Softener... 6 21 diameter Water Filter (2)... 6 16 diameter CYCLES OF OPERATION (Softener / Filter Downflow) Softener Filter Cycle Range of time in minutes 1. Backwash 1 st... 1-95... Backwash 1-95 2. Regenerate Draw/Slow Rinse... 1-180. Backwash 2 nd... 1-95 4. Fast Rinse... 1-95... Rinse 1-95 5. Regenerant Refill... 0.1-99.0 or off 6. Service (downflow) Options: Backwash Filter, Bypass, Weather Cover Compatible with the following typical concentration of regenerants or chemicals: Sodium chloride, potassium chloride, potassium permanganate, sodium bisulfite, chlorine and chloramines 1. Noryl is a trademark of Sabic Innovative Plastics IP B.V. Company 2. Filter tank size calculated @ 10 gpm of backwash per square foot of bed area U.S. Patents: 6,402,944 6,444,127

WS1SD WS1SP TWIN ALTERNATING BATTERY VALVE WATER SPECIALIST CONTROL VALVE SD SP SP RECHARGING OPTIONS D Cell Battery Pack AA Rechargeable Battery Pack AC Adapter Solar Panel Service flow 28 gpm, backwash flow 15 gpm with meter and bypass installed Solid state microprocessor with easy access front panel settings Front panel display for time of day, days until next regeneration, volume remaining, current flow rate and total volume used (Totalizer), and Tank in Service Indication Four methods to initiate regeneration; meter immediate, meter delayed, time clock delayed or pressure differential Adjustable cycle times with 6-cycle control delivers controlled backwash, downflow brining/slow rinse, second backwash, fast rinse, refill and downflow service Coin Cell Lithium battery back-up with a 8 hour carry over of time of day Backwash and brining ability to 21 diameter tanks Downflow brining regeneration Post treated water regenerant refill Patented one piece expanding seal spacer stack assembly U.S. Patent 6,402,944 Patented linearly reciprocating piston operation U.S. Patent 6,444,127 Reliable and proven DC drives

WS1SD and WS1SP Twin Alternating Specifications Inlet/Outlet Fittings... ¾" to 1.5 NPS Cycles... up to 6 Valve Material... Noryl (1) or equivalent Regeneration... Downflow FLOW RATES Service @15 psi drop (includes bypass and meter)... 28 gpm Backwash @ 25 psi drop... 15 gpm Cv Service... 7.28 Cv Backwash... 2.96 OPERATING PRESSURES Minimum/Maximum... 20 psi 125 psi OPERATING TEMPERATURES Minimum/Maximum... 40º 110º F METER Accuracy... ± 5% Flow Rate Range... 0.25 0 gpm Gallon Range... 20 1,500,000 gallons Totalizer... 1000-9,999,000 gallons DIMENSIONS & WEIGHT Distributor Pilot... 1.050" OD Pipe (¾" NPS) Drain Line... ¾ or 1 Male NPT Brine Line... /8 or ½ OD Poly Tube Compression Mounting Base... 2 ½ - 8 NPSM Height From Top Of Tank... 7 /8 Weight... 16 lbs. BATTERY SPECIFICATIONS - 2 OPTIONS FOR OPERATION 6 AA nickel metal hydride batteries rechargeable for SP model 6 D cell alkaline batteries (disposable when discharged) for SD model - "D" batteries not included CHARGING SPECIFICATIONS FOR SP MODEL- 2 OPTIONS FOR OPERATION Amorphous silicon solar panels capable of three tilt angles AC adapter with output 500mA TANK APPLICATIONS Water Softener... 6 21 diameter Water Filter (2)... 6 16 diameter CYCLES OF OPERATION (Softener / Filter Downflow) Softener Filter Cycle Range of time in minutes 1. Backwash 1 st... 1-95... Backwash 1-95 2. Regenerate Draw/Slow Rinse... 1-180. Backwash 2 nd... 1-95 4. Fast Rinse... 1-95... Rinse 1-95 5. Regenerant Refill (in service with treated water)... 0.1-99.0 or off 6. Service (downflow) When replacing batteries follow state or local regulations for recycling and disposal. Options: Backwash Filter, Bypass, Weather Cover Compatible with the following typical concentration of regenerants or chemicals: Sodium chloride, potassium chloride, potassium permanganate, sodium bisulfite, chlorine and chloramines 1. Noryl is a trademark of Sabic Innovative Plastics IP B.V. Company 2. Filter tank size calculated @ 10 gpm of backwash per square foot of bed area U.S. Patents: 6,402,944 6,444,127

1 WATER SPECIALIST VALVE SPECIFICATIONS SPECIFICATIONS WS1 WS1CS WS1EE WS1SD/SP WS1TC Service @ 15 psi drop Backwash @ 25 psi drop (includes meter and bypass) (includes meter and bypass) Tank Applications: Softener Filter (1) Inlet/Outlet Fitting Connections 1-1.25 NPT 4-1.5 Sweat 4-1.5 Solvent 4-1 SharkBite 1-1.25 NPT 4-1.5 Sweat 4-1.5 Solvent 4-1 SharkBite 1-1.25 NPT 4-1.5 Sweat 4-1.5 Solvent 4-1 SharkBite Valve Material Cycles Regeneration Noryl (2) Downflow/Upflow Noryl (2) Downflow/Upflow Noryl (2) Downflow Operating Pressures Operating Temperatures Meter: Flow Rate Range Volume Range (gallons) Totalizer 0.25-20 - 50,000 gallons 0.25-20 - 1,500,000 gallons Not Applicable Distributor Pilot 1.050 O.D. Pipe 4 NPS 1.050 O.D. Pipe 4 NPS 1.050 O.D. Pipe 4 NPS Drain Line Connection Brine Line Connection 4 Male NPT Standard 1 Male NPT Optional 8 or 1 2 O.D. Poly Tube Compression 4 Male NPT Standard 1 Male NPT Optional 8 or 1 2 O.D. Poly Tube Compression 4 Male NPT Standard 1 Male NPT Optional 8 or 1 2 O.D. Poly Tube Compression Mounting Base Options 2 1 2-8 NPSM 2 1 2-8 NPSM 2 1 2-8 NPSM Height From Top of Tank 7 8 7 8 7 8 Shipping Weight 4.5 lbs. 4.5 lbs. 4.5 lbs. Electrical: Supply Voltage Supply Frequency Output Voltage Output Current 120V AC 1. Filter tank size calculated @ 10 gpm of backwash per square foot of bed area 2. Noryl is a trademark of Sabic Innovative Plastics IP B.V. Company. Acquired by use of external drain line flow control 120V AC, 6AA NMHB or 6 D Alkaline 120V AC

1.25 WATER SPECIALIST VALVE SPECIFICATIONS WS1.25 WS1.25CS 4 gpm (includes meter and bypass) 2 gpm () WS1.25EE WS1.25SD/SP 4 gpm (includes meter and bypass) 2 gpm () 4 gpm 2 gpm () WS1.25TC 6-24 diameter 1-1.25 NPT 4-1.5 Sweat 4-1.5 Solvent 4-1 SharkBite Noryl (2) Downflow/Upflow 6-24 diameter 1-1.25 NPT 4-1.5 Sweat 4-1.5 Solvent 4-1 SharkBite Noryl (2) Downflow/Upflow 6-24 diameter 1-1.25 NPT 4-1.5 Sweat 4-1.5 Solvent 4-1 SharkBite Noryl (2) Downflow 0.25-4 gpm 20-50,000 gallons 1.2 O.D. Pipe 1 NPS 4 Male NPT Standard 1 Male NPT Optional 8 or 1 2 O.D. Poly Tube Compression 0.25-4 gpm 20-1,500,000 gallons 1.2 O.D. Pipe 1 NPS 4 Male NPT Standard 1 Male NPT Optional 8 or 1 2 O.D. Poly Tube Compression Not Applicable 1.2 O.D. Pipe 1 NPS 4 Male NPT Standard 1 Male NPT Optional 8 or 1 2 O.D. Poly Tube Compression 2 1 2-8 NPSM 2 1 2-8 NPSM 2 1 2-8 NPSM 7 8 7 8 7 8 4.5 lbs. 4.5 lbs. 4.5 lbs. 120V AC 120V AC, 6AA NMHB or 6 D Alkaline 120V AC Valves shown with optional bypass.

1.5 & 2 WATER SPECIALIST VALVE SPECIFICATIONS SPECIFICATIONS WS1.5EE WS1.5SD/SP WS2EE WS2SD/SP Service @ 15 psi drop Backwash @ 25 psi drop Tank Applications: Softener Filter (1) Inlet/Outlet Fitting Connections 70 gpm 52 gpm 12-0 diameter 12-0 diameter 115 gpm 80 gpm 12-48 diameter 12-6 diameter 1.5 Female NPT 2 Female NPT Valve Material Cycles Regeneration Operating Pressures Operating Temperatures Meter: Flow Rate Range Volume Range (gallons) Totalizer Distributor Pilot Drain Line Connection Brine Line Connection Lead Free Brass Downflow/Upflow 0.5-75 gpm 20-1,500,000 gallons 1.90 O.D. Pipe 1.5 NPS 1.25 Female NPT with 4 Male NPT Standard 1 Male NPT Optional 4 Female NPT 1 2 O.D. Poly Tube Compression Lead Free Brass Downflow/Upflow Mounting Base Options 4-8 UN 4-8 UN 1.5-150 gpm 20-1,500,000 gallons 1.90 O.D. Pipe 1.5 NPS 1.5 Female NPT 1 Male NPT elbow 4 x 1 Solvent elbow 1 2 O.D. Poly Tube Compression Height From Top of Tank 9.5 7.5 Shipping Weight with Meter 21 lbs. 29 lbs. Electrical: Supply Voltage Supply Frequency Output Voltage Output Current 120V AC, 6AA NMHB or 6 D Alkaline 1. Filter tank size calculated @ 10 gpm of backwash per square foot of bed area 120V AC, 6AA NMHB or 6 D Alkaline

2 & WATER SPECIALIST VALVE SPECIFICATIONS 125 gpm 85 gpm WS2EE/QC WS2SP/QC WS2H 125 gpm (includes meter) 125 gpm 250 gpm 220 gpm WS 12-48 diameter 12-6 diameter 18-6 diameter 18-48 diameter 2 Female NPT 2 Female NPT/ 2.5 Groove Lock Lead Free Brass Downflow/Upflow 1.5-150 gpm 20-1,500,000 gallons 2.75 O.D. Pipe 2 NPS Lead Free Brass Up to 9 Downflow 1.5-125 gpm 10-999,000 gallons 2.75 O.D. Pipe 2 NPS 1.5 Female NPT 2 Female NPT/ 2.5 Groove Lock 18-96 diameter (2) 18-6 diameter Female NPT Lead Free Brass Up to 9 Downflow.5-50 gpm 10-999,000 gallons.5 O.D. Pipe NPS Female NPT 1 Male NPT elbow 4 x 1 Solvent elbow 1 2 O.D. Poly Tube Compression Quick Disconnect 4-8 UN 6 Flange Side Mount with 4-8 UN QC Base is 11.2 with 6 Flange QC Base is 11. 1 Male NPT elbow 4 x 1 Solvent elbow Quick Disconnect 4-8 UN 6 Flange Side Mount 1 Male NPT elbow 4 x 1 Solvent elbow Quick Disconnect 6 Flange Side Mount with 4-8 UN QC Base is 11.5 with 6 Flange QC Base is 11.6 with 6 Flange QC Base is 12.5 29 lbs. 50 lbs. 57 lbs. (no meter) 120V AC, 6AA NMHB or 6 D Alkaline 120V AC 24V AC 750 ma 120V AC 24V AC 750 ma 2. 18-6 diameter with standard injectors, to 96 with Brine Pump Valves shown with optional accessories.

1 & 1.25 Control Valve Fittings and Accessories 1 PVC Male NPT Elbow Assembly ¾ x 1 PVC Solvent Elbow Assembly 1 Brass Sweat Assembly LF Order No. V007 Order No. V007-01 Order No. V007-02LF ¾ Brass Sweat Assembly LF 1 Plastic Male NPT Assembly 1.25 Plastic Male NPT Assembly Order No. V007-0LF Order No. V007-04 Order V008-04 No. V007-05 1 Plastic Male BSPT Assembly 1.25 & 1.5 PVC Solvent Assembly 1.25 Plastic Male BSPT Assembly Order No. V007-06 Order No. V007-07 Order No. V007-08 1.25 & 1.5 Brass Sweat Assembly LF ¾ SharkBite Assembly 1 SharkBite Assembly Order No. V007-09LF Order V008-04 No. V007-12LF Order No. V007-1LF

1 & 1.25 Control Valve Fittings and Accessories ¾ Plastic Male BSPT Assembly ¾ John Guest QC Elbow Assembly 1 PVC Male BSPT Elbow Assembly Order No. V007-14 Order No. V007-15 Order No. V007-16 1 John Guest Straight QC Bypass 1 Straight DLFC w/silencer Order No. V007-17 Order No. V006 Order No. V008-02 1 Straight DLFC without Silencer Auxiliary Microswitch Kit WS1 Series Microswitch Assembly Order No. V008-04 Order No. V009 Order No. V014 WS2 Auxiliary Switch Kit Vertical 90 Adapter Kit Twin Interconnect Kit - 12-21 Order No. V017 Order No. V191-01 Order No. V4052-01

1 & 1.25 Control Valve Fittings and Accessories 1 & 1.25 Motorized Alternating Valve 1 & 1.25 No Hard Water Bypass Valve Order No. V069FF-01 F x F Order No. V070FF F x F 1 & 1.25 Motorized Alternating Valve 1 & 1.25 No Hard Water Bypass Valve Order No. V069MM-01 M x M Order No. V070FM F x M

1.5 and 2 Control Valve Accessories 1.5 Motorized Alternating Valve 1.5 No Hard Water Bypass Valve Order No. V071 NPT Order No. V071BSPT BSPT Order No. V097 NPT Order No. V097BSPT BSPT 2.0 Motorized Alternating Valve 2.0 No Hard Water Bypass Valve Order No. V076 NPT Order No. V076BSPT BSPT Order No. V098 NPT Order No. V098BSPT BSPT

Control Valve Accessories Motorized Alternating Valve No Hard Water Bypass Valve Order No. V08 NPT Order No. V08BSPT BSPT Order No. V099 NPT Order No. V099BSPT BSPT Other Accessories Weather Covers Wrench V008-04 Order No. V175WC-W White Order No. V175WC-A Almond Order No. V19-02 www.clackcorp.com 4462 DURAFORM LANE WINDSOR, WISCONSIN 5598-9716 USA phone (608) 846-010 fax (608) 846-2586 sales /customer service fax (800) 755-010 Form No. 2721 1/29/2015