POWER MODULE MTU 16V4000 DS2560

Similar documents
DIESEL GENERATOR SET MTU 18V2000 DS1400

DIESEL GENERATOR SET MTU 16V2000 DS1000

DIESEL GENERATOR SET MTU 12V4000 DS2000

DIESEL GENERATOR SET MTU 16V2000 DS1100

DIESEL GENERATOR SET DS03200D5S

DIESEL GENERATOR SET MTU 20V4000 DS3100

DIESEL GENERATOR SET MTU 20V4000 DS3250

DIESEL GENERATOR SET DP01800D5S

DIESEL GENERATOR SET DS01650D5S

KVA KW KVA KW

DIESEL GENERATOR SET DP03000D5S

DIESEL GENERATOR SET MTU 16V4000 DS2500

DIESEL GENERATOR SET MTU 20V4000 DS2650

DIESEL GENERATOR SET MTU 16V2000 DS KVA

DIESEL GENERATOR SET MTU 20V4000 DS4000

DIESEL GENERATOR SET MTU 12V4000 DS1650

DIESEL GENERATOR SET MTU 12V4000 DS2250

DIESEL GENERATOR SET MTU 16V4000 DS2250

DIESEL GENERATOR SET MTU 12V4000 DS1750

DIESEL GENERATOR SET MTU 16V4000 DS2250

DIESEL GENERATOR SET MTU 16V4000 DS2500

DIESEL GENERATOR SET MTU 12V4000 DS1650

KVA KW KVA KW

DIESEL GENERATOR SET MTU 20V4000 DS3600

DIESEL GENERATOR SET MTU 16V4000 DS2250

DIESEL GENERATOR SET MTU 20V4000 DS3300

DIESEL GENERATOR SET MTU 16V4000 DS2500

DIESEL GENERATOR SET MTU 4R0113 DS80

DIESEL GENERATOR SET MTU 10V1600 DS500

DIESEL GENERATOR SET MTU 12V1600 DS660

DIESEL GENERATOR SET DG00660D5

20' STANDARD CONTAINER MTU 16V2000 DS: kva MTU 18V2000 DS: kva

KVA KW KVA KW

Standby Rating 220/ / / / / /

G50U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

G100U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

60 Hz FEATURES. Exclusively from your Caterpillar dealer

Industrial Diesel Generator Set KD1250-UE 60 Hz - Emission Optimized EPA Tier 2 Certified

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Prime Hz 400 kw / 500 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

G80U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

RENTAL DIESEL GENERATOR SET

CMEC POWER GENERATION. PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET WHERE THE WORLD TURNS FOR POWER FEATURES

60 Hz FEATURES. Exclusively from your Caterpillar dealer

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 415 Volts

KTA50 Land Based Drilling Power Modules

DIESEL GENERATOR SETS

50 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

Engine Performance 1500 RPM

DIESEL GENERATOR SET. 60 Hz FEATURES

Type Dimensions Weight Tank Length: 6400mm 7836kg [17275lbs] [252in] Net 930 L 9020kg [19886lbs] Heigth: 2721mm Gross [107in]

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

STANDBY 2480 ekw 3100 kva 50 Hz 1500 rpm 400 Volts

Rental Power 800 kw. Specification sheet. Description. Features. Options

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

Prime 60Hz 155 kw / 193 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime Hz 16 kw / 20 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Industrial Diesel Generator Set KD2500-F 50 Hz Fuel Consumption Optimized

Generator Set Specifications 100 ekw (125 kva)

2800 Series 2806A-E18TAG1A Diesel Engine ElectropaK

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

Industrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded

Industrial Diesel Generator Set KD1650-E 50 Hz - Emission Optimized EPA Tier 2 Compliant

PRIME 365 ekw 456 kva 60 Hz 1800 rpm 480 Volts

DIESEL GENSET. Prime 60Hz 55 kw / 68 kva

Model: TD200 UCI274J / / /

Generator set data sheet Prime. Fuel consumption. Engine Standby rating Prime rating Continuous rating. Fuel flow

Industrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 415 Volts

PRELIMINARY. Engine Speed Standby Power Prime Power Continuous Power. RPM kwm BHP kwm BHP kwm BHP. Litre / hour

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

ENGINE DATA. 205L/s [434cfm] 565 C [1049 F] 750mm CE [30in. WG

DIESEL GENSET. Prime 60Hz 91 kw / 114 kva

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 415 Volts

Type Dimensions Weight Tank Length: 6400mm 8709kg [19200lbs] [252in] Net 930 L 10000kg [22046lbs] Heigth: 2721mm Gross [107in]

Réf GB / e ALTERNATORS. LSA Pole. Electrical and mechanical data

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva. Prime Ratings kw/kva 240MONO / 10 9 / 9

Prime 60Hz 273 kw / 341 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Generator Set Specifications 60 ekw (75 kva)

PRIME 920 ekw 1150 kva 50 Hz 1500 rpm 400 Volts

TM20UCM MODEL. Standard Features. Generator Ratings. Conditions of sale. Prime Hz 18 kw / 18 kva. General features :

2500 Prime 2100 Continuous Emissions level: EPA NSPS Stationary Emergency Tier 2

STANDBY 80 ekw 100 kva PRIME 72 ekw 90 kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

DIESEL GENERATOR SET DE220E0. Output Ratings. Technical Data. Image shown may not reflect actual package. Standby* Generator Set Model - 3 Phase

STANDBY 200 ekw 250 kva

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Image shown may not reflect actual package.

Transcription:

POWER MODULE MTU 16V4000 DS2560 50 Hz: 1,912-2,560 kva/400v 60 Hz: 1,807-2,321 kwe/480v Optional equipment shown. Standard equipment may vary. Certifications and Standards // Emissions - Fuel optimized // Generator set is designed and manufactured in facilities certified to standards ISO 9001:2008 and ISO 14001:2004 // Container - Designed and manufactured as special purpose container for the use as Generator set container, including CSC certification // Performance Assurance Certification (PAC) - Generator set tested to ISO 8528-5 for transient response - Verified product design, quality and performance integrity - All container systems are prototype and factory tested G3 // Power Rating operation is approved up to 85% for standby rated unit operation is approved up to 75% for prime rated unit operation is approved up to 100% (110%) for continuous rated unit

2 / / / MTU 16V4000 DS2560 Power Module STANDARD FEATURES // MTU Onsite Energy is a single source supplier // Global product support // Consult factory for specific warranty terms // 16V 4000 diesel engine - 76.3 liter displacement - Common rail fuel injection - 4-cycle // Engine-generator resilient mounted // Complete range of accessories // Generator - Brushless, rotating field generator - 2/3 pitch windings - Leroy somer AREP, excitation with R449 AVR - 300% short circuit capability // Digital control panel - Complete metering and protection system - LCD display - TCP/IP connection for customers // Cooling System - Separate room for cooling system/vertical split cores - Electrically driven fans/switched in 2 steps for higher efficiency Standard and Optional Features // System Ratings (kwe/kva) Voltage (L-L) 50 Hz 60 Hz 400V 400V 400V 480V 480V 480V Application Continuous Prime Standby Continuous Prime Standby Phase 3 3 3 3 3 3 Power Factor (cos phi) 0,8 0,8 0,8 0,8 0,8 0,8 kva 1,914 2,295 2,560 2,259 2,636 2,901 kwe 1,531 1,836 2,048 1,807 2,109 2,321 AMPS 2,763 3,313 3,695 2,717 3,171 3,490 Generator Manufacturer Leroy Somer Leroy Somer Leroy Somer Leroy Somer Leroy Somer Leroy Somer Generator Model LSA 52.3 L12/ LSA 52.3 L12/ LSA 52.3 L12/ LSA 52.3 L12/ LSA 52.3 L12/ LSA 52.3 L12/ 4p 4p 4p 4p 4p 4p skva@30% Voltage dip 4,530 4,530 4,530 5,750 5,750 5,750 Temp Rise 105 C/40 C 125 C/40 C 150 C/40 C 105 C/40 C 125 C/40 C 150 C/40 C Connection 4 BAR WYE 4 BAR WYE 4 BAR WYE 4 BAR WYE 4 BAR WYE 4 BAR WYE // Engine Air cleaners Oil pump Oil drain extension & S/O valve Lube oil sight glass (Oil reservoir 60 liter with automatic refilling) Return fuel cooler Fuel cleaner with water separator switchable Lube oil multi-stage filter Closed crankcase ventilation Air-filter (Heavy duty air-filter) Jacket water pump Thermostats Radiator - remote mounted Electric starting motor - 24V Governor electronic isochronous Base - formed steel SAE flywheel & bell housing Battery rack & cables Fuel optimized (both 50 Hz and 60 Hz)

3 / / / MTU 16V4000 DS2560 Power Module STANDARD and Optional FEATURES // Digital control panel(s) Digital metering Engine/generator protection functions CANBus ECU communications Multilingual capability Programmable contact outputs TCP/IP connection for customers // Generator * Leroy Somer LSA 52,3 L12/4R NEMA MG1-32, IEC 60034.1-60034.2 and standards compliance for temperature rise and motor starting Sustained short circuit current of up to 300% of the rated current for up to 10 seconds Self-ventilated IP 22 Superior voltage waveform Analog AVR R449 (Digital AVR D510) No load to full load regulation Brushless alternator with brushless pilot exciter 4 pole, rotating field 2 bearing, regreasable Close coupling Full amortisseur windings 125% rotor balancing ±0.25% voltage accuracy regulation 100% of rated load - one step 5% maximum THD total harmonic distortion // Container 40 high cube ISO container with CSC certification Rear container double doors Three lockable personnel access doors 1,500 liters diesel fuel tank Externally roof mounted critical grade exhaust silencer (stored during transport between the split core radiator) Generator circuit breaker wall mounted with access from outside Generator circuit breaker rated 3A 3,200A 3B/D 4,000A 100kA 24 VDC LED lights with battery backup * Note: Air filter will cause 5% derate in power output (kwe) and may also affect fuel consumption.

4 / / / MTU 16V4000 DS2560 Power Module Application data // Engine Manufacturer MTU Model 16V4000 G63/83 Type 4-cycle Arrangement 16-V Displacement/cylinder: l (cu inch) 76.3 (4656) Bore: mm (inch) 170 (6.69) Stroke: mm (inch) 210 (8.27) Compression ratio 16.5:1 Rated RPM: 50 Hz 1500 Rated RPM: 60 Hz 1800 Engine governor Electronic isochronous (ADEC) Standby rated power: 50 Hz: kwm (hp) 2,185 (2,930) 60 Hz: kwm (hp) 2,500 (3,352) Prime rated power: 50 Hz: kwm (hp) 1,965 (2,635) 60 Hz: kwm (hp) 2,280 (3,057) Continuous rated power: 50 Hz: kwm (hp) 1,635 (2,192) 60 Hz: kwm (hp) 1,950 (2,614) Speed regulation ±0.25% Air filter dry // Liquid Capacity (Lubrication) Total oil system: l (gal) 300 (79.3) Total oil change: l (gal) 240 (63.4) Engine jacket water capacity: l (gal) 175 (46.2) After cooler water capacity: l (gal) 50 (13.2) System coolant capacity: l (gal) 852 (225) // Electrical Electric volts DC 24 Cold cranking amps under -17.8 C (0 F) 2600 // Fuel System Maximum fuel lift: m (ft) 3 (10) Recommended fuel Diesel #2 Total fuel flow: l/hr (gal/hr) 1200 (317) // Generator Manufacturer Leroy Somer Model LSA 52,3 L12/4R Insulation class H Voltage regulation (steady state) ±0.25% Radio interference class n // Fuel Consumption ➀ 50 Hz STANDBY PRIME CONTINUOUS At 100% of power rating: l/hr (gal/hr) 500 (132) 435 (115) 367 (97) At 75% of power rating: l/hr (gal/hr) 371 (98) 329 (87) 284 (75) At 50% of power rating: l/hr (gal/hr) 254 (67) 231 (61) 201 (53) 60 Hz STANDBY PRIME CONTINUOUS At 100% of power rating: l/hr (gal/hr) 613 (162) 538 (142) 458 (121) At 75% of power rating: l/hr (gal/hr) 435 (115) 397 (105) 352 (93) At 50% of power rating: l/hr (gal/hr) 303 (80) 276 (73) 254 (67) // Cooling/Radiator System Ambient capacity of radiator: C ( F) 50 (122) Max. restriction of cooling air, intake, and discharge side of rad.: kpa (in. H 20) 0.125 (0.5) Water pump capacity: l/min (gpm) 1,350 (357) Heat rejection to coolant: kwe 3B/D 50 Hz (3B/D 60 Hz) 904 (1085) Heat rejection to coolant: kwe 3A 50 Hz (3A 50 Hz) 802 (927) Heat rejection to after cooler: kwe 3B/D 50 Hz (3B/D 60 Hz) 455 (733) Heat rejection to after cooler: kwe 3A 60 Hz (3A 50 Hz) 288 (566) Fan power: kwe 3B/D 50 Hz (3B/D 50 Hz) 41.3 (68.8) Fan power: kwe 3A 50 Hz (3A 60 Hz) 30.8 (51.4) // Air Requirements ➁ Engine room: *m 3 /min (SCFM) 708 (25,006) Air flow required for rad. Cooled unit: *m 3 /min (SCFM) 4,200 (148,344) // Exhaust System ➂ Gas temp. (stack): C ( F) 505 (941) Gas volume at stack temp: m 3 /min (CFM) 504 (17,799) Maximum allowable back pressure: kpa (in. H 20) 8.5 (34.1) ➀ Fuel density = 0.84 Kg/L ➁ Air density = 1.184 kg/m 3 (0.0739 lbm/ft 3 ) ➂ For 60 Hz standby rated power

5 / / / MTU 16V4000 DS2560 Power Module Weights and dimensions 12192 537 2167 2896 4817 Drawing above for illustration purposes only. Do not use for installation design. System Dimensions (L x W x H) Weight (dry/less tank) Power Module 12203 x 2438 x 2896 mm (480 x 96 x 114 inch) 32246 kg (71090 lbs) Weights and dimensions are based on containerized units and are estimates only. Consult the factory for accurate weights and dimensions for your specific generator set. Sound data Unit Type Full load - Standby Full load - Prime Full load - Continuous Power Module db(a) C/F C/F C/F Sound data is provided at 7 m (23 ft). Generator set tested in accordance with ISO 8528-10 and with infinite exhaust. Rating Definitions and conditions // Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. No overload capability for this rating. Ratings are in accordance with ISO 8528-1, ISO-3046-1, BS 5514, and AS 2789. Average load factor: 85%. Standby 50 Hz operating hours per year: Max. 500. // Prime power and continuous ratings apply to installations where utility power is unavailable or unreliable. At varying load for prime power ratings or non-varying load for continuous ratings, the number of generator set operating hours is unlimited. A 10% overload capacity is available for one hour in twelve for both ratings. Ratings are in accordance with ISO 8528-1, ISO 3046-1, BS 5514, and AS 2789. Average load factor: 75% (Prime) 100% (Continuous). // Continuous power ratings apply to installations where the generator set serves as utility. At constant load, the number of generator set operating hours is unlimited. A 10% overload capacity is available for one hour in twelve. Ratings are in accordance with ISO 8528-1, ISO 3046-1, BS 5514 and AS 2789. Average load factor: 100%. Operating hours/year: unlimited. // Deration factor: Altitude: Consult your local MTU Onsite Energy Power Generation Distributor for altitude derations. Temperature: Consult your local MTU Onsite Energy Power Generation Distributor for temperature derations. Product intended for use outside of the United States. C/F = Consult Factory/MTU Onsite Energy Distributor N/A = Not Available Subject to change. 32310361 Edition 01/16 ENC 2016-04. MTU Onsite Energy Part of the Rolls-Royce Group www.mtuonsiteenergy.com